Shopping Cart

No products in the cart.

VA Plumbing Code 2018 1stptg

$54.71

Virginia Plumbing Code

Published By Publication Date Number of Pages
VA 2018
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This is a fully integrated code based on the 2018 International Plumbing Code®.

PDF Catalog

PDF Pages PDF Title
1 2018 VIRGINIA PLUMBING CODE
2 2018 VIRGINIA PLUMBING CODE TITLE PAGE
3 COPYRIGHT
4 PREFACE
6 TABLE OF CONTENTS
10 CHAPTER 1 ADMINISTRATION
SECTION 101 GENERAL
11 SECTION 102 PURPOSE AND SCOPE
12 SECTION 103 APPLICATION OF CODE
14 SECTION 104 ENFORCEMENT, GENERALLY
SECTION 105 LOCAL BUILDING DEPARTMENT
15 SECTION 106 POWERS AND DUTIES OF THE BUILDING OFFICIAL
16 SECTION 107 FEES
SECTION 108 APPLICATION FOR PERMIT
18 SECTION 109 CONSTRUCTION DOCUMENTS
19 SECTION 110 PERMITS
20 SECTION 111 REGISTERED DESIGN PROFESSIONAL SERVICES
21 SECTION 112 WORKMANSHIP, MATERIALS AND EQUIPMENT
23 SECTION 113 INSPECTIONS
25 SECTION 114 STOP WORK ORDERS
SECTION 115 VIOLATIONS
SECTION 116 CERTIFICATES OF OCCUPANCY
26 SECTION 117 TEMPORARY AND MOVED BUILDINGS AND STRUCTURES; DEMOLITION
27 SECTION 118 UNSAFE BUILDINGS OR STRUCTURES
28 SECTION 119 APPEALS
30 CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 GENERAL DEFINITIONS
38 CHAPTER 3 GENERAL REGULATIONS
SECTION 301 GENERAL
SECTION 302 EXCLUSION OF MATERIALS DETRIMENTAL TO THE SEWER SYSTEM
SECTION 303 MATERIALS
SECTION 304 RODENTPROOFING
39 SECTION 305 PROTECTION OF PIPES AND PLUMBING SYSTEM COMPONENTS
SECTION 306 TRENCHING, EXCAVATION AND BACKFILL
40 SECTION 307 STRUCTURAL SAFETY
SECTION 308 PIPING SUPPORT
SECTION 309 FLOOD HAZARD RESISTANCE
41 TABLE 308.5 HANGER SPACING
SECTION 310 WASHROOM AND TOILET ROOM REQUIREMENTS
SECTION 311 TOILET FACILITIES FOR WORKERS
SECTION 312 TESTS AND INSPECTIONS
43 SECTION 313 EQUIPMENT EFFICIENCIES
SECTION 314 CONDENSATE DISPOSAL
[M] TABLE 314.2.2 CONDENSATE DRAIN SIZING
44 SECTION 315 PENETRATIONS
SECTION 316 ALTERNATIVE ENGINEERED DESIGN
46 CHAPTER 4 FIXTURES, FAUCETS AND FIXTURE FITTINGS
SECTION 401 GENERAL
SECTION 402 FIXTURE MATERIALS
SECTION 403 MINIMUM PLUMBING FACILITIES
TABLE 403.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa
47 TABLE 403.1 —continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa
48 TABLE 403.1 —continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa
49 TABLE 403.1.4 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES FOR MARINAS
50 SECTION 404 ACCESSIBLE PLUMBING FACILITIES
51 SECTION 405 INSTALLATION OF FIXTURES
52 SECTION 406 AUTOMATIC CLOTHES WASHERS
SECTION 407 BATHTUBS
53 SECTION 408 BIDETS
SECTION 409 DISHWASHING MACHINES
SECTION 410 DRINKING FOUNTAINS
SECTION 411 EMERGENCY SHOWERS AND EYEWASH STATIONS
SECTION 412 FAUCETS AND FIXTURE FITTINGS
54 SECTION 413 FLOOR AND TRENCH DRAINS
SECTION 414 FLOOR SINKS
SECTION 415 FLUSHING DEVICES FOR WATER CLOSETS AND URINALS
55 SECTION 416 FOOD WASTE DISPOSER UNITS
SECTION 417 GARBAGE CAN WASHERS
SECTION 418 LAUNDRY TRAYS
SECTION 419 LAVATORIES
SECTION 420 MANUAL FOOD AND BEVERAGE DISPENSING EQUIPMENT
SECTION 421 SHOWERS
57 SECTION 422 SINKS
SECTION 423 SPECIALTY PLUMBING FIXTURES
SECTION 424 URINALS
SECTION 425 WATER CLOSETS
SECTION 426 WHIRLPOOL BATHTUBS
58 CHAPTER 5 WATER HEATERS
SECTION 501 GENERAL
SECTION 502 INSTALLATION
59 SECTION 503 CONNECTIONS
SECTION 504 SAFETY DEVICES
60 SECTION 505 INSULATION
62 CHAPTER 6 WATER SUPPLY AND DISTRIBUTION
SECTION 601 GENERAL
SECTION 602 WATER REQUIRED
SECTION 603 WATER SERVICE
63 SECTION 604 DESIGN OF BUILDING WATER DISTRIBUTION SYSTEM
TABLE 604.3 WATER DISTRIBUTION SYSTEM DESIGN CRITERIA REQUIRED CAPACITY AT FIXTURE SUPPLY PIPE OUTLETS
TABLE 604.4 MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING FIXTURES AND FIXTURE FITTINGS
64 TABLE 604.5 MINIMUM SIZES OF FIXTURE WATER SUPPLY PIPES
TABLE 604.10.1 MANIFOLD SIZING
65 SECTION 605 MATERIALS, JOINTS AND CONNECTIONS
TABLE 605.3 WATER SERVICE PIPE
66 TABLE 605.4 WATER DISTRIBUTION PIPE
TABLE 605.8 MANUFACTURED PIPE NIPPLES
67 TABLE 605.5 PIPE FITTINGS
TABLE 605.7 VALVES
70 SECTION 606 INSTALLATION OF THE BUILDING WATER DISTRIBUTION SYSTEM
71 TABLE 606.5.4 SIZES FOR OVER FLOW PIPES FOR WATER SUPPLY TANKS
TABLE 606.5.7 SIZE OF DRAIN PIPES FOR WATER TANKS
SECTION 607 HOT WATER SUPPLY SYSTEM
72 SECTION 608 PROTECTION OF POTABLE WATER SUPPLY
73 FIGURE 608.9.1 PICTOGRAPH—DO NOT DRINK
TABLE 608.9.2.2 SIZE OF PIPE IDENTIFICATION
74 TABLE 608.1 APPLICATION OF BACKFLOW PREVENTERS
76 TABLE 608.16.1 MINIMUM REQUIRED AIR GAPS
77 TABLE 608.18.1 DISTANCE FROM CONTAMINATION TO PRIVATE WATER SUPPLIES AND PUMP SUCTION LINES
78 SECTION 609 HEALTH CARE PLUMBING
SECTION 610 DISINFECTION OF POTABLE WATER SYSTEM
79 SECTION 611 DRINKING WATER TREATMENT UNITS
SECTION 612 SOLAR SYSTEMS
SECTION 613 TEMPERATURE CONTROL DEVICES AND VALVES
80 CHAPTER 7 SANITARY DRAINAGE
SECTION 701 GENERAL
SECTION 702 MATERIALS
TABLE 702.1 ABOVE-GROUND DRAINAGE AND VENT PIPE
81 TABLE 702.2 UNDERGROUND BUILDING DRAINAGE AND VENT PIPE
TABLE 702.3 BUILDING SEWER PIPE
82 TABLE 702.4 PIPE FITTINGS
SECTION 703 BUILDING SEWER
SECTION 704 DRAINAGE PIPING INSTALLATION
TABLE 704.1 SLOPE OF HORIZONTAL DRAINAGE PIPE
83 SECTION 705 JOINTS
85 TABLE 705.18 CAULKING FERRULE SPECIFICATIONS
TABLE 705.19 SOLDERING BUSHING SPECIFICATIONS
SECTION 706 CONNECTIONS BETWEEN DRAINAGE PIPING AND FITTINGS
86 TABLE 706.3 FITTINGS FOR CHANGE IN DIRECTION
SECTION 707 PROHIBITED JOINTS AND CONNECTIONS
SECTION 708 CLEANOUTS
87 SECTION 709 FIXTURE UNITS
TABLE 709.2 DRAINAGE FIXTURE UNITS FOR FIXTURE DRAINS OR TRAPS
SECTION 710 DRAINAGE SYSTEM SIZING
88 TABLE 709.1 DRAINAGE FIXTURE UNITS FOR FIXTURES AND GROUPS
89 TABLE 710.1(1) BUILDING DRAINS AND SEWERS
TABLE 710.1(2) HORIZONTAL FIXTURE BRANCHES AND STACKSa
SECTION 711 OFFSETS IN DRAINAGE PIPING IN BUILDINGS OF FIVE STORIES OR MORE
SECTION 712 SUMPS AND EJECTORS
90 TABLE 712.4.2 MINIMUM CAPACITY OF SEWAGE PUMP OR SEWAGE EJECTOR
SECTION 713 COMPUTERIZED DRAINAGE DESIGN
91 SECTION 714 BACKWATER VALVES
SECTION 715 VACUUM DRAINAGE SYSTEMS
SECTION 716 REPLACEMENT OF UNDERGROUND BUILDING SEWERS AND BUILDING DRAINS BY PIPE-BURSTING METHODS
SECTION 717 RELINING BUILDING SEWERS AND BUILDING DRAINS
94 CHAPTER 8 INDIRECT/SPECIAL WASTE
SECTION 801 GENERAL
SECTION 802 INDIRECT WASTES
95 SECTION 803 SPECIAL WASTES
96 CHAPTER 9 VENTS
SECTION 901 GENERAL
SECTION 902 MATERIALS
SECTION 903 VENT TERMINALS
SECTION 904 OUTDOOR VENT EXTENSIONS
97 SECTION 905 VENT CONNECTIONS AND GRADES
SECTION 906 VENT PIPE SIZING
98 TABLE 906.1 SIZE AND DEVELOPED LENGTH OF STACK VENTS AND VENT STACKS
99 TABLE 906.5.1 SIZE AND LENGTH OF SUMP VENTS
SECTION 907 VENTS FOR STACK OFFSETS
SECTION 908 RELIEF VENTS—STACKS OF MORE THAN 10 BRANCH INTERVALS
SECTION 909 FIXTURE VENTS
TABLE 909.1 MAXIMUM DISTANCE OF FIXTURE TRAP FROM VENT
SECTION 910 INDIVIDUAL VENT
100 SECTION 911 COMMON VENT
TABLE 911.3 COMMON VENT SIZES
SECTION 912 WET VENTING
TABLE 912.3 WET VENT SIZE
SECTION 913 WASTE STACK VENT
101 TABLE 913.4 WASTE STACK VENT SIZE
SECTION 914 CIRCUIT VENTING
SECTION 915 COMBINATION WASTE AND VENT SYSTEM
TABLE 915.2.2 SIZE OF COMBINATION WASTE AND VENT PIPE
102 SECTION 916 ISLAND FIXTURE VENTING
SECTION 917 SINGLE-STACK VENT SYSTEM
TABLE 917.2 SINGLE STACK SIZE
103 SECTION 918 AIR ADMITTANCE VALVES
SECTION 919 ENGINEERED VENT SYSTEMS
EQUATION 9-1
104 TABLE 919.2 MINIMUM DIAMETER AND MAXIMUM LENGTH OF INDIVIDUAL BRANCH FIXTURE VENTS AND INDIVIDUAL FIXTURE HEADER VENTS FOR SMOOTH PIPES
SECTION 920 COMPUTERIZED VENT DESIGN
106 CHAPTER 10 TRAPS, INTERCEPTORS AND SEPARATORS
SECTION 1001 GENERAL
SECTION 1002 TRAP REQUIREMENTS
107 SECTION 1003 INTERCEPTORS AND SEPARATORS
108 TABLE 1003.3.5.1 CAPACITY OF GREASE INTERCEPTORSa
109 SECTION 1004 MATERIALS, JOINTS AND CONNECTIONS
110 CHAPTER 11 STORM DRAINAGE
SECTION 1101 GENERAL
SECTION 1102 MATERIALS
TABLE 1102.4 BUILDING STORM SEWER PIPE
111 TABLE 1102.5 SUBSOIL DRAIN PIPE
TABLE 1102.7 PIPE FITTINGS
SECTION 1103 TRAPS
SECTION 1104 CONDUCTORS AND CONNECTIONS
SECTION 1105 ROOF DRAINS
SECTION 1106 SIZE OF CONDUCTORS, LEADERS AND STORM DRAINS
TABLE 1106.2 STORM DRAIN PIPE SIZING
112 FIGURE 1106.1 100-YEAR, 1-HOUR RAINFALL (INCHES) EASTERN UNITED STATES
113 FIGURE 1106.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) CENTRAL UNITED STATES
114 FIGURE 1106.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) WESTERN UNITED STATES
115 FIGURE 1106.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) ALASKA
116 FIGURE 1106.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) HAWAII
117 TABLE 1106.2(1) SIZE OF CIRCULAR VERTICAL CONDUCTORS AND LEADERS
TABLE 1106.2(2) SIZE OF RECTANGULAR VERTICAL CONDUCTORS AND LEADERS
118 TABLE 1106.3 SIZE OF HORIZONTAL STORM DRAINAGE PIPING
119 TABLE 1106.6 SIZE OF SEMICIRCULAR ROOF GUTTERS
120 SECTION 1107 SIPHONIC ROOF DRAINAGE SYSTEMS
SECTION 1108 SECONDARY (EMERGENCY) ROOF DRAINS
SECTION 1109 COMBINED SANITARY AND STORM PUBLIC SEWER
SECTION 1110 CONTROLLED FLOW ROOF DRAIN SYSTEMS
SECTION 1111 SUBSOIL DRAINS
SECTION 1112 BUILDING SUBDRAINS
SECTION 1113 SUMPS AND PUMPING SYSTEMS
121 SECTION 1114 VALUES FOR CONTINUOUS FLOW
122 CHAPTER 12 SPECIAL PIPING AND STORAGE SYSTEMS
SECTION 1201 GENERAL
SECTION 1202 MEDICAL GASES
SECTION 1203 OXYGEN SYSTEMS
124 CHAPTER 13 NONPOTABLE WATER SYSTEMS
SECTION 1301 GENERAL
FIGURE 1301.4 PICTOGRAPH—DO NOT DRINK
127 SECTION 1302 GRAYWATER NONPOTABLE WATER SYSTEMS
TABLE 1302.5.1 LOCATION OF NONPOTABLE GRAYWATER REUSE STORAGE TANKS
128 SECTION 1303 RAINWATER NONPOTABLE WATER SYSTEMS
TABLE 1303.8.1 LOCATION OF RAINWATER STORAGE TANKS
129 SECTION 1304 RECLAIMED WATER SYSTEMS
132 CHAPTER 14 SUBSURFACE LANDSCAPE IRRIGATION SYSTEMS
SECTION 1401 GENERAL
SECTION 1402 SYSTEM DESIGN AND SIZING
EQUATION 14-1
133 TABLE 1402.3 LOCATION OF SUBSURFACE IRRIGATION SYSTEM
TABLE 1403.1.1 DESIGN LOADING RATE
134 SECTION 1403 INSTALLATION
TABLE 1403.2 DISTRIBUTION PIPE
136 CHAPTER 15 REFERENCED STANDARDS
ANSI
ASHRAE
ASME
138 ASPE
ASSE
140 ASTM
145 AWS
AWWA
146 CISPI
CSA
149 IAPMO
ICC
ISEA
150 MSS
NFPA
NGWA
NSF
151 PDI
PSAI
UL
152 APPENDIX A PLUMBING PERMIT FEE SCHEDULE
PERMIT ISSUANCE
UNIT FEE SCHEDULE
OTHER INSPECTIONS AND FEES
154 APPENDIX B RATES OF RAINFALL FOR VARIOUS CITIES
156 APPENDIX C STRUCTURAL SAFETY
SECTION C101 CUTTING, NOTCHING AND BORING IN WOOD MEMBERS
158 APPENDIX D DEGREE DAY AND DESIGN TEMPERATURES
TABLE D101 DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES
159 TABLE D101—continued DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES
160 TABLE D101—continued DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES
161 TABLE D101—continued DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES
162 TABLE D101—continued DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES
164 APPENDIX E SIZING OF WATER PIPING SYSTEM
SECTION E101 GENERAL
SECTION E102 INFORMATION REQUIRED
SECTION E103 SELECTION OF PIPE SIZE
168 TABLE E.1
TABLE E.2
169 FIGURE E103.3(1) EXAMPLE-SIZING
170 TABLE E103.3(1) RECOMMENDED TABULAR ARRANGEMENT FOR USE IN SOLVING PIPE SIZING PROBLEMS
171 TABLE E103.3(2) LOAD VALUES ASSIGNED TO FIXTURESa
172 TABLE E103.3(3) TABLE FOR ESTIMATING DEMAND
173 TABLE E103.3(3)-continued TABLE FOR ESTIMATING DEMAND
TABLE E103.3(4) LOSS OF PRESSURE THROUGH TAPS AND TEES IN POUNDS PER SQUARE INCH (psi)
174 TABLE E103.3(5) ALLOWANCE IN EQUIVALENT LENGTHS OF PIPE FOR FRICTION LOSS IN VALVES AND THREADED FITTINGS (feet)
TABLE E103.3(6) PRESSURE LOSS IN FITTINGS AND VALVES EXPRESSED AS EQUIVALENT LENGTH OF TUBEa (feet)
175 FIGURE E103.3(2) FRICTION LOSS IN SMOOTH PIPEa (TYPE K, ASTM B88 COPPER TUBING)
176 FIGURE E103.3(3) FRICTION LOSS IN SMOOTH PIPEa (TYPE L, ASTM B88 COPPER TUBING)
177 FIGURE E103.3(4) FRICTION LOSS IN SMOOTH PIPEa (TYPE M, ASTM B88 COPPER TUBING)
178 FIGURE E103.3(5) FRICTION LOSS IN FAIRLY SMOOTH PIPEa
179 FIGURE E103.3(6) FRICTION LOSS IN FAIRLY ROUGH PIPEa
180 FIGURE E103.3(7) FRICTION LOSS IN ROUGH PIPEa
181 SECTION E201 SELECTION OF PIPE SIZE
SECTION E202 DETERMINATION OF PIPE VOLUMES
182 TABLE E201.1 MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPING BASED ON WATER SUPPLY FIXTURE UNIT VALUES
183 TABLE E201.1—continued MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPING BASED ON WATER SUPPLY FIXTURE UNIT VALUES
184 TABLE E202. 1INTERNAL VOLUME OF VARIOUS WATER DISTRIBUTION TUBING
186 INDEX
198 HELPFUL TOOLS FOR LEARNING AND APPLYING YOUR PLUMBING CODE
199 ICC LEARNING CENTER
200 PROCTORED REMOTE ONLINE TESTING OPTION (PRONTO™)
201 ICC EVALUATION SERVICE
VA Plumbing Code 2018 1stptg
$54.71