Shopping Cart

No products in the cart.

VA VABuildingConstructionCode 2009

$65.54

Virginia Construction Code

Published By Publication Date Number of Pages
VA 2009 723
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This is a fully integrated code based on the 2009 International Building Code

PDF Catalog

PDF Pages PDF Title
1 2009 VIRGINIA CONSTRUCTION CODE
2 VIRGINIA CONSTRUCTION CODE PART 1 OF THE VIRGINIA UNIFORM STATEWIDE BUILDING CODE 2009 TITLE PAGE
3 COPYRIGHT
4 PREFACE
6 TABLE OF CONTENTS
14 CHAPTER 1 – ADMINISTRATION
SECTION 101 GENERAL
15 SECTION 102 PURPOSE AND SCOPE
16 SECTION 103 APPLICATION OF CODE
18 SECTION 104 ENFORCEMENT, GENERALLY
19 SECTION 105 LOCAL BUILDING DEPARTMENT
SECTION 106 POWERS AND DUTIES OF THE BUILDING OFFICIAL
20 SECTION 107 FEES
SECTION 108 APPLICATION FOR PERMIT
22 SECTION 109 CONSTRUCTION DOCUMENTS
23 SECTION 110 PERMITS
24 SECTION 111 RDP SERVICES
SECTION 112 WORKMANSHIP, MATERIALS AND EQUIPMENT
25 SECTION 113 INSPECTIONS
26 SECTION 114 STOP WORK ORDERS
SECTION 115 VIOLATIONS
27 SECTION 116 CERTIFICATES OF OCCUPANCY
SECTION 117 TEMPORARY AND MOVED BUILDINGS AND STRUCTURES; DEMOLITION
28 SECTION 118 BUILDINGS AND STRUCTURES BECOMING UNSAFE DURING CONSTRUCTION
29 SECTION 119 APPEALS
32 CHAPTER 2 – DEFINITIONS
SECTION 201 GENERAL
SECTION 202 DEFINITIONS
46 CHAPTER 3 – USE AND OCCUPANCY CLASSIFICATION
SECTION 301 GENERAL
SECTION 302 CLASSIFICATION
SECTION 303 ASSEMBLY GROUP A
47 SECTION 304 BUSINESS GROUP B
SECTION 305 EDUCATIONAL GROUP E
SECTION 306 FACTORY GROUP F
48 SECTION 307 HIGH-HAZARD GROUP H
49 TABLE 307.1(1) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
50 TABLE 307.1(1)—continued MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
51 TABLE 307.1(2) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIAL POSING A HEALTH HAZARD
57 SECTION 308 INSTITUTIONAL GROUP I
59 SECTION 309 MERCANTILE GROUP M
SECTION 310 RESIDENTIAL GROUP R
66 FIGURE 602.10.1.1 BRACED WALL LINES
TABLE 602.10.1.3 BRACED WALL LINE SPACING
FIGURE 602.10.1.4 ANGLED WALLS
67 FIGURE 602.10.2.2 LOCATION OF BRACED WALL PANELS
68 TABLE R602.10.3(1) BRACING REQUIREMENTS BASED ON WIND SPEED
69 TABLE R602.10.3(1)—continued BRACING REQUIREMENTS BASED ON WIND SPEED
70 TABLE R602.10.3(2) WIND ADJUSTMENT FACTORS TO THE REQUIRED LENGTH OF WALL BRACING
71 TABLE R602.10.3(3) BRACING REQUIREMENTS BASED ON SEISMIC DESIGN CATEGORY
72 TABLE R602.10.3(4) SEISMIC ADJUSTMENT FACTORS TO THE REQUIRED LENGTH OF WALL BRACING
73 TABLE R602.10.4 BRACING METHODS
74 TABLE R602.10.4 BRACING METHODS
TABLE R602.10.5.2 PARTIAL CREDIT FOR BRACED WALL PANELSLESS THAN 48 INCHES IN ACTUAL LENGTH
75 TABLE R602.10.5 MINIMUM LENGTH OF BRACED WALL PANELS
76 FIGURE R602.10.5 BRACED WALL PANELS WITH CONTINUOUS SHEATHING
77 FIGURE R602.10.6.1 METHOD ABW: ALTERNATE BRACED WALL PANEL
78 FIGURE R602.10.6.2 METHOD PFH: PORTAL FRAME WITH HOLD-DOWNS
79 FIGURE R602.10.6.3 METHOD PFG: PORTAL FRAME AT GARAGE DOOR OPENINGS IN SEISMIC DESIGN CATEGORIES A, B AND C
80 TABLE R602.10.6.4 TENSION STRAP CAPACITY REQUIRED FOR RESISTING WIND PRESSURES PERPENDICULAR TO METHOD PFH, PFG AND CS-PF BRACED WALL PANELS
81 FIGURE R602.10.6.4 METHOD CS-PF: CONTINUOUSLY SHEATHED PORTAL FRAME PANEL CONSTRUCTION
82 FIGURE R602.10.7 END CONDITIONS FOR BRACED WALL LINES WITH CONTINUOUS SHEATHING
83 FIGURE R602.10.8(1) BRACED WALL PANEL CONNECTION WHEN PERPENDICULAR TO FLOOR/CEILING FRAMING
FIGURE R602.10.8(2) BRACED WALL PANEL CONNECTION WHEN PARALLEL TO FLOOR/CEILING FRAMING
84 FIGURE R602.10.8.1(1) BRACED WALL PANEL CONNECTION TO PERPENDICULAR RAFTERS
FIGURE R602.10.8.1(2) BRACED WALL PANEL CONNECTION OPTION TO PERPENDICULAR RAFTERS OR ROOF TRUSSES
85 FIGURE R602.10.8.1(3) BRACED WALL PANEL CONNECTION OPTION TO PERPENDICULAR RAFTERS OR ROOF TRUSSES
86 FIGURE R602.10.9 MASONRY STEM WALLS SUPPORTING BRACED WALL PANELS
88 FIGURE R602.12.1 RECTANGLE CIRCUMSCRIBING AN ENCLOSED BUILDING
89 TABLE R602.12.4 MINIMUM NUMBER OF BRACING UNITS ON EACH SIDE OF THE CIRCUMSCRIBED RECTANGLE
FIGURE R602.12.5 BRACING UNIT DISTRIBUTION
92 SECTION 311 STORAGE GROUP S
93 SECTION 312 UTILITY AND MISCELLANEOUS GROUP U
94 CHAPTER 4 – SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
SECTION 401 SCOPE
SECTION 402 COVERED MALL AND OPEN MALL BUILDINGS
EQUATION 4-1
97 SECTION 403 HIGH-RISE BUILDINGS
98 TABLE 403.2.4 MINIMUM BOND STRENGTH
100 SECTION 404 ATRIUMS
101 SECTION 405 UNDERGROUND BUILDINGS
102 SECTION 406 MOTOR-VEHICLE-RELATED OCCUPANCIES
104 TABLE 406.3.5 OPEN PARKING GARAGES AREA AND HEIGHT
106 SECTION 407 GROUP I-2
107 SECTION 408 GROUP I-3
109 SECTION 409 MOTION PICTURE PROJECTION ROOMS
110 SECTION 410 STAGES, PLATFORMS AND TECHNICAL PRODUCTION AREAS
112 SECTION 411 SPECIAL AMUSEMENT BUILDINGS
113 SECTION 412 AIRCRAFT-RELATED OCCUPANCIES
TABLE 412.3.2 HEIGHT AND AREA LIMITATIONS FOR AIRPORT TRAFFIC CONTROL TOWERS
114 TABLE 412.4.6 HANGAR FIRE SUPPRESSION REQUIREMENTS
115 SECTION 413 COMBUSTIBLE STORAGE
SECTION 414 HAZARDOUS MATERIALS
116 TABLE 414.2.2 DESIGN AND NUMBER OF CONTROL AREAS
117 TABLE 414.2.5(1) MAXIMUM ALLOWABLE QUANTITY PER INDOOR AND OUTDOOR CONTROL AREA IN GROUP M AND S OCCUPANCIES NONFLAMMABLE SOLIDS AND NONFLAMMABLE AND NONCOMBUSTIBLE LIQUIDS
TABLE [F] 414.2.5(2) MAXIMUM ALLOWABLE QUANTITY OF FLAMMABLE AND COMBUSTIBLE LIQUIDSIN WHOLESALE AND RETAIL SALES OCCUPANCIES PER CONTROL AREA
119 TABLE 414.5.1 EXPLOSION CONTROL REQUIREMENTS
120 SECTION 415 GROUPS H-1, H-2, H-3, H-4 AND H-5
122 TABLE 415.3.1 MINIMUM SEPARATION DISTANCES FOR BUILDINGS CONTAINING EXPLOSIVE MATERIALS
123 TABLE 415.3.1—continued MINIMUM SEPARATION DISTANCES FOR BUILDINGS CONTAINING EXPLOSIVE MATERIALS
124 TABLE 415.3.2 DETACHED BUILDING REQUIRED
127 TABLE 415.8.2.1.1 QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5
132 SECTION 416 APPLICATION OF FLAMMABLE FINISHES
SECTION 417 DRYING ROOMS
SECTION 418 ORGANIC COATINGS
133 SECTION 419 LIVE/WORK UNITS
SECTION 420 GROUPS I-1, R-1, R-2, R-3
SECTION 421 HYDROGEN CUTOFF ROOMS
134 SECTION 422 AMBULATORY HEALTH CARE FACILITIES
SECTION 423 STORM SHELTERS
135 SECTION 424 MANUFACTURED HOMES AND INDUSTRIALIZED BUILDINGS
136 SECTION 425 ABOVEGROUND LIQUID FERTILIZER TANKS
138 CHAPTER 5 – GENERAL BUILDING HEIGHTS AND AREAS
SECTION 501 GENERAL
SECTION 502 DEFINITIONS
SECTION 503 GENERAL BUILDING HEIGHT AND AREA LIMITATIONS
SECTION 504 BUILDING HEIGHT
139 TABLE 503 ALLOWABLE BUILDING HEIGHTS AND AREAS
140 SECTION 505 MEZZANINES
141 SECTION 506 BUILDING AREA MODIFICATIONS
EQUATION 5-1
EQUATION 5-2
142 SECTION 507 UNLIMITED AREA BUILDINGS
143 SECTION 508 MIXED USE AND OCCUPANCY
144 TABLE 508.2.5 INCIDENTAL ACCESSORY OCCUPANCIES
145 TABLE 508.4 REQUIRED SEPARATION OF OCCUPANCIES (hours)
146 SECTION 509 SPECIAL PROVISIONS
148 CHAPTER 6 – TYPES OF CONSTRUCTION
SECTION 601 GENERAL
TABLE 601 FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS
SECTION 602 CONSTRUCTION CLASSIFICATION
149 TABLE 602 FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCEa
TABLE 602.4 WOOD MEMBER SIZE
150 SECTION 603 COMBUSTIBLE MATERIAL IN TYPE I AND II CONSTRUCTION
152 CHAPTER 7 – FIRE AND SMOKE PROTECTION FEATURES
SECTION 701 GENERAL
SECTION 702 DEFINITIONS
153 SECTION 703 FIRE-RESISTANCE RATINGS AND FIRE TESTS
154 SECTION 704 FIRE-RESISTANCE RATING OF STRUCTURAL MEMBERS
156 SECTION 705 EXTERIOR WALLS
EQUATION 7-1
157 EQUATION 7-2
FIGURE 705.7 EQUIVALENT OPENING FACTOR
158 TABLE 705.8 MAXIMUM AREA OF EXTERIOR WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE AND DEGREE OF OPENING PROTECTION
160 SECTION 706 FIRE WALLS
TABLE 706.4 FIRE WALL FIRE-RESISTANCE RATINGS
162 SECTION 707 FIRE BARRIERS
TABLE 707.3.9 FIRE-RESISTANCE RATING REQUIREMENTS FOR FIRE BARRIER ASSEMBLIES OR HORIZONTAL ASSEMBLIES BETWEEN FIRE AREAS
163 SECTION 708 SHAFT ENCLOSURES
166 SECTION 709 FIRE PARTITIONS
SECTION 710 SMOKE BARRIERS
167 SECTION 711 SMOKE PARTITIONS
SECTION 712 HORIZONTAL ASSEMBLIES
168 SECTION 713 PENETRATIONS
171 SECTION 714 FIRE-RESISTANT JOINT SYSTEMS
SECTION 715 OPENING PROTECTIVES
172 TABLE 715.4 FIRE DOOR AND FIRE SHUTTER FIRE PROTECTION RATINGS
175 TABLE 715.5 FIRE WINDOW ASSEMBLY FIRE PROTECTION RATINGS
TABLE 715.5.4 LIMITING SIZES OF WIRED GLASS PANELS
SECTION 716 DUCTS AND AIR TRANSFER OPENINGS
176 TABLE 716.3.2.1 FIRE DAMPER RATING
179 SECTION 717 CONCEALED SPACES
181 SECTION 718 FIRE-RESISTANCE REQUIREMENTS FOR PLASTER
SECTION 719 THERMAL- AND SOUND-INSULATING MATERIALS
182 SECTION 720 PRESCRIPTIVE FIRE RESISTANCE
183 SECTION 721 CALCULATED FIRE RESISTANCE
TABLE 721.2.1. 1 MINIMUM EQUIVALENT THICKNESS OF CAST-IN-PLACE OR PRECAST CONCRETE WALLS, LOAD-BEARING OR NONLOAD-BEARING
184 EQUATION 7-3
EQUATION 7-4
TABLE 721.2.1.2(2) FIRE-RESISTANCE RATINGS BASED ON RO.59
185 TABLE 720.1(1) MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALS
186 TABLE 720.1(1)— continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALS
187 TABLE 720.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALS
188 TABLE 720.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALS
189 TABLE 720.1(2) RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
190 TABLE 720.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
191 TABLE 720.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
192 TABLE 720.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
193 TABLE 720.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
194 TABLE 720.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
195 TABLE 720.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
196 TABLE 720.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
197 TABLE 720.1(3) MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
198 TABLE 720.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
199 TABLE 720.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
200 TABLE 720.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
201 TABLE 720.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
202 TABLE 720.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
203 TABLE 720.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
204 TABLE 720.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
205 FIGURE 721.2.1.2 FIRE-RESISTANCE RATINGS OF TWO-WYTHE CONCRETE WALLS
206 TABLE 721.2.1.2(1) VALUES OF Rn0.59 FOR USE IN EQUATION 7-4
FIGURE 721.2.1.3.1 CERAMIC FIBER JOINT PROTECTION
207 TABLE 721.2.1.4(1) MULTIPLYING FACTOR FOR FINISHES ON NONFIRE-EXPOSED SIDE OF WALL
TABLE 721.2.1.4(2) TIME ASSIGNED TO FINISH MATERIALS ON FIRE-EXPOSED SIDE OF WALL
208 TABLE 721.2.2.1 MINIMUM SLAB THICKNESS (inches)
FIGURE 721.2.2.1.2 DETERMINATION OF SLAB THICKNESS FOR SLOPING SOFFITS
EQUATION 7-5
FIGURE 721.2.2.1.3 SLABS WITH RIBBED OR UNDULATING SOFFITS
FIGURE 721.2.2.2 FIRE-RESISTANCE RATINGS FOR TWO-COURSE CONCRETE FLOORS
209 FIGURE 721.2.2.3(1) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES
FIGURE 721.2.2.3(2) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES
210 TABLE 721.2.3(1) COVER THICKNESS FOR REINFORCED CONCRETE FLOOR OR ROOF SLABS
TABLE 721.2.3(2) COVER THICKNESS FOR PRESTRESSED CONCRETE FLOOR OR ROOF SLABS
TABLE 721.2.3(3) MINIMUM COVER FOR MAIN REINFORCING BARS OF REINFORCED CONCRETE BEAMSc (APPLICABLE TO ALL TYPES OF STRUCTURAL CONCRETE)
TABLE 721.2.3(4) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS 8 INCHES OR GREATER IN WIDTH
211 TABLE 721.2.3(5) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS OF ALL WIDTHS
TABLE 721.2.4 MINIMUM DIMENSION OF CONCRETE COLUMNS (inches)
212 TABLE 721.3.2 MINIMUM EQUIVALENT THICKNESS (inches) OF BEARING OR NONBEARING CONCRETE MASONRY WALLS
213 EQUATION 7-7
TABLE 721.3.4 MINIMUM COVER OF LONGITUDINAL REINFORCEMENT IN FIRE-RESISTANCE-RATED REINFORCED CONCRETE MASONRY LINTELS (inches)
TABLE 721.3.5 MINIMUM DIMENSION OF CONCRETE MASONRY COLUMNS (inches)
EQUATION 7-8
214 TABLE 721.4.1(1) FIRE-RESISTANCE PERIODS OF CLAY MASONRY WALLS
TABLE 721.4.1(2) FIRE-RESISTANCE RATINGS FOR BEARING STEEL FRAME BRICK VENEER WALLS OR PARTITIONS
EQUATION 7-9
EQUATION 7-10
215 TABLE 721.4.1(3) VALUES OF Rn0.59
TABLE 721.4.1(4) COEFFICIENTS FOR PLASTER, pl a
TABLE 721.4.1(5) REINFORCED MASONRY LINTELS
TABLE 721.4.1(6) REINFORCED CLAY MASONRY COLUMNS
EQUATION 7-11
216 FIGURE 721.5.1(1) DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL COLUMNS
FIGURE 721.5.1(2) GYPSUM WALLBOARD PROTECTED STRUCTURAL STEEL COLUMNS WITH SHEET STEEL COLUMN COVERS
FIGURE 721.5.1(3) GYPSUM WALLBOARD PROTECTED STRUCTURAL STEEL COLUMNS WITH STEEL STUD/SCREW ATTACHMENT SYSTEM
217 FIGURE 721.5.1(4) FIRE RESISTANCE OF STRUCTURAL STEEL COLUMNS PROTECTED WITH VARIOUS THICKNESSES OF TYPE X GYPSUM WALLBOARD
FIGURE 721.5.1(5) WIDE FLANGE STRUCTURAL STEEL COLUMNS WITH SPRAYED FIRE-RESISTANT MATERIALS
FIGURE 721.5.1(6) CONCRETE PROTECTED STRUCTURAL STEEL COLUMNSa
FIGURE 721.5.1(7) CONCRETE OR CLAY MASONRY PROTECTED STRUCTURAL STEEL COLUMNS
EQUATION 7-12
218 EQUATION 7-13
EQUATION 7-14
EQUATION 7-15
219 EQUATION 7-16
EQUATION 7-17
FIGURE 721.5.2 DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL BEAMS AND GIRDERS
220 TABLE 721.6.2(1) TIME ASSIGNED TO WALLBOARD MEMBRANESa, b, c, d
221 TABLE 721.5.1(1) W/D RATIOS FOR STEEL COLUMNS
222 TABLE 721.5.1(2) PROPERTIES OF CONCRETE
TABLE 721.5.1(3) THERMAL CONDUCTIVITY OF CONCRETE OR CLAY MASONRY UNITS
223 TABLE 721.5.1(4) WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D)FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
224 TABLE 721.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D)FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
225 TABLE 721.5.1(5) FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
226 TABLE 721.5.1(5)—continued FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
227 TABLE 721.5.1(6) FIRE RESISTANCE OF CLAY MASONRY PROTECTED STEEL COLUMNS
228 TABLE 721.5.1(7) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN NORMAL-WEIGHT CONCRETEa [FIGURE 721.5.1(6)(c)]
TABLE 721.5.1(8) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN STRUCTURAL LIGHTWEIGHT CONCRETEa [FIGURE 721.5.1(6)(c)]
229 TABLE 721.5.1(9) MINIMUM COVER (inch) FOR STEEL COLUMNS IN NORMAL-WEIGHT PRECAST COVERSa [FIGURE 721.5.1(6)(a)]
TABLE 721.5.1(10) MINIMUM COVER (inch) FOR STEEL COLUMNS IN STRUCTURAL LIGHTWEIGHT PRECAST COVERSa [FIGURE 721.5.1(6)(a)]
230 EQUATION 7-18
EQUATION 7-19
EQUATION 7-20
EQUATION 7-21
TABLE 721.6.2(2) TIME ASSIGNED FOR CONTRIBUTION OF WOOD FRAME a, b, c
231 TABLE 721.6.2(3) MEMBRANEa ON EXTERIOR FACE OF WOOD STUD WALLS
TABLE 721.6.2(4) FLOORING OR ROOFING OVER WOOD FRAMINGa
TABLE 721.6.2(5) TIME ASSIGNED FOR ADDITIONAL PROTECTION
232 FIGURE 721.6.3(1) LOAD FIGURE
FIGURE 721.6.3(2) EFFECTIVE LENGTH FACTORS
234 CHAPTER 8 – INTERIOR FINISHES
SECTION 801 GENERAL
SECTION 802 DEFINITIONS
SECTION 803 WALL AND CEILING FINISHES
236 TABLE 803.9 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCYk
237 SECTION 804 INTERIOR FLOOR FINISH
SECTION 805 COMBUSTIBLE MATERIALS IN TYPES I AND II CONSTRUCTION
SECTION 806 DECORATIVE MATERIALS AND TRIM
238 SECTION 807 INSULATION
SECTION 808 ACOUSTICAL CEILING SYSTEMS
240 CHAPTER 9 – FIRE PROTECTION SYSTEMS
SECTION 901 GENERAL
SECTION 902 DEFINITIONS
243 SECTION 903 AUTOMATIC SPRINKLER SYSTEMS
244 TABLE 903.2.5.2 GROUP H-5 SPRINKLER DESIGN CRITERIA
246 TABLE 903.2.11.6 ADDITIONAL REQUIRED SUPPRESSION SYSTEMS
248 SECTION 904 ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS
249 SECTION 905 STANDPIPE SYSTEMS
252 SECTION 906 PORTABLE FIRE EXTINGUISHERS
TABLE 906.1 ADDITIONAL REQUIRED PORTABLE FIRE EXTINGUISHERS IN THE INTERNATIONAL FIRE CODE
TABLE 906.1—continued ADDITIONAL REQUIRED PORTABLE FIRE EXTINGUISHERS INTHE INTERNATIONAL FIRE CODE
253 TABLE 906.3(1) FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS
TABLE 906.3(2) FLAMMABLE OR COMBUSTIBLE LIQUIDS WITH DEPTHS LESS THAN OR EQUAL TO 0.25 INCH
254 SECTION 907 FIRE ALARM AND DETECTION SYSTEMS
262 TABLE 907.5.2.3.3 VISIBLE ALARMS
263 SECTION 908 EMERGENCY ALARM SYSTEMS
264 SECTION 909 SMOKE CONTROL SYSTEMS
265 EQUATION 9-1
EQUATION 9-2
266 EQUATION 9-3
271 SECTION 910 SMOKE AND HEAT VENTS
TABLE 910.3 REQUIREMENTS FOR DRAFT CURTAINS AND SMOKE AND HEAT VENTSa
272 EQUATION 9-4
SECTION 911 FIRE COMMAND CENTER
273 SECTION 912 FIRE DEPARTMENT CONNECTIONS
274 SECTION 913 FIRE PUMPS
SECTION 914 EMERGENCY RESPONDER SAFETY FEATURES
SECTION 915 IN-BUILDING EMERGENCY COMMUNICATIONS COVERAGE
276 CHAPTER 10 – MEANS OF EGRESS
SECTION 1001 ADMINISTRATION
SECTION 1002 DEFINITIONS
277 SECTION 1003 GENERAL MEANS OF EGRESS
278 SECTION 1004 OCCUPANT LOAD
279 TABLE 1004.1.1 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT
280 SECTION 1005 EGRESS WIDTH
SECTION 1006 MEANS OF EGRESS ILLUMINATION
281 SECTION 1007 ACCESSIBLE MEANS OF EGRESS
283 SECTION 1008 DOORS, GATES AND TURNSTILES
284 TABLE 1008.1.4.1 REVOLVING DOOR SPEEDS
289 SECTION 1009 STAIRWAYS
292 SECTION 1010 RAMPS
293 SECTION 1011 EXIT SIGNS
294 SECTION 1012 HANDRAILS
295 SECTION 1013 GUARDS
296 SECTION 1014 EXIT ACCESS
297 SECTION 1015 EXIT AND EXIT ACCESS DOORWAYS
298 TABLE 1015.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY
SECTION 1016 EXIT ACCESS TRAVEL DISTANCE
299 TABLE 1016.1 EXIT ACCESS TRAVEL DISTANCEa
SECTION 1017 AISLES
300 SECTION 1018 CORRIDORS
TABLE 1018.1 CORRIDOR FIRE-RESISTANCE RATING
301 SECTION 1019 EGRESS BALCONIES
SECTION 1020 EXITS
SECTION 1021 NUMBER OF EXITS AND CONTINUITY
302 TABLE 1021.1 MINIMUM NUMBER OF EXITS FOR OCCUPANT LOAD
TABLE 1021.2 STORIES WITH ONE EXIT
SECTION 1022 EXIT ENCLOSURES
304 SECTION 1023 EXIT PASSAGEWAYS
305 SECTION 1024 LUMINOUS EGRESS PATH MARKINGS
306 SECTION 1025 HORIZONTAL EXITS
307 SECTION 1026 EXTERIOR EXIT RAMPS AND STAIRWAYS
SECTION 1027 EXIT DISCHARGE
308 SECTION 1028 ASSEMBLY
310 TABLE 1028.6.2 WIDTH OF AISLES FOR SMOKE-PROTECTED ASSEMBLY
311 TABLE 1028.10.1 SMOKE-PROTECTED ASSEMBLY AISLE ACCESSWAYS
313 SECTION 1029 EMERGENCY ESCAPE AND RESCUE
316 CHAPTER 11 – ACCESSIBILITY
SECTION 1101 GENERAL
SECTION 1102 DEFINITIONS
SECTION 1103 SCOPING REQUIREMENTS
317 SECTION 1104 ACCESSIBLE ROUTE
318 SECTION 1105 ACCESSIBLE ENTRANCES
319 SECTION 1106 PARKING AND PASSENGER LOADING FACILITIES
TABLE 1106.1 ACCESSIBLE PARKING SPACES
320 SECTION 1107 DWELLING UNITS AND SLEEPING UNITS
321 TABLE 1107.6.1.1 ACCESSIBLE DWELLING AND SLEEPING UNITS
323 SECTION 1108 SPECIAL OCCUPANCIES
TABLE 1108.2.2.1 ACCESSIBLE WHEELCHAIR SPACES
324 TABLE 1108.2.7.1 RECEIVERS FOR ASSISTIVE LISTENING SYSTEMS
325 TABLE 1108.3 ACCESSIBLE SELF-SERVICE STORAGE FACILITIES
SECTION 1109 OTHER FEATURES AND FACILITIES
327 TABLE 1109.11.2 ACCESSIBLE CHECK-OUT AISLES
328 SECTION 1110 SIGNAGE
330 CHAPTER 12 – INTERIOR ENVIRONMENT
SECTION 1201 GENERAL
SECTION 1202 DEFINITIONS
SECTION 1203 VENTILATION
331 SECTION 1204 TEMPERATURE CONTROL
SECTION 1205 LIGHTING
332 SECTION 1206 YARDS OR COURTS
SECTION 1207 SOUND TRANSMISSION
333 TABLE 1207.4 AIRPORT NOISE ATTENUATION STANDARDS
SECTION 1208 INTERIOR SPACE DIMENSIONS
SECTION 1209 ACCESS TO UNOCCUPIED SPACES
SECTION 1210 SURROUNDING MATERIALS
334 CHAPTER 13 – ENERGY EFFICIENCY
SECTION 1301 GENERAL
336 CHAPTER 14 – EXTERIOR WALLS
SECTION 1401 GENERAL
SECTION 1402 DEFINITIONS
SECTION 1403 PERFORMANCE REQUIREMENTS
337 SECTION 1404 MATERIALS
338 TABLE 1405.2 MINIMUM THICKNESS OF WEATHER COVERINGS
SECTION 1405 INSTALLATION OF WALL COVERINGS
TABLE 1405.3.1 CLASS III VAPOR RETARDERS
342 SECTION 1406 COMBUSTIBLE MATERIALS ON THE EXTERIOR SIDE OF EXTERIOR WALLS
TABLE 1406.2.1.2 MINIMUM FIRE SEPARATION FOR COMBUSTIBLE VENEERS
343 SECTION 1407 METAL COMPOSITE MATERIALS (MCM)
344 SECTION 1408 EXTERIOR INSULATION AND FINISH SYSTEMS (EIFS)
346 CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
SECTION 1501 GENERAL
SECTION 1502 DEFINITIONS
SECTION 1503 WEATHER PROTECTION
347 SECTION 1504 PERFORMANCE REQUIREMENTS
348 TABLE 1504.8 MAXIMUM ALLOWABLE MEAN ROOF HEIGHT PERMITTED FOR BUILDINGS WITH AGGREGATE ON THE ROOF IN AREAS OUTSIDE A HURRICANE-PRONE REGION
SECTION 1505 FIRE CLASSIFICATION
TABLE 1505.1a, b MINIMUM ROOF COVERING CLASSIFICATION FOR TYPES OF CONSTRUCTION
SECTION 1506 MATERIALS
349 SECTION 1507 REQUIREMENTS FOR ROOF COVERINGS
TABLE 1507.2.7.1(1) CLASSIFICATION OF ASPHALT ROOF SHINGLES PER ASTM D 7158a
TABLE 1507.2.7.1(2) CLASSIFICATION OF ASPHALT SHINGLES PER ASTM D 3161
350 TABLE 1507.2.9.2 VALLEY LINING MATERIAL
352 TABLE 1507.3.7 CLAY AND CONCRETE TILE ATTACHMENTa,b,c
353 TABLE 1507.4.3(1) METAL ROOF COVERINGS
TABLE 1507.4.3(2) MINIMUM CORROSION RESISTANCE
354 TABLE 1507.7.6 SLATE SHINGLE HEADLAP
355 TABLE 1507.8 WOOD SHINGLE AND SHAKE INSTALLATION
356 TABLE 1507.8.5 WOOD SHINGLE MATERIAL REQUIREMENTS
TABLE 1507.8.7 WOOD SHINGLE WEATHER EXPOSURE AND ROOF SLOPE
357 TABLE 1507.9.6 WOOD SHAKE MATERIAL REQUIREMENTS
TABLE 1507.9.8 WOOD SHAKE WEATHER EXPOSURE AND ROOF SLOPE
358 TABLE 1507.10.2 BUILT-UP ROOFING MATERIAL STANDARDS
SECTION 1508 ROOF INSULATION
TABLE 1508. 2 MATERIAL STANDARDS FOR ROOF INSULATION
359 SECTION 1509 ROOFTOP STRUCTURES
360 SECTION 1510 REROOFING
362 CHAPTER 16 – STRUCTURAL DESIGN
SECTION 1601 GENERAL
SECTION 1602 DEFINITIONS AND NOTATIONS
363 SECTION 1603 CONSTRUCTION DOCUMENTS
364 SECTION 1604 GENERAL DESIGN REQUIREMENTS
TABLE 1604.3 DEFLECTION LIMITSa, b, c, h, i
366 TABLE 1604.5 OCCUPANCY CATEGORY OF BUILDINGS AND OTHER STRUCTURES
367 SECTION 1605 LOAD COMBINATIONS
EQUATION 16-1
EQUATION 16-2
EQUATION 16-3
EQUATION 16-4
EQUATION 16-5
EQUATION 16-6
EQUATION 16-7
EQUATION 16-8
EQUATION 16-9
EQUATION 16-10
EQUATION 16-11
EQUATION 16-12
EQUATION 16-13
EQUATION 16-14
EQUATION 16-15
368 EQUATION 16-16
EQUATION 16-17
EQUATION 16-18
EQUATION 16-19
EQUATION 16-20
EQUATION 16-21
SECTION 1606 DEAD LOADS
SECTION 1607 LIVE LOADS
369 TABLE 1607.1 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, Lo, AND MINIMUM CONCENTRATED LIVE LOADSg
TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, Lo, AND MINIMUM CONCENTRATED LIVE LOADSg
370 TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, Lo, AND MINIMUM CONCENTRATED LIVE LOADSg
TABLE 1607.6 UNIFORM AND CONCENTRATED LOADS
371 EQUATION 16-22
TABLE 1607.9.1 LIVE LOAD ELEMENT FACTOR, KLL
372 EQUATION 16-23
EQUATION 16-24
EQUATION 16-25
373 EQUATION 16-26
EQUATION 16-27
EQUATION 16-28
EQUATION 16-29
EQUATION 16-30
EQUATION 16-31
374 SECTION 1608 SNOW LOADS
TABLE 1608.2 GROUND SNOW LOADS, pg , FOR ALASKAN LOCATIONS
SECTION 1609 WIND LOADS
375 FIGURE 1608.2 GROUND SNOW LOADS, pg, FOR THE UNITED STATES (psf)
376 FIGURE 1608.2–continued GROUND SNOW LOADS, pg, FOR THE UNITED STATES (psf)
378 TABLE 1609.1.2 WIND-BORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELSa, b, c, d
TABLE 1609.3.1 EQUIVALENT BASIC WIND SPEEDSa, b, c
EQUATION 16-32
379 FIGURE 1609 BASIC WIND SPEED (3-SECOND GUST)
380 FIGURE 1609—continued BASIC WIND SPEED (3-SECOND GUST)
381 FIGURE 1609–continued BASIC WIND SPEED (3-SECOND GUST) WESTERN GULF OF MEXICO HURRICANE COASTLINE
382 FIGURE 1609–continued BASIC WIND SPEED (3-SECOND GUST) EASTERN GULF OF MEXICO AND SOUTHEASTERN U.S. HURRICANE COASTLINE
383 FIGURE 1609–continued BASIC WIND SPEED (3-SECOND GUST) MID AND NORTHERN ATLANTIC HURRICANE COASTLINE
384 EQUATION 16-33
385 EQUATION 16-34
TABLE 1609.6.2(1) WIND STAGNATION PRESSURE (qs) AT STANDARD HEIGHT OF 33 FEET
386 TABLE 1609.6.2(2) NET PRESSURE COEFFICIENTS, Cneta, b
387 TABLE 1609.6.2(2) —continued NET PRESSURE COEFFICIENTS, Cneta, b
388 TABLE 1609.6.2(2) —continued NET PRESSURE COEFFICIENTS, Cneta, b
389 TABLE 1609.6.2(2) —continued NET PRESSURE COEFFICIENTS, Cneta, b
390 TABLE 1609.6.2(2) —continued NET PRESSURE COEFFICIENTS, Cneta, b
SECTION 1610 SOIL LATERAL LOADS
391 TABLE 1610.1 LATERAL SOIL LOAD
SECTION 1611 RAIN LOADS
EQUATION 16-35
392 FIGURE 1611.1100- YEAR, 1-HOUR RAINFALL (INCHES) EASTERN UNITED STATES
393 FIGURE 1611.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) CENTRAL UNITED STATES
394 FIGURE 1611.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) WESTERN UNITED STATES
395 FIGURE 1611.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) ALASKA
396 FIGURE 1611.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) HAWAII
397 SECTION 1612 FLOOD LOADS
399 SECTION 1613 EARTHQUAKE LOADS
EQUATION 16-36
EQUATION 16-37
400 TABLE 1613.5.2 SITE CLASS DEFINITIONS
TABLE 1613.5.3(1) VALUES OF SITE COEFFICIENT Faa
TABLE 1613.5.3(2) VALUES OF SITE COEFFICIENT FVa
401 EQUATION 16-38
EQUATION 16-39
EQUATION 16-40
EQUATION 16-41
EQUATION 16-42
EQUATION 16-43
TABLE 1613.5.5 SITE CLASSIFICATIONa
402 TABLE 1613.5.6(1) SEISMIC DESIGN CATEGORY BASED ON SHORT-PERIOD RESPONSE ACCELERATIONS
TABLE 1613.5.6(2 ) SEISMIC DESIGN CATEGORY BASED ON 1-SECOND PERIOD RESPONSE ACCELERATION
404 EQUATION 16-44
EQUATION 16-45
SECTION 1614 STRUCTURAL INTEGRITY
405 EQUATION 16-46
EQUATION 16-47
407 FIGURE 1613.5(1) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR THE CONTERMINOUS UNITED STATES OF0.2 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
408 FIGURE 1613.5(1)—continued MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR THE CONTERMINOUS UNITED STATES OF0.2 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
409 FIGURE 1613.5(2) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR THE CONTERMINOUS UNITED STATES OF 1.0 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
410 FIGURE 1613.5(2) —continued MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR THE CONTERMINOUS UNITED STATESOF 1.0 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
411 FIGURE 1613.5(3) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR REGION 1 OF 0.2 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
412 FIGURE 1613.5(3)—continued MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR REGION 1 OF0.2 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
413 FIGURE 1613.5(4) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR REGION 1 OF1.0 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
414 FIGURE 1613.5(4)—continued MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR REGION 1 OF1.0 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
415 FIGURE 1613.5(5) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR REGION 2 OF0.2 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
416 FIGURE 1613.5(6) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR REGION 2 OF1.0 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
417 FIGURE 1613.5(7) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR REGION 3 OF 0.2 SEC SPECTRAL RESPONSE ACCELERATION (5% PERCENT OF CRITICAL DAMPING), SITE CLASS B
418 FIGURE 1613.5(8) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR REGION 3 OF 1.0 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
419 FIGURE 1613.5(9) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR REGION 4 OF 0.2 AND 1.0 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
420 FIGURE 1613.5(10) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR HAWAII OF 0.2 AND 1.0 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
421 FIGURE 1613.5(11) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR ALASKA O F0.2 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
422 FIGURE 1613.5(12) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR ALASKA OF 1.0 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
423 FIGURE 1613.5(13) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR PUERTO RICO, CULEBRA, VIEQUES, ST. THOMAS, ST. JOHN AND ST. CROIX OF 0.2 AND 1.0 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
424 FIGURE 1613.5(14) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR GUAM AND TUTUILLA OF 0.2 AND 1.0 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
425 FIGURE 1614.4 LONGITUDINAL, PERIMETER, TRANSVERSE AND VERTICAL TIES
426 CHAPTER 17 – STRUCTURAL TESTS AND SPECIAL INSPECTIONS
SECTION 1701 GENERAL
SECTION 1702 DEFINITIONS
SECTION 1703 APPROVALS
427 SECTION 1704 SPECIAL INSPECTIONS
429 TABLE 1704.3 REQUIRED VERIFICATION AND INSPECTION OF STEEL CONSTRUCTION
430 TABLE 1704.3—continued REQUIRED VERIFICATION AND INSPECTION OF STEEL CONSTRUCTION
431 TABLE 1704.4 REQUIRED VERIFICATION AND INSPECTION OF CONCRETE CONSTRUCTION
433 TABLE 1704.5.1 LEVEL 1 REQUIRED VERIFICATION AND INSPECTION OF MASONRY CONSTRUCTION
434 TABLE 1704.5.1—continued LEVEL 1 REQUIRED VERIFICATION AND INSPECTION OF MASONRY CONSTRUCTION
435 TABLE 1704.5.3 LEVEL 2 REQUIRED VERIFICATION AND INSPECTION OF MASONRY CONSTRUCTION
436 TABLE 1704.7 REQUIRED VERIFICATION AND INSPECTION OF SOILS
TABLE 1704.8 REQUIRED VERIFICATION AND INSPECTION OF DRIVEN DEEP FOUNDATION ELEMENTS
TABLE 1704.9 REQUIRED VERIFICATION AND INSPECTION OF CAST-IN-PLACE DEEP FOUNDATION ELEMENTS
438 SECTION 1705 STATEMENT OF SPECIAL INSPECTIONS
440 SECTION 1706 SPECIAL INSPECTIONS FORWIND REQUIREMENTS
SECTION 1707 SPECIAL INSPECTIONS FOR SEISMIC RESISTANCE
441 SECTION 1708 STRUCTURAL TESTING FOR SEISMIC RESISTANCE
442 SECTION 1709 CONTRACT OR RESPONSIBILITY
SECTION 1710 STRUCTURAL OBSERVATIONS
SECTION 1711 DESIGN STRENGTHS OF MATERIALS
SECTION 1712 ALTERNATIVE TEST PROCEDURE
443 SECTION 1713 TEST SAFE LOAD
SECTION 1714 IN-SITU LOAD TESTS
SECTION 1715 PRECONSTRUCTION LOAD TESTS
444 SECTION 1716 MATERIAL AND TEST STANDARDS
446 CHAPTER 18 – SOILS AND FOUNDATIONS
SECTION 1801 GENERAL
SECTION 1802 DEFINITIONS
SECTION 1803 GEOTECHNICAL INVESTIGATIONS
448 SECTION 1804 EXCAVATION, GRADING AND FILL
449 SECTION 1805 DAMPPROOFING AND WATERPROOFING
450 SECTION 1806 PRESUMPTIVE LOAD-BEARING VALUES OF SOILS
451 TABLE 1806.2 PRESUMPTIVE LOAD-BEARING VALUES
SECTION 1807 FOUNDATION WALLS, RETAINING WALLS AND EMBEDDED POSTS AND POLES
452 TABLE 1807.1.6.2 CONCRETE FOUNDATION WALLSb, c
453 TABLE 1807.1.6.3(1) PLAIN MASONRY FOUNDATION WALLSa, b, c
454 TABLE 1807.1.6.3(2) 8-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d 5 INCHESa, b, c
455 TABLE 1807.1.6.3(3) 10-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d 6.75 INCHES a, b, c
456 TABLE 1807.1.6.3(4) 12-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d 8.75 INCHESa, b, c
457 EQUATION 18-1
EQUATION 18-2
EQUATION 18-3
SECTION 1808 FOUNDATIONS
459 FIGURE 1808.7.1 FOUNDATION CLEARANCES FROM SLOPES
460 TABLE 1808.8.1 MINIMUM SPECIFIED COMPRESSIVE STRENGTH f C OF CONCRETE OR GROUT
TABLE 1808.8.2 MINIMUM CONCRETE COVER
461 SECTION 1809 SHALLOW FOUNDATIONS
TABLE 1809.7 PRESCRIPTIVE FOOTINGS SUPPORTING WALLS OF LIGHT-FRAME CONSTRUCTIONa, b, c, d, e
462 SECTION 1810 DEEP FOUNDATIONS
465 TABLE 1810.3.2.6 ALLOWABLE STRESSES FOR MATERIALS USED IN DEEP FOUNDATION ELEMENTS
466 EQUATION 18-4
468 EQUATOIN 18-5
469 EQUATION 18-6
EQUATION 18-7
EQUATION 18-8
EQUATION 18-9
EQUATION 18-10
EQUATION 18-11
476 CHAPTER 19 – CONCRETE
SECTION 1901 GENERAL
SECTION 1902 DEFINITIONS
SECTION 1903 SPECIFICATIONS FOR TESTS AND MATERIALS
SECTION 1904 DURABILITY REQUIREMENTS
477 TABLE 1904.3 MINIMUM SPECIFIED COMPRESSIVE STRENGTH
FIGURE 1904.3 WEATHERING PROBABILITY MAP FOR CONCRETE
478 SECTION 1905 CONCRETE QUALITY, MIXING AND PLACING
479 SECTION 1906 FORMWORK, EMBEDDED PIPES AND CONSTRUCTION JOINTS
SECTION 1907 DETAILS OF REINFORCEMENT
SECTION 1908 MODIFICATIONS TO ACI 318
482 SECTION 1909 STRUCTURAL PLAIN CONCRE
SECTION 1910 MINIMUM SLAB PROVISIONS
483 SECTION 1911 ANCHORAGE TO CONCRETE—ALLOWABLE STRESS DESIGN
EQUATION 19-1
TABLE 1911.2 ALLOWABLE SERVICE LOAD ON EMBEDDED BOLTS (pounds)
SECTION 1912 ANCHORAGE TO CONCRETE—STRENGTH DESIGN
484 SECTION 1913 SHOTCRETE
485 SECTION 1914 REINFORCED GYPSUM CONCRETE
SECTION 1915 CONCRETE-FILLED PIPE COLUMNS
486 CHAPTER 20 – ALUMINUM
SECTION 2001 GENERAL
SECTION 2002 MATERIALS
488 CHAPTER 21 – MASONRY
SECTION 2101 GENERAL
SECTION 2102 DEFINITIONS AND NOTATIONS
491 SECTION 2103 MASONRY CONSTRUCTION MATERIALS
492 TABLE 2103.10 CERAMIC TILE MORTAR COMPOSITIONS
SECTION 2104 CONSTRUCTION
493 SECTION 2105 QUALITY ASSURANCE
TABLE 2105.2.2.1.1 COMPRESSIVE STRENGTH OF CLAY MASONRY
494 TABLE 2105.2.2.1.2 COMPRESSIVE STRENGTH OF CONCRETE MASONRY
SECTION 2106 SEISMIC DESIGN
SECTION 2107 ALLOWABLE STRESS DESIGN
EQUATION 21-1
495 SECTION 2108 STRENGTH DESIGN OF MASONRY
SECTION 2109 EMPIRICAL DESIGN OF MASONRY
TABLE 2109.2.1 ALLOWABLE STRESS GROSS CROSS-SECTIONAL AREA FOR DRY-STACKED, SURFACE-BONDED CONCRETE MASONRY WALLS
496 EQUATION 21-2
TABLE 2109.3.3.1 ALLOWABLE SHEAR ON BOLTS IN ADOBE MASONRY
497 SECTION 2110 GLASS UNIT MASONRY
SECTION 2111 MASONRY FIREPLACES
499 FIGURE 2111.11 ILLUSTRATION OF EXCEPTION TO FIREPLACE CLEARANCE PROVISION
SECTION 2112 MASONRY HEATERS
500 SECTION 2113 MASONRY CHIMNEYS
502 TABLE 2113.16(1) NET CROSS-SECTIONAL AREA OF ROUND FLUE SIZES
503 TABLE 2113.16(2) NET CROSS-SECTIONAL AREA OF SQUARE AND RECTANGULAR FLUE SIZES
FIGURE 2113.16 FLUE SIZES FOR MASONRY CHIMNEYS
504 FIGURE 2113.19 ILLUSTRATION OF EXCEPTION THREE CHIMNEY CLEARANCE PROVISION
506 CHAPTER 22 – STEEL
SECTION 2201 GENERAL
SECTION 2202 DEFINITIONS
SECTION 2203 IDENTIFICATION AND PROTECTION OF STEEL FOR STRUCTURAL PURPOSES
SECTION 2204 CONNECTIONS
SECTION 2205 STRUCTURAL STEEL
507 SECTION 2206 STEEL JOISTS
508 SECTION 2207 STEEL CABLE STRUCTURES
SECTION 2208 STEEL STORAGE RACKS
SECTION 2209 COLD-FORMED STEEL
SECTION 2210 COLD-FORMED STEEL LIGHT-FRAME CONSTRUCTION
510 CHAPTER 23 – WOOD
SECTION 2301 GENERAL
SECTION 2302 DEFINITIONS
511 SECTION 2303 MINIMUM STANDARDS AND QUALITY
515 SECTION 2304 GENERAL CONSTRUCTION REQUIREMENTS
TABLE 2304.6 MINIMUM THICKNESS OF WALL SHEATHING
516 TABLE 2304.6.1 MAXIMUM BASIC WIND SPEED (mph) (3-SECOND GUST) PERMITTED FOR WOOD STRUCTURAL PANEL WALL SHEATHING USED TO RESIST WIND PRESSURESa, b
TABLE 2304.7(1) ALLOWABLE SPANS FOR LUMBER FLOOR AND ROOF SHEATHING
517 TABLE 2304.7(2) SHEATHING LUMBER, MINIMUM GRADE REQUIREMENTS: BOARD GRADE
TABLE 2304.7(3) ALLOWABLE SPANS AND LOADS FOR WOOD STRUCTURAL PANEL SHEATHING AND SINGLE-FLOOR GRADES CONTINUOUS OVER TWO OR MORE SPANS WITH STRENGTH AXIS PERPENDICULAR TO SUPPORTS
518 TABLE 2304.7(4) ALLOWABLE SPAN FOR WOOD STRUCTURAL PANEL COMBINATION SUBFLOOR-UNDERLAYMENT (SINGLE FLOOR)a, b (Panels Continuous Over Two or More Spans and Strength Axis Perpendicular to Supports)
TABLE 2304.7(5) ALLOWABLE LOAD (PSF) FOR WOOD STRUCTURAL PANEL ROOF SHEATHING CONTINUOUS OVER TWO OR MORE SPANS AND STRENGTH AXIS PARALLEL TO SUPPORTS (Plywood Structural Panels Are Five-Ply, Five-Layer Unless Otherwise Noted)
521 TABLE 2304.9.1 FASTENING SCHEDULE
522 TABLE 2304.9.1—continued FASTENING SCHEDULE
523 TABLE 2304.9.1—continued FASTENING SCHEDULE
525 SECTION 2305 GENERAL DESIGN REQUIREMENTS FOR LATERAL-FORCE-RESISTING SYSTEMS
EQUATION 23-1
TABLE 2305.2(1) en VALUES (inches) FOR USE IN CALCULATING DIAPHRAGM AND SHEAR WALL DEFLECTION DUE TO FASTENER SLIP (Structural I
526 EQUATION 23-2
TABLE 2305.2(2) VALUES OF Gt FOR USE IN CALCULATING DEFLECTION OF WOOD STRUCTURAL PANEL SHEAR WALLS AND DIAPHRAGMS
527 SECTION 2306 ALLOWABLE STRESS DESIGN
TABLE 2306.1.4 ALLOWABLE LOADS FOR LUMBER DECKING
528 SECTION 2307 LOAD AND RESISTANCE FACTOR DESIGN
SECTION 2308 CONVENTIONAL LIGHT-FRAME CONSTRUCTION
529 TABLE 2306.2.1(1) ALLOWABLE SHEAR (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL DIAPHRAGMS WITH FRAMING OF DOUGLAS FIR-LARCH, OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADINGh
530 TABLE 2306.2.1(1)—continued ALLOWABLE SHEAR (POUNDS PER FOOT) FOR WOOD STRUCTURALPANEL DIAPHRAGMS WITH FRAMING OF DOUGLAS FIR-LARCH,OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADING
531 TABLE 2306.2.1(2) ALLOWABLE SHEAR (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL BLOCKED DIAPHRAGMS UTILIZING MULTIPLE ROWS OF FASTENERS (HIGH LOAD DIAPHRAGMS) WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADING
532 TABLE 2306.2.1(2)—continued ALLOWABLE SHEAR (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL BLOCKED DIAPHRAGMS UTILIZING MULTIPLE ROWS OF FASTENERS (HIGH LOAD DIAPHRAGMS) WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINE FOR WIND OR SEISMIC LOADING
533 TABLE 2306.3 ALLOWABLE SHEAR (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL SHEAR WALLS WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADING
534 TABLE 2306.5 ALLOWABLE SHEAR FOR PARTICLE BOARD SHEAR WALL SHEATHING
TABLE 2306.6 ALLOWABLE SHEAR VALUES (plf) FOR WIND OR SEISMIC LOADING ON SHEAR WALLS OF FIBERBOARD SHEATHING BOARD CONSTRUCTION FOR TYPE V CONSTRUCTION ONLY
535 TABLE 2306.7 ALLOWABLE SHEAR FOR WIND OR SEISMIC FORCES FOR SHEAR WALLS OF LATH AND PLASTER OR GYPSUM BOARD WOOD FRAMED WALL ASSEMBLIES
538 TABLE 2308.8(1) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential Sleeping Areas, Live Load = 30 pounds per square foot, L/Δ = 360)
539 TABLE 2308.8(1)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential Sleeping Areas, Live Load = 30 pounds per square foot, L/Δ = 360)
540 TABLE 2308.8(2) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential Living Areas, Live Load = 40 pounds per square foot, L/Δ = 360)
541 TABLE 2308.8(2) —continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential Living Areas, Live Load = 40 pounds per square foot, L/Δ = 360)
542 TABLE 2308.9.1 SIZE, HEIGHT AND SPACING OF WOOD STUDS
544 FIGURE 2308.9.3 BASIC COMPONENTS OF THE LATERAL BRACING SYSTEM
545 TABLE 2308.9.3(1) BRACED WALL PANELS
TABLE 2308.9.3(2) EXPOSED PLYWOOD PANEL SIDING
TABLE 2308.9.3(3) WOOD STRUCTURAL PANEL WALL SHEATHINGb (Not Exposed to the Weather, Strength Axis Parallel or Perpendicular to Studs Except as Indicated Below)
546 TABLE 2308.9.3(4) ALLOWABLE SPANS FOR PARTICLEBOARD WALL SHEATHING (Not Exposed to the Weather, Long Dimension of the Panel Parallel or Perpendicular to Studs)
TABLE 2308.9.3(5) HARDBOARD SIDING
547 FIGURE 2308.9.3.2 ALTERNATE BRACED WALL PANEL ADJACENT TO A DOOR OR WINDOW OPENING
549 TABLE 2308.9.5HEADER AND GIRDER SPANSa FOR EXTERIOR BEARING WALLS (Maximum Spans for Douglas Fir-Larch, Hem-Fir, Southern Pine and Spruce-Pine-Firb and Required Number of Jack Studs)
550 TABLE 2308.9.5—continued HEADER AND GIRDER SPANSa FOR EXTERIOR BEARING WALLS (Maximum Spans for Douglas Fir-Larch, Hem-Fir, Southern Pine and Spruce-Pine-Firb and Required Number of Jack Studs)
551 TABLE 2308.9.6 HEADER AND GIRDER SPANSa FOR INTERIOR BEARING WALLS (Maximum Spans for Douglas Fir-Larch, Hem-Fir, Southern Pine and Spruce-Pine-Firb and Required Number of Jack Studs)
552 TABLE 2308.10.1 REQUIRED RATING OF APPROVED UPLIFT CONNECTORS (pounds)a, b, c, e, f, g, h
553 TABLE 2308.10.2(1) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable Attics Without Storage, Live Load = 10 pounds per square foot, L/Δ = 240)
554 TABLE 2308.10.2(1)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable Attics Without Storage, Live Load = 10 pounds per square foot, L/Δ = 240)
555 TABLE 2308.10.2(2) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable Attics With Limited Storage, Live Load = 20 pounds per square foot, L/Δ = 240)
556 TABLE 2308.10.2(2)— continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable Attics With Limited Storage, Live Load = 20 pounds per square foot, L/Δ = 240)
557 TABLE 2308.10.3 (1)RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof Live Load = 20 pounds per square foot, Ceiling Not Attached to Rafters, L/Δ = 180)
558 TABLE 2308.10.3(1)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof Live Load = 20 pounds per square foot, Ceiling Not Attached to Rafters, L/Δ = 180)
559 TABLE 2308.10.3(2) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof Live Load = 20 pounds per square foot, Ceiling Not Attached to Rafters, L/Δ = 240)
560 TABLE 2308.10.3(2)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof Live Load = 20 pounds per square foot, Ceiling Not Attached to Rafters, L/Δ = 240)
561 TABLE 2308.10.3(3) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 30 pounds per square foot, Ceiling Not Attached to Rafters, L/Δ = 180)
562 TABLE 2308.10.3(3)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 30 pounds per square foot, Ceiling Not Attached to Rafters, L/Δ = 180)
563 TABLE 2308.10.3(4) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 50 pounds per square foot, Ceiling Not Attached to Rafters, L/Δ = 180)
564 TABLE 2308.10.3(4)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 50 pounds per square foot, Ceiling Not Attached to Rafters, L/Δ = 180)
565 TABLE 2308.10.3(5) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 30 pounds per square foot, Ceiling Attached to Rafters, L/Δ = 240)
566 TABLE 2308.10.3(5)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 30 pounds per square foot, Ceiling Attached to Rafters, L/Δ = 240)
567 TABLE 2308.10.3 (6) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 50 pounds per square foot, Ceiling Attached to Rafters, L/Δ = 240)
568 TABLE 2308.10.3(6)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 50 pounds per square foot, Ceiling Attached to Rafters, L/Δ = 240)
569 TABLE 2308.10.4.1 RAFTER TIE CONNECTIONSg
571 TABLE 2308.10.9 ALLOWABLE SPANS FOR 2-INCH TONGUE-AND-GROOVE DECKING
572 TABLE 2308.10.9–continued ALLOWABLE SPANS FOR 2-INCH TONGUE-AND-GROOVE DECKING
573 FIGURE 2308.11.3.2 STEPPED FOOTING CONNECTION DETAILS
FIGURE 2308.11.3.3 OPENINGS IN HORIZONTAL DIAPHRAGMS
574 TABLE 2308.12.4 WALL BRACING IN SEISMIC DESIGN CATEGORIES D AND E (Minimum Length of Wall Bracing per each 25 Linear Feet of Braced Wall Linea)
575 FIGURE 2308.12.6(1) BRACED WALL PANELS OUT OF PLANE
576 FIGURE 2308.12.6(2) BRACED WALL PANELS SUPPORTED BY CANTILEVER OR SET BACK
FIGURE 2308.12.6(3) FLOOR OR ROOF NOT SUPPORTED ON ALL EDGES
FIGURE 2308.12.6(4) ROOF OR FLOOR EXTENSION BEYOND BRACED WALL LINE
577 FIGURE 2308.12.6(5) BRACED WALL PANEL EXTENSION OVER OPENING
FIGURE 2308.12.6(6) PORTIONS OF FLOOR LEVEL OFFSET VERTICALLY
FIGURE 2308.12.6(7) BRACED WALL LINES NOT PERPENDICULAR
578 FIGURE 2308.12.6(8) OPENING LIMITATIONS FOR FLOOR AND ROOF DIAPHRAGMS
580 CHAPTER 24 – GLASS AND GLAZING
SECTION 2401 GENERAL
SECTION 2402 DEFINITIONS
SECTION 2403 GENERAL REQUIREMENTS FOR GLASS
SECTION 2404 WIND, SNOW, SEISMIC AND DEAD LOADS ON GLASS
EQUATION 24-1
EQUATION 24-2
EQUATION 24-3
581 EQUATION 24-4
EQUATION 24-5
EQUATION 24-6
EQUATION 24-7
EQUATION 24-8
EQUATION 24-9
EQUATION 24-10
EQUATION 24-11
EQUATION 24-12
582 SECTION 2405 SLOPED GLAZING AND SKYLIGHTS
583 EQUATION 24-13
EQUATION 24-14
EQUATION 24-15
SECTION 2406 SAFETY GLAZING
TABLE 2406.2(1) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING CPSC 16 CFR 1201
584 TABLE 2406.2(2) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING ANSI Z97.1
585 SECTION 2407 GLASS IN HANDRAILS AND GUARDS
SECTION 2408 GLAZING IN ATHLETIC FACILITIES
586 SECTION 2409 GLASS IN ELEVATOR HOISTWAYS AND ELEVATOR CARS
588 CHAPTER 25 – GYPSUM BOARD AND PLASTER
SECTION 2501 GENERAL
SECTION 2502 DEFINITIONS
SECTION 2503 INSPECTION
SECTION 2504 VERTICAL AND HORIZONTAL ASSEMBLIES
SECTION 2505 SHEAR WALL CONSTRUCTION
589 SECTION 2506 GYPSUM BOARD MATERIALS
TABLE 2506.2 GYPSUM BOARD MATERIALS AND ACCESSORIES
SECTION 2507 LATHING AND PLASTERING
TABLE 2507.2 LATH, PLASTERING MATERIALS AND ACCESSORIES
SECTION 2508 GYPSUM CONSTRUCTION
TABLE 2508.1 INSTALLATION OF GYPSUM CONSTRUCTION
590 TABLE 2508.5 SHEAR CAPACITY FOR HORIZONTAL WOOD FRAMED GYPSUM BOARD DIAPHRAGM CEILING ASSEMBLIES
SECTION 2509 GYPSUM BOARD IN SHOWERS AND WATER CLOSETS
591 SECTION 2510 LATHING AND FURRING FORCEMENT PLASTER (STUCCO)
SECTION 2511 INTERIOR PLASTER
TABLE 2511.1.1 INSTALLATION OF PLASTER CONSTRUCTION
592 SECTION 2512 EXTERIOR PLASTER
TABLE 2512.6 CEMENT PLASTERS
SECTION 2513 EXPOSED AGGREGATE PLASTER
594 CHAPTER 26 – PLASTIC
SECTION 2601 GENERAL
SECTION 2602 DEFINITIONS
SECTION 2603 FOAM PLASTIC INSULATION
597 FIGURE 2603.8 TERMITE INFESTATION PROBABILITY MAP
SECTION 2604 INTERIOR FINISH AND TRIM
598 SECTION 2605 PLASTIC VENEER
SECTION 2606 LIGHT-TRANSMITTING PLASTICS
599 SECTION 2607 LIGHT-TRANSMITTING PLASTIC WALL PANELS
600 TABLE 2607.4 AREA LIMITATION AND SEPARATION REQUIREMENTS FOR LIGHT-TRANSMITTING PLASTIC WALL PANELS
SECTION 2608 LIGHT-TRANSMITTING PLASTIC GLAZING
SECTION 2609 LIGHT-TRANSMITTING PLASTIC ROOF PANELS
601 TABLE 2609.4 AREA LIMITATIONS FOR LIGHT-TRANSMITTING PLASTIC ROOF PANELS
SECTION 2610 LIGHT-TRANSMITTING PLASTIC SKYLIGHT GLAZING
SECTION 2611 LIGHT-TRANSMITTING PLASTIC INTERIOR SIGNS
602 SECTION 2612 FIBER REINFORCED POLYMER AND FIBERGLASS REINFORCED POLYMER
603 SECTION 2613 REFLECTIVE PLASTIC CORE INSULATION
604 CHAPTER 27 – ELECTRICAL
SECTION 2701 GENERAL
SECTION 2702 EMERGENCY AND STANDBY POWER SYSTEMS
606 CHAPTER 28 – MECHANICAL SYSTEMS
SECTION 2801 GENERAL
608 CHAPTER 29 – PLUMBING SYSTEMS
SECTION 2901 GENERAL
SECTION 2902 MINIMUM PLUMBING FACILITIES
609 TABLE 2902.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES
610 TABLE 2902.1—continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES
611 TABLE 2902.1—continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES
SECTION 2903 TOILET ROOM REQUIREMENTS
614 CHAPTER 30 – ELEVATORS AND CONVEYING SYSTEMS
SECTION 3001 GENERAL
SECTION 3002 HOISTWAY ENCLOSURES
SECTION 3003 EMERGENCY OPERATIONS
615 SECTION 3004 HOISTWAY VENTING
SECTION 3005 CONVEYING SYSTEMS
616 SECTION 3006 MACHINE ROOMS
SECTION 3007 FIRE SERVICE ACCESS ELEVATOR
617 SECTION 3008 OCCUPANT EVACUATION ELEVATORS
620 CHAPTER 31 – SPECIAL CONSTRUCTION
SECTION 3101 GENERAL
SECTION 3102 MEMBRANE STRUCTURES
621 SECTION 3103 TEMPORARY STRUCTURES
SECTION 3104 PEDESTRIAN WALKWAYS AND TUNNELS
622 SECTION 3105 AWNINGS AND CANOPIES
623 SECTION 3106 MARQUEES
SECTION 3107 SIGNS
SECTION 3108 TELECOMMUNICATION AND BROADCAST TOWERS
SECTION 3109 SWIMMING POOL ENCLOSURES AND SAFETY DEVICES
624 SECTION 3110 AUTOMATIC VEHICULAR GATES
626 CHAPTER 32 – ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
SECTION 3201 GENERAL
SECTION 3202 ENCROACHMENTS
628 CHAPTER 33 – SAFEGUARDS DURING CONSTRUCTION
SECTION 3301 GENERAL
SECTION 3302 CONSTRUCTION SAFEGUARDS
SECTION 3303 DEMOLITION
SECTION 3304 SITE WORK
SECTION 3305 SANITARY (Section deleted)
SECTION 3306 PROTECTION OF PEDESTRIANS
629 TABLE 3306.1 PROTECTION OF PEDESTRIANS
630 SECTION 3307 PROTECTION OF ADJOINING PROPERTY
SECTION 3308 TEMPORARY USE OF STREETS, ALLEYS AND PUBLIC PROPERTY
SECTION 3309 FIRE EXTINGUISHERS
SECTION 3310 MEANS OF EGRESS
SECTION 3311 STANDPIPES
631 SECTION 3312 AUTOMATIC SPRINKLER SYSTEM
632 CHAPTER 34 – EXISTING BUILDINGS AND STRUCTURES
SECTION 3401 GENERAL
SECTION 3402 DEFINITIONS
SECTION 3403 ADDITIONS (Section deleted)
SECTION 3404 ALTERATIONS (Section deleted)
SECTION 3405 REPAIRS (Section deleted)
SECTION 3406 FIRE ESCAPES (Section deleted)
SECTION 3407 GLASS REPLACEMENT
633 SECTION 3408 CHANGE OF OCCUPANCY (Section deleted)
SECTION 3409 HISTORIC BUILDINGS
SECTION 3410 MOVED STRUCTURES (Section deleted)
SECTION 3411 ACCESSIBILITY FOR EXISTING BUILDINGS
634 TABLE 3411.8.5 RAMPS
635 SECTION 3412 COMPLIANCE ALTERNATIVES
636 EQUATION 34-1
EQUATION 34-2
EQUATION 34-3
EQUATION 34-4
637 TABLE 3412.6.3 COMPARTMENTATION VALUES
TABLE 3412.6.4 SEPARATION VALUES
638 TABLE 3412.6.5 CORRIDOR WALL VALUES
EQUATION 34-5
TABLE 3412.6.6(1) VERTICAL OPENING PROTECTION VALUE
TABLE 3412.6.6(2) CONSTRUCTION-TYPE FACTOR
TABLE 3412.6.8 AUTOMATIC FIRE DETECTION VALUES
639 TABLE 3412.6.9 FIRE ALARM SYSTEM VALUES
TABLE 3412.6.10 SMOKE CONTROL VALUES
640 TABLE 3412.6.11(1) EGRESS WIDTH PER OCCUPANT SERVED
TABLE 3412.6.11(2) MEANS OF EGRESS VALUES
TABLE 3412.6.12 DEAD-END VALUES
EQUATION 34-6
641 TABLE 3412.6.14 ELEVATOR CONTROL VALUES
TABLE 3412.6.15 MEANS OF EGRESS EMERGENCY LIGHTING VALUES
TABLE 3412.6.16 MIXED OCCUPANCY VALUESa
TABLE 3412.6.17 SPRINKLER SYSTEM VALUES
642 3412.6.18 STANDPIPE SYSTEM VALUES
TABLE 3412.6.19 INCIDENTAL ACCESSORY OCCUPANCY VALUESa
TABLE 3412.8 MANDATORY SAFETY SCORESa
643 TABLE 3412.7 SUMMARY SHEET — BUILDING CODE
644 TABLE 3412.9 EVALUATION FORMULASa
SECTION 3413 RETROFIT REQUIREMENTS
648 CHAPTER 35 – REFERENCED STANDARDS
AA
AAMA
ACI
649 AF&PA
AISC
AISI
AITC
650 ALI
ANSI
APA
651 API
APSP
ASABE
ASCE/SEI
652 ASME
ASTM
658 AWCI
AWPA
AWS
BHMA
CGSB
CPA
659 CPSC
CSA
CSSB
DASMA
DOC
660 DOJ
DOL
DOTn
EN
FEMA
661 FM
GA
HPVA
HUD
ICC
662 ISO
NAAMM
NCMA
663 NFPA
664 PCI
PTI
RMI
SDI
SJI
665 SPRI
TFI
TIA
TMS
TPI
666 UL
667 ULC
USC
WDMA
WR
668 APPENDIX E SUPPLEMENTARY ACCESSIBILITY REQUIREMENTS
SECTION E101 GENERAL
SECTION E102 DEFINITIONS
SECTION E103 ACCESSIBLE ROUTE
SECTION E104 SPECIAL OCCUPANCIES
669 TABLE E104.3.1 DWELLING OR SLEEPING UNITS WITH ACCESSIBLE COMMUNICATION FEATURES
SECTION E105 OTHER FEATURES AND FACILITIES
SECTION E106 TELEPHONES
670 TABLE E106.2 WHEELCHAIR-ACCESSIBLE TELEPHONES
SECTION E107 SIGNAGE
671 SECTION E108 BUS STOPS
SECTION E109 TRANSPORTATION FACILITIES AND STATIONS
672 SECTION E110 AIRPORTS
SECTION E111 REFERENCED STANDARDS
674 APPENDIX F RODENTPROOFING
SECTION F101 GENERAL
676 APPENDIX G FLOOD-RESISTANT CONSTRUCTION
SECTION G101 ADMINISTRATION
SECTION G102 APPLICABILITY
SECTION G103 POWERS AND DUTIES
677 SECTION G104 PERMITS
SECTION G105 VARIANCES
678 SECTION G201 DEFINITIONS
679 SECTION G301 SUBDIVISIONS
SECTION G401 SITE IMPROVEMENT
SECTION G501 MANUFACTURED HOMES
SECTION G601 RECREATIONAL VEHICLES
680 SECTION G701 TANKS
SECTION G801 OTHER BUILDING WORK
SECTION G901 TEMPORARY STRUCTURES AND TEMPORARY STORAGE
SECTION G1001 UTILITY AND MISCELLANEOUS GROUP U
681 SECTION G1101 REFERENCED STANDARDS
682 APPENDIX H SIGNS
SECTION H101 GENERAL
SECTION H102 DEFINITIONS
SECTION H103 LOCATION
SECTION H104 IDENTIFICATION (Section deleted)
SECTION H105 DESIGN AND CONSTRUCTION
683 SECTION H106 ELECTRICAL
SECTION H107 COMBUSTIBLE MATERIALS
SECTION H108 ANIMATED DEVICES
SECTION H109 GROUND SIGNS
SECTION H110 ROOF SIGNS
684 SECTION H111 WALL SIGNS
SECTION H112 PROJECTING SIGNS
SECTION H113 MARQUEE SIGNS
685 SECTION H114 PORTABLE SIGNS
TABLE 4-A SIZE, THICKNESS AND TYPE OF GLASS PANELS IN SIGNS
TABLE 4-B THICKNESS OF PROJECTION SIGN
SECTION H115 REFERENCED STANDARDS (Section deleted)
686 APPENDIX I PATIO COVERS
SECTION I101 GENERAL
SECTION I102 DEFINITIONS
SECTION I103 EXTERIOR OPENINGS
SECTION I104 STRUCTURAL PROVISIONS
688 INDEX
722 GET BACK TO BASICS
723 ES ICC EVALUATION SERVICES
VA VABuildingConstructionCode 2009
$65.54