VA VAMC 2009
$43.33
Virginia Mechanical Code
Published By | Publication Date | Number of Pages |
VA | 2009 | 149 |
This is a fully integrated code based on the 2009 International Mechanical Code®.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | 2009 VIRGINIA MECHANICAL CODE |
2 | 2009 VIRGINIA MECHANICAL CODE EXCERPTS FROM THE VIRGINIA CONSTRUCTION CODE FOR MECHANICAL WORK TITLE PAGE |
3 | COPYRIGHT |
4 | PREFACE |
6 | TABLE OF CONTENTS |
10 | CHAPTER 1 – ADMINISTRATION SECTION 101 GENERAL SECTION 102 PURPOSE AND SCOPE SECTION 103 APPLICATION OF CODE |
12 | SECTION 104 ENFORCEMENT, GENERALLY |
13 | SECTION 105 LOCAL BUILDING DEPARTMENT |
14 | SECTION 106 POWERS AND DUTIES OF THE BUILDING OFFICIAL SECTION 107 FEES SECTION 108 APPLICATION FOR PERMIT |
16 | SECTION 109 CONSTRUCTION DOCUMENTS |
17 | SECTION 110 PERMITS |
18 | SECTION 111 RDP SERVICES SECTION 112 WORKMANSHIP, MATERIALS AND EQUIPMENT |
19 | SECTION 113 INSPECTIONS |
20 | SECTION 114 STOP WORK ORDERS SECTION 115 VIOLATIONS |
21 | SECTION 116 CERTIFICATES OF OCCUPANCY SECTION 117 TEMPORARY AND MOVED BUILDINGS AND STRUCTURES; DEMOLITION |
22 | SECTION 118 BUILDINGS AND STRUCTURES BECOMING UNSAFE DURING CONSTRUCTION SECTION 119 APPEALS |
26 | CHAPTER 2 – DEFINITIONS SECTION 201 GENERAL SECTION 202 GENERAL DEFINITIONS |
36 | CHAPTER 3 – GENERAL REGULATIONS SECTION 301 GENERAL |
37 | SECTION 302 PROTECTION OF STRUCTURE |
38 | SECTION 303 EQUIPMENT AND APPLIANCE LOCATION SECTION 304 INSTALLATION |
39 | SECTION 305 PIPING SUPPORT |
40 | TABLE 305.4 PIPING SUPPORT SPACING SECTION 306 ACCESS AND SERVICE SPACE |
41 | SECTION 307 CONDENSATE DISPOSAL |
42 | TABLE 307.2.2 CONDENSATE DRAIN SIZING SECTION 308 CLEARANCE REDUCTION |
43 | TABLE 308.6 CLEARANCE REDUCTION METHODS |
44 | SECTION 309 TEMPERATURE CONTROL SECTION 310 EXPLOSION CONTROL SECTION 311 SMOKE AND HEAT VENTS SECTION 312 HEATING AND COOLING LOAD CALCULATIONS |
46 | CHAPTER 4 – VENTILATION SECTION 401 GENERAL TABLE 401.5 OPENING SIZES IN LOUVERS, GRILLES AND SCREENS PROTECTING AIR IN TAKE OPENINGS SECTION 402 NATURAL VENTILATION |
47 | SECTION 403 MECHANICAL VENTILATION EQUATION 4-1 |
48 | TABLE 403.3 MINIMUM VENTILATION RATES |
49 | TABLE 403.3—continued MINIMUM VENTILATION RATES |
50 | TABLE 403.3—continued MINIMUM VENTILATION RATES |
51 | TABLE 403.3.1.2 ZONE AIR DISTRIBUTION EFFECTIVENESS EQUATION 4-2 EQUATION 4-3 EQUATION 4-4 EQUATION 4-5 TABLE 403.3.2.3.2 SYSTEM VENTILATION EFFICIENCY EQUATION 4-6 EQUATION 4-7 |
52 | EQUATION 4-8 SECTION 404 ENCLOSED PARKING GARAGES SECTION 405 SYSTEMS CONTROL SECTION 406 VENTILATION OF UNINHABITED SPACES |
54 | CHAPTER 5 – EXHAUST SYSTEMS SECTION 501 GENERAL SECTION 502 REQUIRED SYSTEMS |
55 | EQUATION 5-1 |
61 | SECTION 503 MOTORS AND FANS SECTION 504 CLOTHES DRYER EXHAUST |
62 | TABLE 504.6.4.1 DRYER EXHAUST DUCT FITTING EQUIVALENT LENGTH |
63 | SECTION 505 DOMESTIC KITCHEN EXHAUST EQUIPMENT SECTION 506 COMMERCIAL KITCHEN HOOD VENTILATION SYSTEM DUCTS AND EXHAUST EQUIPMENT |
67 | SECTION 507 COMMERCIAL KITCHEN HOODS |
68 | TABLE 507.11 MINIMUM DISTANCE BETWEEN THE LOWEST EDGE OF A GREASE FILTER AND THE COOKING SURFACE OR THE HEATING SURFACE |
69 | SECTION 508 COMMERCIAL KITCHEN MAKEUP AIR SECTION 509 FIRE SUPPRESSION SYSTEMS SECTION 510 HAZARDOUS EXHAUST SYSTEMS |
71 | TABLE 510.8 MINIMUM DUCT THICKNESS TABLE 510.8.2 CLEARANCE TO COMBUSTIBLES SECTION 511 DUST, STOCK AND REFUSE CONVEYING SYSTEMS |
72 | TABLE 511.2 CONSTRUCTION, CLEARANCE AND TERMINATION REQUIREMENTS FOR SINGLE-WALL METAL CHIMNEYS SECTION 512 SUBSLAB SOIL EXHAUST SYSTEMS |
73 | SECTION 513 SMOKE CONTROL SYSTEMS |
74 | EQUATION 5-2 EQUATION 5-3 |
75 | EQUATION 5-4 |
76 | SECTION 514 ENERGY RECOVERY VENTILATION SYSTEMS |
78 | CHAPTER 6 – DUCT SYSTEMS SECTION 601 GENERAL SECTION 602 PLENUMS |
80 | SECTION 603 DUCT CONSTRUCTION AND INSTALLATION TABLE 603.4 DUCT CONSTRUCTION MINIMUM SHEET METAL THICKNESSES FOR SINGLE DWELLING UNITS |
81 | SECTION 604 INSULATION |
82 | SECTION 605 AIR FILTERS SECTION 606 SMOKE DETECTION SYSTEMS CONTROL |
83 | SECTION 607 DUCT AND TRANSFER OPENINGS |
84 | TABLE 607.3.2.1 FIRE DAMPER RATING |
88 | CHAPTER 7 – COMBUSTION AIR SECTION 701 GENERAL |
90 | CHAPTER 8 – CHIMNEYS AND VENTS SECTION 801 GENERAL |
91 | SECTION 802 VENTS TABLE 802.2 VENT APPLICATION |
92 | SECTION 803 CONNECTORS TABLE 803.9(1) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR LOW-HEAT APPLIANCES TABLE 803.9(2) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR MEDIUM- AND HIGH-HEAT APPLIANCES |
93 | TABLE 803.10.4 CHIMNEY CONNECTOR SYSTEMS AND CLEARANCES TO COMBUSTIBLE WALL MATERIALS FOR DOMESTIC HEATING APPLIANCES TABLE 803.10.6 CONNECTOR CLEARANCES TO COMBUSTIBLES SECTION 804 DIRECT-VENT, INTEGRAL VENT AND MECHANICAL DRAFT SYSTEMS |
94 | SECTION 805 FACTORY-BUILT CHIMNEYS |
95 | SECTION 806 METAL CHIMNEYS |
96 | CHAPTER 9 – SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT SECTION 901 GENERAL SECTION 902 MASONRY FIREPLACES SECTION 903 FACTORY-BUILT FIREPLACES SECTION 904 PELLET FUEL-BURNING APPLIANCES SECTION 905 FIREPLACE STOVES AND ROOM HEATERS SECTION 906 FACTORY-BUILT BARBECUE APPLIANCES SECTION 907 INCINERATORS AND CREMATORIES SECTION 908 COOLING TOWERS, EVAPORATIVE CONDENSERS AND FLUID COOLERS |
97 | SECTION 909 VENTED WALL FURNACES SECTION 910 FLOOR FURNACES SECTION 911 DUCT FURNACES SECTION 912 INFRARED RADIANT HEATERS SECTION 913 CLOTHES DRYERS |
98 | SECTION 914 SAUNA HEATERS SECTION 915 ENGINE AND GAS TURBINE-POWERED EQUIPMENT AND APPLIANCES SECTION 916 POOL AND SPA HEATERS SECTION 917 COOKING APPLIANCES SECTION 918 FORCED-AIR WARM-AIR FURNACES |
99 | SECTION 919 CONVERSION BURNERS SECTION 920 UNIT HEATERS |
100 | SECTION 921 VENTED ROOM HEATERS SECTION 922 KEROSENE AND OIL-FIRED STOVES SECTION 923 SMALL CERAMIC KILNS SECTION 924 STATIONARY FUEL CELL POWER SYSTEMS SECTION 925 MASONRY HEATERS SECTION 926 GASEOUS HYDROGEN SYSTEMS SECTION 927 HEAT RECOVERY VENTILATORS |
102 | CHAPTER 10 – BOILERS, WATER HEATERS AND PRESSURE VESSELS SECTION 1001 GENERAL SECTION 1002 WATER HEATERS SECTION 1003 PRESSURE VESSELS SECTION 1004 BOILERS |
103 | SECTION 1005 BOILER CONNECTIONS SECTION 1006 SAFETY AND PRESSURE RELIEF VALVES AND CONTROLS SECTION 1007 BOILER LOW-WATER CUTOFF |
104 | SECTION 1008 STEAM BLOWOFF VALVE SECTION 1009 HOT WATER BOILER EXPANSION TANK EQUATION 10-1 SECTION 1010 GAUGES SECTION 1011 TESTS |
106 | CHAPTER 11 – REFRIGERATION SECTION 1101 GENERAL SECTION 1102 SYSTEM REQUIREMENTS |
107 | SECTION 1103 REFRIGERATION SYSTEM CLASSIFICATION SECTION 1104 SYSTEM APPLICATION REQUIREMENTS |
108 | TABLE 1103.1 REFRIGERANT CLASSIFICATION, AMOUNT AND OEL |
109 | TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL |
110 | TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL |
111 | TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL |
112 | TABLE 1104.3.2 MAXIMUM PERMISSIBLE QUANTITIES OF REFRIGERANTS |
113 | SECTION 1105 MACHINERY ROOM, GENERAL REQUIREMENTS EQUATION 11-1 |
114 | EQUATION 11-2 SECTION 1106 MACHINERY ROOM, SPECIAL REQUIREMENTS SECTION 1107 REFRIGERANT PIPING |
116 | SECTION 1108 FIELD TEST SECTION 1109 PERIODIC TESTING |
118 | CHAPTER 12 – HYDRONIC PIPING SECTION 1201 GENERAL SECTION 1202 MATERIAL TABLE 1202.4 HYDRONIC PIPE TABLE 1202.4—continued HYDRONIC PIPE TABLE 1202.5 HYDRONIC PIPE FITTINGS |
119 | SECTION 1203 JOINTS AND CONNECTIONS |
120 | SECTION 1204 PIPE INSULATION |
121 | SECTION 1205 VALVES SECTION 1206 PIPING INSTALLATION SECTION 1207 TRANSFER FLUID SECTION 1208 TESTS |
122 | SECTION 1209 EMBEDDED PIPING |
124 | CHAPTER 13 – FUEL OIL PIPING AND STORAGE SECTION 1301 GENERAL SECTION 1302 MATERIAL TABLE 1302.3 FUEL OIL PIPING SECTION 1303 JOINTS AND CONNECTIONS |
125 | SECTION 1304 PIPING SUPPORT SECTION 1305 FUEL OIL SYSTEM INSTALLATION |
126 | SECTION 1306 OIL GAUGING SECTION 1307 FUEL OIL VALVES SECTION 1308 TESTING |
128 | CHAPTER 14 – SOLAR SYSTEMS SECTION 1401 GENERAL SECTION 1402 INSTALLATION |
129 | SECTION 1403 HEAT TRANSFER FLUIDS SECTION 1404 MATERIALS |
130 | CHAPTER 15 – REFERENCED STANDARDS ACCA AHRI ANSI ASHRAE ASME |
131 | ASSE ASTM |
132 | AWS |
133 | AWWA CSA DOL FS ICC |
134 | IIAR MSS NAIMA NFPA |
135 | SMACNA UL |
138 | APPENDIX A COMBUSTION AIR OPENINGS AND CHIMNEY CONNECTOR PASS-THROUGHS FIGURE A-1 ALL AIR FROM INSIDE THE BUILDING FIGURE A-2 ALL AIR FROM OUTDOORS—INLET AIR FROM VENTILATED CRAWL SPACE AND OUTLET AIR TO VENTILATED ATTIC |
139 | FIGURE A-3 ALL AIR FROM OUTDOORS THROUGH VENTILATED ATTIC FIGURE A-4 ALL AIR FROM OUTDOORS THROUGH HORIZONTAL DUCTS OR DIRECT OPENINGS |
140 | FIGURE A-5 CHIMNEY CONNECTOR SYSTEMS |
141 | FIGURE A-5—continued CHIMNEY CONNECTOR SYSTEMS |
142 | APPENDIX B RECOMMENDED PERMIT FEE SCHEDULE B101 MECHANICAL WORK, OTHER THAN GAS PIPING SYSTEMS B102 FEE FOR REINSPECTION B103 TEMPORARY OPERATION INSPECTION FEE B104 SELF-CONTAINED UNITS LESS THAN 2 TONS |
144 | INDEX |
148 | ICC-ES PMG PROGRAM |
149 | INCREASE YOUR CODE KNOWLEDGE |