VT CBES 2020
$34.45
Vermont Commercial Building Energy Standards (CBES) effective September 1, 2020
Published By | Publication Date | Number of Pages |
VT | 2020 |
None
PDF Catalog
PDF Pages | PDF Title |
---|---|
7 | PREFACE Introduction Development Background Update Process |
8 | EFFECTIVE USE OF THE 2020 VERMONT COMMERCIAL BUILDING ENERGY STANDARDS Arrangement and Format of the 2020 CBES Italicized Terms |
10 | Marginal Markings Abbreviations and Notations |
23 | – add – C302.2 Climatic data0F . |
24 | TABLE C303.1.3(1) DEFAULT GLAZED WINDOW, GLASS DOOR AND SKYLIGHT U-FACTORS |
25 | TABLE 4.2.1.1 Building Performance Factor (BPF) |
30 | SECTION C402 BUILDING ENVELOPE REQUIREMENTS |
31 | TABLE C402.1(1) |
33 | TABLE C402.1(2) BUILDING ENVELOPE REQUIREMENTS—METAL BUILDING ASSEMBLY DESCRIPTIONS |
34 | TABLE C402.1(3) ASSEMBLY U-FACTORS FOR METAL BUILDING ROOFS |
35 | – add – TABLE C402.1(4) ASSEMBLY U-FACTORS FOR ATTIC ROOFS WITH WOOD JOISTS TABLE C402.1(4) ASSEMBLY U-FACTORS FOR ATTIC ROOFS WITH WOOD JOISTS |
36 | TABLE C402.1(5) ASSEMBLY U-FACTORS FOR METAL BUILDING WALLS |
37 | TABLE C402.1(6) ASSEMBLY U-FACTORS FOR METAL-FRAMED WALLS |
38 | – add – TABLE C402.1(7) ASSEMBLY U-FACTORS FOR WOOD-FRAMED WALLS TABLE C402.1(7) ASSEMBLY U-FACTORS FOR WOOD-FRAMED WALLS |
42 | TABLE C402.3 BUILDING ENVELOPE FENESTRATION MAXIMUM U-FACTOR AND SHGC REQUIREMENTS – delete – TABLE C402.4 BUILDING ENVELOPE FENESTRATION MAXIMUM U-FACTOR AND SHGC REQUIREMENTS |
46 | – add – C402.4.1.2 Continuous Air Barrier Commissioning – add – C402.4.1.2.1 Building Envelope Commissioning Guideline |
47 | TABLE C402.4.1.2.1 BUILDING ENVELOPE COMMISIONING CHECKLIST |
53 | SECTION C403 BUILDING MECHANICAL SYSTEMS |
55 | – delete and replace – TABLE C403.3.2(1) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS TABLE C403.3.2(1) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS |
56 | TABLE C403.3.2(1)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS |
57 | – delete and replace – TABLE C403.3.2(2) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS TABLE C403.3.2(2) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS |
58 | TABLE C403.3.2(2)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS |
59 | – delete and replace – TABLE C403.3.2(7) WATER CHILLING PACKAGES – EFFICIENCY REQUIREMENTS TABLE C403.3.2(7) WATER CHILLING PACKAGES – EFFICIENCY REQUIREMENTSa, b, d |
60 | TABLE C403.3.2(10) MINIMUM EFFICIENCY ELECTRICALLY OPERATED VARIABLE-REFRIGERANT-FLOW AIR CONDITIONERS |
61 | – add – TABLE C403.3.2(11) MINIMUM EFFICIENCY ELECTRICALLY OPERATED VARIABLE-REFRIGERANT-FLOW AIR-TO-AIR AND APPLIED HEAT PUMPS TABLE C403.3.2(11) MINIMUM EFFICIENCY ELECTRICALLY OPERATED VARIABLE-REFRIGERANT-FLOW AIR-TO-AIR AND APPLIED HEAT PUMPS |
62 | – modify – TABLE C403.3.2(10) HEAT TRANSFER EQUIPMENT to TABLE C403.3.2(12) HEAT TRANSFER EQUIPMENT |
65 | – delete – TABLE C403.4.4 VARIABLE SPEED DRIVE (VSD) REQUIREMENTS FOR DEMAND-CONTROLLED PUMPS |
66 | MINIMUM CHILLED-WATER SYSTEM COOLING CAPACITY FOR DETERMINING ECONOMIZER COOLING REQUIREMENTS |
67 | – delete and replace – TABLE C403.5.1 DX COOLING STAGE REQUIREMENTS FOR MODULATING AIRFLOW UNITSTABLE C403.5.1 DX COOLING STAGE REQUIREMENTS FOR MODULATING AIRFLOW UNITS – delete and replace – TABLE C403.5.3.3 HIGH-LIMIT SHUTOFF CONTROL SETTING FOR AIR ECONOMIZERSbTABLE C403.5.3.3 HIGH-LIMIT SHUTOFF CONTROL SETTING FOR AIR ECONOMIZERSb |
75 | – delete and replace – TABLE C403.8.5.1 COOLING SYSTEMS TABLE C403.8.5.1 COOLING SYSTEMS |
80 | – delete and replace – TABLE C403.11.3 MINIMUM PIPE INSULATION THICKNESS (in inches) TABLE C403.11.3 MINIMUM PIPE INSULATION THICKNESS (in inches)a, c |
82 | TABLE C404.2 MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT |
83 | TABLE C404.2—continued MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT |
86 | – delete and replace – C405.2.1.4 Occupant sensor control function for egress illumination. |
89 | – add – C405.2.3.1.1 Dimming. |
91 | FIGURE C405.2.3.3(4) DAYLIGHT ZONE ADJACENT TO CLERESTORY FENESTRATION IN A WALL |
94 | TABLE C405.3.2(1) INTERIOR LIGHTING POWER ALLOWANCES: BUILDING AREA METHOD |
95 | – delete and replace – TABLE C405.3.2(2) INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD TABLE C405.3.2(2) INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD |
96 | TABLE C405.3.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD |
97 | TABLE C405.3.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD |
98 | TABLE C405.3.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD |
99 | TABLE C405.4.2(1) EXTERIOR LIGHTING ZONES |
100 | TABLE C405.4.2(2) INDIVIDUAL LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS |
101 | – delete – TABLE C405.4.2(3) INDIVIDUAL LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS – add – C405.10 Electric Vehicle Charging Stations |
102 | TABLE C405.11 ELECTRIC VEHICLE CHARGING PARKING SPACES |
111 | – modify – FIGURE C408.2.4 COMMISSIONING COMPLIANCE CHECKLIST to FIGURE C407.2.4 COMMISSIONING COMPLIANCE CHECKLIST |
117 | APPENDIX CA SOLAR-READY ZONE—COMMERCIAL SECTION CA103 SOLAR-READY ZONE |