Shopping Cart

No products in the cart.

VT CommercialEnergyCode 2020 1stprint

$14.08

Vermont Commercial Building Energy Standards

Published By Publication Date Number of Pages
VT 2020
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

Custom code based on the Commercial provisions of the 2018 International Energy Conservation Code, first printing.

PDF Catalog

PDF Pages PDF Title
1 2020 VERMONT COMMERCIAL BUILDING ENERGY STANDARDS
2 2020 VERMONT COMMERCIAL BUILDING ENERGY STANDARDS TITLE PAGE
3 COPYRIGHT
4 PREFACE
6 EFFECTIVE USE OF THE 2020 VERMONT COMMERCIAL BUILDING ENERGY STANDARDS
10 IECC—COMMERCIAL PROVISIONS TABLE OF CONTENTS
12 CHAPTER 1 [CE] SCOPE AND ADMINISTRATION
PART 1—SCOPE AND APPLICATION
SECTION C101 SCOPE AND GENERAL REQUIREMENTS
13 SECTION C102 ALTERNATIVE MATERIALS, DESIGN AND METHODS OF CONSTRUCTION AND EQUIPMENT
PART 2—ADMINISTRATION AND ENFORCEMENT
SECTION C103 CONSTRUCTION DOCUMENTS
14 SECTION C104 RESERVED
SECTION C105 INSPECTIONS
15 SECTION C106 VALIDITY
SECTION C107 REFERENCED STANDARDS
SECTION C108 RESERVED
SECTION C109 RESERVED
16 CHAPTER 2 [CE] DEFINITIONS
SECTION C201 GENERAL
SECTION C202 GENERAL DEFINITIONS
24 CHAPTER 3 [CE] GENERAL REQUIREMENTS
SECTION C301 CLIMATE ZONES
SECTION C302 DESIGN CONDITIONS
SECTION C303 MATERIALS, SYSTEMS AND EQUIPMENT
25 TABLE C303.1.3(1) DEFAULT GLAZED WINDOW, GLASS DOOR AND SKYLIGHT U-FACTORS
TABLE C303.1.3(2) DEFAULT OPAQUE DOOR U-FACTORS
TABLE C303.1.3(3) DEFAULT GLAZED FENESTRATION SHGC AND VT
26 CHAPTER 4 [CE] COMMERCIAL ENERGY EFFICIENCY
SECTION C401 GENERAL
TABLE 4.2.1.1 BUILDING PERFORMANCE FACTOR (BPF)
28 SECTION C402 BUILDING ENVELOPE REQUIREMENTS
29 EQUATION 4-1
30 TABLE C402.1(1) BUILDING ENVELOPE REQUIREMENTS—OPAQUE ASSEMBLIES AND ELEMENTS
31 TABLE C402.1(2) BUILDING ENVELOPE REQUIREMENTS—METAL BUILDING ASSEMBLY DESCRIPTIONS
32 TABLE C402.1(3) ASSEMBLY U-FACTORS FOR METAL BUILDING ROOFS
33 TABLE C402.1(4) ASSEMBLY U-FACTORS FOR ATTIC ROOFS WITH WOOD JOISTS
34 TABLE C402.1(5) ASSEMBLY U-FACTORS FOR METAL BUILDING WALLS
35 TABLE C402.1(6) ASSEMBLY U-FACTORS FOR METAL-FRAMED WALLS
36 TABLE C402.1(7) ASSEMBLY U-FACTORS FOR WOOD-FRAMED WALLS
37 EQUATION 4-2
38 TABLE C402.3 BUILDING ENVELOPE FENESTRATION MAXIMUM U-FACTOR AND SHGC REQUIREMENTS
EQUATION 4-3
39 EQUATION 4-4
41 TABLE C402.4.1.2.1 BUILDING ENVELOPE COMMISIONING CHECKLIST
42 TABLE C402.4.1.5 MAXIMUM AIR LEAKAGE RATE FOR FENESTRATION ASSEMBLIES
44 SECTION C403 BUILDING MECHANICAL SYSTEMS
45 EQUATION 4-5
EQUATION 4-6
46 TABLE C403.3.2(1) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS
47 TABLE C403.3.2(1)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS
48 TABLE C403.3.2(2) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS
49 TABLE C403.3.2(2)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS
50 TABLE C403.3.2(3) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS
51 TABLE C403.3.2(3)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS
TABLE C403.3.2(4) WARM-AIR FURNACES AND COMBINATION WARM-AIR FURNACES/AIR-CONDITIONING UNITS, WARM-AIR DUCT FURNACES AND UNIT HEATERS, MINIMUM EFFICIENCY REQUIREMENTS
52 TABLE C403.3.2(5) MINIMUM EFFICIENCY REQUIREMENTS: GAS- AND OIL-FIRED BOILERS
TABLE C403.3.2(6) MINIMUM EFFICIENCY REQUIREMENTS: CONDENSING UNITS, ELECTRICALLY OPERATED
53 TABLE C403.3.2(7) WATER CHILLING PACKAGES – EFFICIENCY REQUIREMENTS
54 TABLE C403.3.2(8) MINIMUM EFFICIENCY REQUIREMENTS: HEAT REJECTION EQUIPMENT
55 TABLE C403.3.2(9) MINIMUM EFFICIENCY AIR CONDITIONERS AND CONDENSING UNITS SERVING COMPUTER ROOMS
TABLE C403.3.2(10) MINIMUM EFFICIENCY ELECTRICALLY OPERATED VARIABLE-REFRIGERANT-FLOW AIR CONDITIONERS
56 TABLE C403.3.2(11) MINIMUM EFFICIENCY ELECTRICALLY OPERATED VARIABLE-REFRIGERANT-FLOW AIR-TO-AIR AND APPLIED HEAT PUMPS
57 TABLE C403.3.2(11)—(continued) MINIMUM EFFICIENCY ELECTRICALLY OPERATED VARIABLE-REFRIGERANT-FLOW AIR-TO-AIR AND APPLIED HEAT PUMPS
TABLE C403.3.2(12) HEAT TRANSFER EQUIPMENT
59 TABLE C403.5 MINIMUM CHILLED-WATER SYSTEM COOLING CAPACITY FOR DETERMINING ECONOMIZER COOLING REQUIREMENTS
60 TABLE C403.5.1 DX COOLING STAGE REQUIREMENTS FOR MODULATING AIRFLOW UNITS
TABLE C403.5.3.3 HIGH-LIMIT SHUTOFF CONTROL SETTING FOR AIR ECONOMIZERSb
63 TABLE C403.7.4 ENERGY RECOVERY REQUIREMENT (Air systems operating not less than 3,000 hours per year)
64 TABLE C403.7.5 MAXIMUM NET EXHAUST FLOW RATE, CFM PER LINEAR FOOT OF HOOD LENGTH
65 TABLE C403.8.1(1) FAN POWER LIMITATION
TABLE C403.8.1(2) FAN POWER LIMITATION PRESSURE DROP ADJUSTMENT
66 TABLE C403.8.5.1 COOLING SYSTEMS
68 TABLE C403.10.1(1) MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATION
TABLE C403.10.1(2) MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATORS AND FREEZERS
69 TABLE C403.10.1(2)—continued MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATORS AND FREEZERS
70 TABLE C403.10.1(3) WALK-IN COOLER AND FREEZER DISPLAY DOOR EFFICIENCY REQUIREMENTSa
TABLE C403.10.1(4) WALK-IN COOLER AND FREEZER NONDISPLAY DOOR EFFICIENCY REQUIREMENTSa
TABLE C403.10.1(5) WALK-IN COOLER AND FREEZER REFRIGERATION SYSTEM EFFICIENCY REQUIREMENTS
71 EQUATION 4-7
72 TABLE C403.11.3 MINIMUM PIPE INSULATION THICKNESS
SECTION C404 SERVICE WATER HEATING (MANDATORY)
74 TABLE C404.2 MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT
75 TABLE C404.2—continued MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT
76 SECTION C405 ELECTRICAL POWER AND LIGHTING SYSTEMS
78 EQUATION 4-8
80 FIGURE C405.2.3.2 SIDELIT ZONE
FIGURE C405.2.3.3(1) TOPLIT ZONE
FIGURE C405.2.3.3(2) DAYLIGHT ZONE UNDER A ROOFTOP MONITOR
81 FIGURE C405.2.3.3(3) DAYLIGHT ZONE UNDER A SLOPED ROOFTOP MONITOR
FIGURE C405.2.3.3(4) DAYLIGHT ZONE ADJACENT TO CLERESTORY FENESTRATION IN A WALL
82 EQUATION 4-9
83 TABLE C405.3.2(1) INTERIOR LIGHTING POWER ALLOWANCES: BUILDING AREA METHOD
TABLE C405.3.2(2) INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
84 TABLE C405.3.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
TABLE C405.3.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
85 EQUATION 4-10
86 TABLE C405.6 MINIMUM NOMINAL EFFICIENCY LEVELS FOR 10 CFR 431 LOW-VOLTAGE DRY-TYPE DISTRIBUTION TRANSFORMERS
TABLE C405.4.2(1) EXTERIOR LIGHTING ZONES
87 TABLE C405.4.2(2) LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS
88 TABLE C405.7(1) MINIMUM NOMINAL FULL-LOAD EFFICIENCY FOR NEMA DESIGN A, NEMA DESIGN B, AND IEC DESIGN N MOTORS (EXCLUDING FIRE PUMP) ELECTRIC MOTORS AT 60 HZ
89 TABLE C405.7(2) MINIMUM NOMINAL FULL-LOAD EFFICIENCY FOR NEMA DESIGN C AND IEC DESIGN H MOTORS AT 60 HZ
TABLE C405.7(3) MINIMUM AVERAGE FULL-LOAD EFFICIENCY POLYPHASE SMALL ELECTRIC MOTORSa
90 TABLE C405.7(4) MINIMUM AVERAGE FULL-LOAD EFFICIENCY FOR CAPACITOR-START CAPACITOR-RUN AND CAPACITOR-START INDUCTION-RUN SMALL ELECTRIC MOTORSa
91 TABLE C405.11 ELECTRICAL VEHICLE CHARGING PARKING SPACES
SECTION C406 ADDITIONAL EFFICIENCY PACKAGE OPTIONS
92 TABLE C406.1 EFFICIENCY PACKAGE CREDITS
93 TABLE C406.5 EXTERIOR LIGHTING ZONES
94 SECTION C407 MAINTENANCE INFORMATION AND SYSTEM COMMISSIONING
98 FIGURE C407.2.4 COMMISSIONING COMPLIANCE CHECKLIST
100 CHAPTER 5 [CE] EXISTING BUILDINGS
SECTION C501 GENERAL
SECTION C502 ADDITIONS
101 SECTION C503 ALTERATIONS
102 SECTION C504 REPAIRS
SECTION C505 CHANGE OF OCCUPANCY OR USE
104 CHAPTER 6 [CE] REFERENCED STANDARDS
AAMA
AHAM
AHRI
105 AMCA
ANSI
APSP
ASHRAE
106 ASME
ASTM
107 CRRC
CSA
CTI
DASMA
DOE
108 ICC
IEEE
IES
ISO
109 NEMA
NFPA
NFRC
SMACNA
UL
US-FTC
110 WDMA
112 APPENDIX CA SOLAR-READY ZONE—COMMERCIAL
SECTION CA101 SCOPE
SECTION CA102 GENERAL DEFINITION
SECTION CA103 SOLAR-READY ZONE
114 INDEX
VT CommercialEnergyCode 2020 1stprint
$14.08