VT VermontCommercialBuildingEnergyStandards 2015
$13.54
Vermont Commercial Building Energy Standards
Published By | Publication Date | Number of Pages |
VT | 2015 | 104 |
Custom code based on the Commercial provisions of the 2015 International Energy Conservation Code.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | 2015 VERMONT COMMERCIAL BUILDING ENERGY STANDARDS |
2 | 2015 VERMONT COMMERCIAL BUILDING ENERGY STANDARDS TITLE PAGE |
3 | COPYRIGHT |
5 | PREFACE |
7 | EFFECTIVE USE OF THE COMMERCIAL BUILDING ENERGY STANDARDS |
11 | TABLE OF CONTENTS |
13 | CHAPTER 1 [CE] SCOPE AND ADMINISTRATION PART 1—SCOPE AND APPLICATION SECTION C101 SCOPE AND GENERAL REQUIREMENTS |
14 | SECTION C102 ALTERNATE MATERIALS—METHOD OF CONSTRUCTION, DESIGN OR INSULATING SYSTEMS PART 2—ADMINISTRATION AND ENFORCEMENT SECTION C103 CONSTRUCTION DOCUMENTS |
15 | SECTION C104 INSPECTIONS SECTION C105 VALIDITY |
16 | SECTION C106 REFERENCED STANDARDS |
17 | CHAPTER 2 [CE] DEFINITIONS SECTION C201 GENERAL SECTION C202 GENERAL DEFINITIONS |
23 | CHAPTER 3 [CE] GENERAL REQUIREMENTS SECTION C301 CLIMATE ZONE SECTION C302 DESIGN CONDITIONS SECTION C303 MATERIALS, SYSTEMS AND EQUIPMENT TABLE C303.1.3(1) DEFAULT GLAZED FENESTRATION U-FACTORS |
24 | TABLE C303.1.3(2) DEFAULT DOOR U-FACTORS TABLE C303.1.3(3) DEFAULT GLAZED FENESTRATION SHGC AND VT |
25 | CHAPTER 4 COMMERCIAL ENERGY EFFICIENCY SECTION C401 GENERAL |
26 | SECTION C402 BUILDING ENVELOPE REQUIREMENTS |
27 | TABLE C402.1 BUILDING ENVELOPE REQUIREMENTS—OPAQUE ASSEMBLIES AND ELEMENTS |
28 | EQUATION 4-1 TABLE 402.1(2) BUILDING ENVELOPE REQUIREMENTS—METAL BUILDING ASSEMBLY DESCRIPTIONS |
29 | TABLE C402.1(3) ASSEMBLY U-FACTORS FOR METAL BUILDING ROOFS |
30 | TABLE C402.1(4) ASSEMBLY U-FACTORS FOR METAL BUILDING WALLS |
31 | TABLE C402.3 BUILDING ENVELOPE FENESTRATION MAXIMUM U-FACTOR AND SHGC REQUIREMENTS EQUATION 4-2 |
32 | EQUATION 4-3 |
34 | TABLE C402.4.2 MAXIMUM AIR LEAKAGE RATE FOR FENESTRATION ASSEMBLIES |
35 | SECTION C403 BUILDING MECHANICAL SYSTEMS |
36 | TABLE C403.2.3(1) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS |
37 | TABLE C403.2.3(1)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS |
38 | TABLE C403.2.3(2) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS |
39 | TABLE C403.2.3(2)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS |
40 | TABLE C403.2.3(3) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS,SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS |
41 | TABLE C403.2.3(3)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS TABLE 403.2.3(4) WARM-AIR FURNACES AND COMBINATION WARM-AIR FURNACES/AIR-CONDITIONING UNITS, WARM-AIR DUCT FURNACES AND UNIT HEATERS, MINIMUM EFFICIENCY REQUIREMENTS |
42 | TABLE C403.2.3(5) MINIMUM EFFICIENCY REQUIREMENTS: GAS- AND OIL-FIRED BOILERS |
43 | TABLE C403.2.3(7) WATER CHILLING PACKAGES – EFFICIENCY REQUIREMENTS |
44 | TABLE C403.2.3(8) MINIMUM EFFICIENCY REQUIREMENTS: HEAT REJECTION EQUIPMENT |
45 | TABLE C403.2.3(9)a MINIMUM EFFICIENCY AIR CONDITIONERS AND CONDENSING UNITS SERVING COMPUTER ROOMS TABLE C403.2.3(10) MINIMUM EFFICIENCY ELECTRICALLY OPERATED VARIABLE-REFRIGERANT-FLOW AIR CONDITIONERS |
46 | TABLE C403.2.3(11) MINIMUM EFFICIENCY ELECTRICALLY OPERATED VARIABLE-REFRIGERANT-FLOW AIR-TO-AIR AND APPLIED HEAT PUMPS |
47 | TABLE C403.2.3(11)—continued MINIMUM EFFICIENCY ELECTRICALLY OPERATED VARIABLE-REFRIGERANT-FLOW AIR-TO-AIR AND APPLIED HEAT PUMPS |
48 | EQUATION 4-4 EQUATION 4-5 |
51 | TABLE C403.2.7(1) ENERGY RECOVERY REQUIREMENT (Ventilation systems operating less than 8,000 hours per year) TABLE C403.2.8 MAXIMUM NET EXHAUST FLOW RATE, CFM PER LINEAR FOOT OF HOOD LENGTH |
52 | EQUATION 4-6 |
53 | TABLE C403.2.10c MINIMUM PIPE INSULATION THICKNESS (in inches) |
54 | TABLE C403.2.12.1(1) FAN POWER LIMITATION TABLE C403.2.12.1(2) FAN POWER LIMITATION PRESSURE DROP ADJUSTMENT |
55 | TABLE C403.2.14(1) MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATION TABLE C403.2.14(2) MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATORS AND FREEZERS |
56 | TABLE C403.2.14(2)—continued MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATORS AND FREEZERS |
58 | TABLE C403.3(1) MINIMUM CHILLED-WATER SYSTEM COOLING CAPACITY FOR DETERMINING ECONOMIZER COOLING REQUIREMENTS |
59 | TABLE C403.3.1 DX COOLING STATESTAGE REQUIREMENTS FOR MODULATING AIRFLOW UNITS |
60 | TABLE C403.3.3.3 HIGH-LIMIT SHUTOFF CONTROL SETTING FOR AIR ECONOMIZERS TABLE C403.4.1.1 EFFECTIVE DATES FOR FAN CONTROL |
62 | TABLE C403.4.2.5 BOILER TURNDOWN TABLE C403.4.2.7 PIPING SYSTEM DESIGN MAXIMUM FLOW RATE IN GPM |
64 | TABLE C403.4.6 MAXIMUM HOT GAS BYPASS CAPACITY |
65 | SECTION C404 SERVICE WATER HEATING (MANDATORY) |
66 | TABLE C404.2 MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT |
68 | TABLE C404.5.1 PIPING VOLUME AND MAXIMUM PIPING LENGTHS SECTION C405 ELECTRICAL POWER AND LIGHTING SYSTEMS |
71 | FIGURE C405.2.3.2(1) DAYLIGHT ZONE ADJACENT TO FENESTRATION IN A WALL FIGURE C405.2.3.2(2) DAYLIGHT ZONE UNDER A ROOFTOP MONITOR |
72 | FIGURE C405.2.3.2(3) DAYLIGHT ZONE UNDER A SLOPED ROOFTOP MONITOR FIGURE C405.2.3.3 DAYLIGHT ZONE UNDER A ROOF FENESTRATION ASSEMBLY |
73 | EQUATION 4-7 |
74 | TABLE C405.4.2(1) INTERIOR LIGHTING POWER ALLOWANCES: BUILDING AREA METHOD EQUATION 4-8 |
75 | TABLE C405.4.2(2) INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD TABLE C405.4.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD |
76 | TABLE C405.4.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD TABLE C405.5.2(1) EXTERIOR LIGHTING ZONES |
77 | TABLE C405.5.2(2) INDIVIDUAL LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS |
78 | TABLE C405.7 MINIMUM NOMINAL EFFICIENCY LEVELS FOR 10 CFR 431 LOW-VOLTAGE DRY-TYPE DISTRIBUTION TRANSFORMERS |
79 | TABLE C405.8(1) MINIMUM NOMINAL FULL-LOAD EFFICIENCY FOR 60 HZ NEMA GENERAL PURPOSE ELECTRIC MOTORS (SUBTYPE I) RATED 600 VOLTS OR LESS (Random Wound)a |
80 | TABLE C405.8(2) MINIMUM NOMINAL FULL-LOAD EFFICIENCY OF GENERAL PURPOSE ELECTRIC MOTORS (SUBTYPE II) AND ALL DESIGN B MOTORS GREATER THAN 200 HORSEPOWERa TABLE C405.8(3) MINIMUM AVERAGE FULL LOAD EFICIENCY POLYPHASE SMALL ELECTRIC MOTORSa |
81 | TABLE C405.8(4) MINIMUM AVERAGE FULL LOAD EFFICIENCY FOR CAPACITOR-START CAPACITOR-RUN AND CAPACITOR-START INDUCTION-RUN SMALL ELECTRIC MOTORSa SECTION C406 ADDITIONAL EFFICIENCY PACKAGE OPTIONS |
82 | SECTION C407 SYSTEM COMMISSIONING |
85 | CHAPTER 5 CE EXISTING BUILDINGS SECTION C501 GENERAL SECTION C502 ADDITIONS |
86 | SECTION C503 ALTERATIONS SECTION C504 REPAIRS |
87 | SECTION C505 CHANGE OF OCCUPANCY OR USE |
89 | CHAPTER 6 REFERENCED STANDARDS AAMA AHAM AHRI |
90 | AMCA ANSI APSP ASHRAE |
91 | ASME ASTM CSA |
92 | CTI DASMA DOE ICC |
93 | IEEE IES ISO NEMA NFPA |
94 | NFRC SMACNA UL US-FTC WDMA |
95 | INDEX |