WA CommericalEnergyCode 2018

$64.35

Washington State Energy Code, Commercial, 1st Printing – Effective July 1, 2020

Published By Publication Date Number of Pages
WA 2018 232
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

None

PDF Catalog

PDF Pages PDF Title
3 TABLE OF CONTENTS
5 Margin Markings
6 2018 WSEC_C Final.docx
CHAPTER 1 – Scope and Administration
Section C101 – Scope and General Requirements
Section C102 – Alternative Materials, Design and Methods of Construction and Equipment
7 Section C103 – Construction Documents
9 Section C104 – Inspections
10 Section C105 – Validity
Section C106 – Referenced Standards
Section C107 – Fees
11 Section C108 – Stop Work Order
Section C109 – Board of Appeals
Section C110 – Violations
Section C111 – Liability
12 CHAPTER 2 – Definitions
24 CHAPTER 3 – General Requirements
Section C301 – Climate Zones
TABLE C301.1: Climate Zones
Section C302 – Design Conditions
Section C303 – Materials, Systems and Equipment
25 TABLE C303.1.3(1): Default Glazed Window, Glass Door and Skylight U-factors
27 TABLE C303.1.5: U-Factors for Spandrel Panels and Glass Curtain Walls
28 TABLE C303.1.3(3): Default Glazed Fenestration SHGC and VT
TABLE C303.1.3(4): Default U-factors for Skylights
29 TABLE C303.1.3(5): Small Business Compliance Table Default U-factors for Vertical Fenestration
30 CHAPTER 4 – Commercial Energy Efficiency
Section C401 – General
Section C402 – Building Envelope Requirements
31 TABLE C402.1.1.3: Non-Opaque Thermal Envelope Maximum Requirements
32 TABLE C402.1.3: Opaque Thermal Envelope Insulation Component Minimum Requirements, R-Value Method
35 TABLE C402.1.4: Opaque Thermal Envelope Assembly Maximum Requirements, U-factor Method
36 TABLE C402.1.4.1: Effective R-Values for Steel Stud Wall Assemblies
40 TABLE C402.4: Building Envelope Fenestration Maximum U-factor and SHGC Requirements
45 Section C403 – Mechanical Systems
Section C403.1 – General
46 Section C403.2 – System Design
47 Section C403.3 – Equipment Selection
48 TABLE C403.3.2(1)A: Electrically Operated Unitary Air Conditioners and Condensing Units
50 TABLE C403.3.2(1)B: Electrically Operated Variable Refrigerant Flow Air Conditioners
TABLE C403.3.2(1)C: Electrically Operated Variable Refrigerant Flow Air-to-Air and Applied Heat Pumps
52 TABLE C403.3.2(2): Electrically Operated Unitary and Applied Heat Pumps
53 TABLE C403.3.2(3): Electrically Operated Packaged Terminal Air Conditioners, Packaged Terminal Heat Pumps, Single-Package Vertical Air Conditioners, Single-Package Vertical Heat Pumps, Room Air Conditioners and Room Air Conditioner Heat Pumps
55 TABLE C403.3.2(4): Warm Air Furnaces and Combination Warm Air Furnaces/Air-Conditioning Units, Warm Air Duct Furnaces and Unit Heaters, Minimum Efficiency Requirements
TABLE C403.3.2(5): Gas- and Oil-Fired Boilers
56 TABLE C403.3.2(7): Water Chilling Packages
57 TABLE C403.3.2(8): Heat Rejection Equipment
58 TABLE C403.3.2(9): Air Conditioners and Condensing Units Serving Computer Rooms and Data Centers
59 TABLE C403.3.2(10): Heat Transfer Equipment
60 TABLE C403.3.2(11): Electrically Operated DX-DOAS Units, Single-Package and Remote Condenser, Without Energy Recovery
TABLE C403.3.2(12): Electrically Operated DX-DOAS Units, Single-Package and Remote Condenser, with Energy Recovery
63 TABLE C403.3.5: Occupancy Classifications Requiring DOAS
64 C403.4 HVAC System Controls
68 TABLE C403.4.4: Variable Speed Drive Requirements for Demand-Controlled Pumps
69 TABLE C403.4.11.1: DDC Applications and Qualifications
70 Section C403.5 – Economizers
71 TABLE C403.5: Equipment Efficiency Performance Exception for Economizers
72 TABLE C403.5.1: DX Cooling Stage Requirements for Modulating Airflow Units
73 TABLE C403.5.3.3: High-Limit Shutoff Control Settings for Air Economizers
74 Section C403.6 – Requirements for Mechanical Systems Serving Multiple Zones
78 Section C403.7 – Ventilation and Exhaust Systems
81 TABLE C403.7.6(1): Energy Recover Requirement for Ventilation Systems Operating Less than 8,000 Hours per Year
TABLE C403.7.6.1(2): Energy Recovery Requirement for Ventilation Systems Operating Not Less Than 8,000 Hours per Year
TABLE C403.7.7.1.2: Maximum Net Exhaust Flow Rate per Linear Foot of Hood
84 Section C403.8 – Fan and Fan Controls
TABLE C403.8.1(1): Fan Power Limitation
85 TABLE C403.8.1(2): Fan Power Limitation Pressure Drop Adjustment
86 TABLE C403.8.4: Group R Exhaust Fan Efficacy
87 TABLE C403.8.5.1: Fan Control
Section C403.9 – Heat Rejection and Heat Recovery equipment
89 Section C403.10 – Construction of HVAC System Elements
TABLE C403.10.1.1: Outdoor Air Ductwork Insulation
90 TABLE C403.10.1.2: Supply, Return, Exhaust and Relief Air Ductwork Insulation
92 TABLE C403.10.3: Minimum Pipe Insulation Thickness
Section C403.11 – Mechanical Systems Located Outside of the Building Thermal Envelope
Section C403.12 High Efficiency Single-Zone VAV Systems
94 Section C403.13 – Commissioning
Section C404 – Service Water Heating and Pressure-Booster Systems
TABLE C404.2: Minimum Performance of Water-Heating Equipment
97 TABLE C404.3.1: Piping Volume and Maximum Piping Lengths
100 Section C405 – Electrical Power and Lighting Systems
Section C405.1 – General
101 Section C405.2 Lighting Controls
106 FIGURE C405.2.4.2(1): Sidelit Zone Adjacent to Fenestration in a Wall
FIGURE C405.2.4.2(2): Sidelit Zone Adjacent to Clerestory Fenestration in a Wall
107 FIGURE C405.2.4.3(1): Toplit Zone Under a Rooftop Fenestration Assembly
108 FIGURE C405.2.4.3(2): Toplit Zone Under a Rooftop Monitor
FIGURE C405.2.4.3(3): Toplit Zone Under a Sloped Rooftop Monitor
FIGURE C405.2.4.3(4): Toplit Zone Under Atrium Fenestration
110 Section C405.4 – Interior Lighting Power Requirements
112 TABLE C405.4.2(1): Interior Lighting Power Allowance: Building Area Method
113 TABLE C405.4.2(2): Interior Lighting Power Allowances: Space-by-Space Method
115 Section C405.5 – Exterior Lighting Power Requirements
116 TABLE C405.5.3(1): Exterior Lighting Zones
117 TABLE C405.5.3(2): Lighting Power Allowances for Building Exteriors
118 TABLE C405.5.3(3): Individual Lighting Power Allowances for Building Exteriors
Section C405.6 – Electrical Transformers
119 TABLE C405.6: Minimum Nominal Efficiency Levels for Low Voltage Dry-Type Distribution Transformers
Section C405.7 – Dwelling Unit Electrical Energy Consumption
Section C405.8 – Electric Motor Efficiency
120 TABLE C405.8(1): Minimum Full-Load Efficiency For NEMA Design A, NEMA Design B and IEC Design N Motors
121 TABLE C405.8(2): Minimum Nominal Full-Load Efficiency for NEMA Design C and IEC Design H Motors
122 TABLE C405.8(3): Minimum Average Full-Load Efficiency for Polyphase Small Electric Motors
TABLE C405.8(4): Minimum Average Full-Load Efficiency for Capacitor-Start Capacitor-Run and Capacitor-Start Induction-Run Small Electric Motors
Section C405.9 – Vertical and Horizontal Transportation Systems and Equipment
123 Section C405.10 – Controlled Receptacles
Section C405.11 – Voltage Drop in Feeders and Branch Circuits
Section C405.12 – Commissioning
Section C406 – Efficiency Packages
124 TABLE C406.1: Efficiency Package Credits
126 TABLE C406.5: On-Site Renewable Energy System Rating
128 Section C407 – Total Building Performance
129 TABLE C407.2: Mandatory Compliance Measures for Total Building Performance Method
130 TABLE C407.3(1): Carbon Emissions Factors
TABLE C407.3(2): Building Performance Factors
Section C408 – System Commissioning
133 FIGURE C408.1.4.1: Commissioning Compliance Checklist
135 Section C409 – Energy Metering and Energy Consumption Management
138 Section C410 – Refrigeration System Requirements
TABLE C410.1.1(1): Minimum Efficiency Requirements: Commercial Refrigeration
139 TABLE C410.1.1(2): Minimum Efficiency Requirements: Commercial Refrigerators and Freezers
141 TABLE C410.2.1.1(1): Walk-in Cooler and Freezer Display Doors Efficiency Requirements
TABLE C410.2.1.1(2): Walk-in Cooler and Freezer Non-Display Doors Efficiency Requirements
142 TABLE C410.2.1.1(3): Walk-in Cooler and Freezer Refrigeration System Efficiency Requirements
143 Section C411 – Solar Readiness
146 CHAPTER 5 – Existing Buildings
Section C501 – General
147 Section C502 – Additions
148 Section C503 – Alterations
151 TABLE C503.4: Economizer Compliance Options for Mechanical Alterations
154 Section C504 – Repairs
Section C505 – Change of Occupancy or Use
156 CHAPTER 6 – Referenced Standards
162 2018 Com Energy Appendices
163 Appendix A: Default Heat Loss Coefficients
198 Appendix B: Default Internal Load Values and Schedules
210 Appendix C: Exterior Design Conditions
212 Appendix D: Calculation of HVAC Total System Performance Ratio
222 Appendix E: Renewable Energy
224 Appendix F: Outcome-Based Energy Budget
WA CommericalEnergyCode 2018
$64.35