WA MechanicalCode 2018 1stptg
$55.79
Washington State Mechanical Code
Published By | Publication Date | Number of Pages |
WA | 2018 | 183 |
This is a fully integrated code based on the 2018 International Mechanical Code®
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | 2018 WASHINGTON STATE MECHANICAL CODE BASED ON THE 2018 INTERNATIONAL MECHANICAL CODE® |
2 | 2018 WASHINGTON STATE MECHANICAL CODE BASED ON THE 2018 INTERNATIONAL MECHANICAL CODE® TITLE PAGE |
3 | COPYRIGHT |
4 | PREFACE |
12 | EFFECTIVE USE OF THE INTERNATIONAL MECHANICAL CODE |
16 | TABLE OF CONTENTS |
20 | CHAPTER 1 SCOPE AND ADMINISTRATION PART 1–SCOPE AND APPLICATION SECTION 101 GENERAL SECTION 102 APPLICABILITY |
21 | PART 2–ADMINISTRATION AND ENFORCEMENT SECTION 103 DEPARTMENT OF MECHANICAL INSPECTION SECTION 104 DUTIES AND POWERS OF THE CODE OFFICIAL |
22 | SECTION 105 APPROVAL SECTION 106 PERMITS |
24 | SECTION 107 INSPECTIONS AND TESTING |
26 | SECTION 108 VIOLATIONS |
27 | SECTION 109 MEANS OF APPEAL SECTION 110 TEMPORARY EQUIPMENT, SYSTEMS AND USES |
30 | CHAPTER 2 DEFINITIONS SECTION 201 GENERAL SECTION 202 GENERAL DEFINITIONS |
42 | CHAPTER 3 GENERAL REGULATIONS SECTION 301 GENERAL |
43 | SECTION 302 PROTECTION OF STRUCTURE |
44 | SECTION 303 EQUIPMENT AND APPLIANCE LOCATION SECTION 304 INSTALLATION |
46 | SECTION 305 PIPING SUPPORT TABLE 305.4 PIPING SUPPORT SPACINGa SECTION 306 ACCESS AND SERVICE SPACE |
48 | SECTION 307 CONDENSATE DISPOSAL TABLE 307.2.2 CONDENSATE DRAIN SIZING |
49 | SECTION 308 CLEARANCE REDUCTION |
50 | TABLE 308.4.2 CLEARANCE REDUCTION METHODSb SECTION 309 TEMPERATURE CONTROL SECTION 310 EXPLOSION CONTROL |
51 | SECTION 311 SMOKE AND HEAT VENTS SECTION 312 HEATING AND COOLING LOAD CALCULATIONS |
52 | CHAPTER 4 VENTILATION SECTION 401 GENERAL |
53 | TABLE 401.5 OPENING SIZES IN LOUVERS, GRILLES AND SCREENS PROTECTING AIR INTAKE OPENINGS SECTION 402 NATURAL VENTILATION SECTION 403 MECHANICAL VENTILATION |
54 | EQUATION 4-1 TABLE 403.3.1.1.1.2 ZONE AIR DISTRIBUTION EFFECTIVENESS |
55 | EQUATION 4-2 EQUATION 4-3 EQUATION 4-4 EQUATION 4-5 EQUATION 4-6 TABLE 403.3.1.1.2.3.2 SYSTEM VENTILATION EFFICIENCY EQUATION 4-6A EQUATION 4-6B |
56 | EQUATION 4-7 EQUATION 4-8 EQUATION 4-10 EQUATION 4-11 |
57 | TABLE 403.4.2 WHOLE-HOUSE MECHANICAL VENTILATION AIRFLOW RATE (CONTINUOUSLY OPERATING SYSTEMS) TABLE 403.4.3 SYSTEM COEFFICIENT (Csystem) |
58 | TABLE 403.4.6.5 INTERMITTENT WHOLE-HOUSE MECHANICAL VENTILATION RATE FACTORS |
59 | TABLE 403.4.7 MINIMUM EXHAUST RATES TABLE 403.4.7.2 PRESCRIPTIVE EXHAUST DUCT SIZING |
60 | SECTION 404 ENCLOSED PARKING GARAGES SECTION 405 SYSTEMS CONTROL SECTION 406 VENTILATION OF UNINHABITED SPACES SECTION 407 AMBULATORY CARE FACILITIES AND GROUP I-2 OCCUPANCIES |
61 | TABLE 403.3.1.1 REQUIRED OUTDOOR VENTILATION AIR |
62 | TABLE 403.3.1.1—continued REQUIRED OUTDOOR VENTILATION AIR |
64 | CHAPTER 5 EXHAUST SYSTEMS SECTION 501 GENERAL |
65 | SECTION 502 REQUIRED SYSTEMS |
66 | EQUATION 5-1 |
72 | SECTION 503 MOTORS AND FANS SECTION 504 CLOTHES DRYER EXHAUST |
73 | TABLE 504.8.4.1 DRYER EXHAUST DUCT FITTING EQUIVALENT LENGTH |
74 | SECTION 505 DOMESTIC COOKING EXHAUST EQUIPMENT |
75 | SECTION 506 COMMERCIAL KITCHEN HOOD VENTILATION SYSTEM DUCTS AND EXHAUST EQUIPMENT |
80 | SECTION 507 COMMERCIAL KITCHEN HOODS |
81 | TABLE 507.1.2 TYPE OF HOOD REQUIRED FOR DOMESTIC COOKING APPLIANCES IN THE FOLLOWING SPACESa |
82 | TABLE 507.2.8 MINIMUM DISTANCE BETWEEN THE LOWEST EDGE OF A GREASE FILTER AND THE COOKING SURFACE OR THE HEATING SURFACE |
83 | SECTION 508 COMMERCIAL KITCHEN MAKEUP AIR |
84 | SECTION 509 FIRE SUPPRESSION SYSTEMS SECTION 510 HAZARDOUS EXHAUST SYSTEMS |
86 | TABLE 510.9.2 CLEARANCE TO COMBUSTIBLES TABLE 510.9 MINIMUM DUCT THICKNESS SECTION 511 DUST, STOCK AND REFUSE CONVEYING SYSTEMS |
87 | TABLE 511.2 CONSTRUCTION, CLEARANCE AND TERMINATION REQUIREMENTS FOR SINGLE-WALL METAL CHIMNEYS SECTION 512 SUBSLAB SOIL EXHAUST SYSTEMS SECTION 513 SMOKE CONTROL SYSTEMS |
89 | EQUATION 5-2 |
90 | EQUATION 5-3 |
91 | SECTION 514 ENERGY RECOVERY VENTILATION SYSTEMS |
92 | SECTION 515 WASTE OR LINEN CHUTE VENTING |
94 | CHAPTER 6 DUCT SYSTEMS SECTION 601 GENERAL |
95 | SECTION 602 PLENUMS |
97 | SECTION 603 DUCT CONSTRUCTION AND INSTALLATION |
98 | TABLE 603.4 DUCT CONSTRUCTION MINIMUM SHEET METAL THICKNESS FOR SINGLE DWELLING UNITSa |
99 | SECTION 604 INSULATION |
100 | SECTION 605 AIR FILTERS SECTION 606 SMOKE DETECTION SYSTEMS CONTROL |
102 | SECTION 607 DUCT AND TRANSFER OPENINGS [BF] TABLE 607.3.2.1 FIRE DAMPER RATING |
108 | CHAPTER 7 COMBUSTION AIR SECTION 701 GENERAL |
110 | CHAPTER 8 CHIMNEYS AND VENTS SECTION 801 GENERAL |
111 | SECTION 802 VENTS TABLE 802.2 VENT APPLICATION |
112 | SECTION 803 CONNECTORS TABLE 803.9(1) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR LOW-HEAT APPLIANCES TABLE 803.9(2) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR MEDIUM- AND HIGH-HEAT APPLIANCES |
113 | TABLE 803.10.4 CHIMNEY CONNECTOR SYSTEMS AND CLEARANCES TO COMBUSTIBLE WALL MATERIALS FOR DOMESTIC HEATING APPLIANCES TABLE 803.10.6 CONNECTOR CLEARANCES TO COMBUSTIBLES SECTION 804 DIRECT-VENT, INTEGRAL VENT AND MECHANICAL DRAFT SYSTEMS |
114 | SECTION 805 FACTORY-BUILT CHIMNEYS |
115 | SECTION 806 METAL CHIMNEYS |
116 | CHAPTER 9 SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT SECTION 901 GENERAL SECTION 902 MASONRY FIREPLACES SECTION 903 FACTORY-BUILT FIREPLACES SECTION 904 PELLET FUEL-BURNING APPLIANCES SECTION 905 FIREPLACE STOVES AND ROOM HEATERS SECTION 906 FACTORY-BUILT BARBECUE APPLIANCES |
117 | SECTION 907 INCINERATORS AND CREMATORIES SECTION 908 COOLING TOWERS, EVAPORATIVE CONDENSERS AND FLUID COOLERS SECTION 909 VENTED WALL FURNACES SECTION 910 FLOOR FURNACES |
118 | SECTION 911 DUCT FURNACES SECTION 912 INFRARED RADIANT HEATERS SECTION 913 CLOTHES DRYERS SECTION 914 SAUNA HEATERS SECTION 915 ENGINE AND GAS TURBINE-POWERED EQUIPMENT AND APPLIANCES SECTION 916 POOL AND SPA HEATERS |
119 | SECTION 917 COOKING APPLIANCES SECTION 918 FORCED-AIR WARM-AIR FURNACES SECTION 919 CONVERSION BURNERS SECTION 920 UNIT HEATERS SECTION 921 VENTED ROOM HEATERS SECTION 922 KEROSENE AND OIL-FIRED STOVES SECTION 923 SMALL CERAMIC KILNS SECTION 924 STATIONARY FUEL CELL POWER SYSTEMS SECTION 925 MASONRY HEATERS |
120 | SECTION 926 GASEOUS HYDROGEN SYSTEMS SECTION 927 RADIANT HEATING SYSTEMS SECTION 928 EVAPORATIVE COOLING EQUIPMENT SECTION 929 HIGH-VOLUME LARGE-DIAMETER FANS |
122 | CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS SECTION 1001 GENERAL SECTION 1002 WATER HEATERS SECTION 1003 PRESSURE VESSELS |
123 | SECTION 1004 BOILERS TABLE 1004.3.1 BOILER TOP CLEARANCES SECTION 1005 BOILER CONNECTIONS SECTION 1006 SAFETY AND PRESSURE RELIEF VALVES AND CONTROLS |
124 | SECTION 1007 BOILER LOW-WATER CUTOFF SECTION 1008 BOTTOM BLOWOFF VALVE SECTION 1009 HOT WATER BOILER EXPANSION TANK |
125 | EQUATION 10-1 TABLE 1009.2 CLOSED-TYPE EXPANSION TANK SIZING SECTION 1010 GAUGES SECTION 1011 TESTS |
126 | CHAPTER 11 REFRIGERATION SECTION 1101 GENERAL SECTION 1102 SYSTEM REQUIREMENTS |
127 | SECTION 1103 REFRIGERATION SYSTEM CLASSIFICATION |
128 | TABLE 1103.1 REFRIGERANT CLASSIFICATION, AMOUNT AND OEL |
129 | TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL |
130 | TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL |
131 | TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL |
132 | TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL |
133 | SECTION 1104 SYSTEM APPLICATION REQUIREMENTS |
134 | TABLE 1104.3.2 MAXIMUM PERMISSIBLE QUANTITIES OF REFRIGERANTS SECTION 1105 MACHINERY ROOM, GENERAL REQUIREMENTS EQUATION 11-1 |
135 | EQUATION 11-2 SECTION 1106 MACHINERY ROOM, SPECIAL REQUIREMENTS |
136 | TABLE 1106.5.2 MINIMUM EXHAUST RATES SECTION 1107 REFRIGERANT PIPING |
137 | SECTION 1108 FIELD TEST |
138 | [F] SECTION 1109 PERIODIC TESTING |
140 | CHAPTER 12 HYDRONIC PIPING SECTION 1201 GENERAL SECTION 1202 MATERIAL TABLE 1202.4 HYDRONIC PIPE |
141 | TABLE 1202.5 HYDRONIC PIPE FITTINGS SECTION 1203 JOINTS AND CONNECTIONS |
143 | SECTION 1204 PIPE INSULATION SECTION 1205 VALVES SECTION 1206 PIPING INSTALLATION |
144 | SECTION 1207 TRANSFER FLUID SECTION 1208 TESTS SECTION 1209 EMBEDDED PIPING SECTION 1210 PLASTIC PIPE GROUND-SOURCE HEAT PUMP LOOP SYSTEMS |
145 | TABLE 1210.4 GROUND-SOURCE LOOP PIPE TABLE 1210.5 GROUND-SOURCE LOOP PIPE FITTINGS |
148 | CHAPTER 13 FUEL OIL PIPING AND STORAGE SECTION 1301 GENERAL SECTION 1302 MATERIAL TABLE 1302.3 FUEL OIL PIPING SECTION 1303 JOINTS AND CONNECTIONS |
149 | SECTION 1304 PIPING SUPPORT SECTION 1305 FUEL OIL SYSTEM INSTALLATION |
150 | SECTION 1306 OIL GAUGING SECTION 1307 FUEL OIL VALVES SECTION 1308 TESTING |
152 | CHAPTER 14 SOLAR THERMAL SYSTEMS SECTION 1401 GENERAL SECTION 1402 DESIGN AND INSTALLATION |
154 | SECTION 1403 HEAT TRANSFER FLUIDS SECTION 1404 LABELING |
156 | CHAPTER 15 REFERENCED STANDARDS ACCA AHRI AMCA ANSI |
157 | ASHRAE ASME |
158 | ASSE ASSE ASTM |
161 | AWS |
162 | AWWA CPSC CSA |
163 | DOL FDA FS HVI ICC |
164 | IIAR MSS NAIMA NBBI |
165 | NFPA NSF |
166 | SMACNA UL |
170 | APPENDIX A CHIMNEY CONNECTOR PASS-THROUGHS FIGURE A-1 CHIMNEY CONNECTOR SYSTEMS |
171 | FIGURE A-1—continued CHIMNEY CONNECTOR SYSTEMS |
172 | APPENDIX B RECOMMENDED PERMIT FEE SCHEDULE B101 MECHANICAL WORK, OTHER THAN GAS PIPING SYSTEMS B102 FEE FOR REINSPECTION B103 TEMPORARY OPERATION INSPECTION FEE B104 SELF-CONTAINED UNITS LESS THAN 2 TONS |
174 | INDEX |
180 | PROCTORED REMOTE ONLINE TESTING OPTION (PRONTO) |
181 | ICC EVALUATION SERVICE |
182 | ICC’S DIGITAL CODES LIBRARY |
183 | ICC LEARNING CENTER |