Shopping Cart

No products in the cart.

WA SeattleEnergyCode 2012

$28.17

Seattle Energy Code

Published By Publication Date Number of Pages
WA 2012 224
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

A fully integrated custom code based on the 2012 International Energy Conservation Code® (IECC®) and the 2012 Washington State Energy Code.

PDF Catalog

PDF Pages PDF Title
1 2012 SEATTLE ENERGY CODE 2012 WASHINGTON STATE ENERGY CODE AS AMENDED BY THE CITY OF SEATTLE
2 COPYRIGHT
3 PREFACE
6 WASHINGTON STATE PREFACE
9 EFFECTIVE USE OF THE INTERNATIONAL ENERGY CONSERVATION CODE
11 LEGISLATION
13 TABLE OF CONTENTS
15 IECC—COMMERCIAL PROVISIONS
TABLE OF CONTENTS
17 CHAPTER 1 [CE] SCOPE AND ADMINISTRATION
SECTION C101 SCOPE AND GENERAL REQUIREMENTS
18 TABLE C101.4.3.1 ECONOMIZER COMPLIANCE OPTIONS FOR MECHANICAL ALTERATIONS
19 TABLE C101.4.3.1—continued ECONOMIZER COMPLIANCE OPTIONS FOR MECHANICAL ALTERATIONS
22 SECTION C102 ALTERNATE MATERIALS—METHOD OF CONSTRUCTION, DESIGN OR INSULATING SYSTEMS
SECTION C103 APPLICATIONS AND PERMITS ((CONSTRUCTION DOCUMENTS))
23 SECTION C104 INSPECTIONS
24 SECTION C105 VALIDITY
SECTION C106 REFERENCED STANDARDS
SECTION C107 FEES
SECTION C108 ((STOP WORK ORDER)) ENFORCEMENT
25 SECTION C109 ((BOARD OF APPEALS)) ADMINISTRATIVE REVIEW
SECTION C110 VIOLATIONS
SECTION C111 LIABILITY
27 CHAPTER 2 [CE] DEFINITIONS
SECTION C201 GENERAL
SECTION C202 GENERAL DEFINITIONS
29 FIGURE C202.1 DAYLIGHT ZONE
35 CHAPTER 3 [CE] GENERAL REQUIREMENTS
SECTION C301 CLIMATE ZONES
TABLE C301.1 CLIMATE ZONES, MOISTURE REGIMES, AND WARM HUMID DESIGNATIONS BY STATE AND COUNTY
SECTION C302 DESIGN CONDITIONS
SECTION C303 MATERIALS, SYSTEMS AND EQUIPMENT
36 TABLE C303.1.3(1) DEFAULT GLAZED FENESTRATION U-FACTOR
TABLE C303.1.3(2) DEFAULT DOOR U-FACTORS
TABLE C303.1.3(3) DEFAULT GLAZED FENESTRATION SHGC AND VT
37 TABLE C303.1.3(4) DEFAULT U-FACTORS FOR SKYLIGHTSa, b, c, d
38 TABLE C303.1.3(5) SMALL BUSINESS COMPLIANCE TABLE DEFAULT U-FACTORS FOR VERTICAL FENESTRATION
39 CHAPTER 4 [CE] COMMERCIAL ENERGY EFFICIENCY
SECTION C401 GENERAL
SECTION C402 BUILDING ENVELOPE REQUIREMENTS
40 TABLE C402.1.2 OPAQUE THERMAL ENVELOPE ASSEMBLY REQUIREMENTSa
42 TABLE C402.1.5.4 EXAMPLE OF SENSITIVITY ANALYSIS REPORT FORMAT
43 TABLE C402.1.5.12 FINANCIAL SECURITY AND ENERGY EFFICIENCY REIMBURSEMENTS
44 EQUATION C402-1 TARGET UAt
45 EQUATION C402-1—continued TARGET UAT
46 EQUATION C402-2 PROPOSED UAP
47 EQUATION C402-3 TARGET SHGCAt
EQUATION C402-4 PROPOSED SHGCAP
TABLE C402.2 OPAQUE THERMAL ENVELOPE REQUIREMENTSa, f
48 TABLE C402.2 OPAQUE THERMAL ENVELOPE REQUIREMENTSa, f—continued
49 TABLE C402.2.1.1 MINIMUM ROOF REFLECTANCE AND EMITTANCE OPTIONSa
50 TABLE C402.3 BUILDING ENVELOPE REQUIREMENTS—FENESTRATION
51 EQUATION C4-1
52 EQUATION C4-2
TABLE C402.3.3.1 SHGC ADJUSTMENT MULTIPLIERS
54 TABLE C402.4.3 MAXIMUM AIR INFILTRATION RATE FOR FENESTRATION ASSEMBLIES
55 EQUATION C402-5 COMPONENT PERFORMANCE UxA
56 SECTION C403 MECHANICAL SYSTEMS
57 EQUATION C4-3
EQUATION C4-4
59 TABLE C403.2.3(1) A MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS
60 TABLE C403.2.3(1) A—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS
61 TABLE C403.2.3(1) BMINIMUM EFFICIENCY REQUIREMENTS: AIR CONDITIONERS AND CONDENSING UNITS SERVING COMPUTER ROOMS
62 TABLE C403.2.3(1)C MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED VARIABLE REFRIGERANT FLOW AIR CONDITIONERS
TABLE C403.2.3(1)D MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED VARIABLE REFRIGERANT FLOW AIR-TO-AIR AND APPLIED HEAT PUMPS
63 TABLE C403.2.3(1)D—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED VARIABLE REFRIGERANT FLOW AIR-TO-AIR AND APPLIED HEAT PUMPS
64 TABLE C403.2.3(2) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS
65 TABLE C403.2.3(2)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS
66 TABLE C403.2.3(3) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE-PACKAGE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS
67 TABLE C403.2.3(3)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS
68 TABLE 403.2.3(4) WARM AIR FURNACES AND COMBINATION WARM AIR FURNACES/AIR-CONDITIONING UNITS, WARM AIR DUCT FURNACES AND UNIT HEATERS, MINIMUM EFFICIENCY REQUIREMENTS
69 TABLE C403.2.3(5) MINIMUM EFFICIENCY REQUIREMENTS: GAS- AND OIL-FIRED BOILERS
TABLE C403.2.3(6) RESERVED
70 TABLE C403.2.3(7) MINIMUM EFFICIENCY REQUIREMENTS: WATER CHILLING PACKAGESa
71 TABLE C403.2.3(8) MINIMUM EFFICIENCY REQUIREMENTS: HEAT REJECTION EQUIPMENT
TABLE C403.2.3(9) HEAT TRANSFER EQUIPMENT
75 TABLE C403.2.6 ENERGY RECOVERY REQUIREMENT
76 EQUATION C4-5
77 TABLE C403.2.8 MINIMUM PIPE INSULATION THICKNESS (thickness in inches)a, c
TABLE C403.2.10.1(1) FAN POWER LIMITATION
78 TABLE C403.2.10.1(2) FAN POWER LIMITATION PRESSURE DROP ADJUSTMENT
81 TABLE C403.3.1(1) RESERVED
TABLE C403.3.1(2) EQUIPMENT EFFICIENCY PERFORMANCE EXCEPTION FOR ECONOMIZERS
82 TABLE C403.3.1.1.3(1) HIGH-LIMIT SHUTOFF CONTROL OPTIONS FOR AIR ECONOMIZERS
TABLE C403.3.1.1.3(2) HIGH-LIMIT SHUTOFF CONTROL SETTING FOR AIR ECONOMIZERS
84 C403.4.1 EXCEPTION 5 TABLE
87 TABLE C403.4.7 MAXIMUM HOT GAS BYPASS CAPACITY
88 TABLE C403.4.8 PIPING SYSTEM DESIGN MAXIMUM FLOW RATE IN GPM1
89 SECTION C404 SERVICE WATER HEATING (MANDATORY)
90 TABLE C404.2 MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT
91 SECTION C405 ELECTRICAL POWER AND LIGHTING SYSTEMS
95 TABLE C405.5.2(1) INTERIOR LIGHTING POWER ALLOWANCES: BUILDING AREA METHOD
TABLE C405.5.2(2) INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
96 TABLE C405.5.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
TABLE C405.5.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
97 TABLE C405.6.2(1) EXTERIOR LIGHTING ZONES
98 TABLE C405.6.2(2) INDIVIDUAL LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS
99 SECTION C406 ADDITIONAL EFFICIENCY PACKAGE OPTIONS
SECTION C407 TOTAL BUILDING PERFORMANCE
100 TABLE C407.5.1(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
101 TABLE C407.5.1(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
102 TABLE C407.5.1(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
103 TABLE C407.5.1(2) HVAC SYSTEMS MAP
104 TABLE C407.5.1(3) SPECIFICATIONS FOR THE STANDARD REFERENCE DESIGN HVAC SYSTEM DESCRIPTIONS
105 TABLE C407.5.1(4) NUMBER OF CHILLERS
TABLE C407.5.1(5) WATER CHILLER TYPES
106 SECTION C408 SYSTEM COMMISSIONING
108 FIGURE C408.1.2.1 COMMISSIONING COMPLIANCE CHECKLIST
109 FIGURE C408.1.2.1—continued COMMISSIONING COMPLIANCE CHECKLIST
111 SECTION C409 ENERGY METERING ANDENERGY CONSUMPTION MANAGEMENT
113 SECTION C410 RENEWABLE ENERGY AND SOLAR READINESS
117 CHAPTER 5 [CE] REFERENCED STANDARDS
AAMA
AHAM
AHRI
118 AMCA
ANSI
ASHRAE
ASME
119 ASTM
CSA
CTI
DASMA
120 DOE
IAPMO
ICC
IESNA
121 ISO
NEMA
NFRC
SMACNA
UL
122 US-FTC
WDMA
123 INDEX [CE]
131 IECC—RESIDENTIAL PROVISIONS
TABLE OF CONTENTS
133 CHAPTER 1 [RE] SCOPE AND ADMINISTRATION
PART 1—SCOPE AND APPLICATION
SECTION R101 SCOPE AND GENERAL REQUIREMENTS
134 SECTION R102 ALTERNATE MATERIALS—METHOD OF CONSTRUCTION, DESIGN OR INSULATING SYSTEMS
PART 2—ADMINISTRATION AND ENFORCEMENT
SECTION R103 APPLICATIONS AND PERMITS ((CONSTRUCTION DOCUMENTS))
135 SECTION R104 INSPECTIONS
136 SECTION R105 VALIDITY
SECTION R106 REFERENCED STANDARDS
SECTION R107 FEES
SECTION R108 ENFORCEMENT ((STOP WORK ORDER))
137 SECTION R109 ((BOARD OF APPEALS)) ADMINISTRATIVE REVIEW
SECTION R110 VIOLATIONS
SECTION R111 LIABILITY
139 CHAPTER 2 [RE] DEFINITIONS
SECTION R201 GENERAL
SECTION R202 GENERAL DEFINITIONS
143 CHAPTER 3 [RE] GENERAL REQUIREMENTS
SECTION R301 CLIMATE ZONES
TABLE R301.1 CLIMATE ZONES, MOISTURE REGIMES, AND WARM HUMID DESIGNATIONS BY STATE AND COUNTY
SECTION R302 DESIGN CONDITIONS
SECTION R303 MATERIALS, SYSTEMS AND EQUIPMENT
144 TABLE R303.1.3(1) DEFAULT GLAZED FENESTRATION U-FACTOR
TABLE R303.1.3(2) DEFAULT DOOR U-FACTORS
145 TABLE R303.1.3(3) DEFAULT GLAZED FENESTRATION SHGC AND VT
TABLE R303.1.3(4) DEFAULT U-FACTORS FOR SKYLIGHTSa, b, c, d
146 TABLE R303.1.3(5) SMALL BUSINESS COMPLIANCE TABLE DEFAULT U-FACTORS FOR VERTICAL FENESTRATION
147 CHAPTER 4 [RE] RESIDENTIAL ENERGY EFFICIENCY
SECTION R401 GENERAL
SECTION R402 BUILDING THERMAL ENVELOPE
TABLE R402.1.1 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa
148 TABLE R402.1.3 EQUIVALENT U-FACTORSa
150 TABLE R402.4.1.1 AIR BARRIER AND INSULATION INSTALLATION
151 TABLE R402.4.1.1—continued AIR BARRIER AND INSULATION INSTALLATION
SECTION R403 SYSTEMS
152 TABLE R403.5.1 MECHANICAL VENTILATION SYSTEM FAN EFFICACY
153 SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS (MANDATORY)
SECTION R405 SIMULATED PERFORMANCE ALTERNATIVE (PERFORMANCE)
154 SECTION R406 ADDITIONAL ENERGY EFFICIENCY REQUIREMENTS
155 TABLE R405.5.2(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
156 TABLE R405.5.2(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
157 TABLE R405.5.2(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
TABLE R405.5.2(2) DEFAULT DISTRIBUTION SYSTEM EFFICIENCIES FOR PROPOSED DESIGNSa
158 TABLE R406.2 ENERGY CREDITS (DEBITS)
159 TABLE R406.2—continued ENERGY CREDITS (DEBITS)
160 TABLE R406.2—continued ENERGY CREDITS (DEBITS)
161 CHAPTER 5 [RE] REFERENCED STANDARDS
AAMA
ACCA
ASHRAE
ASME
162 ASTM
CSA
ICC
NEEA
NFRC
163 US-FTC
WDMA
WSU
165 INDEX [RE]
171 CHAPTER 51-11C WAC WASHINGTON STATE ENERGY CODE, APPENDIX CHAPTERS
TABLE OF CONTENTS
173 APPENDIX A DEFAULT HEAT LOSS COEFFICIENTS
SECTION A101 GENERAL REQUIREMENTS
TABLE A101.4 R-VALUE OF FIBERGLASS BATTS COMPRESSED WITHIN VARIOUS DEPTH CAVITIES Insulation R-Values at Standard Thickness
174 TABLE A101.5 DEFAULT R-VALUES FOR BUILDING MATERIALS
175 SECTION A102 CEILINGS
176 TABLE A102.1 DEFAULT U-FACTORS FOR CEILINGS
TABLE A102.2.4(1) STEEL TRUSSa FRAMED CEILING UO
177 TABLE A102.2.4(2) STEEL TRUSSa FRAMED CEILING UO WITH R-3 SHEATHINGb
TABLE A102.2.4(3) STEEL TRUSSa FRAMED CEILING UO WITH R-5 SHEATHINGb
TABLE A102.2.4(4) STEEL TRUSSa FRAMED CEILING UO WITH R-10 SHEATHINGb
TABLE A102.2.4(5) STEEL TRUSSa FRAMED CEILING UO WITH R-15 SHEATHINGb
178 TABLE A102.2.5 DEFAULT U-FACTORS FOR METAL BUILDING ROOFS
179 SECTION A103 ABOVE-GRADE WALLS
180 TABLE A102.2.6 ASSEMBLY U-FACTORS FOR ROOFS WITH INSULATION ENTIRELY ABOVE DECK (UNINTERRUPTED BY FRAMING)
181 TABLE A103.3.1(1) 2 × 4 SINGLE WOOD STUD: R-11 BATT
TABLE A103.3.1(2) 2 × 4 SINGLE WOOD STUD: R-13 BATT
182 TABLE A103.3.1(3) 2 × 4 SINGLE WOOD STUD: R-15 BATT
TABLE A103.3.1(4) 2 × 6 SINGLE WOOD STUD: R-19 BATT
183 TABLE A103.3.1(5) 2 × 6 SINGLE WOOD STUD: R-21 BATT
TABLE A103.3.1(6) 2 × 6 SINGLE WOOD STUD: R-22 BATT
184 TABLE A103.3.1(7) 2 × 6 SINGLE WOOD STUD: TWO R-11 BATTS
TABLE A103.3.1(8) 2 × 8 SINGLE STUD: R-25 BATT
185 TABLE A103.3.2 2 × 6: STRAP WALL
TABLE A103.3.3(1) 2 × 6 + 2 × 4: DOUBLE WOOD STUD
TABLE A103.3.3(2) 2 × 4 + 2 × 4: DOUBLE WOOD STUD
TABLE A103.3.4 LOG WALLS
TABLE A103.3.5 STRESS SKIN PANEL
186 TABLE A103.3.6.1(1) OVERALL ASSEMBLY U-FACTORS FOR METAL STUD WALLS WITH CONTINUOUS INSULATION
187 TABLE A103.3.6.1(2) OVERALL ASSEMBLY U-FACTORS FOR METAL STUD WALLS WITH INSULATION SUPPORTED BY Z-FURRING
188 TABLE A103.3.6.2 EFFECTIVE R-VALUES FOR METAL FRAMING AND CAVITY ONLY
TABLE A103.3.6.3 DEFAULT METAL BUILDING WALL U-FACTORS
189 TABLE A103.3.7.1(1) DEFAULT U-FACTORS FOR CONCRETE MASONRY (CMU) WALLS
190 TABLE A103.3.7.1(2) (((1))) DEFAULT U-FACTORS FOR CONCRETE ((AND MASONRY)) WALLS
191 TABLE A103.3.7.1(2) (((1)))—continued DEFAULT U-FACTORS FOR CONCRETE AND MASONRY WALLSa, b, c, d, e
192 TABLE A103.3.7.1(((2)) 3 DEFAULT U-FACTORS FOR CONCRETE AND MASONRY WALLSa, b, c, d
193 TABLE A103.3.7.1(((2)) 3—continued DEFAULT U-FACTORS FOR CONCRETE AND MASONRY WALLSa, b, c, d
194 TABLE A103.3.7.1(((2)) 3—continued DEFAULT U-FACTORS FOR CONCRETE AND MASONRY WALLSa, b, c, d
195 TABLE A103.3.7.1(((2)) 3—continued DEFAULT U-FACTORS FOR CONCRETE AND MASONRY WALLSa, b, c, d
TABLE A103.3.7.2 DEFAULT U-FACTORS FOR PERIPHERAL EDGES OF INTERMEDIATE CONCRETE FLOORSa, b, c
196 SECTION A104 BELOW-GRADE WALLS AND SLABS
TABLE A104.1 DEFAULT WALL U-FACTORS AND SLAB F-FACTORS FOR BASEMENTS
197 SECTION A105 FLOORS OVER UNCONDITIONED SPACE
TABLE A105.1(1) DEFAULT U-FACTORS FOR FLOORS OVER VENTED CRAWLSPACE OR UNHEATED BASEMENT
TABLE A105.1(2) DEFAULT U-FACTORS FOR FLOORS OVER HEATED PLENUM CRAWLSPACES
TABLE A105.1(3) DEFAULT U-FACTORS FOR EXPOSED FLOORS
198 SECTION A106 ON-GRADE SLAB FLOORS
TABLE A106.1 DEFAULT F-FACTORS FOR ON-GRADE SLABS
SECTION A107 DEFAULT U-FACTORS FOR DOORS
199 TABLE A107.1(1) DEFAULT U-FACTORS FOR DOORS
200 TABLE A107.1(2) DEFAULT U-FACTORS FOR REVOLVING DOORS
TABLE A107.1(3) DEFAULT U-FACTORS FOR STEEL EMERGENCY DOORS
TABLE A107.1(4) DEFAULT U-FACTORS FOR STEEL GARAGE AND HANGAR DOORS
201 SECTION A108 AIR INFILTRATION
TABLE A108.1(1) ASSUMED EFFECTIVE AIR CHANGES PER HOUR
TABLE A108.1(2) DEFAULT HEAT CAPACITY/DENSITY PRODUCT FOR AIR
203 APPENDIX B DEFAULT INTERNAL LOAD VALUES AND SCHEDULES
SECTION B101 GENERAL
SECTION B102 DEFAULT TABLES OF INTERNAL LOADS
TABLE B102 ACCEPTABLE OCCUPANCY DENSITIES, RECEPTACLE POWER DENSITIES AND SERVICE HOT WATER CONSUMPTIONa
SECTION B103 DEFAULT SCHEDULES
204 TABLE B103(1) ASSEMBLY OCCUPANCYa
205 TABLE B103(2) HEALTH OCCUPANCYa
206 TABLE B103(3) HOTEL/MOTEL OCCUPANCYa
207 TABLE B103(4) LIGHT MANUFACTURING OCCUPANCYa
208 TABLE B103(5) OFFICE OCCUPANCYa
209 TABLE B103(6) PARKING GARAGE OCCUPANCYa
210 TABLE B103(7) RESTAURANT OCCUPANCYa
211 TABLE B103(8) RETAIL OCCUPANCYa
212 TABLE B103(9) SCHOOL OCCUPANCYa
213 TABLE B103(10) WAREHOUSE OCCUPANCYa
215 APPENDIX C EXTERIOR DESIGN CONDITIONS
TABLE C-1 OUTDOOR DESIGN TEMPERATURES
TABLE C-1 OUTDOOR DESIGN TEMPERATURES—continued
216 TABLE C-1 OUTDOOR DESIGN TEMPERATURES—continued
217 APPENDIX D TOTAL BUILDING PERFORMANCE REPORTING FORMAT
221 ENERGY ANALYSIS SUMMARY FORM PROJECT INFORMATION
WA SeattleEnergyCode 2012
$28.17