Shopping Cart

No products in the cart.

WA StateBuildingCode 1stptg 2018.pdf

$69.17

Washington State Building Code

Published By Publication Date Number of Pages
WA 2018 771
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

2020 City of Los Angeles amendment pages for integration with the 2019 California Building Code

PDF Catalog

PDF Pages PDF Title
1 2018 WASHINGTON STATE BUILDING CODE BASED ON THE 2018 INTERNATIONAL BUILDING CODE®
2 2018 WASHINGTON STATE BUILDING CODE BASED ON THE 2018 INTERNATIONAL BUILDING CODE® TITLE PAGE
3 COPYRIGHT
4 PREFACE
12 EFFECTIVE USE OF THE INTERNATIONAL BUILDING CODE
22 TABLE OF CONTENTS
30 CHAPTER 1 SCOPE AND ADMINISTRATION
PART 1—SCOPE AND APPLICATION
WAC 51-50-001 AUTHORITY
WAC 51-50-002 PURPOSE
WAC 51-50-003 INTERNATIONAL BUILDING CODE
WAC 51-50-005 INTERNATIONAL BUILDING CODE REQUIREMENTS FOR BARRIER-FREE ACCESSIBILITY
WAC 51-50-007 EXCEPTIONS
WAC 51-50-008 IMPLEMENTATION
31 WAC 51-50-009 RECYCLABLE MATERIALS, COMPOST, AND SOLID WASTE STORAGE
SECTION 101 GENERAL
SECTION 102 APPLICABILITY
32 PART 2—ADMINISTRATION AND ENFORCEMENT
SECTION 103 DEPARTMENT OF BUILDING SAFETY
SECTION 104 DUTIES AND POWERS OF BUILDING OFFICIAL
34 SECTION 105 PERMITS
35 SECTION 106 FLOOR AND ROOF DESIGN LOADS
36 SECTION 107 SUBMITTAL DOCUMENTS
37 SECTION 108 TEMPORARY STRUCTURES AND USES
SECTION 109 FEES
38 SECTION 110 INSPECTIONS
39 SECTION 111 CERTIFICATE OF OCCUPANCY
SECTION 112 SERVICE UTILITIES
SECTION 113 BOARD OF APPEALS
40 SECTION 114 VIOLATIONS
SECTION 115 STOP WORK ORDER
SECTION 116 UNSAFE STRUCTURES AND EQUIPMENT
42 CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 DEFINITIONS
74 CHAPTER 3 OCCUPANCY CLASSIFICATION AND USE
SECTION 301 SCOPE
SECTION 302 OCCUPANCY CLASSIFICATION AND USE DESIGNATION
SECTION 303 ASSEMBLY GROUP A
75 SECTION 304 BUSINESS GROUP B
SECTION 305 EDUCATIONAL GROUP E
76 SECTION 306 FACTORY GROUP F
SECTION 307 HIGH-HAZARD GROUP H
77 TABLE 307.1(1) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
78 TABLE 307.1(1)—continued MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
79 [F] TABLE 307.1(2) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A HEALTH HAZARD
80 SECTION 308 INSTITUTIONAL GROUP I
82 SECTION 309 MERCANTILE GROUP M
SECTION 310 RESIDENTIAL GROUP R
SECTION 311 STORAGE GROUP S
83 SECTION 312 UTILITY AND MISCELLANEOUS GROUP U
84 CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON OCCUPANCY AND USE
SECTION 401 SCOPE
SECTION 402 COVERED MALL AND OPEN MALL BUILDINGS
87 EQUATION 4-1
88 SECTION 403 HIGH-RISE BUILDINGS
89 TABLE 403.2.4 MINIMUM BOND STRENGTH
91 SECTION 404 ATRIUMS
92 SECTION 405 UNDERGROUND BUILDINGS
93 SECTION 406 MOTOR-VEHICLE-RELATED OCCUPANCIES
95 TABLE 406.5.4 OPEN PARKING GARAGES AREA AND HEIGHT
97 SECTION 407 GROUP I-2
100 SECTION 408 GROUP I-3
102 SECTION 409 MOTION PICTURE PROJECTION ROOMS
103 SECTION 410 STAGES, PLATFORMS AND TECHNICAL PRODUCTION AREAS
105 SECTION 411 SPECIAL AMUSEMENT BUILDINGS
SECTION 412 AIRCRAFT-RELATED OCCUPANCIES
106 TABLE 412.2.1.1 HEIGHT LIMITATIONS FOR AIRPORT TRAFFIC CONTROL TOWERS
107 [F] TABLE 412.3.6 HANGAR FIRE SUPPRESSION REQUIREMENTS
109 TABLE 412.6 AIRCRAFT MANUFACTURING EXIT ACCESS TRAVEL DISTANCE
SECTION 413 COMBUSTIBLE STORAGE
SECTION 414 HAZARDOUS MATERIALS
110 [F] TABLE 414.2.2 DESIGN AND NUMBER OF CONTROL AREAS
111 [F] TABLE 414.2.5(1) MAXIMUM ALLOWABLE QUANTITY PER INDOOR AND OUTDOOR CONTROL AREA IN GROUP M AND S OCCUPANCIES NONFLAMMABLE SOLIDS AND NONFLAMMABLE AND NONCOMBUSTIBLE LIQUIDSd, e, f
112 [F] TABLE 414.2.5(2) MAXIMUM ALLOWABLE QUANTITY OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN WHOLESALE AND RETAIL SALES OCCUPANCIES PER CONTROL AREAa
SECTION 415 GROUPS H-1, H-2, H-3, H-4 AND H-5
113 [F] TABLE 414.5.1 EXPLOSION CONTROL REQUIREMENTS
115 [F] TABLE 415.6.2 DETACHED BUILDING REQUIRED
117 [F] TABLE 415.11.1.1.1 QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5
122 SECTION 416 SPRAY APPLICATION OF FLAMMABLE FINISHES
123 SECTION 417 DRYING ROOMS
SECTION 418 ORGANIC COATINGS
SECTION 419 LIVE/WORK UNITS
124 SECTION 420 GROUPS I-1, R-1, R-2 AND R-3
126 SECTION 421 HYDROGEN FUEL GAS ROOMS
127 SECTION 422 AMBULATORY CARE FACIILITIES
SECTION 423 STORM SHELTERS
128 SECTION 424 CHILDREN’S PLAY STRUCTURES
SECTION 425 HYPERBARIC FACILITIES
SECTION [F] 426 COMBUSTIBLE DUSTS, GRAIN PROCESSING AND STORAGE
129 SECTION 427 MEDICAL GAS SYSTEMS
130 SECTION 428 HIGHER EDUCATION LABORATORIES
[F] TABLE 428.3 DESIGN AND NUMBER OF LABORATORY SUITES PER FLOOR
131 SECTION 429 ELECTRIC VEHICLE CHARGING INFRASTRUCTURE
132 CHAPTER 5 GENERAL BUILDING HEIGHTS AND AREAS
SECTION 501 GENERAL
SECTION 502 BUILDING ADDRESS
SECTION 503 GENERAL BUILDING HEIGHT AND AREA LIMITATIONS
133 SECTION 504 BUILDING HEIGHT AND NUMBER OF STORIES
TABLE 504.3 ALLOWABLE BUILDING HEIGHT IN FEET ABOVE GRADE PLANEa
134 SECTION 505 MEZZANINES AND EQUIPMENT PLATFORMS
135 TABLE 504.4 ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE
136 TABLE 504.4—continued ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE
137 SECTION 506 BUILDING AREA
EQUATION 5-1
EQUATION 5-2
138 TABLE 506.2 ALLOWABLE AREA FACTOR (At = NS, S1, S13R, S13D or SM, as applicable) IN SQUARE FEET
139 TABLE 506.2—continued ALLOWABLE AREA FACTOR (At = NS, S1, S13R, S13D or SM, as applicable) IN SQUARE FEET
140 TABLE 506.2—continued ALLOWABLE AREA FACTOR (At = NS, S1, S13R, S13D or SM, as applicable) IN SQUARE FEET
EQUATION 5-3
EQUATION 5-4
141 EQUATION 5-5
SECTION 507 UNLIMITED AREA BUILDINGS
143 SECTION 508 MIXED USE AND OCCUPANCY
144 TABLE 508.4 REQUIRED SEPARATION OF OCCUPANCIES (HOURS)f
SECTION 509 INCIDENTAL USES
145 [F] TABLE 509 INCIDENTAL USES
146 SECTION 510 SPECIAL PROVISIONS
148 CHAPTER 6 TYPES OF CONSTRUCTION
SECTION 601 GENERAL
TABLE 601 FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS)
SECTION 602 CONSTRUCTION CLASSIFICATION
149 TABLE 602 FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE
150 EQUATION 6-1
152 SECTION 603 COMBUSTIBLE MATERIAL IN TYPES I AND II CONSTRUCTION
154 CHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES
SECTION 701 GENERAL
SECTION 702 MULTIPLE USE FIRE ASSEMBLIES
SECTION 703 FIRE-RESISTANCE RATINGS AND FIRE TESTS
155 SECTION 704 FIRE-RESISTANCE RATING OF STRUCTURAL MEMBERS
157 SECTION 705 EXTERIOR WALLS
TABLE 705.2 MINIMUM DISTANCE OF PROJECTION
158 EQUATION 7-1
159 EQUATION 7-2
FIGURE 705.7 EQUIVALENT OPENING FACTOR
160 TABLE 705.8 MAXIMUM AREA OF EXTERIOR WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE AND DEGREE OF OPENING PROTECTION
162 SECTION 706 FIRE WALLS
TABLE 706.4 FIRE WALL FIRE-RESISTANCE RATINGS
164 SECTION 707 FIRE BARRIERS
165 TABLE 707.3.10 FIRE-RESISTANCE RATING REQUIREMENTS FOR FIRE BARRIERS, FIRE WALLS OR HORIZONTAL ASSEMBLIES BETWEEN FIRE AREAS
166 SECTION 708 FIRE PARTITIONS
167 SECTION 709 SMOKE BARRIERS
SECTION 710 SMOKE PARTITIONS
168 SECTION 711 FLOOR AND ROOF ASSEMBLIES
169 SECTION 712 VERTICAL OPENINGS
170 SECTION 713 SHAFT ENCLOSURES
172 SECTION 714 PENETRATIONS
175 SECTION 715 FIRE-RESISTANT JOINT SYSTEMS
SECTION 716 OPENING PROTECTIVES
176 TABLE 716.1(1) MARKING FIRE-RATED GLAZING ASSEMBLIES
177 TABLE 716.1(2) OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS
178 TABLE 716.1(2)—continued OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS
TABLE 716.1(3) FIRE WINDOW ASSEMBLY FIRE PROTECTION RATINGS
182 SECTION 717 DUCTS AND AIR TRANSFER OPENINGS
183 TABLE 717.3.2.1 FIRE DAMPER RATING
187 SECTION 718 CONCEALED SPACES
188 SECTION 719 FIRE-RESISTANCE REQUIREMENTS FOR PLASTER
189 SECTION 720 THERMAL- AND SOUND-INSULATING MATERIALS
190 SECTION 721 PRESCRIPTIVE FIRE RESISTANCE
SECTION 722 CALCULATED FIRE RESISTANCE
TABLE 722.2.1.1 MINIMUM EQUIVALENT THICKNESS OF CAST-IN-PLACE OR PRECAST CONCRETE WALLS, LOAD-BEARING OR NONLOAD-BEARING
191 TABLE 721.1(1) MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
192 TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
193 TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
194 TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
195 TABLE 721.1(2) RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
196 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
197 TABLE 721.1(2) —continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
198 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
199 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
200 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
201 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
202 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
203 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
TABLE 721.1(3) MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
204 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
205 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
206 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
207 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
208 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
209 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
210 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
211 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
212 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
213 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
214 EQUATION 7-3
EQUATION 7-4
FIGURE 722.2.1.2 FIRE-RESISTANCE RATINGS OF TWO-WYTHE CONCRETE WALLS
215 TABLE 722.2.1.2(1) VALUES OF Rn0.59 FOR USE IN EQUATION 7-4
TABLE 722.2.1.2(2) FIRE-RESISTANCE RATINGS BASED ON R0.59
FIGURE 722.2.1.3.1 CERAMIC FIBER JOINT PROTECTION
216 TABLE 722.2.1.4(1) MULTIPLYING FACTOR FOR FINISHES ON NONFIRE-EXPOSED SIDE OF WALL
TABLE 722.2.1.4(2) TIME ASSIGNED TO FINISH MATERIALS ON FIRE-EXPOSED SIDE OF WALL
TABLE 722.2.2.1 MINIMUM SLAB THICKNESS (inches)
217 FIGURE 722.2.2.1.2 DETERMINATION OF SLAB THICKNESS FOR SLOPING SOFFITS
EQUATION 7-5
FIGURE 722.2.2.1.3 SLABS WITH RIBBED OR UNDULATING SOFFITS
FIGURE 722.2.2.2 FIRE-RESISTANCE RATINGS FOR TWO-COURSE CONCRETE FLOORS
218 FIGURE 722.2.2.3(1) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES
FIGURE 722.2.2.3(2) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES
TABLE 722.2.3(1) COVER THICKNESS FOR REINFORCED CONCRETE FLOOR OR ROOF SLABS
219 TABLE 722.2.3(2) COVER THICKNESS FOR PRESTRESSED CONCRETE FLOOR OR ROOF SLABS (inches)
TABLE 722.2.3(3) MINIMUM COVER FOR MAIN REINFORCING BARS OF REINFORCED CONCRETE BEAMSc(APPLICABLE TO ALL TYPES OF STRUCTURAL CONCRETE)
TABLE 722.2.3(4) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS 8 INCHES OR GREATER IN WIDTH
220 TABLE 722.2.3(5) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS OF ALL WIDTHS
TABLE 722.2.4 MINIMUM DIMENSION OF CONCRETE COLUMNS (inches)
221 EQUATION 7-6
TABLE 722.3.2 MINIMUM EQUIVALENT THICKNESS (inches) OF BEARING OR NONBEARING CONCRETE MASONRY WALLS
222 EQUATION 7-7
TABLE 722.3.4 MINIMUM COVER OF LONGITUDINAL REINFORCEMENT IN FIRE-RESISTANCE-RATED REINFORCED CONCRETE MASONRY LINTELS (inches)
TABLE 722.3.5 MINIMUM DIMENSION OF CONCRETEMASONRY COLUMNS (inches)
EQUATION 7-8
TABLE 722.4.1(1) FIRE-RESISTANCE PERIODS OF CLAY MASONRY WALLS
223 TABLE 722.4.1(2) FIRE-RESISTANCE RATINGS FOR BEARING STEEL FRAME BRICK VENEER WALLS OR PARTITIONS
EQUATION 7-9
TABLE 722.4.1(3) VALUES OF Rn 0.59
TABLE 722.4.1(4) COEFFICIENTS FOR PLASTER, pl a
TABLE 722.4.1(5) REINFORCED MASONRY LINTELS
TABLE 722.4.1(6) REINFORCED CLAY MASONRY COLUMNS
224 EQUATION 7-10
EQUATION 7-11
FIGURE 722.5.1(1) DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL COLUMNS
EQUATION 7-12
225 EQUATION 7-13
EQUATION 7-14
EQUATION 7-15
226 FIGURE 722.5.1(2) GYPSUM-PROTECTED STRUCTURAL STEEL COLUMNS WITH SHEET STEEL COLUMN COVERS
FIGURE 722.5.1(3) GYPSUM-PROTECTED STRUCTURAL STEEL COLUMNS WITH STEEL STUD/SCREW ATTACHMENT SYSTEM
227 FIGURE 722.5.1(4) FIRE RESISTANCE OF STRUCTURAL STEEL COLUMNS PROTECTED WITH VARIOUS THICKNESSES OF TYPE X GYPSUM WALLBOARD
FIGURE 722.5.1(5) WIDE FLANGE STRUCTURAL STEEL COLUMNS WITH SPRAYED FIRE-RESISTANT MATERIALS
FIGURE 722.5.1(6) CONCRETE PROTECTED STRUCTURAL STEEL COLUMNS
228 FIGURE 722.5.1(7) CONCRETE OR CLAY MASONRY PROTECTED STRUCTURAL STEEL COLUMNS
EQUATION 7-16
229 FIGURE 722.5.2 DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL BEAMS AND GIRDERS
EQUATION 7-17
230 TABLE 722.5.1(1) W/D RATIOS FOR STEEL COLUMNS
TABLE 722.5.1(2) PROPERTIES OF CONCRETE
231 TABLE 722.5.1(3 )THERMAL CONDUCTIVITY OF CONCRETE OR CLAY MASONRY UNITS
TABLE 722.5.1(4) WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
232 TABLE 722.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
233 TABLE 722.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
234 TABLE 722.5.1(5) FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
235 TABLE 722.5.1(5)—continued FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
236 TABLE 722.5.1(6 ) FIRE RESISTANCE OF CLAY MASONRY PROTECTED STEEL COLUMNS
237 TABLE 722.5.1(7) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN NORMAL-WEIGHT CONCRETEa [FIGURE 722.5.1(6)(c)]
TABLE 722.5.1(8) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN STRUCTURAL LIGHTWEIGHT CONCRETEa [FIGURE 722.5.1(6)(c)]
238 TABLE 722.5.1(9) MINIMUM COVER (inch) FOR STEEL COLUMNS IN NORMAL-WEIGHT PRECAST COVERSa [FIGURE 722.5.1(6)(a)]
TABLE 722.5.1(10) MINIMUM COVER (inch) FOR STEEL COLUMNS IN STRUCTURAL LIGHTWEIGHT PRECAST COVERSa [FIGURE 722.5.1(6)(a)]
239 TABLE 722.6.2(1) TIME ASSIGNED TO WALLBOARD MEMBRANES
240 TABLE 722.6.2(2) TIME ASSIGNED FOR CONTRIBUTION OF WOOD FRAME
TABLE 722.6.2(3) MEMBRANEa ON EXTERIOR FACE OF WOOD STUD WALLS
TABLE 722.6.2(4) FLOORING OR ROOFING OVER WOOD FRAMING
TABLE 722.6.2(5) TIME ASSIGNED FOR ADDITIONAL PROTECTION
241 TABLE 722.7.1(1) PROTECTION REQUIRED FROM NONCOMBUSTIBLE COVERING MATERIAL
TABLE 722.7.1(2) PROTECTION PROVIDED BY NONCOMBUSTIBLE COVERING MATERIAL
242 CHAPTER 8 INTERIOR FINISHES
SECTION 801 SCOPE
SECTION 802 GENERAL
SECTION 803 WALL AND CEILING FINISHES
244 TABLE 803.13 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY
245 SECTION 804 INTERIOR FLOOR FINISH
246 SECTION 805 COMBUSTIBLE MATERIALS IN TYPES I AND II CONSTRUCTION
SECTION 806 DECORATIVE MATERIALS AND TRIM
247 SECTION 807 INSULATION
SECTION 808 ACOUSTICAL CEILING SYSTEMS
248 CHAPTER 9 FIRE PROTECTION AND LIFE SAFETY SYSTEMS
SECTION 901 GENERAL
249 SECTION 902 FIRE PUMP AND RISER ROOM SIZE
SECTION 903 AUTOMATIC SPRINKLER SYSTEMS
251 [F] TABLE 903.2.5.2 GROUP H-5 SPRINKLER DESIGN CRITERIA
253 [F] TABLE 903.2.11.6 ADDITIONAL REQUIRED SUPPRESSION SYSTEMS
256 SECTION 904 ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS
258 SECTION 905 STANDPIPE SYSTEMS
261 SECTION 906 PORTABLE FIRE EXTINGUISHERS
[F] TABLE 906.1 ADDITIONAL REQUIRED PORTABLE FIRE EXTINGUISHERS IN THE INTERNATIONAL FIRE CODE
262 [F] TABLE 906.3(1) FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS
[F] TABLE 906.3(2) FIRE EXTINGUISHERS FOR FLAMMABLE OR COMBUSTIBLE LIQUIDS WITH DEPTHS LESS THAN OR EQUAL TO 0.25 INCHa
263 SECTION 907 FIRE ALARM AND DETECTION SYSTEMS
273 [F] TABLE 907.5.2.3.2 VISIBLE ALARMS
274 SECTION 908 EMERGENCY ALARM SYSTEMS
SECTION 909 SMOKE CONTROL SYSTEMS
276 EQUATION 9-1
EQUATION 9-2
282 SECTION 910 SMOKE AND HEAT REMOVAL
283 EQUATION 9-3
EQUATION 9-4
SECTION 911 FIRE COMMAND CENTER
285 SECTION 912 FIRE DEPARTMENT CONNECTIONS
SECTION 913 FIRE PUMPS
286 SECTION 914 EMERGENCY RESPONDER SAFETY FEATURES
SECTION 915 CARBON MONOXIDE DETECTION
288 SECTION 916 GAS DETECTION SYSTEMS
SECTION 917 MASS NOTIFICATION SYSTEMS
SECTION 918 EMERGENCY RESPONDER RADIO COVERAGE
290 CHAPTER 10 MEANS OF EGRESS
SECTION 1001 ADMINISTRATION
[F] SECTION 1002 MAINTENANCE AND PLANS
SECTION 1003 GENERAL MEANS OF EGRESS
291 SECTION 1004 OCCUPANT LOAD
292 TABLE 1004.5 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT
293 SECTION 1005 MEANS OF EGRESS SIZING
294 SECTION 1006 NUMBER OF EXITS AND EXIT ACCESS DOORWAYS
295 TABLE 1006.2.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY
296 TABLE 1006.3.2 MINIMUM NUMBER OF EXITS OR ACCESS TO EXITS PER STORY
TABLE 1006.3.3(1) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR R-2 OCCUPANCIES
TABLE 1006.3.3(2) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR OTHER OCCUPANCIES
297 SECTION 1007 EXIT AND EXIT ACCESS DOORWAY CONFIGURATION
SECTION 1008 MEANS OF EGRESS ILLUMINATION
298 SECTION 1009 ACCESSIBLE MEANS OF EGRESS
301 SECTION 1010 DOORS, GATES AND TURNSTILES
302 TABLE 1010.1.4.1(1) MAXIMUM DOOR SPEED MANUAL REVOLVING DOORS
303 TABLE 1010.1.4.1(2) MAXIMUM DOOR SPEED AUTOMATIC OR POWER-OPERATED REVOLVING DOORS
310 SECTION 1011 STAIRWAYS
314 SECTION 1012 RAMPS
315 SECTION 1013 EXIT SIGNS
316 SECTION 1014 HANDRAILS
317 SECTION 1015 GUARDS
319 SECTION 1016 EXIT ACCESS
SECTION 1017 EXIT ACCESS TRAVEL DISTANCE
320 TABLE 1017.2 EXIT ACCESS TRAVEL DISTANCEa
SECTION 1018 AISLES
SECTION 1019 EXIT ACCESS STAIRWAYS AND RAMPS
321 SECTION 1020 CORRIDORS
TABLE 1020.1 CORRIDOR FIRE-RESISTANCE RATING
322 TABLE 1020.2 MINIMUM CORRIDOR WIDTH
323 SECTION 1021 EGRESS BALCONIES
SECTION 1022 EXITS
SECTION 1023 INTERIOR EXIT STAIRWAYS AND RAMPS
325 SECTION 1024 EXIT PASSAGEWAYS
326 SECTION 1025 LUMINOUS EGRESS PATH MARKINGS
327 SECTION 1026 HORIZONTAL EXITS
328 SECTION 1027 EXTERIOR EXIT STAIRWAYS AND RAMPS
329 SECTION 1028 EXIT DISCHARGE
330 SECTION 1029 ASSEMBLY
331 TABLE 1029.6.2 CAPACITY FOR AISLES FOR SMOKE-PROTECTED ASSEMBLY
334 TABLE 1029.13.2.1 SMOKE-PROTECTED OR OPEN-AIR ASSEMBLY AISLE ACCESSWAYS
337 SECTION 1030 EMERGENCY ESCAPE AND RESCUE
338 CHAPTER 11 ACCESSIBILITY
SECTION 1101 GENERAL
339 SECTION 1102 COMPLIANCE
SECTION 1103 SCOPING REQUIREMENTS
SECTION 1104 ACCESSIBLE ROUTE
341 SECTION 1105 ACCESSIBLE ENTRANCES
TABLE 1105.1.8 PUBLIC ENTRANCE WITH POWER-OPERATED DOORSa
SECTION 1106 PARKING AND PASSENGER LOADING FACILITIES
342 TABLE 1106.1 ACCESSIBLE PARKING SPACES
SECTION 1107 DWELLING UNITS AND SLEEPING UNITS
343 TABLE 1107.6.1.1 ACCESSIBLE DWELLING UNITS AND SLEEPING UNITS
346 SECTION 1108 SPECIAL OCCUPANCIES
347 TABLE 1108.2.2.1 ACCESSIBLE WHEELCHAIR SPACES
TABLE 1108.2.7.1 RECEIVERS FOR ASSISTIVE LISTENING SYSTEMS
348 TABLE 1108.3 ACCESSIBLE SELF-SERVICE STORAGE FACILITIES
349 SECTION 1109 OTHER FEATURES AND FACILITIES
352 TABLE 1109.12.2 ACCESSIBLE CHECK-OUT AISLES
353 SECTION 1110 RECREATIONAL FACILITIES
354 TABLE 1110.4.9.1 BOAT SLIPS
355 SECTION 1111 SIGNAGE
358 CHAPTER 12 INTERIOR ENVIRONMENT
SECTION 1201 GENERAL
SECTION 1202 VENTILATION
359 TABLE 1202.3 INSULATION FOR CONDENSATION CONTROL
362 SECTION 1203 TEMPERATURE CONTROL
363 SECTION 1204 LIGHTING
SECTION 1205 YARDS OR COURTS
SECTION 1206 SOUND TRANSMISSION
364 SECTION 1207 INTERIOR SPACE DIMENSIONS
SECTION 1208 ACCESS TO UNOCCUPIED SPACES
SECTION 1209 TOILET AND BATHROOM REQUIREMENTS
366 CHAPTER 13 ENERGY EFFICIENCY
SECTION 1301 GENERAL
368 CHAPTER 14 EXTERIOR WALLS
SECTION 1401 GENERAL
SECTION 1402 PERFORMANCE REQUIREMENTS
369 SECTION 1403 MATERIALS
SECTION 1404 INSTALLATION OF WALL COVERINGS
370 TABLE 1404.2 MINIMUM THICKNESS OF WEATHER COVERINGS
TABLE 1404.3.2 CLASS III VAPOR RETARDERS
375 SECTION 1405 COMBUSTIBLE MATERIALS ON THE EXTERIOR SIDE OF EXTERIOR WALLS
TABLE 1405.1.1.1.2 MINIMUM FIRE SEPARATION FOR COMBUSTIBLE EXTERIOR WALL COVERINGS
376 SECTION 1406 METAL COMPOSITE MATERIALS (MCM)
377 TABLE 1406.11.3.4 AREA LIMITATION AND SEPARATION REQUIREMENTS FOR MCM PANELS
378 SECTION 1407 EXTERIOR INSULATION AND FINISH SYSTEMS (EIFS)
SECTION 1408 HIGH-PRESSURE DECORATIVE EXTERIOR-GRADE COMPACT LAMINATES (HPL)
379 SECTION 1409 PLASTIC COMPOSITE DECKING
380 CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
SECTION 1501 GENERAL
SECTION 1502 ROOF DRAINAGE
SECTION 1503 WEATHER PROTECTION
381 SECTION 1504 PERFORMANCE REQUIREMENTS
TABLE 1504.1.1 CLASSIFICATION OF STEEP SLOPE ROOF SHINGLES TESTED IN ACCORDANCE WITH ASTM D3161 OR D7158
382 TABLE 1504.8 MAXIMUM ALLOWABLE MEAN ROOF HEIGHT PERMITTED FOR BUILDINGS WITH AGGREGATE ON THE ROOF IN AREAS OUTSIDE A HURRICANE-PRONE REGION
SECTION 1505 FIRE CLASSIFICATION
TABLE 1505.1a, b MINIMUM ROOF COVERING CLASSIFICATION FOR TYPES OF CONSTRUCTION
383 SECTION 1506 MATERIALS
SECTION 1507 REQUIREMENTS FOR ROOF COVERINGS
384 TABLE 1507.1.1(1) UNDERLAYMENT TYPES
385 TABLE 1507.1.1(2) UNDERLAYMENT APPLICATION
386 TABLE 1507.1.1(3) UNDERLAYMENT ATTACHMENT
387 TABLE 1507.2.8.2 VALLEY LINING MATERIAL
388 TABLE 1507.3.7 CLAY AND CONCRETE TILE ATTACHMENT
389 TABLE 1507.4.3(1) METAL ROOF COVERINGS
TABLE 1507.4.3(2) MINIMUM CORROSION RESISTANCE
390 TABLE 1507.7.6 SLATE SHINGLE HEADLAP
TABLE 1507.8.5 WOOD SHINGLE MATERIAL REQUIREMENTS
TABLE 1507.8.7 WOOD SHINGLE WEATHER EXPOSURE AND ROOF SLOPE
391 TABLE 1507.8 WOOD SHINGLE AND SHAKE INSTALLATION
392 TABLE 1507.9.6 WOOD SHAKE MATERIAL REQUIREMENTS
TABLE 1507.9.8 WOOD SHAKE WEATHER EXPOSURE AND ROOF SLOPE
393 TABLE 1507.10.2 BUILT-UP ROOFING MATERIAL STANDARDS
TABLE 1507.14.3 PROTECTIVE COATING MATERIAL STANDARDS
395 SECTION 1508 ROOF INSULATION
[BF] TABLE 1508.2 MATERIAL STANDARDS FOR ROOF INSULATION
SECTION 1509 RADIANT BARRIERS INSTALLED ABOVE DECK
SECTION 1510 ROOFTOP STRUCTURES
397 SECTION 1511 REROOFING
398 SECTION 1512 PHOTOVOLTAIC PANELS AND MODULES
400 CHAPTER 16 STRUCTURAL DESIGN
SECTION 1601 GENERAL
SECTION 1602 NOTATIONS
SECTION 1603 CONSTRUCTION DOCUMENTS
401 SECTION 1604 GENERAL DESIGN REQUIREMENTS
402 TABLE 1604.3 DEFLECTION LIMITS
403 TABLE 1604.5 RISK CATEGORY OF BUILDINGS AND OTHER STRUCTURES
404 SECTION 1605 LOAD COMBINATIONS
405 EQUATION 16-1
EQUATION 16-2
EQUATION 16-3
EQUATION 16-4
EQUATION 16-5
EQUATION 16-6
EQUATION 16-7
EQUATION 16-8
EQUATION 16-9
EQUATION 16-10
EQUATION 16-11
EQUATION 16-12
EQUATION 16-13
EQUATION 16-14
EQUATION 16-15
EQUATION 16-16
406 EQUATION 16-17
EQUATION 16-18
EQUATION 16-19
EQUATION 16-20
EQUATION 16-21
EQUATION 16-22
SECTION 1606 DEAD LOADS
SECTION 1607 LIVE LOADS
407 TABLE 1607.1 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0, AND MINIMUM CONCENTRATED LIVE LOADSg
TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0, AND MINIMUM CONCENTRATED LIVE LOADSg
408 TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0, AND MINIMUM CONCENTRATED LIVE LOADSg
TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, Lo, AND MINIMUM CONCENTRATED LIVE LOADSg
410 EQUATION 16-23
TABLE 1607.11.1 LIVE LOAD ELEMENT FACTOR, KLL
411 EQUATION 16-24
EQUATION 16-25
EQUATION 16-26
EQUATION 16-27
EQUATION 16-28
EQUATION 16-29
EQUATION 16-30
EQUATION 16-31
EQUATION 16-32
413 SECTION 1608 SNOW LOADS
TABLE 1608.2 GROUND SNOW LOADS, pg, FOR ALASKAN LOCATIONS
SECTION 1609 WIND LOADS
414 TABLE 1609.2 WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELSa, b, c, d
415 FIGURE 1608.2 GROUND SNOW LOADS, pg, FOR THE UNITED STATES (psf)
416 FIGURE 1608.2—continued GROUND SNOW LOADS, pg, FOR THE UNITED STATES (psf)
417 EQUATION 16-33
TABLE 1609.3.1 WIND SPEED CONVERSIONS
418 FIGURE 1609.3(1) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY II BUILDINGS AND OTHER STRUCTURES
419 FIGURE 1609.3(2) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY III BUILDINGS AND OTHER STRUCTURES
420 FIGURE 1609.3(3) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY IV BUILDINGS AND OTHER STRUCTURES
421 FIGURE 1609.3(4) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY I BUILDINGS AND OTHER STRUCTURES
422 FIGURE 1609.3(5) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY II BUILDINGS AND OTHER STRUCTURES IN HAWAII
423 FIGURE 1609.3(5)—continued BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY II BUILDINGS AND OTHER STRUCTURES IN HAWAII
424 FIGURE 1609.3(6) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY III BUILDINGS AND OTHER STRUCTURES IN HAWAII
425 FIGURE 1609.3(6)—continued BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY III BUILDINGS AND OTHER STRUCTURES IN HAWAII
426 FIGURE 1609.3(7) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY IV BUILDINGS AND OTHER STRUCTURES IN HAWAII
427 FIGURE 1609.3(7)—continued BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY IV BUILDINGS AND OTHER STRUCTURES IN HAWAII
428 FIGURE 1609.3(8) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY I BUILDINGS AND OTHER STRUCTURES IN HAWAII
429 FIGURE 1609.3(8)—continued BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY I BUILDINGS AND OTHER STRUCTURES IN HAWAII
430 EQUATION 16-34
SECTION 1610 SOIL LATERAL LOADS
SECTION 1611 RAIN LOADS
EQUATION 16-35
431 TABLE 1610.1 LATERAL SOIL LOAD
SECTION 1612 FLOOD LOADS
432 SECTION 1613 EARTHQUAKE LOADS
433 [P] FIGURE 1611.1 100-YEAR, 1-HOUR RAINFALL (INCHES) WESTERN UNITED STATES
434 [P] FIGURE 1611.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) CENTRAL UNITED STATES
435 [P] FIGURE 1611.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) EASTERN UNITED STATES
436 [P] FIGURE 1611.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) ALASKA
437 [P] FIGURE 1611.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) HA
438 EQUATION 16-36
EQUATION 16-37
TABLE 1613.2.3(1) VALUES OF SITE COEFFICIENT Fa a
EQUATION 16-38
EQUATION 16-39
439 TABLE 1613.2.3(2) VALUES OF SITE COEFFICIENT FV a
TABLE 1613.2.5(1) SEISMIC DESIGN CATEGORY BASED ON SHORT-PERIOD (0.2 second) RESPONSE ACCELERATION
TABLE 1613.2.5(2) SEISMIC DESIGN CATEGORY BASED ON 1-SECOND PERIOD RESPONSE ACCELERATION
441 TABLE 12.6-1 PERMITTED ANALYTICAL PROCEDURES
SECTION 1614 ATMOSPHERIC ICE LOADS
SECTION 1615 TSUNAMI LOADS
SECTION 1616 STRUCTURAL INTEGRITY
442 EQUATION 16-40
EQUATION 16-41
443 FIGURE 1613.2.1(1) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THE CONTERMINOUS UNITED STATES OF 0.2-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
444 FIGURE 1613.2.1(1)—continued RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THE CONTERMINOUS UNITED STATES OF 0.2-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
445 FIGURE 1613.2.1(2) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THE CONTERMINOUS UNITED STATES OF 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
446 FIGURE 1613.2.1(2)—continued RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THE CONTERMINOUS UNITED STATES OF 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
447 FIGURE 1613.2.1(3) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR HAWAII OF 0.2- AND 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
448 FIGURE 1613.2.1(4) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR ALASKA OF 0.2-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
449 FIGURE 1613.2.1(5)
RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS
FOR ALASKA OF 1.0-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
450 FIGURE 1613.2.1(6) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR PUERTO RICO AND THE UNITED STATES VIRGIN ISLANDS OF 0.2- AND 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
451 FIGURE 1613.2.1(7) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR GUAM AND THE NORTHERN MARIANA ISLANDS OF 0.2- AND 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
452 FIGURE 1613.2.1(8) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR AMERICAN SAMOA OF 0.2- AND 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
453 FIGURE 1616.3 LONGITUDINAL, PERIMETER, TRANSVERSE AND VERTICAL TIES
454 CHAPTER 17 SPECIAL INSPECTIONS AND TESTS
SECTION 1701 GENERA
SECTION 1702 NEW MATERIALS
SECTION 1703 APPROVALS
455 SECTION 1704 SPECIAL INSPECTIONS AND TESTS, CONTRACTOR RESPONSIBILITY AND STRUCTURAL OBSERVATION
457 SECTION 1705 REQUIRED SPECIAL INSPECTIONS AND TESTS
458 TABLE 1705.2.3 REQUIRED SPECIAL INSPECTIONS OF OPEN-WEB STEEL JOISTS AND JOIST GIRDERS
459 TABLE 1705.3 REQUIRED SPECIAL INSPECTIONS AND TESTS OF CONCRETE CONSTRUCTION
460 TABLE 1705.5.3 REQUIRED SPECIAL INSPECTIONS OF MASS TIMBER CONSTRUCTION
TABLE 1705.6 REQUIRED SPECIAL INSPECTIONS AND TESTS OF SOILS
TABLE 1705.7 REQUIRED SPECIAL INSPECTIONS AND TESTS OF DRIVEN DEEP FOUNDATION ELEMENTS
461 TABLE 1705.8 REQUIRED SPECIAL INSPECTIONS AND TESTS OF CAST-IN-PLACE DEEP FOUNDATION ELEMENTS
466 SECTION 1706 DESIGN STRENGTHS OF MATERIALS
SECTION 1707 ALTERNATIVE TEST PROCEDURE
SECTION 1708 IN-SITU LOAD TESTS
SECTION 1709 PRECONSTRUCTION LOAD TESTS
468 CHAPTER 18 SOILS AND FOUNDATIONS
SECTION 1801 GENERAL
SECTION 1802 DESIGN BASIS
SECTION 1803 GEOTECHNICAL INVESTIGATIONS
470 SECTION 1804 EXCAVATION, GRADING AND FILL
471 SECTION 1805 DAMPPROOFING AND WATERPROOFING
472 SECTION 1806 PRESUMPTIVE LOAD-BEARING VALUES OF SOILS
473 TABLE 1806.2 PRESUMPTIVE LOAD-BEARING VALUES
SECTION 1807 FOUNDATION WALLS, RETAINING WALLS AND EMBEDDED POSTS AND POLES
475 TABLE 1807.1.6.2 CONCRETE FOUNDATION WALLS
476 TABLE 1807.1.6.3(1) PLAIN MASONRY FOUNDATION WALLS
EQUATION 18-1
477 TABLE 1807.1.6.3(2) 8-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≥ 5 INCHES
EQUATION 18-2
EQUATION 18-3
478 TABLE 1807.1.6.3(3) 10-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≥ 6.75 INCHES
SECTION 1808 FOUNDATIONS
479 TABLE 1807.1.6.3(4) 12-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≥ 8.75 INCHES
480 FIGURE 1808.7.1 FOUNDATION CLEARANCES FROM SLOPES
481 TABLE 1808.8.1 MINIMUM SPECIFIED COMPRESSIVE STRENGTH f′ C OF CONCRETE OR GROUT
TABLE 1808.8.2 MINIMUM CONCRETE COVER
482 SECTION 1809 SHALLOW FOUNDATIONS
TABLE 1809.7 PRESCRIPTIVE FOOTINGS SUPPORTING WALLS OF LIGHT-FRAME CONSTRUCTION
483 SECTION 1810 DEEP FOUNDATIONS
486 TABLE 1810.3.2.6 ALLOWABLE STRESSES FOR MATERIALS USED IN DEEP FOUNDATION ELEMENTS
487 EQUATION 18-4
490 EQUATION 18-5
EQUATION 18-6
EQUATION 18-7
EQUATION 18-8
491 EQUATION 18-9
EQUATION 18-10
498 CHAPTER 19 CONCRETE
SECTION 1901 GENERAL
SECTION 1902 DEFINITIONS
SECTION 1903 SPECIFICATIONS FOR TESTS AND MATERIALS
499 SECTION 1904 DURABILITY REQUIREMENTS
SECTION 1905 MODIFICATIONS TO ACI 318
501 SECTION 1906 STRUCTURAL PLAIN CONCRETE
SECTION 1907 MINIMUM SLAB PROVISIONS
502 SECTION 1908 SHOTCRETE
504 CHAPTER 20 ALUMINUM
SECTION 2001 GENERAL
SECTION 2002 MATERIALS
506 CHAPTER 21 MASONRY
SECTION 2101 GENERAL
SECTION 2102 NOTATIONS
SECTION 2103 MASONRY CONSTRUCTION MATERIALS
507 TABLE 2103.2.3 CERAMIC TILE MORTAR COMPOSITIONS
SECTION 2104 CONSTRUCTION
SECTION 2105 QUALITY ASSURANCE
SECTION 2106 SEISMIC DESIGN
SECTION 2107 ALLOWABLE STRESS DESIGN
508 EQUATION 21-1
SECTION 2108 STRENGTH DESIGN OF MASONRY
SECTION 2109 EMPIRICAL DESIGN OF ADOBE MASONRY
509 EQUATION 21-2
TABLE 2109.2.3.1 ALLOWABLE SHEAR ON BOLTS IN ADOBE MASONRY
510 SECTION 2110 GLASS UNIT MASONRY
SECTION 2111 MASONRY FIREPLACES
512 FIGURE 2111.12 ILLUSTRATION OF EXCEPTION TO FIREPLACE CLEARANCE PROVISION
513 SECTION 2112 MASONRY HEATERS
SECTION 2113 MASONRY CHIMNEYS
516 FIGURE 2113.16 FLUE SIZES FOR MASONRY CHIMNEYS
TABLE 2113.16(1) NET CROSS-SECTIONAL AREA OF ROUND FLUE SIZES
517 TABLE 2113.16(2) NET CROSS-SECTIONAL AREA OF SQUARE AND RECTANGULAR FLUE SIZES
FIGURE 2113.19 ILLUSTRATION OF EXCEPTION THREE CHIMNEY CLEARANCE PROVISION
SECTION 2114 DRY-STACK MASONRY
TABLE 2114.4 GROSS CROSS-SECTIONAL AREA ALLOWABLE STRESS FOR DRY-STACK MASONRY
518 SECTION 2115 EMISSION STANDARDS
520 CHAPTER 22 STEEL
SECTION 2201 GENERAL
SECTION 2202 IDENTIFICATION OF STEEL FOR STRUCTURAL PURPOSES
SECTION 2203 PROTECTION OF STEEL FOR STRUCTURAL PURPOSES
SECTION 2204 CONNECTIONS
SECTION 2205 STRUCTURAL STEEL
521 SECTION 2206 COMPOSITE STRUCTURAL STEEL AND CONCRETE STRUCTURES
SECTION 2207 STEEL JOISTS
522 SECTION 2208 STEEL CABLE STRUCTURES
SECTION 2209 STEEL STORAGE RACKS
SECTION 2210 COLD-FORMED STEEL
SECTION 2211 COLD-FORMED STEEL LIGHT-FRAME CONSTRUCTION
524 CHAPTER 23 WOOD
SECTION 2301 GENERAL
SECTION 2302 DESIGN REQUIREMENTS
SECTION 2303 MINIMUM STANDARDS AND QUALITY
528 SECTION 2304 GENERAL CONSTRUCTION REQUIREMENTS
529 TABLE 2304.6.1 MAXIMUM ALLOWABLE STRESS DESIGN WIND SPEED, Vasd PERMITTED FOR WOOD STRUCTURAL PANEL WALL SHEATHING USED TO RESIST WIND PRESSURES
TABLE 2304.8(1) ALLOWABLE SPANS FOR LUMBER FLOOR AND ROOF SHEATHING
530 TABLE 2304.8(2) SHEATHING LUMBER, MINIMUM GRADE REQUIREMENTS: BOARD GRADE
531 TABLE 2304.8(3) ALLOWABLE SPANS AND LOADS FOR WOOD STRUCTURAL PANEL SHEATHING AND SINGLE-FLOOR GRADES CONTINUOUS OVER TWO OR MORE SPANS WITH STRENGTH AXIS PERPENDICULAR TO SUPPORTSa
TABLE 2304.8(4) ALLOWABLE SPAN FOR WOOD STRUCTURAL PANEL COMBINATION SUBFLOOR-UNDERLAYMENT (SINGLE FLOOR) (Panels Continuous Over Two or More Spans and Strength Axis Perpendicular to Supports)
532 TABLE 2304.8(5) ALLOWABLE LOAD (PSF) FOR WOOD STRUCTURAL PANEL ROOF SHEATHING CONTINUOUS OVER TWO OR MORE SPANS AND STRENGTH AXIS PARALLEL TO SUPPORTS (Plywood structural panels are five-ply, five-layer unless otherwise noted)a
TABLE 2304.9.3.2 FASTENING SCHEDULE FOR MECHANICALLY LAMINATED DECKING USING LAMINATIONS OF 2-INCH NOMINAL THICKNESS
534 TABLE 2304.10.1 FASTENING SCHEDULE
535 TABLE 2304.10.1—continued FASTENING SCHEDULE
536 TABLE 2304.10.1—continued FASTENING SCHEDULE
537 TABLE 2304.10.1—continued FASTENING SCHEDULE
538 TABLE 2304.10.1—continued FASTENING SCHEDULE
539 TABLE 2304.11 MINIMUM DIMENSIONS OF HEAVY TIMBER STRUCTURAL MEMBERS
541 SECTION 2305 GENERAL DESIGN REQUIREMENTS FOR LATERAL FORCE-RESISTING SYSTEMS
EQUATION 23-1
TABLE 2305.2(1) en VALUES (inches) FOR USE IN CALCULATING DIAPHRAGM AND SHEAR WALL DEFLECTION DUE TO FASTENER SLIP (Structural I)a, c
542 EQUATION 23-2
TABLE 2305.2(2) VALUES OF Gt FOR USE IN CALCULATING DEFLECTION OF WOOD STRUCTURAL PANEL SHEAR WALLS AND DIAPHRAGMS
543 SECTION 2306 ALLOWABLE STRESS DESIGN
TABLE 2306.1.4 ALLOWABLE LOADS FOR LUMBER DECKING
544 SECTION 2307 LOAD AND RESISTANCE FACTOR DESIGN
SECTION 2308 CONVENTIONAL LIGHT-FRAME CONST
TABLE 2308.2.1 ALLOWABLE STORY HEIGHT
545 TABLE 2306.2(1) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL DIAPHRAGMS UTILIZING STAPLES WITH FRAMING OF DOUGLAS FIR-LARCH, OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADING
546 TABLE 2306.2(2) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL BLOCKED DIAPHRAGMS UTILIZING MULTIPLE ROWS OF STAPLES (HIGH-LOAD DIAPHRAGMS) WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADINGb
547 TABLE 2306.2(2)—continued ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL BLOCKED DIAPHRAGMS UTILIZING MULTIPLE ROWS OF STAPLES (HIGH-LOAD DIAPHRAGMS) WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINE FOR WIND OR SEISMIC LOADING
548 TABLE 2306.3(1) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL SHEAR WALLS UTILIZING STAPLES WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADING
TABLE 2306.3(2) ALLOWABLE SHEAR VALUES (plf) FOR WIND OR SEISMIC LOADING ON SHEAR WALLS OF FIBERBOARD SHEATHING BOARD CONSTRUCTION UTILIZING STAPLES FOR TYPE V CONSTRUCTION ONLY
549 TABLE 2306.3(3) ALLOWABLE SHEAR VALUES FOR WIND OR SEISMIC FORCES FOR SHEAR WALLS OF LATH AND PLASTER OR GYPSUM BOARD WOOD FRAMED WALL ASSEMBLIES UTILIZING STAPLES
551 TABLE 2308.4.1.1(1) HEADER AND GIRDER SPANSa, b FOR EXTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch, hem-fir, Southern pine and spruce-pine-fir and required number of jack studs)
552 TABLE 2308.4.1.1(1)—continued HEADER AND GIRDER SPANSa, b FOR EXTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch, hem-fir, Southern pine and spruce-pine-fir and required number of jack studs)
553 TABLE 2308.4.1.1(2) HEADER AND GIRDER SPANSa, b FOR INTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch, hem-fir, Southern pine and spruce-pine-fir and required number of jack studs)
554 TABLE 2308.4.2.1(1) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential sleeping areas, live load = 30 psf, L/Δ = 360)
555 TABLE 2308.4.2.1(1)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential sleeping areas, live load = 30 psf, L/Δ = 360)
556 TABLE 2308.4.2.1(2) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential living areas, live load = 40 psf, L/Δ = 360)
557 TABLE 2308.4.2.1(2)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential living areas, live load = 40 psf, L/Δ = 360)
558 FIGURE 2308.4.4.1(1) OPENINGS IN FLOOR AND ROOF DIAPHRAGMS
559 FIGURE 2308.4.4.1(2) OPENING LIMITATIONS FOR FLOOR AND ROOF DIAPHRAGMS
FIGURE 2308.4.4.2 PORTIONS OF FLOOR LEVEL OFFSET VERTICALLY
TABLE 2308.5.1 SIZE, HEIGHT AND SPACING OF WOOD STUDSc
561 FIGURE 2308.5.5.1(1) SINGLE-MEMBER HEADER IN EXTERIOR BEARING WALL
FIGURE 2308.5.5.1(2) ALTERNATIVE SINGLE-MEMBER HEADER WITHOUT CRIPPLE
562 TABLE 2308.5.11 MINIMUM THICKNESS OF WALL SHEATHING
563 FIGURE 2308.6.1 BASIC COMPONENTS OF THE LATERAL BRACING SYSTEM
564 TABLE 2308.6.1a WALL BRACING REQUIREMENTS
565 TABLE 2308.6.3(1) BRACING METHODS
566 TABLE 2308.6.3(1)—continued BRACING METHODS
TABLE 2308.6.3(2) EXPOSED PLYWOOD PANEL SIDING
567 TABLE 2308.6.3(3) WOOD STRUCTURAL PANEL WALL SHEATHINGb (Not exposed to the weather, strength axis parallel or perpendicular to studs except as Indicated)
TABLE 2308.6.3(4) ALLOWABLE SPANS FOR PARTICLE BOARD WALL SHEATHING (Not exposed to the weather, long dimension of the panel parallel or perpendicular to studs)
TABLE 2308.6.3(5) HARDBOARD SIDING
568 FIGURE 2308.6.5.1 ALTERNATE BRACED WALL PANEL (ABW)
FIGURE 2308.6.5.2 PORTAL FRAME WITH HOLD-DOWNS (PFH)
570 FIGURE 2308.6.7.2(1) BRACED WALL LINE TOP PLATE CONNECTION
FIGURE 2308.6.7.2(2) BRACED WALL PANEL TOP PLATE CONNECTION
572 FIGURE 2308.6.8.2(1) ROOF IN SDC D OR E NOT SUPPORTED ON ALL EDGES
FIGURE 2308.6.8.2(2) ROOF EXTENSION IN SDC D OR E BEYOND BRACED WALL LINE
573 FIGURE 2308.6.8.3 STEPPED FOOTING CONNECTION DETAILS
574 TABLE 2308.7.5 REQUIRED RATING OF APPROVED UPLIFT CONNECTORS (pounds)
576 TABLE 2308.7.1(1) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics without storage, live load = 10 psf, L/Δ = 240)
577 TABLE 2308.7.1(1)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics without storage, live load = 10 psf, L/Δ = 240)
578 TABLE 2308.7.1(2) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics with limited storage, live load = 20 psf, L/Δ = 240)
579 TABLE 2308.7.1(2)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics with limited storage, live load = 20 psf, L/Δ = 240)
580 TABLE 2308.7.2(1) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load = 20 psf, ceiling not attached to rafters, L/Δ = 180)
581 TABLE 2308.7.2(1)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load = 20 psf, ceiling not attached to rafters, L/Δ = 180)
582 TABLE 2308.7.2(2) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load = 20 psf, ceiling attached to rafters, L/Δ = 240)
583 TABLE 2308.7.2(2)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load = 20 psf, ceiling attached to rafters, L/Δ = 240)
584 TABLE 2308.7.2(3) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 30 psf, ceiling not attached to rafters, L/Δ = 180)
585 TABLE 2308.7.2(3)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 30 psf, ceiling not attached to rafters, L/Δ = 180)
586 TABLE 2308.7.2(4) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 50 psf, ceiling not attached to rafters, L/Δ = 180)
587 TABLE 2308.7.2(4) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 50 psf, ceiling not attached to rafters, L/Δ = 180)
588 TABLE 2308.7.2(5) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 30 psf, ceiling attached to rafters, L/Δ = 240)
589 TABLE 2308.7.2(5)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 30 psf, ceiling attached to rafters, L/Δ = 240)
590 TABLE 2308.7.2(6) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 50 psf, ceiling attached to rafters, L/Δ = 240)
591 TABLE 2308.7.2(6)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 50 psf, ceiling attached to rafters, L/Δ = 240)
592 TABLE 2308.7.3.1 RAFTER TIE CONNECTIONS
593 TABLE 2308.7.12 ALLOWABLE SPANS FOR 2-INCH TONGUE-AND-GROOVE DECKING
SECTION 2309 WOOD FRAME CONSTRUCTION MANUAL
594 TABLE 2308.7.12—continued ALLOWABLE SPANS FOR 2-INCH TONGUE-AND-GROOVE DECKING
596 CHAPTER 24 GLASS AND GLAZING
SECTION 2401 GENERAL
SECTION 2402 GLAZING REPLACEMENT
SECTION 2403 GENERAL REQUIREMENTS FOR GLASS
SECTION 2404 WIND, SNOW, SEISMIC AND DEAD LOADS ON GLASS
597 EQUATION 24-1
EQUATION 24-2
EQUATION 24-3
EQUATION 24-4
EQUATION 24-5
EQUATION 24-6
EQUATION 24-7
EQUATION 24-8
EQUATION 24-9
EQUATION 24-10
EQUATION 24-11
598 EQUATION 24-12
SECTION 2405 SLOPED GLAZING AND SKYLIGHTS
599 EQUATION 24-13
EQUATION 24-14
EQUATION 24-15
SECTION 2406 SAFETY GLAZING
600 TABLE 2406.2(1) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING CPSC 16 CFR PART 1201
TABLE 2406.2(2) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING ANSI Z97.1
601 SECTION 2407 GLASS IN HANDRAILS AND GUARDS
SECTION 2408 GLAZING IN ATHLETIC FACILITIES
602 SECTION 2409 GLASS IN WALKWAYS, ELEVATOR HOISTWAYS AND ELEVATOR CARS
604 CHAPTER 25 GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER
SECTION 2501 GENERAL
SECTION 2502 PERFORMANCE
SECTION 2503 INSPECTION
SECTION 2504 VERTICAL AND HORIZONTAL ASSEMBLIES
SECTION 2505 SHEAR WALL CONSTRUCTION
SECTION 2506 GYPSUM BOARD AND GYPSUM PANEL PRODUCT MATERIALS
605 TABLE 2506.2 GYPSUM BOARD AND GYPSUM PANEL PRODUCTS MATERIALS AND ACCESSORIES
SECTION 2507 LATHING AND PLASTERING
TABLE 2507.2 LATH, PLASTERING MATERIALS AND ACCESSORIES
606 SECTION 2508 GYPSUM CONSTRUCTION
TABLE 2508.1 INSTALLATION OF GYPSUM CONSTRUCTION
SECTION 2509 SHOWERS AND WATER CLOSETS
607 TABLE 2508.6 SHEAR CAPACITY FOR HORIZONTAL WOOD-FRAME GYPSUM BOARD DIAPHRAGM CEILING ASSEMBLIES
TABLE 2509.2 BACKERBOARD MATERIALS
SECTION 2510 LATHING AND FURRING FOR CEMENT PLASTER (STUCCO)
608 SECTION 2511 INTERIOR PLASTER
TABLE 2511.1.1 INSTALLATION OF PLASTER CONSTRUCTION
SECTION 2512 EXTERIOR PLASTER
609 TABLE 2512.6 CEMENT PLASTERS
SECTION 2513 EXPOSED AGGREGATE PLASTER
SECTION 2514 REINFORCED GYPSUM CONCRETE
610 CHAPTER 26 PLASTIC
SECTION 2601 GENERAL
SECTION 2602 FINISH AND TRIM
SECTION 2603 FOAM PLASTIC INSULATION
613 FIGURE 2603.8 TERMITE INFESTATION PROBABILITY MAP
615 TABLE 2603.12.1 CLADDING MINIMUM FASTENING REQUIREMENTS FOR DIRECT ATTACHMENT OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHT
TABLE 2603.12.2 FURRING MINIMUM FASTENING REQUIREMENTS FOR APPLICATION OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHTa
616 TABLE 2603.13.1 CLADDING MINIMUM FASTENING REQUIREMENTS FOR DIRECT ATTACHMENT OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHT
SECTION 2604 INTERIOR FINISH AND TRIM
SECTION 2605 PLASTIC VENEER
617 TABLE 2603.13.2 FURRING MINIMUM FASTENING REQUIREMENTS FOR APPLICATION OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHT
SECTION 2606 LIGHT-TRANSMITTING PLASTICS
618 SECTION 2607 LIGHT-TRANSMITTING PLASTIC WALL PANELS
619 TABLE 2607.4 AREA LIMITATION AND SEPARATION REQUIREMENTS FOR LIGHT-TRANSMITTING PLASTIC WALL PANELS
SECTION 2608 LIGHT-TRANSMITTING PLASTIC GLAZING
SECTION 2609 LIGHT-TRANSMITTING PLASTIC ROOF PANELS
620 TABLE 2609.4 AREA LIMITATIONS FOR LIGHT-TRANSMITTING PLASTIC ROOF PANELS
SECTION 2610 LIGHT-TRANSMITTING PLASTIC SKYLIGHT GLAZING
621 SECTION 2611 LIGHT-TRANSMITTING PLASTIC INTERIOR SIGNS
SECTION 2612 PLASTIC COMPOSITES
SECTION 2613 FIBER-REINFORCED POLYMER
622 SECTION 2614 REFLECTIVE PLASTIC CORE INSULATION
624 CHAPTER 27 ELECTRICAL
SECTION 2701 GENERAL
SECTION 2702 EMERGENCY AND STANDBY POWER SYSTEMS
626 CHAPTER 28 MECHANICAL SYSTEMS
SECTION 2801 GENERAL
628 CHAPTER 29 PLUMBING SYSTEMS
SECTION 2901 GENERAL
SECTION 2902 MINIMUM PLUMBING FACILITIES
[P] TABLE 2902.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 2902.2 and 2902.3)
629 [P] TABLE 2902.1—continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 2902.2 and 2902.3)
632 CHAPTER 30 ELEVATORS AND CONVEYING SYSTEMS
SECTION 3001 GENERAL
TABLE 3001.3 ELEVATORS AND CONVEYING SYSTEMS AND COMPONENTS
SECTION 3002 HOISTWAY ENCLOSURES
633 SECTION 3003 EMERGENCY OPERATIONS
SECTION 3004 CONVEYING SYSTEMS
634 SECTION 3005 MACHINE ROOMS
SECTION 3006 ELEVATOR LOBBIES AND HOISTWAY OPENING PROTECTION
635 SECTION 3007 FIRE SERVICE ACCESS ELEVATOR
636 FIGURE 3007.6.5 FIRE SERVICE ACCESS ELEVATOR SYMBOL
637 SECTION 3008 OCCUPANT EVACUATION ELEVATORS
639 SECTION 3009 HOISTWAY VENTING
640 CHAPTER 31 SPECIAL CONSTRUCTION
SECTION 3101 GENERAL
SECTION 3102 MEMBRANE STRUCTURES
641 SECTION 3103 TEMPORARY STRUCTURES
SECTION 3104 PEDESTRIAN WALKWAYS AND TUNNELS
643 SECTION 3105 AWNINGS AND CANOPIES
SECTION 3106 MARQUEES
SECTION 3107 SIGNS
SECTION 3108 TELECOMMUNICATION AND BROADCAST TOWERS
644 SECTION 3109 SWIMMING POOLS, SPAS AND HOT TUBS
SECTION 3110 AUTOMATIC VEHICULAR GATES
SECTION 3111 SOLAR ENERGY SYSTEMS
SECTION 3112 GREENHOUSES
645 SECTION 3113 RELOCATABLE BUILDINGS
SECTION 3114 FIXED GUIDEWAY TRANSIT AND PASSENGER RAIL SYSTEMS
646 CHAPTER 32 ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
SECTION 3201 GENERAL
SECTION 3202 ENCROACHMENTS
648 CHAPTER 33 SAFEGUARDS DURING CONSTRUCTION
SECTION 3301 GENERAL
SECTION 3302 CONSTRUCTION SAFEGUARDS
SECTION 3303 DEMOLITION
SECTION 3304 SITE WORK
649 SECTION 3305 SANITARY
SECTION 3306 PROTECTION OF PEDESTRIANS
TABLE 3306.1 PROTECTION OF PEDESTRIANS
650 SECTION 3307 PROTECTION OF ADJOINING PROPERTY
SECTION 3308 TEMPORARY USE OF STREETS, ALLEYS AND PUBLIC PROPERTY
SECTION 3309 FIRE EXTINGUISHERS
651 SECTION 3310 MEANS OF EGRESS
SECTION 3311 STANDPIPES
SECTION 3312 AUTOMATIC SPRINKLER SYSTEM
SECTION 3313 WATER SUPPLY FOR FIRE PROTECTION
SECTION 3314 FIRE WATCH DURING CONSTRUCTON
652 CHAPTER 34 RESERVED
654 CHAPTER 35 REFERENCED STANDARDS
AA
AAMA
ACI
AISC
655 AISI
ALI
AMCA
ANSI
656 APA
657 ASABE
ASCE/SEI
658 ASME
ASSE
ASTM
669 AWC
AWCI
670 AWPA
AWS
BHMA
CEN
CPA
671 CPSC
CSA
CSSB
DASMA
672 DOC
DOL
DOTn
FEMA
FM
673 GA
HPVA
ICC
674 ISO
675 MHI
NAAMM
NCMA
NFPA
678 PCI
PTI
RMI
SBCA
SDI
SJI
679 SPRI
SRCC
TIA
TMS
TPI
680 UL
682 ULC
USC
WCLIB
WDMA
WRI
684 APPENDIX A EMPLOYEE QUALIFICATIONS
SECTION A101 BUILDING OFFICIAL QUALIFICATIONS
[A] SECTION A102 REFERENCED STANDARDS
686 APPENDIX B BOARD OF APPEALS
SECTION B101 GENERAL
688 APPENDIX C GROUP U—AGRICULTURAL BUILDINGS
SECTION C101 GENERAL
SECTION C102 ALLOWABLE HEIGHT AND AREA
TABLE C102.1 BASIC ALLOWABLE AREA FOR A GROUP U, ONE STORY IN HEIGHT AND MAXIMUM HEIGHT OF SUCH OCCUPANCY
SECTION C103 MIXED OCCUPANCIES
SECTION C104 EXITS
690 APPENDIX D FIRE DISTRICTS
SECTION D101 GENERAL
SECTION D102 BUILDING RESTRICTIONS
691 SECTION D103 CHANGES TO BUILDINGS
SECTION D104 BUILDINGS LOCATED PARTIALLY IN THE FIRE DISTRICT
SECTION D105 EXCEPTIONS TO RESTRICTIONS IN FIRE DISTRICT
692 SECTION D106 REFERENCED STANDARDS
694 APPENDIX E SUPPLEMENTARY ACCESSIBILITY REQUIREMENTS
SECTION E101 GENERAL
SECTION E102 DEFINITIONS
SECTION E103 ACCESSIBLE ROUTE
SECTION E104 SPECIAL OCCUPANCIES
695 TABLE E104.2.1 DWELLING OR SLEEPING UNITS WITH ACCESSIBLE COMMUNICATION FEATURES
SECTION E105 OTHER FEATURES AND FACILITIES
SECTION E106 TELEPHONES
TABLE E106.2 WHEELCHAIR-ACCESSIBLE TELEPHONES
696 SECTION E107 SIGNAGE
SECTION E108 BUS STOPS
697 SECTION E109 TRANSPORTATION FACILITIES AND STATIONS
698 SECTION E110 AIRPORTS
SECTION E111 REFERENCED STANDARDS
700 APPENDIX F RODENTPROOFING
SECTION F101 GENERAL
702 APPENDIX G FLOOD-RESISTANT CONSTRUCTION
SECTION G101 ADMINISTRATION
SECTION G102 APPLICABILITY
SECTION G103 POWERS AND DUTIES
703 SECTION G104 PERMITS
704 SECTION G105 VARIANCES
705 SECTION G201 DEFINITIONS
SECTION G301 SUBDIVISIONS
SECTION G401 SITE IMPROVEMENT
706 SECTION G501 MANUFACTURED HOMES
SECTION G601 RECREATIONAL VEHICLES
SECTION G701 TANKS
SECTION G801 OTHER BUILDING WORK
707 SECTION G901 TEMPORARY STRUCTURES AND TEMPORARY STORAGE
SECTION G1001 UTILITY AND MISCELLANEOUS GROUP U
SECTION G1101 REFERENCED STANDARDS
708 APPENDIX H SIGNS
SECTION H101 GENERAL
SECTION H102 DEFINITIONS
SECTION H103 LOCATION
709 SECTION H104 IDENTIFICATION
SECTION H105 DESIGN AND CONSTRUCTION
SECTION H106 ELECTRICAL
SECTION H107 COMBUSTIBLE MATERIALS
SECTION H108 ANIMATED DEVICES
710 SECTION H109 GROUND SIGNS
SECTION H110 ROOF SIGNS
SECTION H111 WALL SIGNS
SECTION H112 PROJECTING SIGNS
711 SECTION H113 MARQUEE SIGNS
SECTION H114 PORTABLE SIGNS
TABLE 4-A SIZE, THICKNESS AND TYPE OF GLASS PANELS IN SIGNS
TABLE 4-B THICKNESS OF PROJECTION SIGN
SECTION H115 REFERENCED STANDARDS
712 APPENDIX I PATIO COVERS
SECTION I101 GENERAL
SECTION I102 DEFINITION
SECTION I103 EXTERIOR WALLS AND OPENINGS
SECTION I104 HEIGHT
SECTION I105 STRUCTURAL PROVISIONS
714 APPENDIX J GRADING
SECTION J101 GENERAL
SECTION J102 DEFINITIONS
SECTION J103 PERMITS REQUIRED
715 SECTION J104 PERMIT APPLICATION AND SUBMITTALS
SECTION J105 INSPECTIONS
SECTION J106 EXCAVATIONS
SECTION J107 FILLS
SECTION J108 SETBACKS
716 FIGURE J107.3 BENCHING DETAILS
FIGURE J108.1 DRAINAGE DIMENSIONS
717 SECTION J109 DRAINAGE AND TERRACING
SECTION J110 EROSION CONTROL
SECTION J111 REFERENCED STANDARDS
718 APPENDIX K ADMINISTRATIVE PROVISIONS
SECTION K101 GENERAL
SECTION K102 APPLICABILITY
SECTION K103 PERMITS
719 SECTION K104 CONSTRUCTION DOCUMENTS
SECTION K105 ALTERNATIVE ENGINEERED DESIGN
SECTION K106 REQUIRED INSPECTIONS
SECTION K107 PREFABRICATED CONSTRUCTION
720 SECTION K108 TESTING
SECTION K109 RECONNECTION
SECTION K110 CONDEMNING ELECTRICAL SYSTEMS
SECTION K111 ELECTRICAL PROVISIONS
722 APPENDIX L EARTHQUAKE RECORDING INSTRUMENTATION
SECTION L101 GENERAL
724 APPENDIX M TSUNAMI-GENERATED FLOOD HAZARD
SECTION M101 REFUGE STRUCTURES FOR VERTICAL EVACUATION FROM TSUNAMI-GENERATED FLOOD HAZARD
SECTION M102 REFERENCED STANDARDS
726 APPENDIX N REPLICABLE BUILDINGS
SECTION N101 ADMINISTRATION
SECTION N102 DEFINITIONS
SECTION N103 REPLICABLE DESIGN REQUIREMENTS
SECTION N104 REPLICABLE DESIGN SUBMITTAL REQUIREMENTS
727 SECTION N105 REVIEW AND APPROVAL OF REPLICABLE DESIGN
SECTION N106 SITE-SPECIFIC APPLICATION OF APPROVED REPLICABLE DESIGN
SECTION N107 SITE-SPECIFIC REVIEW AND APPROVAL OF REPLICABLE DESIGN
728 INDEX
768 HELPFUL TOOLS FOR YOUR BUILDING CODE
769 S.K. GHOSH ASSOCIATES LLC
770 ICC EVALUATION SERVICE
771 ICC’S DIGITAL CODES LIBRARY
WA StateBuildingCode 1stptg 2018.pdf
$69.17