13.230 – Explosion protection – PDF Standards Store ?u= Wed, 06 Nov 2024 02:43:56 +0000 en-US hourly 1 https://wordpress.org/?v=6.7.1 ?u=/wp-content/uploads/2024/11/cropped-icon-150x150.png 13.230 – Explosion protection – PDF Standards Store ?u= 32 32 JIS M 7615:1987 ?u=/product/publishers/jis/jis-m-76151987/ Wed, 06 Nov 2024 02:43:56 +0000 Non Sparking Beryllium Copper Alloy Tools
Published By Publication Date Number of Pages
JIS 1987-11-01 30
]]>
Non Sparking Beryllium Copper Alloy Tools
Published By Publication Date Number of Pages
JIS 1987-11-01 30
]]>
ISO 6184-4:1985 ?u=/product/publishers/iso/iso-6184-41985/ Tue, 05 Nov 2024 23:38:58 +0000 Explosion protection systems — Part 4: Determination of efficacy of explosion suppression systems
Published By Publication Date Number of Pages
ISO 1985-11 6
]]>
Gives a method for evaluating the effectiveness against defined explosions in an enclosed volume. Gives the criteria for alternative test apparatus used to undertake tests and criteria to be applied in defining the safe operating regime.

]]>
ISO 6184-3:1985 ?u=/product/publishers/iso/iso-6184-31985/ Tue, 05 Nov 2024 23:38:57 +0000 Explosion protection systems — Part 3: Determination of explosion indices of fuel/air mixtures other than dust/air and gas/air mixtures
Published By Publication Date Number of Pages
ISO 1985-11 6
]]>
Specifies a test method. Gives the criteria by which results obtained using other test procedures can be correlated to yield the quantities as determined by the method specified.

]]>
ISO 6184-2:1985 ?u=/product/publishers/iso/iso-6184-21985/ Tue, 05 Nov 2024 23:38:56 +0000 Systèmes de protection contre les explosions — Partie 2: Détermination des indices d'explosion des gaz combustibles dans l'air
Published By Publication Date Number of Pages
ISO 1985-11 8
]]>
La présente partie de l'ISO 6184 spécifie des méthodes d'essai pour la détermination des indices d'explosion des gaz combustibles dans l'air, à l'intérieur d'un volume clos. Elle donne des critères permettant de juger la corrélation entre les résultats obtenus à partir d'autres méthodes d'essai et les indices tels que déterminés par la méthode spécifiée dans la présente partie de l'ISO 6184.

La présente partie de l'ISO 6184 s'applique à la détermination des indices d'explosion de gaz ayant rapport à des explosions confinées après inflammation des réactifs. Elle ne traite pas des indices relatifs aux conditions d'inflammation des réactifs. Dans le cas où les méthodes spécifiées dans la présente partie de l'ISO 6184 ne conduiraient pas à une inflammation du mélange de gaz dans l'air, on ne doit pas en conclure que le gaz en question n'est pas susceptible d'exploser. L'interprétation de tels cas doit être laissée aux spécialistes des explosions et de la protection contre les explosions.

]]>
ISO 6184-1:1985 ?u=/product/publishers/iso/iso-6184-11985/ Tue, 05 Nov 2024 23:38:55 +0000 Systèmes de protection contre les explosions — Partie 1: Détermination des indices d'explosion des poussières combustibles dans l'air
Published By Publication Date Number of Pages
ISO 1985-11 8
]]>
La présente partie de l'ISO 6184 spécifie une méthode d'essai pour la détermination des indices d'explosion des poussières combustibles en suspension dans l'air, à l'intérieur d'un volume clos. Elle donne des critères permettant de juger la corrélation entre les résultats obtenus à partir d'autres méthodes d'essai et les indices tels que déterminés par la méthode spécifiée dans la présente partie de l'ISO 6184.

La présente partie de l'ISO 6184 s'applique à la détermination des indices d'explosion de poussières ayant rapport à des explosions confinées après inflammation des réactifs. Elle ne traite pas des indices relatifs aux conditions d'inflammation des réactifs. Dans le cas où la méthode spécifiée dans la présente partie de l'ISO 6184 ne conduirait pas à une inflammation de la poussière dans l'air, on ne doit pas en conclure que la poussière en question n'est pas susceptible d'exploser. L'interprétation de tels cas doit être laissée aux spécialistes des explosions et de la protection contre les explosions.

]]>
VDI 2263 Part 8.2:2014 Edition ?u=/product/publishers/din/vdi-2263-part-8-2/ Tue, 05 Nov 2024 17:51:10 +0000 Dust fires and dust explosions - Hazards - assessment - protective measures - Explosion suppression and combination of structural protective measures in elevators
Published By Publication Date Number of Pages
DIN 2014-12 14
]]>
The standard specifies protective measures adopted to prevent explosions in elevators in which combustible dust/air mixtures are found or can develop when operated in the intended manner. The standard is intended for manufacturers as well as operators of elevators.

]]>
VDI 2263 Part 8.1:2011 Edition ?u=/product/publishers/din/vdi-2263-part-8-1/ Tue, 05 Nov 2024 17:51:06 +0000 Dust fires and dust explosions - Hazards - assessment - protective measures - Fire and explosion protection on elevators - Examples
Published By Publication Date Number of Pages
DIN 2011-03 38
]]>
This guideline is applied to measures adopted to prevent explosions in elevators in which combustible dust/air mixtures, steam/air mixtures or hybrid mixtures are found or can develop when operated in the intended manner. It provides information for manufacturers as well as special information for operators in the form of examples for conducting risk analyses and implementing preventive measures. The guideline requires a familiarity with the guideline VDI 2263 Part 8.

]]>
VDI 2263 Part 8:2008 Edition ?u=/product/publishers/din/vdi-2263-part-8/ Tue, 05 Nov 2024 17:51:06 +0000 Dust fires and dust explosions - Hazards - Assessment - Protective measures - Fire and explosion protection on elevators
Published By Publication Date Number of Pages
DIN 2008-12 35
]]>
For the purpose of this guideline, elevators are vertical conveyors of various designs for transportting bulk materials between different levels. This VDI guideline aims to take into account both the manufacturer's and the user's tasks. Precautions against fires and explosions shall be considered in the early design stage of an installation.

]]>
VDI 2263 Part 6.1:2017 Edition ?u=/product/publishers/din/vdi-2263-part-6-1/ Tue, 05 Nov 2024 17:51:06 +0000 Dust fires and dust explosions - Hazards - assessment - protective measures - Dust fires and explosion protection in dust extracting installations - Examples
Published By Publication Date Number of Pages
DIN 2017-08 102
]]>
The standard is applied to measures for explosion protection in dust extraction installations where, during specified normal use, combustible dust/air mixtures, vapour/air mixtures or hybrid mixtures occur or may be formed. The standard offers practical guidance and approaches to protective measures complementing the standard VDI 2263 Part 6. The standard applies in conjunction with VDI 2263 Part 6.

]]>
VDI 2263 Part 7.1:2013 Edition ?u=/product/publishers/din/vdi-2263-part-7-1/ Tue, 05 Nov 2024 17:51:06 +0000 Dust fires and dust explosions - Hazards - assessment - protective measures - Fire and explosion protection in spraying and drying integrated equipment - Examples
Published By Publication Date Number of Pages
DIN 2013-03 88
]]>
The guideline gives practical advice and possible solutions for the protection against fire and explosions in spray dryers. It describes the state of the art regarding the level of development of advanced processes, facilities or modes of operation that asures the practical suitability of a measure to protect the health and safety of employees. The guideline applies to measures for explosion protection in spray dryers, where flammable dust/air mixtures, steam/air mixtures or hybrid mixtures are present of may develop at normal use. This guideline gives both manufacturers and operators information for carrying out risk assessments and protective measures in the form of examples. The guideline requires the knowledge of the guideline VDI 2263 Part 7.

]]>