29.130.99 – Other switchgear and controlgear – PDF Standards Store ?u= Tue, 05 Nov 2024 20:03:12 +0000 en-US hourly 1 https://wordpress.org/?v=6.7.1 ?u=/wp-content/uploads/2024/11/cropped-icon-150x150.png 29.130.99 – Other switchgear and controlgear – PDF Standards Store ?u= 32 32 IEC TR 61800-6:2003 ?u=/product/publishers/iec/iec-tr-61800-62003/ Tue, 05 Nov 2024 20:03:12 +0000 Adjustable speed electrical power drive systems - Part 6: Guide for determination of types of load duty and corresponding current ratings
Published By Publication Date Number of Pages
IEC 2003-03-31 40
]]>
provides alternative methods for specifying ratings for adjustable speed electrical power drive systems (PDS) and in particular their basic drive modules (BDM

]]>
IEC 62271-4:2022 ?u=/product/publishers/iec/iec-62271-42022/ Tue, 05 Nov 2024 19:42:47 +0000 Appareillage à haute tension - Partie 4: Procédures de manipulation des gaz pour l'isolation et/ou la commutation
Published By Publication Date Number of Pages
IEC 2022-07-22 504
]]>
L'IEC 62271-4:2022 s'applique aux procédures de manipulation des gaz pour l'isolation et/ou la commutation lors de l’installation, de la mise en service, de la réparation, de la révision, du fonctionnement normal ou anormal et de l'élimination en fin de cycle de vie de l'appareillage électrique.
Ces procédures sont considérées comme des exigences minimales pour garantir la fiabilité de l'appareillage électrique, la sécurité du personnel qui travaille avec ces gaz et pour réduire le plus possible l'impact sur l'environnement. Des exigences supplémentaires peuvent être formulées dans le manuel d'instructions d'exploitation du fabricant.
Cette seconde édition annule et remplace la première édition de l'IEC 62271-4 parue en 2013. Cette édition constitue une révision technique.
Cette édition inclut les modifications techniques majeures suivantes par rapport à l'édition précédente:

  1. l'intitulé a été modifié;
  2. les procédures de manipulation des alternatives au SF6, utilisés pour l'isolation et/ou la commutation, sont ajoutées;
  3. les principaux articles sont indépendants du type de gaz;
  4. pour chaque gaz, une annexe distincte présente les informations spécifiques au gaz, les procédures de manipulation, les mesures de sécurité, etc.;
  5. les informations relatives au SF6 (ancienne Annexe E) et aux effets sur l'environnement du SF6 et de ses mélanges (ancienne Annexe F) ont été déplacées vers l'IEC 60376;
  6. les informations relatives aux produits de décomposition du SF6 et de ses mélanges (ancienne Annexe G), la procédure d'évaluation des effets potentiels sur la santé des produits de décomposition du SF6 et de ses mélanges (ancienne Annexe H) et la régénération cryogénique du SF6 (ancienne Annexe I) ont été déplacées vers l'IEC 60480.
]]>
IEC 62271-4:2013 ?u=/product/publishers/iec/iec-62271-42013/ Tue, 05 Nov 2024 19:42:46 +0000 High-voltage switchgear and controlgear - Part 4: Handling procedures for sulphur hexafluoride (SF6) and its mixtures
Published By Publication Date Number of Pages
IEC 2013-08-26 162
]]>
IEC 62271-4:2013 applies to the procedures for handling of SF6 during installation, commissioning, normal and abnormal operations, disposal at the end of life of high voltage switchgear and controlgear. This first edition cancels and replaces the first edition of IEC/TR 62271-303 published in 2008. This first edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) the description of the potential effects on health of SF6 by products (former Annex D of IEC/TR 62271-303:2008) has been replaced by the calculation methods for evaluating of the potential effects on health of SF6 by products (see Annex H);
b) information about cryogenic reclaim of SF6. Have been added (see Annex I);
c) handling procedures for the most popular SF6 mixtures have been added (see Annex J).

]]>
IEC 62271-205:2008 ?u=/product/publishers/iec/iec-62271-2052008/ Tue, 05 Nov 2024 19:42:38 +0000 High-voltage switchgear and controlgear - Part 205: Compact switchgear assemblies for rated voltages above 52 kV
Published By Publication Date Number of Pages
IEC 2008-01-15 52
]]>
This part of IEC 62271 applies to compact switchgear assemblies consisting of at least one switching device directly connected to, or sharing components with, one or more other devices such that there is an interaction between the functions of the individual devices. Such assemblies are made up of devices defined in 1.101 and are designed, tested and supplied for use as a single unit. The interaction between devices may be due to proximity, sharing of components or a combination of both. The assemblies may contain components of air insulated switchgear (AIS) only or a combination of AIS and gas insulated switchgear (GIS), so called mixed technology switchgear (MTS) and may be delivered entirely prefabricated or partially assembled.

]]>
IEC 62271-1:2017 ?u=/product/publishers/iec/iec-62271-12017/ Tue, 05 Nov 2024 19:42:32 +0000 High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear
Published By Publication Date Number of Pages
IEC 2017-07-12 260
]]>
IEC 62271-1:2017 applies to AC switchgear and controlgear designed for indoor and/or outdoor installation and for operation at service frequencies up to and including 60 Hz and having rated voltages above 1 000 V.
This document applies to all high-voltage switchgear and controlgear except as otherwise specified in the relevant IEC standards for the particular type of switchgear and controlgear.
This second edition cancels and replaces the first edition published in 2007 and Amendment 1:2011. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
New numbering in accordance with ISO/IEC directives, Part 2 (2016) and IEEE Std. C37.100.1.
4.1.2 a) The normal service condition for indoor switchgear is limited to one range of 40 °C to -5 °C.
4.1.3 a) The normal service condition for outdoor switchgear is limited to one range of 40 °C to -25 °C.
4.2.2: The specifications from IEC 60071-2:1996 are adopted for altitude correction factors above 1 000 m.
5.2.2: Range I, the rated voltage of 40,5 kV is added Series I Table 1; Table 2 and Table 4 are updated on recommendation of the US National Committee.
6.8: New subclause added for manual operated actuators consistent with “Man Machine Interface” recommendations of IEC 60447 .
7.2.6.1:Insert the wording regarding preliminary impulses across open vacuum interrupters according to the result of IEC 17/1026/RQ.
7.3: Changed the requirement for radio interference voltage to a rated voltage level of 245 kV and above, instead of 123 kV and above. This change is based on reported positive test and service experience of utility representatives in the maintenance team of this standard.
7.5.6, Table 14:
a. Introduced the distinction of parts in “OG” (oxidizing gas) or in “NOG” (not oxidizing gas) replacing the former “air” and “SF6”;
b. Increased the allowable temperature rise for some parts in groups 1 and 2 of Table 14 according to IEC TR 60943;
c. Expanded the definition of allowable temperature rise for categories of accessible surfaces with reference to IEC Guide 117. See also Point 15 in 7.5.6.2.
7.5.6.2: Point 5 is modified to clarify the introduction of “OG” and “NOG” gas.
7.10: Some tests were removed because the relevant test standards of IEC 60068 series were modified or withdrawn.
7.11.3: The acceptance criteria for X-radiation testing are modified to recognize higher rated vacuum interrupters.
Former informative Annex H: Corrosion is deleted, the content is part of
IEC TR 62271-306.
New Annex J (informative): Added informative guidelines for the extension of validity of type tests
New Annex K (informative): Added informative guidelines about exposure to pollution
The contents of the Interpretation Sheet 1 of May 2021 have been included in this copy.

]]>
IEC 62271-112:2021 ?u=/product/publishers/iec/iec-62271-1122021/ Tue, 05 Nov 2024 19:42:30 +0000 High-voltage switchgear and controlgear - Part 112: Alternating current high-speed earthing switches for secondary arc extinction on transmission lines
Published By Publication Date Number of Pages
IEC 2021-07-13 58
]]>

IEC 62271-112:2021 applies to AC high-speed earthing switches (hereinafter termed HSES) designed for indoor and outdoor installation and for operation at service frequencies of 50 Hz and 60 Hz on systems having rated voltages of 550 kV and above. HSESs described in this document are intended to extinguish the secondary arc remaining after clearing faults on transmission lines by the circuit-breakers. For more detailed information on HSESs, refer to Annex A. This second edition cancels and replaces the first edition published in 2013. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: The document has been updated to the second edition of IEC 62271-1:2017.

]]>
IEC 62271-112:2013 ?u=/product/publishers/iec/iec-62271-1122013/ Tue, 05 Nov 2024 19:42:30 +0000 Appareillage à haute tension – Partie 112: Sectionneurs de terre rapides à courant alternatif pour l’extinction de l’arc secondaire sur les lignes de transport
Published By Publication Date Number of Pages
IEC 2013-08-06 56
]]>
Appareillage à haute tension – Partie 112: Sectionneurs de terre rapides à courant alternatif pour l’extinction de l’arc secondaire sur les lignes de transport
Published By Publication Date Number of Pages
IEC 2013-08-06 56
]]>
IEC 62271-104:2020 ?u=/product/publishers/iec/iec-62271-1042020/ Tue, 05 Nov 2024 19:42:21 +0000 Appareillage à haute tension - Partie 104: Interrupteurs à courant alternatif pour tensions assignées supérieures à 52 kV
Published By Publication Date Number of Pages
IEC 2020-08-21 112
]]>
Appareillage à haute tension - Partie 104: Interrupteurs à courant alternatif pour tensions assignées supérieures à 52 kV
Published By Publication Date Number of Pages
IEC 2020-08-21 112
]]>
IEC 62271-104:2015 ?u=/product/publishers/iec/iec-62271-1042015/ Tue, 05 Nov 2024 19:42:20 +0000 Appareillage à haute tension – Partie 104: Interrupteurs à courant alternatif pour tensions assignées supérieures à 52 kV
Published By Publication Date Number of Pages
IEC 2015-02-05 106
]]>
Appareillage à haute tension – Partie 104: Interrupteurs à courant alternatif pour tensions assignées supérieures à 52 kV
Published By Publication Date Number of Pages
IEC 2015-02-05 106
]]>
IEC 62271-104:2009 ?u=/product/publishers/iec/iec-62271-1042009/ Tue, 05 Nov 2024 19:42:18 +0000 High-voltage switchgear and controlgear - Part 104: Alternating current switches for rated voltages of 52 kV and above
Published By Publication Date Number of Pages
IEC 2009-04-20 104
]]>
IEC 62271-104:2009 applies to three-pole alternating current switches for rated voltages 52 kV and above, having making and breaking current ratings, for indoor and outdoor installations, and for rated frequencies up to and including 60 Hz. This standard is also applicable to the operating devices of these switches and to their auxiliary equipment. The main object of this standard is to establish requirements for switches used in transmission and distribution systems. General-purpose switches for this application are designed to comply with the following service applications:
– carrying rated normal current continuously;
– carrying short-circuit currents for a specified time;
– switching of mainly active loads;
– switching of no-load transformers;
– switching of the charging current of unloaded cables, overhead lines or busbars;
– switching of closed-loop circuits;
– making short-circuit currents.
A further object of this standard is to establish requirements for limited-purpose and special- purpose switches used in transmission and distribution systems. Limited-purpose switches shall comply with one or more of the service applications indicated above. Special-purpose switches may comply with one or more of the service applications indicated above and, in addition, shall be suitable for one or more of the following applications:
– switching single capacitor banks;
– switching back-to-back capacitor banks;
– switching shunt reactors including secondary or tertiary reactors switched from the primary side of the transformer;
– applications requiring an increased number of operating cycles;
– switching under earth fault conditions in non-effectively earthed neutral systems.
This standard cancels and replaces IEC 60265-2:1988. The major changes with respect to IEC 60265-2 are as follows:
– alignment with IEC 62271-1 and IEC 62271-100;
– requirements for capacitive current switching aligned with those in IEC 62271-100: classes C1 and C2 are introduced.

This publication is to be read in conjunction with IEC 62271-1:2007, IEC 62271-100:2008, IEC 62271-102:2001 and IEC 62271-110:2005.

]]>