91.060.99 – Other elements of buildings – PDF Standards Store ?u= Wed, 06 Nov 2024 01:40:41 +0000 en-US hourly 1 https://wordpress.org/?v=6.7.1 ?u=/wp-content/uploads/2024/11/cropped-icon-150x150.png 91.060.99 – Other elements of buildings – PDF Standards Store ?u= 32 32 JIS A 6601:1996 ?u=/product/publishers/jis/jis-a-66011996/ Wed, 06 Nov 2024 01:40:41 +0000 Metal Components for Balcony and Handrails of Dwellings
Published By Publication Date Number of Pages
JIS 1996-02-01 26
]]>
Metal Components for Balcony and Handrails of Dwellings
Published By Publication Date Number of Pages
JIS 1996-02-01 26
]]>
JIS A 5541:2008 ?u=/product/publishers/jis/jis-a-55412008/ Wed, 06 Nov 2024 01:39:50 +0000 Body of turnbuckle for building
Published By Publication Date Number of Pages
JIS 2008-10-20 13
]]>
Body of turnbuckle for building
Published By Publication Date Number of Pages
JIS 2008-10-20 13
]]>
JIS A 5540:2008 ?u=/product/publishers/jis/jis-a-55402008/ Wed, 06 Nov 2024 01:39:49 +0000 Turnbuckle for building
Published By Publication Date Number of Pages
JIS 2008-10-20 22
]]>
Turnbuckle for building
Published By Publication Date Number of Pages
JIS 2008-10-20 22
]]>
JIS A 1422:1982 ?u=/product/publishers/jis/jis-a-14221982/ Wed, 06 Nov 2024 01:37:05 +0000 Simplified Test Method for Determining Shading Coefficient of Shading Devices
Published By Publication Date Number of Pages
JIS 1982-09-01 14
]]>
Simplified Test Method for Determining Shading Coefficient of Shading Devices
Published By Publication Date Number of Pages
JIS 1982-09-01 14
]]>
ISO 6589:1983 ?u=/product/publishers/iso/iso-65891983/ Tue, 05 Nov 2024 23:44:46 +0000 Joints in building — Laboratory method of test for air permeability of joints
Published By Publication Date Number of Pages
ISO 1983-11 5
]]>
Specifies the test method to be used in laboratories for assessing the air permeability of non-opening joints between components in the exterior walls of buildings, whether the joints have been subjected to prior ageing or not. Does not apply to joints within components (for example the joint between glass fixed in a window frame and sealed with a glazing compound).

]]>
ISO 3447:1975 ?u=/product/publishers/iso/iso-34471975/ Tue, 05 Nov 2024 23:06:04 +0000 Joints in building — General check-list of joint functions
Published By Publication Date Number of Pages
ISO 1975-11 4
]]>
Forms one of a series concerning joints in building. The series includes the following International Standards: ISO 2444 – Joints in building – Vocabulary; ISO 2445 – Joints in building – Fundamental principles for design. Gives a general check-list of functions of joints in building for use in their design.

]]>
ISO 2445:1972 ?u=/product/publishers/iso/iso-24451972/ Tue, 05 Nov 2024 22:47:38 +0000 Joints dans le bâtiment — Principes de conception fondamentaux
Published By Publication Date Number of Pages
ISO 1972-10 4
]]>
Outlines some basic principles for the design of joints in building. These principles fall under three main headings of properties: geometrical, structural and environmental properties of joints.

]]>
ISO 2444:1988 ?u=/product/publishers/iso/iso-24441988/ Tue, 05 Nov 2024 22:47:35 +0000 Joints in building — Vocabulary
Published By Publication Date Number of Pages
ISO 1988-12 6
]]>
Defines terms used to describe building joints, their constituent parts and their design in building construction. Cancels and replaces the first edition (ISO 2444-1974), of which it constitutes a minor revision.

]]>
DIN EN 1364-6:2016 Edition ?u=/product/publishers/din/din-en-1364-6/ Tue, 05 Nov 2024 15:39:47 +0000 Fire resistance tests for non-loadbearing elements - Part 6: Cavity Barriers (Draft)
Published By Publication Date Number of Pages
DIN 2016-05 64
]]>
This test method specifies a method for determining the fire resistance of cavity barriers and is to be used in conjunction with EN 1363-1. This standard is applicable to non-loadbearing vertically or horizontally oriented closed and open cavity barriers, which are used to provide fire separation to uncompartmented or ventilated spaces. Cavity barriers are designed to provide fire separating performance and the test method is therefore based on the standard room fire exposure in EN 1363-1. Open cavity barrier specimens are installed for test in one of two ways to simulate slow or sudden exposure in use. This standard is not applicable to cavity barriers containing penetration seals, which are to be tested in accordance with EN 1366-3.

]]>
DIN EN 1364-5:2017 Edition ?u=/product/publishers/din/din-en-1364-5/ Tue, 05 Nov 2024 15:39:47 +0000 Fire resistance tests for non-loadbearing elements - Part 5: Air transfer grilles
Published By Publication Date Number of Pages
DIN 2017-09 28
]]>
This European Standard specifies a method for determining the fire resistance of air transfer grilles (ATG). It is applicable to air transfer grilles intended for installation in building components (typically walls, floors or ceilings). The orientation of the installation of the air transfer grille can be vertical or horizontal. The closing mechanism of the air transfer grille can come from expansion of material and/or from any mechanical or electrical closing device. This test method is valid for fire resistant or fire resistant and smoke control air transfer grilles. An additional test configuration is valid for fire resistant or fire resistant and smoke control air transfer grilles in applications where flame impingement is a risk during open state from start of fire (Annex A). This test method evaluates the behaviour of the air transfer grille when exposed to the standard fire curve described in EN 1363 1 and the standard pressure described in EN 1363 1. It is not the intention of this test to provide quantitative information on the rate of leakage of smoke and/or hot gases or on the transmission or generation of fumes under fire conditions. Such phenomena are only to be noted in describing the general behaviour of test specimens during the test.

]]>