91.100.60 – Thermal and sound insulating materials – PDF Standards Store ?u= Wed, 06 Nov 2024 01:41:41 +0000 en-US hourly 1 https://wordpress.org/?v=6.7.1 ?u=/wp-content/uploads/2024/11/cropped-icon-150x150.png 91.100.60 – Thermal and sound insulating materials – PDF Standards Store ?u= 32 32 JIS A 9526:2015 ?u=/product/publishers/jis/jis-a-95262015/ Wed, 06 Nov 2024 01:41:41 +0000 Spray-applied rigid polyurethane foam for thermal insulation
Published By Publication Date Number of Pages
JIS 2015-12-21 18
]]>
This Standard specifies the spray-applied rigid polyurethane foam stock solution mainly used for the thermal insulation working at construction site and the thermal insulation products manufactured in factory.

This Standard specifies the quality of stock solution based on the specification of the quality of spray-applied rigid polyurethane foam obtained when it is spray-applied under definite conditions where the actual application is assumed.

]]>
JIS A 9529:2020 ?u=/product/publishers/jis/jis-a-95292020/ Wed, 06 Nov 2024 01:41:41 +0000 Vacuum insulation panels for buildings
Published By Publication Date Number of Pages
JIS 2020-02-20 23
]]>
This Japanese Industrial Standard specifies requirements for the vacuum insulation panels (VIPs) for buildings which use silica particles and glass wool core as core material. It is not applicable to VIPs used under special hygrothermal environment such as cold storage warehouses, or to those used for facility equipment, piping, etc. in residences and buildings.

NOTE Some VIPs for buildings have unfolded edges.

]]>
JIS A 9521:2017 ?u=/product/publishers/jis/jis-a-95212017/ Wed, 06 Nov 2024 01:41:38 +0000 Thermal insulation materials for buildings
Published By Publication Date Number of Pages
JIS 2017-03-21 76
]]>
This Japanese Industrial Standard specifies the thermal insulation materials mainly used for dwellings or buildings at the ordinary temperature (hereafter referred to as thermal insulation materials).

This Standard is not applicable to the heat insulation materials used under atmospheric conditions of particular temperature and humidity such as a cold-storage warehouse, and the heat insulation materials used for facility equipment, piping, etc. for dwellings or buildings.

This Standard is applicable to the cellular plastic thermal insulation materials in which fluorocarbons 1) are not used as a foaming agent.

The comparison table between previous and current editions of this Standard on technically significant revisions is given in Annex 1.

Note 1) Generic term for hydrofluorocarbon (HFC), chlorofluorocarbon (CFC) and hydrochlorofluorocarbon (HCFC).

Hydrofluoroolefin (HFO) (HFO-1233zd, HFO-1336mzz and others) does not fall under this category.

]]>
JIS A 9521:2017/Amendment 1:2020 ?u=/product/publishers/jis/jis-a-95212017-amendment-12020/ Wed, 06 Nov 2024 01:41:38 +0000 Thermal insulation materials for buildings (Amendment 1)
Published By Publication Date Number of Pages
JIS 2020-02-20 5
]]>
Thermal insulation materials for buildings (Amendment 1)
Published By Publication Date Number of Pages
JIS 2020-02-20 5
]]>
JIS A 9521:2014 ?u=/product/publishers/jis/jis-a-95212014/ Wed, 06 Nov 2024 01:41:37 +0000 Thermal insulation materials for buildings
Published By Publication Date Number of Pages
JIS 2014-09-22 54
]]>
This Japanese Industrial Standard specifies the thermal insulation materials mainly used for dwellings or buildings at the ordinary temperature (hereafter referred to as "thermal insulation materials").

In this Standard, the cellular plastics thermal insulation materials in which fluorocarbons1) are not used as a foaming agent are included in the scope.

This Standard is not applicable to the thermal insulation materials used under the condition at particular temperature and humidity such as a cold-storage warehouse, and the heat insulation materials used for facility equipment, piping, etc. for dwellings or buildings.

Note 1)Fluorocarbons refer to chlorofluorocarbon (CFC), hydrochlorofluorocarbon (HCFC) and hydrofluorocarbon (HFC), but do not include hydrofluoroolefin (HFO) which is represented by HFO-1233zd and HFO-1336mzz.

]]>
JIS A 9521:1981 ?u=/product/publishers/jis/jis-a-95211981/ Wed, 06 Nov 2024 01:41:36 +0000 Rock Wool Thermal Insulating Material for Dwellings
Published By Publication Date Number of Pages
JIS 1981-08-01 9
]]>
Rock Wool Thermal Insulating Material for Dwellings
Published By Publication Date Number of Pages
JIS 1981-08-01 9
]]>
JIS A 9511:2017 ?u=/product/publishers/jis/jis-a-95112017/ Wed, 06 Nov 2024 01:41:36 +0000 Preformed cellular plastics thermal insulation materials
Published By Publication Date Number of Pages
JIS 2017-03-21 40
]]>
This Standard specifies the preformed cellular plastics thermal insulation materials to be used as thermal insulator.

This Standard is mainly applicable to thermal insulation materials intended for general industrial applications, and also applicable to those used under special temperature and humidity conditions such as in a cold-storage warehouse, and those used for facility equipment, piping, etc. of dwellings or buildings.

It is not applicable to insulation materials for dwellings and buildings that are mainly intended for use at the ordinary temperature.

The comparison table between previous and current editions of this Standard on technically significant revisions is given in Annex A.

]]>
JIS A 9511:2006/Amendment 1:2009 ?u=/product/publishers/jis/jis-a-95112006-amendment-12009/ Wed, 06 Nov 2024 01:41:36 +0000 Preformed cellular plastics thermal insulation materials
Published By Publication Date Number of Pages
JIS 2009-08-20 5
]]>
Preformed cellular plastics thermal insulation materials
Published By Publication Date Number of Pages
JIS 2009-08-20 5
]]>
JIS A 9511:1995 ?u=/product/publishers/jis/jis-a-95111995/ Wed, 06 Nov 2024 01:41:35 +0000 Preformed Cellular Plastics Thermal Insulation Materials
Published By Publication Date Number of Pages
JIS 1995-05-01 30
]]>
Preformed Cellular Plastics Thermal Insulation Materials
Published By Publication Date Number of Pages
JIS 1995-05-01 30
]]>
JIS A 9511:2006 ?u=/product/publishers/jis/jis-a-95112006/ Wed, 06 Nov 2024 01:41:35 +0000 Preformed Cellular Plastics Thermal Insulation Materials
Published By Publication Date Number of Pages
JIS 2006-11-20 36
]]>
Preformed Cellular Plastics Thermal Insulation Materials
Published By Publication Date Number of Pages
JIS 2006-11-20 36
]]>