91.140.65 – Water heating equipment – PDF Standards Store ?u= Wed, 06 Nov 2024 05:12:21 +0000 en-US hourly 1 https://wordpress.org/?v=6.7.1 ?u=/wp-content/uploads/2024/11/cropped-icon-150x150.png 91.140.65 – Water heating equipment – PDF Standards Store ?u= 32 32 NZS 4604:1990:1991 Edition ?u=/product/publishers/snz/nzs-46041990/ Wed, 06 Nov 2024 05:12:21 +0000 Dairy-type thermal storage electric water heaters
Published By Publication Date Number of Pages
SNZ 1991-01-18 12
]]>
Applies to the design, materials, construction and performance of thermostatically controlled dairy-type thermal storage electric water heaters of 150 to 450 litres capacity. Insulation requirements and basic constructional requirements are aligned with those of NZS 4602 and/or NZS 4606.

]]>
NZS 4605:1978 ?u=/product/publishers/snz/nzs-46051978/ Wed, 06 Nov 2024 05:12:21 +0000 Code of practice for the installation of dairy-type thermal storage electric water heaters
Published By Publication Date Number of Pages
SNZ 1978 16
]]>
Applies to the installation in farm dairies of hot water supply systems for the cleaning and sanitizing of milk handling equipment in which the main source of heating is a dairy-type thermal storage electric water heater (or heaters) complying with the requirements of NZS 4604.

]]>
JIS S 3027:2009/Amendment 3:2013 ?u=/product/publishers/jis/jis-s-30272009-amendment-32013/ Wed, 06 Nov 2024 02:51:02 +0000 Oil burning bath boilers with water heaters for domestic use (Amendment 3)
Published By Publication Date Number of Pages
JIS 2013-02-20 5
]]>
Oil burning bath boilers with water heaters for domestic use (Amendment 3)
Published By Publication Date Number of Pages
JIS 2013-02-20 5
]]>
JIS S 3027:2009/Amendment 2:2011 ?u=/product/publishers/jis/jis-s-30272009-amendment-22011/ Wed, 06 Nov 2024 02:51:02 +0000 Oil burning bath boilers with water heaters for domestic use (Amendment 2)
Published By Publication Date Number of Pages
JIS 2011-03-22 5
]]>
This Standard specifies the bath boilers fueled by kerosene, gas oil or heavy oil with a fuel consumption1) of 70 kW or less and a heat exchanger capacity2) of 50 L or less (hereafter referred to as "bath boilers").

However, the fuel consumption of the burner directly heating the heat exchange for bath boiler shall not be more than 39 kW.

Notes 1) The fuel consumption means a value of burning amount at the maximum burning indicated in the unit per hour, and if there are two or more burners, by the total of them.

2) Heat exchanger capacity is the volume of the water from the inlet to the outlet of the water channel, i.e. the total sum of water volume in hot-water supply path and bath boiler path.

The hot-water supply path is the channel through which the warm water is taken for hot-water supply and the bath boiler path is the channel through which the warm water is taken for bath boiler.

]]>
JIS S 3027:2009/Amendment 1:2010 ?u=/product/publishers/jis/jis-s-30272009-amendment-12010/ Wed, 06 Nov 2024 02:51:01 +0000 Oil burning bath boilers with water heaters for domestic use (Amendment 1)
Published By Publication Date Number of Pages
JIS 2010-03-23 5
]]>
This Standard specifies the bath boilers fueled by kerosene, gas oil or heavy oil with a fuel consumption1) of 70 kW or less and a heat exchanger capacity2) of 50 L or less (hereafter referred to as "bath boilers").

However, the fuel consumption of the burner directly heating the heat exchange for bath boiler shall not be more than 39 kW.

Notes 1) The fuel consumption means a value of burning amount at the maximum burning indicated in the unit per hour, and if there are two or more burners, by the total of them.

2) Heat exchanger capacity is the volume of the water from the inlet to the outlet of the water channel, i.e. the total sum of water volume in hot-water supply path and bath boiler path.

The hot-water supply path is the channel through which the warm water is taken for hot-water supply and the bath boiler path is the channel through which the warm water is taken for bath boiler.

]]>
JIS S 3027:2009 ?u=/product/publishers/jis/jis-s-30272009/ Wed, 06 Nov 2024 02:51:00 +0000 Oil burning bath boilers with water heaters for domestic use
Published By Publication Date Number of Pages
JIS 2009-03-20 42
]]>
This Standard specifies the bath boilers fueled by kerosene, gas oil or heavy oil with a fuel consumption1) of 70 kW or less and a heat exchanger capacity2) of 50 L or less (hereafter referred to as "bath boilers").

However, the fuel consumption of the burner directly heating the heat exchange for bath boiler shall not be more than 39 kW.

Notes 1) The fuel consumption means a value of burning amount at the maximum burning indicated in the unit per hour, and if there are two or more burners, by the total of them.

2) Heat exchanger capacity is the volume of the water from the inlet to the outlet of the water channel, i.e. the total sum of water volume in hot-water supply path and bath boiler path.

The hot-water supply path is the channel through which the warm water is taken for hot-water supply and the bath boiler path is the channel through which the warm water is taken for bath boiler.

]]>
JIS S 3024:2009/Amendment 2:2011 ?u=/product/publishers/jis/jis-s-30242009-amendment-22011/ Wed, 06 Nov 2024 02:50:58 +0000 Oil burning water heaters for domestic use (Amendment 2)
Published By Publication Date Number of Pages
JIS 2011-03-22 5
]]>
This Standard specifies oil burning water heaters for domestic use mainly for hot water supply, fueled by kerosine, light oil or fuel oil, with a fuel consumption1) of 70 kW or less and a heat exchanger capacity of 30 L or less (hereafter referred to as "water heaters").

Note 1) The fuel consumption means a value of burning amount at the maximum burning indicated in calorific value per hour.

]]>
JIS S 3024:2009/Amendment 3:2013 ?u=/product/publishers/jis/jis-s-30242009-amendment-32013/ Wed, 06 Nov 2024 02:50:58 +0000 Oil burning water heaters for domestic use (Amendment 3)
Published By Publication Date Number of Pages
JIS 2013-02-20 5
]]>
Oil burning water heaters for domestic use (Amendment 3)
Published By Publication Date Number of Pages
JIS 2013-02-20 5
]]>
JIS S 3024:2009 ?u=/product/publishers/jis/jis-s-30242009/ Wed, 06 Nov 2024 02:50:57 +0000 Oil burning water heaters for domestic use
Published By Publication Date Number of Pages
JIS 2009-03-20 32
]]>
This Standard specifies oil burning water heaters for domestic use mainly for hot water supply, fueled by kerosine, light oil or fuel oil, with a fuel consumption1) of 70 kW or less and a heat exchanger capacity of 30 L or less (hereafter referred to as "water heaters").

Note 1) The fuel consumption means a value of burning amount at the maximum burning indicated in calorific value per hour.

]]>
JIS S 3024:2009/Amendment 1:2010 ?u=/product/publishers/jis/jis-s-30242009-amendment-12010/ Wed, 06 Nov 2024 02:50:57 +0000 Oil burning water heaters for domestic use (Amendment 1)
Published By Publication Date Number of Pages
JIS 2010-03-23 5
]]>
This Standard specifies oil burning water heaters for domestic use mainly for hot water supply, fueled by kerosine, light oil or fuel oil, with a fuel consumption1) of 70 kW or less and a heat exchanger capacity of 30 L or less (hereafter referred to as "water heaters").

Note 1) The fuel consumption means a value of burning amount at the maximum burning indicated in calorific value per hour.

]]>