ECIA – PDF Standards Store ?u= Tue, 05 Nov 2024 18:16:38 +0000 en-US hourly 1 https://wordpress.org/?v=6.7.1 ?u=/wp-content/uploads/2024/11/cropped-icon-150x150.png ECIA – PDF Standards Store ?u= 32 32 EIA/IS 749-1998 ?u=/product/publishers/ecia/eia-is-749-1998/ Tue, 05 Nov 2024 18:16:38 +0000 Rectified Mains Application Expected Wear-Out Lifetime Test
Published By Publication Date Number of Pages
ECIA 1998 8
]]>
This test procedure determines the expected wear-out lifetime
for aluminum electrolytic capacitors. It provides a measure of the
operating time required for parametric changes to cause capacitors
to become unusable as filter capacitors on rectified mains
applications. While it measures the time till wear-out, it does not
indicate failure rate during the operating life. Wear-out is
defined by conditions specified in table 1. Measurements are to be
taken periodically and the measurements are to be taken at the same
temperature throughout the test.

]]>
EIA/IS 722-1997 ?u=/product/publishers/ecia/eia-is-722-1997/ Tue, 05 Nov 2024 18:16:37 +0000 Low-Voltage Supplemental Fuse Qualification Specification
Published By Publication Date Number of Pages
ECIA 1997 31
]]>
Description

This specification defines the qualification program for low
voltage, supplemental fuses. Fuses covered will be limited to
axial-leaded, radial-leaded and surface mount configurations having
a current rating of no greater than 60 A, maximum voltage rating of
600 VAC/DC and interrupting rating of 10,000 A maximum. The
qualification program is defined in table 1, and the flow diagram.
Specification sheets can be added, as required, to define specific
products or to cover unique / specific requirements. This document
does not relieve the suppliers of their responsibility to maintain
their own company's internal qualification program and the fuses
shall continue to meet all applicable requirements of UL 248-14 /
CSA-C22.2 NO. 248.14.

Three types of fuses are covered in this specification. They
include:

Type I – The type I fuse is designed to operate (open) within a
given time period at 200% overload. The remainder of this
specification is written with the 200% overload test used as the
standard.

Type II – The type II fuse is designed to operate (open) within
a given time period at 250% overload. For a Type II fuse, the 250%
overload shall be substituted throughout this specification where
200% overload is noted. All other requirements shall continue to be
met.

Type III – The type III fuse is designed to operate (open)
within a given time period at 300% overload. For a Type III fuse,
the 300% overload shall be substituted throughout this
specification where 200% overload is noted. All other requirements
shall continue to be met.

Preconditioning

This process is intended to simulate exposure to the thermal and
cleaning environments of the assembly process before qualification
testing. The component assembly process simulation requirements for
different types of processes are described in annex A.

]]>
EIA/IS 535BAAE-1998 ?u=/product/publishers/ecia/eia-is-535baae-1998/ Tue, 05 Nov 2024 18:16:37 +0000 Detail Specification for Low ESR Molded Tantalum Chip
Published By Publication Date Number of Pages
ECIA 1998 13
]]>
Detail Specification for Low ESR Molded Tantalum Chip
Published By Publication Date Number of Pages
ECIA 1998 13
]]>
EIA/IS 692-1996 ?u=/product/publishers/ecia/eia-is-692-1996/ Tue, 05 Nov 2024 18:16:37 +0000 Ceramic Capacitor Qualification Specification
Published By Publication Date Number of Pages
ECIA 1996 21
]]>
Description

This specification defines the qualification program for ceramic
capacitors. The qualification program is defined in table 1.
Specification sheets can be added, as required, to define specific
products or to cover unique/specific requirements.

Preconditioning

This process is intended to simulate exposure to the thermal and
cleaning environments of the assembly process before qualification
testing. The component assembly process simulation requirements for
different types of processes are described in annex A

]]>
EIA/IS 43AH-1988 ?u=/product/publishers/ecia/eia-is-43ah-1988/ Tue, 05 Nov 2024 18:16:36 +0000 Cable for LAN Twisted Pair Data Communications - Detail Specification for Type 8, Undercarpet Cable
Published By Publication Date Number of Pages
ECIA 1988 16
]]>
This Detail Specification defines Type 8 Undercarpet cable used
with the Token Ring LAN Cabling System. Type 8 cable consists of 2
parallel pairs of data grade wires shielded with copper foil, all
cabled into a single, flat, PVC assembly with tapered flanges on
each side to reduce visibility when installed under carpet. The
Cabling System is intended to be compatible with IEEE Standard
802.5. It is designed to be used as a total building wiring system.
The Cabling System may be used as the communications medium for a
Token Ring Network as well as for other data equipment.

]]>
EIA/IS 46-1987 ?u=/product/publishers/ecia/eia-is-46-1987/ Tue, 05 Nov 2024 18:16:36 +0000 Test Procedure for Resistance to Soldering (Vapor Phase Technique) for Surface Mount Devices
Published By Publication Date Number of Pages
ECIA 1987 5
]]>
There are two basic processes for soldering surface mount
connectors — vapor phase and infra-red. Both apply heat which the
total connector systems is exposed to with no insulating medium
(e.g. printed circuit boards) between the termination and connector
assembly. In addition to heat, the vapor phase system employs a
chemical medium (perfluoro-carbon) in a vapor form. Connector
materials are exposed to these mediums and thus must withstand both
heat and chemical vapors. There are three basic features which must
be evaluated prior to a material or connector configuration being
acceptable for surface mount process. These factors are:

A: Heat Impact

B: Dimensional Stability

C: Chemical Resistance

This procedure establishes a technique to evaluate plastic
materials used for connector housings which will be exposed to a
vapor phase reflow process.

]]>
EIA/IS 48-1988 ?u=/product/publishers/ecia/eia-is-48-1988/ Tue, 05 Nov 2024 18:16:36 +0000 Axial Lead Fixed Radio Frequency (RF) Coils
Published By Publication Date Number of Pages
ECIA 1988 27
]]>
This standard covers industrial grade RF coils which are
intended as simple inductive elements in RF circuits. They are
primarily intended for machine packaging, insertion and soldering
on printed wiring boards.

NOTE: The parts described by this standard and the test
procedures are based on inductance measurements using an Analog Q
Meter System.

]]>
EIA/IS 43AJ-1988 ?u=/product/publishers/ecia/eia-is-43aj-1988/ Tue, 05 Nov 2024 18:16:36 +0000 Cable for LAN Twisted Pair Data Communications - Detail Specification for Type 9, Plenum Cable
Published By Publication Date Number of Pages
ECIA 1988 14
]]>
This Detail Specification defines Type 9 Plenum cable used with
the Token Ring LAN Cabling System. Type 9 P consists of 2 twisted
pairs of Data Grade Media (DGM) shielded with aluminum tape and
braided shields, all cabled into a single fluorocarbon jacketed
assembly. The Cabling System is intended to be compatible with IEEE
Standard 802.5. It is designed to be used as a total building
wiring system. The Cabling System may be used as the communications
medium for a Token Ring Network as well as for other data
equipment.

OBJECTIVE

The objective of the Detail Specification is to provide a
document describing Type 9 P cable as a basis for certification
under the NECQ system and for acquisition of conforming cable.

]]>
EIA/IS 43AF-1988 ?u=/product/publishers/ecia/eia-is-43af-1988/ Tue, 05 Nov 2024 18:16:35 +0000 Cable for LAN Twisted Pair Data Communications - Detail Specification for Type 2, Plenum Cable
Published By Publication Date Number of Pages
ECIA 1988 18
]]>
This Detail Specification defines Type 2 Plenum cable used with
the Token Ring LAN Cabling System. Type 2 P consists of 2 twisted
pairs of Data Grade Media (DGM) shielded with aluminum tape and
braided shields, all cabled into a single fluorocarbon jacketed
assembly. The Cabling System is intended to be compatible with IEEE
Standard 802.5. It is designed to be used as a total building
wiring system. The Cabling System may be used as the communications
medium for a Token Ring Network as well as for other data
equipment.

]]>
EIA/IS 39-1987 ?u=/product/publishers/ecia/eia-is-39-1987/ Tue, 05 Nov 2024 18:16:34 +0000 Ceramic Dielectric Axial Capacitors (Glass Encapsulated)
Published By Publication Date Number of Pages
ECIA 1987 9
]]>
Ceramic Dielectric Axial Capacitors (Glass Encapsulated)
Published By Publication Date Number of Pages
ECIA 1987 9
]]>