{"id":110516,"date":"2024-10-18T15:55:47","date_gmt":"2024-10-18T15:55:47","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/nfpa-25-water-based-fire-protection-systems-handbook-2014\/"},"modified":"2024-10-24T21:57:41","modified_gmt":"2024-10-24T21:57:41","slug":"nfpa-25-water-based-fire-protection-systems-handbook-2014","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/nfpa\/nfpa-25-water-based-fire-protection-systems-handbook-2014\/","title":{"rendered":"NFPA 25: Water-Based Fire Protection Systems Handbook 2014"},"content":{"rendered":"

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nCover Page <\/td>\n<\/tr>\n
2<\/td>\nCopyright <\/td>\n<\/tr>\n
3<\/td>\nTable of Contents <\/td>\n<\/tr>\n
5<\/td>\nPreface <\/td>\n<\/tr>\n
7<\/td>\nAbout the Contributors <\/td>\n<\/tr>\n
10<\/td>\nAbout the Editor <\/td>\n<\/tr>\n
13<\/td>\nPART ONE – NFPA 25, Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems, 2014 Edition, with Commentary <\/td>\n<\/tr>\n
15<\/td>\n1 Administration
1.1 Scope <\/td>\n<\/tr>\n
20<\/td>\n1.2 Purpose <\/td>\n<\/tr>\n
21<\/td>\n1.3 Application <\/td>\n<\/tr>\n
22<\/td>\n1.4 Units <\/td>\n<\/tr>\n
25<\/td>\n2 Referenced Publications
2.1 General
2.2 NFPA Publications <\/td>\n<\/tr>\n
26<\/td>\n2.3 Other Publications
2.4 References for Extracts in Mandatory Sections <\/td>\n<\/tr>\n
27<\/td>\n3 Definitions
3.1 General
3.2 NFPA Official Definitions <\/td>\n<\/tr>\n
29<\/td>\n3.3 General Definitions <\/td>\n<\/tr>\n
74<\/td>\n3.4 Deluge Foam-Water Sprinkler and Foam-Water Spray Systems Definitions <\/td>\n<\/tr>\n
75<\/td>\n3.5 Valve Definitions <\/td>\n<\/tr>\n
77<\/td>\n3.6 Water-Based Fire Protection System Definitions <\/td>\n<\/tr>\n
85<\/td>\n3.7 ITM Task Frequencies <\/td>\n<\/tr>\n
89<\/td>\n4 General Requirements
4.1 Responsibility of Property Owner or Designated Representative <\/td>\n<\/tr>\n
104<\/td>\n4.2 Manufacturer\u2019s Corrective Action
4.3 Records <\/td>\n<\/tr>\n
107<\/td>\n4.4 Water Supply Status
4.5 Inspection <\/td>\n<\/tr>\n
108<\/td>\n4.6 Testing <\/td>\n<\/tr>\n
109<\/td>\n4.7 Performanced-Based Programs <\/td>\n<\/tr>\n
111<\/td>\n4.8 Maintenance <\/td>\n<\/tr>\n
112<\/td>\n4.9 Safety <\/td>\n<\/tr>\n
125<\/td>\n5 Sprinkler Systems
5.1 General <\/td>\n<\/tr>\n
127<\/td>\n5.2 Inspection <\/td>\n<\/tr>\n
157<\/td>\n5.3 Testing <\/td>\n<\/tr>\n
173<\/td>\n5.4 Maintenance <\/td>\n<\/tr>\n
179<\/td>\n5.5 Component Action Requirements <\/td>\n<\/tr>\n
185<\/td>\n6 Standpipe and Hose Systems <\/td>\n<\/tr>\n
186<\/td>\n6.1 General <\/td>\n<\/tr>\n
189<\/td>\n6.2 Inspection <\/td>\n<\/tr>\n
191<\/td>\n6.3 Testing <\/td>\n<\/tr>\n
195<\/td>\n6.4 Maintenance
6.5 Component Action Requirements <\/td>\n<\/tr>\n
201<\/td>\n7 Private Fire Service Mains
7.1 General <\/td>\n<\/tr>\n
204<\/td>\n7.2 Inspection and Corrective Action <\/td>\n<\/tr>\n
211<\/td>\n7.3 Testing <\/td>\n<\/tr>\n
212<\/td>\n7.4 Maintenance <\/td>\n<\/tr>\n
213<\/td>\n7.5 Component Action Requirements <\/td>\n<\/tr>\n
221<\/td>\n8 Fire Pumps
8.1 General <\/td>\n<\/tr>\n
239<\/td>\n8.2 Inspection <\/td>\n<\/tr>\n
249<\/td>\n8.3 Testing <\/td>\n<\/tr>\n
275<\/td>\n8.4 Reports
8.5 Maintenance <\/td>\n<\/tr>\n
277<\/td>\n8.6 Component Replacement Testing Requirements <\/td>\n<\/tr>\n
301<\/td>\n9 Water Storage Tanks <\/td>\n<\/tr>\n
302<\/td>\n9.1 General <\/td>\n<\/tr>\n
308<\/td>\n9.2 Inspection <\/td>\n<\/tr>\n
318<\/td>\n9.3 Testing <\/td>\n<\/tr>\n
321<\/td>\n9.4 Maintenance <\/td>\n<\/tr>\n
322<\/td>\n9.5 Automatic Tank Fill Valves <\/td>\n<\/tr>\n
325<\/td>\n9.6 Component Action Requirements <\/td>\n<\/tr>\n
333<\/td>\n10 Water Spray Fixed Systems <\/td>\n<\/tr>\n
334<\/td>\n10.1 General <\/td>\n<\/tr>\n
341<\/td>\n10.2 Inspection and Maintenance Procedures <\/td>\n<\/tr>\n
349<\/td>\n10.3 Operational Tests <\/td>\n<\/tr>\n
353<\/td>\n10.4 Ultra-High-Speed Water Spray System (UHSWSS) Operational Tests
10.5 Component Action Requirements <\/td>\n<\/tr>\n
357<\/td>\n11 Foam-Water Sprinkler Systems <\/td>\n<\/tr>\n
358<\/td>\n11.1 General <\/td>\n<\/tr>\n
362<\/td>\n11.2 Inspection <\/td>\n<\/tr>\n
368<\/td>\n11.3 Operational Tests <\/td>\n<\/tr>\n
373<\/td>\n11.4 Maintenance <\/td>\n<\/tr>\n
375<\/td>\n11.5 Component Action Requirements <\/td>\n<\/tr>\n
383<\/td>\n12 Water Mist Systems <\/td>\n<\/tr>\n
384<\/td>\n12.1 Inspection and Testing <\/td>\n<\/tr>\n
402<\/td>\n12.2 Maintenance <\/td>\n<\/tr>\n
404<\/td>\n12.3 Training <\/td>\n<\/tr>\n
407<\/td>\n13 Valves, Valve Components, and Trim
13.1 General <\/td>\n<\/tr>\n
419<\/td>\n13.2 General Provisions <\/td>\n<\/tr>\n
427<\/td>\n13.3 Control Valves in Water-Based Fire Protection Systems <\/td>\n<\/tr>\n
433<\/td>\n13.4 System Valves <\/td>\n<\/tr>\n
447<\/td>\n13.5 Pressure-Reducing Valves and Relief Valves <\/td>\n<\/tr>\n
456<\/td>\n13.6 Backflow Prevention Assemblies <\/td>\n<\/tr>\n
457<\/td>\n13.7 Fire Department Connections <\/td>\n<\/tr>\n
461<\/td>\n13.8 Component Testing Requirements <\/td>\n<\/tr>\n
487<\/td>\n14 Internal Piping Condition and Obstruction Investigation
14.1 General
14.2 Assessment of Internal Condition of Piping <\/td>\n<\/tr>\n
498<\/td>\n14.3 Obstruction Investigation and Prevention <\/td>\n<\/tr>\n
501<\/td>\n14.4 Ice Obstruction <\/td>\n<\/tr>\n
503<\/td>\n15 Impairments
15.1 General <\/td>\n<\/tr>\n
504<\/td>\n15.2 Impairment Coordinator
15.3 Tag Impairment System <\/td>\n<\/tr>\n
505<\/td>\n15.4 Impaired Equipment <\/td>\n<\/tr>\n
506<\/td>\n15.5 Preplanned Impairment Programs <\/td>\n<\/tr>\n
509<\/td>\n15.6 Emergency Impairments <\/td>\n<\/tr>\n
510<\/td>\n15.7 Restoring Systems to Service <\/td>\n<\/tr>\n
513<\/td>\n16 Special Requirements from Other NFPA Documents
16.1 General <\/td>\n<\/tr>\n
514<\/td>\n16.2 Small Residential Board and Care Occupancies <\/td>\n<\/tr>\n
517<\/td>\nANNEXES
A Explanatory Material <\/td>\n<\/tr>\n
519<\/td>\nB Forms for Testing, Inspection, and Maintenance <\/td>\n<\/tr>\n
521<\/td>\nC Possible Causes of Pump Troubles <\/td>\n<\/tr>\n
529<\/td>\nD Obstruction Investigation <\/td>\n<\/tr>\n
549<\/td>\nE Hazard Evaluation Form <\/td>\n<\/tr>\n
555<\/td>\nF Informational References <\/td>\n<\/tr>\n
559<\/td>\nPART TWO – Supplements <\/td>\n<\/tr>\n
561<\/td>\n1 Microbiologically Influenced Corrosion in Fire Sprinkler Systems <\/td>\n<\/tr>\n
573<\/td>\n2 Conducting Fire Pump Flow Tests <\/td>\n<\/tr>\n
593<\/td>\n3 ITM Roles and Responsibilities <\/td>\n<\/tr>\n
603<\/td>\n4 Role of the Inspector <\/td>\n<\/tr>\n
617<\/td>\n5 Role of the Owner or Designated Representative <\/td>\n<\/tr>\n
629<\/td>\n6 Role of the Authority Having Jurisdiction <\/td>\n<\/tr>\n
643<\/td>\n7 Fire Pump Field Data Collection and Analysis <\/td>\n<\/tr>\n
647<\/td>\n8 Technical\/Substantive Changes from the 2011 Edition to the 2014 Edition of NFPA 25 <\/td>\n<\/tr>\n
679<\/td>\nIndex <\/td>\n<\/tr>\n
689<\/td>\nImportant Notices and Legal Disclaimers <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

NFPA 25: Water-Based Fire Protection Systems Handbook<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
NFPA<\/b><\/a><\/td>\n2014<\/td>\n696<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":110517,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2638],"product_tag":[],"class_list":{"0":"post-110516","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-nfpa","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/110516","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/110517"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=110516"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=110516"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=110516"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}