{"id":111270,"date":"2024-10-18T16:08:31","date_gmt":"2024-10-18T16:08:31","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-c57-16-1996\/"},"modified":"2024-10-24T22:00:55","modified_gmt":"2024-10-24T22:00:55","slug":"ieee-c57-16-1996","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-c57-16-1996\/","title":{"rendered":"IEEE C57.16 1996"},"content":{"rendered":"

New IEEE Standard – Inactive – Superseded. Series-Connected dry-type air-core single-phase and three-phase outdoor or indoor reactors of distribution and transmission voltage class that are connected in the power system to control power flow under steady-state conditions and\/or limit fault current under short-circuit conditions are covered. Dry-Type air-core reactors covered by this standard are self-cooled by natural air convection. With some restrictions, other reactors, including shunt capacitor reactors (used with shunt capacitor banks), filter reactors, shunt capacitor reactors (used with series capacitor banks), and discharge current-limiting reactors, are also covered.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nTitle Page <\/td>\n<\/tr>\n
3<\/td>\nIntroduction
Participants <\/td>\n<\/tr>\n
6<\/td>\nCONTENTS <\/td>\n<\/tr>\n
9<\/td>\n1. Overview
1.1 Scope
1.2 Purpose <\/td>\n<\/tr>\n
10<\/td>\n2. References <\/td>\n<\/tr>\n
11<\/td>\n3. Definitions <\/td>\n<\/tr>\n
14<\/td>\n4. General requirements
4.1 Service conditions <\/td>\n<\/tr>\n
15<\/td>\n4.2 Insulation
4.3 Operation of altitudes in excess of 1000 m (3300 ft) <\/td>\n<\/tr>\n
17<\/td>\n5. Rating
5.1 Basis of rating
5.2 System frequency
5.3 Reactance rating <\/td>\n<\/tr>\n
18<\/td>\n5.4 Voltage rating
5.5 Continuous current rating
5.6 Short-Circuit current rating <\/td>\n<\/tr>\n
20<\/td>\n6. Tests
6.1 Routine, design, and other tests for series reactors <\/td>\n<\/tr>\n
22<\/td>\n6.2 Where tests are to be made
6.3 Test sequence
6.4 Test procedures
7. Losses and impedance
7.1 Losses <\/td>\n<\/tr>\n
23<\/td>\n7.2 Impedance
7.3 Impedance and losses test <\/td>\n<\/tr>\n
24<\/td>\n8. Temperature rise
8.1 Considerations in establishing limits of temperature rise <\/td>\n<\/tr>\n
25<\/td>\n8.2 Limits of temperature rise <\/td>\n<\/tr>\n
27<\/td>\n8.3 Temperature rise tests <\/td>\n<\/tr>\n
28<\/td>\n9. Insulation levels and dielectric tests
9.1 Impulse insulation levels <\/td>\n<\/tr>\n
29<\/td>\n9.2 Dielectic test levels <\/td>\n<\/tr>\n
30<\/td>\n9.3 Dielectric tests <\/td>\n<\/tr>\n
31<\/td>\n10. Short-Circuit capability
10.1 Short-Circuit description
10.2 Maximum mechanical stress of series reactors for short-circuit conditions <\/td>\n<\/tr>\n
33<\/td>\n10.3 Thermal limit of series reactors for short-circuit conditions
10.4 Mechanical short-circuit test
11. Test code
11.1 General <\/td>\n<\/tr>\n
34<\/td>\n11.2 Resistance measurements <\/td>\n<\/tr>\n
37<\/td>\n11.3 Dielectric tests <\/td>\n<\/tr>\n
43<\/td>\n11.4 Losses and impedance <\/td>\n<\/tr>\n
46<\/td>\n11.5 Temperature rise tests <\/td>\n<\/tr>\n
51<\/td>\n11.6 Short-Circuit test <\/td>\n<\/tr>\n
54<\/td>\n11.7 Short-Time current <\/td>\n<\/tr>\n
55<\/td>\n11.8 Audible sound-level test <\/td>\n<\/tr>\n
59<\/td>\n11.9 Seismic verification test
12. Construction
12.1 Nameplates <\/td>\n<\/tr>\n
60<\/td>\n12.2 Insulator units
12.3 Tap (in a reactor) <\/td>\n<\/tr>\n
61<\/td>\nAnnex A\u2014Specific requirements for dry-type air-core filter reactors <\/td>\n<\/tr>\n
73<\/td>\nAnnex B\u2014Specific requirements for dry-type air-core shunt capacitor reactors <\/td>\n<\/tr>\n
81<\/td>\nAnnex C\u2014Specific requirements for dry-type air-core discharge current-limiting reactors for series capacitor bank application <\/td>\n<\/tr>\n
89<\/td>\nAnnex D\u2014Construction and installation of dry-type air-core series reactors <\/td>\n<\/tr>\n
95<\/td>\nAnnex E\u2014Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

IEEE Standard Requirements, Terminology, and Test Code for Dry-Type Air-Core Series-Connected Reactors<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
IEEE<\/b><\/a><\/td>\n1997<\/td>\n95<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":111271,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2644],"product_tag":[],"class_list":{"0":"post-111270","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ieee","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/111270","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/111271"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=111270"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=111270"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=111270"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}