{"id":112225,"date":"2024-10-18T16:23:31","date_gmt":"2024-10-18T16:23:31","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-665-1995\/"},"modified":"2024-10-24T22:04:10","modified_gmt":"2024-10-24T22:04:10","slug":"ieee-665-1995","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-665-1995\/","title":{"rendered":"IEEE 665 1995"},"content":{"rendered":"
Revision Standard – Inactive – Withdrawn. Grounding practices that have generally been accepted by the electric utility industry as contributing to effective grounding systems for personnel safety and equipment protection in generating stations are identified. A guide for the design of generating station grounding systems and for grounding practices applied to generating station indoor and outdoor structures and equipment, including the interconnection of the station and substation grounding systems, is provided.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | Title Page <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | Introduction Participants <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | CONTENTS <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | 1. Overview 2. References <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 3. Definitions <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 4. Design objectives 4.1 Neutral ground, equipment ground, and safety ground 4.2 Station grounding system <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 4.3 Preventing the transfer of high ground voltages 4.4 Design objectives <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 5. Detailed design considerations 5.1 Grounding principles 5.2 Ground grid design <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 5.3 Generator and isolated phase bus grounding <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 5.4 Grounding of buildings, fences, and structures <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | 5.5 Grounding of generating station auxiliaries <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | 5.6 Lightning protection for generating station structures <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | 5.7 Grounding of buried structures <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | 5.8 Sizing of grounding conductors <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | 6. Bibliography <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | Annex A\u2014Determination of the k factor <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | Annex B\u2014Corrosion <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | Annex C\u2014Division of current for small interior grids <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" IEEE Guide for Generating Station Grounding<\/b><\/p>\n |