{"id":112997,"date":"2024-10-18T16:41:39","date_gmt":"2024-10-18T16:41:39","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/nfpa-hdbk-13-2013\/"},"modified":"2024-10-24T22:06:47","modified_gmt":"2024-10-24T22:06:47","slug":"nfpa-hdbk-13-2013","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/nfpa\/nfpa-hdbk-13-2013\/","title":{"rendered":"NFPA Hdbk 13 2013"},"content":{"rendered":"

Solve sprinkler challenges with the Automatic Sprinkler Systems Handbook, the most complete reference on sprinkler design and installation ever published! Written by today\\’s foremost experts in fire sprinkler engineering, fire testing, and applications, the 2013 Automatic Sprinkler Systems Handbook is a revolutionary tool that delivers the know-how and answers needed for compliant and efficient design, installation, and testing. The 2013 NFPA 13 Handbook offers a groundbreaking level of support. The 2013 edition of NFPA 13 is current with the latest sprinkler technology, delivering scientifically-based solutions that reduce risks and fire loss — and only the Automatic Sprinkler Systems Handbook contains detailed explanations of NFPA 13 provisions, real-world visuals, and a wealth of “extra” material not in the Standard itself. It\\’s your source for everything on NFPA 13: The complete text of the 2013 NFPA 13: Standard for the Installation of Sprinkler Systems — with vertical rules alerting you to new text, and bullets for deletions Exclusive commentary that clarifies NFPA 13\\’s intent and rationale written by Kenneth Isman, George Laverick, David Fuller, Robert Caputo, Roland Huggins, Victoria Valentine, Dana Haagensen, Garner Palenske, Bradford Cronin, James Lake, Kerry Bell, and Matthew Klaus 300 full-color photos, graphics, and illustrations, with new drawings rendered in detail New FAQs from the AHJ\\’s perspective A new step-by-step explanation of a complete hydraulic calculation of a system, in an exclusive new Supplement written by leading authority and educator Cecil Bilbo, Jr., President at Academy of Fire Sprinkler Technology New Supplement on the evolution of storage facilities written by James Golinveaux New Supplement on technical changes in the 2013 Standard QR codes that take you online for more information Avoid errors and steer clear of issues that could compromise sprinkler operation. The 2013 Automatic Sprinkler Systems Handbook is the most essential water-based fire protection resource for engineers, designers, contractors, inspectors, insurance professionals, and AHJs<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nCover <\/td>\n<\/tr>\n
2<\/td>\nCopyright <\/td>\n<\/tr>\n
5<\/td>\nTabke of Contents <\/td>\n<\/tr>\n
11<\/td>\nPreface <\/td>\n<\/tr>\n
13<\/td>\nAcknowledgments <\/td>\n<\/tr>\n
15<\/td>\nAbout the Contributors <\/td>\n<\/tr>\n
19<\/td>\nAbout the Editor <\/td>\n<\/tr>\n
20<\/td>\nPART ONE – NFPA 13, Standard for the Installation of Sprinkler Systems, with Commentary <\/td>\n<\/tr>\n
22<\/td>\n1 Administration
1.1 Scope <\/td>\n<\/tr>\n
24<\/td>\n1.2 Purpose <\/td>\n<\/tr>\n
25<\/td>\n1.3 Application <\/td>\n<\/tr>\n
26<\/td>\n1.4 Retroactivity <\/td>\n<\/tr>\n
27<\/td>\n1.5 Equivalency
1.6 Units and Symbols <\/td>\n<\/tr>\n
29<\/td>\n1.7 New Technology <\/td>\n<\/tr>\n
32<\/td>\n2 Referenced Publications
2.1 General <\/td>\n<\/tr>\n
33<\/td>\n2.2 NFPA Publications <\/td>\n<\/tr>\n
34<\/td>\n2.3 Other Publications <\/td>\n<\/tr>\n
37<\/td>\n2.4 References for Extracts in Mandatory Sections <\/td>\n<\/tr>\n
40<\/td>\n3 Definitions
3.1 General
3.2 NFPA Offi cial Definitions <\/td>\n<\/tr>\n
43<\/td>\n3.3 General Definitions <\/td>\n<\/tr>\n
52<\/td>\n3.4 Sprinkler System Type Definitions <\/td>\n<\/tr>\n
59<\/td>\n3.5 System Component Definitions <\/td>\n<\/tr>\n
62<\/td>\n3.6 Sprinkler Definitions <\/td>\n<\/tr>\n
75<\/td>\n3.7 Construction Definitions <\/td>\n<\/tr>\n
82<\/td>\n3.8 Private Water Supply Piping Definitions <\/td>\n<\/tr>\n
86<\/td>\n3.9 Storage Definitions <\/td>\n<\/tr>\n
105<\/td>\n3.10 Marine Definitions <\/td>\n<\/tr>\n
109<\/td>\n3.11 Hanging and Bracing Definitions <\/td>\n<\/tr>\n
112<\/td>\n4 General Requirements
4.1 Level of Protection <\/td>\n<\/tr>\n
113<\/td>\n4.2 Limited Area Systems
4.3 Owner\u2019s Certifi cate <\/td>\n<\/tr>\n
115<\/td>\n4.4 Additives
4.5 Air, Nitrogen, or Other Approved Gas
4.6 Support of Nonsprinkler System Components <\/td>\n<\/tr>\n
118<\/td>\n5 Classification of Occupancies and Commodities
5.1 Classification of Occupancies <\/td>\n<\/tr>\n
119<\/td>\n5.2 Light Hazard Occupancies <\/td>\n<\/tr>\n
121<\/td>\n5.3 Ordinary Hazard Occupancies <\/td>\n<\/tr>\n
126<\/td>\n5.4 Extra Hazard Occupancies <\/td>\n<\/tr>\n
127<\/td>\n5.5 Special Occupancy Hazards <\/td>\n<\/tr>\n
128<\/td>\n5.6 Commodity Classification <\/td>\n<\/tr>\n
148<\/td>\n6 System Components and Hardware
6.1 General <\/td>\n<\/tr>\n
153<\/td>\n6.2 Sprinklers <\/td>\n<\/tr>\n
167<\/td>\n6.3 Aboveground Pipe and Tube <\/td>\n<\/tr>\n
177<\/td>\n6.4 Fittings <\/td>\n<\/tr>\n
180<\/td>\n6.5 Joining of Pipe and Fittings <\/td>\n<\/tr>\n
190<\/td>\n6.6 Hangers <\/td>\n<\/tr>\n
191<\/td>\n6.7 Valves <\/td>\n<\/tr>\n
193<\/td>\n6.8 Fire Department Connections <\/td>\n<\/tr>\n
195<\/td>\n6.9 Waterfl ow Alarm Devices <\/td>\n<\/tr>\n
199<\/td>\n6.10 Signs <\/td>\n<\/tr>\n
202<\/td>\n7 System Requirements
7.1 Wet Pipe Systems <\/td>\n<\/tr>\n
205<\/td>\n7.2 Dry Pipe Systems <\/td>\n<\/tr>\n
221<\/td>\n7.3 Preaction Systems and Deluge Systems <\/td>\n<\/tr>\n
228<\/td>\n7.4 Combined Dry Pipe and Preaction Systems for Piers, Terminals, and Wharves <\/td>\n<\/tr>\n
233<\/td>\n7.5 Multi-Cycle Systems <\/td>\n<\/tr>\n
234<\/td>\n7.6 Antifreeze Systems <\/td>\n<\/tr>\n
244<\/td>\n7.7 Automatic Sprinkler Systems with Non\u2013Fire Protection Connections <\/td>\n<\/tr>\n
246<\/td>\n7.8 Outside Sprinklers for Protection Against Exposure Fires (Exposure Protection Sprinkler Systems) <\/td>\n<\/tr>\n
252<\/td>\n7.9 Refrigerated Spaces <\/td>\n<\/tr>\n
258<\/td>\n7.10 Commercial-Type Cooking Equipment and Ventilation <\/td>\n<\/tr>\n
264<\/td>\n7.11 Additives and Coatings <\/td>\n<\/tr>\n
266<\/td>\n8 Installation Requirements
8.1 Basic Requirements <\/td>\n<\/tr>\n
270<\/td>\n8.2 System Protection Area Limitations <\/td>\n<\/tr>\n
274<\/td>\n8.3 Use of Sprinklers <\/td>\n<\/tr>\n
285<\/td>\n8.4 Application of Sprinkler Types <\/td>\n<\/tr>\n
297<\/td>\n8.5 Position, Location, Spacing, and Use of Sprinklers <\/td>\n<\/tr>\n
310<\/td>\n8.6 Standard Pendent and Upright Spray Sprinklers <\/td>\n<\/tr>\n
339<\/td>\n8.7 Sidewall Standard Spray Sprinklers <\/td>\n<\/tr>\n
350<\/td>\n8.8 Extended Coverage Upright and Pendent Spray Sprinklers <\/td>\n<\/tr>\n
362<\/td>\n8.9 Extended Coverage Sidewall Spray Sprinklers <\/td>\n<\/tr>\n
370<\/td>\n8.10 Residential Sprinklers <\/td>\n<\/tr>\n
381<\/td>\n8.11 CMSA Sprinklers <\/td>\n<\/tr>\n
389<\/td>\n8.12 Early Suppression Fast-Response Sprinklers <\/td>\n<\/tr>\n
396<\/td>\n8.13 In-Rack Sprinklers <\/td>\n<\/tr>\n
398<\/td>\n8.14 Pilot Line Detectors <\/td>\n<\/tr>\n
400<\/td>\n8.15 Special Situations <\/td>\n<\/tr>\n
432<\/td>\n8.16 Piping Installation <\/td>\n<\/tr>\n
457<\/td>\n8.17 System Attachments <\/td>\n<\/tr>\n
478<\/td>\n9 Hanging, Bracing, and Restraint of System Piping
9.1 Hangers <\/td>\n<\/tr>\n
499<\/td>\n9.2 Installation of Pipe Hangers <\/td>\n<\/tr>\n
513<\/td>\n9.3 Protection of Piping Against Damage Where Subject to Earthquakes <\/td>\n<\/tr>\n
564<\/td>\n10 Underground Piping
10.1 Piping Materials <\/td>\n<\/tr>\n
572<\/td>\n10.2 Fittings <\/td>\n<\/tr>\n
573<\/td>\n10.3 Joining of Pipe and Fittings <\/td>\n<\/tr>\n
574<\/td>\n10.4 Depth of Cover <\/td>\n<\/tr>\n
576<\/td>\n10.5 Protection Against Freezing <\/td>\n<\/tr>\n
577<\/td>\n10.6 Protection Against Damage <\/td>\n<\/tr>\n
580<\/td>\n10.7 Requirement for Laying Pipe <\/td>\n<\/tr>\n
582<\/td>\n10.8 Joint Restraint <\/td>\n<\/tr>\n
593<\/td>\n10.9 Backfi lling
10.10 Testing and Acceptance <\/td>\n<\/tr>\n
602<\/td>\n11 Design Approaches
11.1 General <\/td>\n<\/tr>\n
608<\/td>\n11.2 Occupancy Hazard Fire Control Approach for Spray Sprinklers <\/td>\n<\/tr>\n
622<\/td>\n11.3 Special Design Approaches <\/td>\n<\/tr>\n
628<\/td>\n12 General Requirements for Storage
12.1 General <\/td>\n<\/tr>\n
638<\/td>\n12.2 Hose Connections <\/td>\n<\/tr>\n
639<\/td>\n12.3 Adjacent Hazards or Design Methods <\/td>\n<\/tr>\n
641<\/td>\n12.4 Wet Pipe Systems <\/td>\n<\/tr>\n
642<\/td>\n12.5 Dry Pipe and Preaction Systems
12.6 Storage Applications <\/td>\n<\/tr>\n
649<\/td>\n12.7 Discharge Considerations <\/td>\n<\/tr>\n
654<\/td>\n12.8 Hose Stream Allowance and Water Supply Duration <\/td>\n<\/tr>\n
656<\/td>\n12.9 Restrictions <\/td>\n<\/tr>\n
660<\/td>\n12.10 Room Design Method <\/td>\n<\/tr>\n
661<\/td>\n12.11 High-Expansion Foam Systems
12.12 Protection of Idle Pallets <\/td>\n<\/tr>\n
672<\/td>\n13 Miscellaneous Storage <\/td>\n<\/tr>\n
673<\/td>\n13.1 Miscellaneous Storage Up to 12 ft (3.7 m) in Height
13.2 Design Basis <\/td>\n<\/tr>\n
677<\/td>\n13.3 In-Rack Sprinklers <\/td>\n<\/tr>\n
680<\/td>\n14 Protection for Palletized, Solid-Piled , Bin Box, Shelf, or Back-to-Back Shelf Storage of Class I through Class IV Commodities
14.1 General <\/td>\n<\/tr>\n
681<\/td>\n14.2 Control Mode Density\/Area Sprinkler Protection Criteria for Palletized, Solid-Piled, Bin Box, Shelf, or Back-to-Back Shelf Storage of Class I Through Class IV Commodities <\/td>\n<\/tr>\n
690<\/td>\n14.3 CMSA Sprinklers for Palletized or Solid-Piled Storage of Class I Through Class IV Commodities <\/td>\n<\/tr>\n
694<\/td>\n14.4 Early Suppression Fast-Response (ESFR) Sprinklers for Palletized or Solid-Piled Storage of Class I Through Class IV Commodities <\/td>\n<\/tr>\n
696<\/td>\n14.5 Special Design for Palletized, Solid- Piled, Bin Box, or Shelf Storage of Class I Through Class IV Commodities <\/td>\n<\/tr>\n
697<\/td>\n14.6 High-Expansion Foam – Reduction to Ceiling Density <\/td>\n<\/tr>\n
698<\/td>\n15 Protection for Palletized, Solid-Piled, Bin Box, Shelf, or Back-to-Back Shelf Storage of Plastic and Rubber Commodities
15.1 General <\/td>\n<\/tr>\n
699<\/td>\n15.2 Control Mode Density\/Area Sprinkler Protection Criteria for Palletized, Solid-Piled, Bin Box, Shelf, or Back-to-Back Shelf Storage of Plastic and Rubber Commodities <\/td>\n<\/tr>\n
710<\/td>\n15.3 CMSA Sprinklers for Palletized or Solid-Piled Storage of Plastic and Rubber Commodities <\/td>\n<\/tr>\n
712<\/td>\n15.4 Early Suppression Fast-Response (ESFR) Sprinklers for Palletized or Solid-Piled Storage of Plastic and Rubber Commodities <\/td>\n<\/tr>\n
717<\/td>\n15.5 High-Expansion Foam -Reduction in Ceiling Density <\/td>\n<\/tr>\n
720<\/td>\n16 Protection of Rack Storage of Class I Through Class IV Commodities
16.1 General <\/td>\n<\/tr>\n
735<\/td>\n16.2 Protection Criteria for Rack Storage of Class I Through Class IV Commodities Stored Up to and Including 25 ft (7.6 m) in Height <\/td>\n<\/tr>\n
766<\/td>\n16.3 Protection Criteria for Rack Storage of Class I Through Class IV Commodities Stored Over 25 ft (7.6 m) in Height <\/td>\n<\/tr>\n
796<\/td>\n17 Protection of Rack Storage of Plastic and Rubber Commodities
17.1 General <\/td>\n<\/tr>\n
811<\/td>\n17.2 Protection Criteria for Rack Storage of Plastics Commodities Stored Up to and Including 25 ft (7.6 m) in Height <\/td>\n<\/tr>\n
842<\/td>\n17.3 Protection Criteria for Rack Storage of Plastics Commodities Stored Over 25 ft (7.6 m) in Height <\/td>\n<\/tr>\n
862<\/td>\n18 Protection of Rubber Tire Storage
18.1 General <\/td>\n<\/tr>\n
863<\/td>\n18.2 Columns Within Rubber Tire Storage <\/td>\n<\/tr>\n
864<\/td>\n18.3 Water Supplies <\/td>\n<\/tr>\n
865<\/td>\n18.4 Ceiling Systems <\/td>\n<\/tr>\n
869<\/td>\n18.5 In-Rack Sprinkler System Requirements for Protection of Rubber Tires
18.6 Reduced-Discharge Density <\/td>\n<\/tr>\n
870<\/td>\n19 Protection of Roll Paper
19.1 Protection of Roll Paper Storage <\/td>\n<\/tr>\n
882<\/td>\n20 Special Designs of Storage Protection
20.1 General
20.2 Plastic Motor Vehicle Components <\/td>\n<\/tr>\n
883<\/td>\n20.3 Sprinkler Design Criteria for Storage and Display of Class I Through Class IV Commodities, Cartoned Nonexpanded Group A Plastics and Nonexpanded Exposed Group A Plastics in Retail Stores <\/td>\n<\/tr>\n
891<\/td>\n20.4 Protection of Baled Cotton Storage <\/td>\n<\/tr>\n
893<\/td>\n20.5 Sprinkler Protection of Carton Records Storage with Catwalk Access <\/td>\n<\/tr>\n
898<\/td>\n20.6 Compact Storage of Commodities Consisting of Paper Files, Magazines, Books, and Similar Documents in Folders and Miscellaneous Supplies with No More Than 5 Percent Plastics Up to 8 ft (2.44 m) High <\/td>\n<\/tr>\n
900<\/td>\n20.7 Protection of High Bay Records Storage <\/td>\n<\/tr>\n
904<\/td>\n21 Alternative Sprinkler System Designs for Chapters 12 Through 20 <\/td>\n<\/tr>\n
905<\/td>\n21.1 General <\/td>\n<\/tr>\n
906<\/td>\n21.2 Sprinkler Protection Criteria for Palletized, Solid-Piled, Bin Box, Shelf, or Back-to- Back Shelf Storage of Class I Through Class IV and Plastic Commodities <\/td>\n<\/tr>\n
908<\/td>\n21.3 Sprinkler Protection Criteria for Open-Frame Rack Storage of Class I Through Class IV and Plastic Commodities <\/td>\n<\/tr>\n
914<\/td>\n21.4 Hose Stream Allowance and Water Supply Duration
21.5 Minimum Obstruction Criteria <\/td>\n<\/tr>\n
918<\/td>\n22 Special Occupancy Requirements
22.1 General
22.2 Flammable and Combustible Liquids <\/td>\n<\/tr>\n
922<\/td>\n22.3 Aerosol Products <\/td>\n<\/tr>\n
924<\/td>\n22.4 Spray Application Using Flammable or Combustible Materials <\/td>\n<\/tr>\n
927<\/td>\n22.5 Solvent Extraction Plants <\/td>\n<\/tr>\n
928<\/td>\n22.6 Installation and Use of Stationary Combustion Engines and Gas Turbines <\/td>\n<\/tr>\n
929<\/td>\n22.7 Nitrate Film <\/td>\n<\/tr>\n
932<\/td>\n22.8 Laboratories Using Chemicals <\/td>\n<\/tr>\n
933<\/td>\n22.9 Oxygen-Fuel Gas Systems for Welding, Cutting, and Allied Processes
22.10 Acetylene Cylinder Charging Plants <\/td>\n<\/tr>\n
934<\/td>\n22.11 Compressed Gases and Cryogenic Fluids Code
22.12 Utility LP-Gas Plants
22.13 Production, Storage, and Handling of Liquefied Natural Gas (LNG) <\/td>\n<\/tr>\n
935<\/td>\n22.14 Protection of Information Technology Equipment
22.15 Standard on Incinerators, and Waste and Linen Handling Systems and Equipment <\/td>\n<\/tr>\n
940<\/td>\n22.16 Standard for Ovens and Furnaces <\/td>\n<\/tr>\n
941<\/td>\n22.17 Health Care Facilities Code, Hyperbaric Chambers <\/td>\n<\/tr>\n
942<\/td>\n22.18 Fixed Guideway Transit and Passenger Rail Systems <\/td>\n<\/tr>\n
943<\/td>\n22.19 Motion Picture and Television Production Studio Soundstages, Approved Production Facilities, and Production Locations
22.20 Animal Housing Facilities
22.21 Water Cooling Towers <\/td>\n<\/tr>\n
955<\/td>\n22.22 Standard for the Construction and Fire Protection of Marine Terminals, Piers, and Wharves <\/td>\n<\/tr>\n
956<\/td>\n22.23 Semiconductor Fabrication Facilities <\/td>\n<\/tr>\n
958<\/td>\n22.24 Aircraft Hangars
22.25 Airport Terminal Buildings, Fueling Ramp Drainage, and Loading Walkways <\/td>\n<\/tr>\n
959<\/td>\n22.26 Aircraft Engine Test Facilities
22.27 Advanced Light Water Reactor Electric Generating Plants <\/td>\n<\/tr>\n
964<\/td>\n22.28 Light Water Nuclear Power Plants
22.29 Hydroelectric Generating Plants [NFPA 851] <\/td>\n<\/tr>\n
965<\/td>\n22.30 Code for the Protection of Cultural Resource Properties – Museums, Libraries, and Places of Worship [NFPA 909] <\/td>\n<\/tr>\n
967<\/td>\n22.31 National Electrical Code <\/td>\n<\/tr>\n
968<\/td>\n22.32 Fire Protection of Telecommunication Facilities
22.33 Exhaust Systems for Air Conveying of Vapors, Gases, Mists, and Noncombustible Particulate Solids
22.34 Hypobaric Facilities <\/td>\n<\/tr>\n
969<\/td>\n22.35 Coal Mines <\/td>\n<\/tr>\n
971<\/td>\n22.36 Metal\/Nonmetal Mining and Metal Mineral Processing Facilities <\/td>\n<\/tr>\n
974<\/td>\n22.37 Hazardous Materials Code <\/td>\n<\/tr>\n
980<\/td>\n23 Plans and Calculations
23.1 Working Plans <\/td>\n<\/tr>\n
990<\/td>\n23.2 Water Supply Information <\/td>\n<\/tr>\n
994<\/td>\n23.3 Hydraulic Calculation Forms <\/td>\n<\/tr>\n
1012<\/td>\n23.4 Hydraulic Calculation Procedures <\/td>\n<\/tr>\n
1048<\/td>\n23.5 Pipe Schedules <\/td>\n<\/tr>\n
1055<\/td>\n23.6 Deluge Systems <\/td>\n<\/tr>\n
1056<\/td>\n23.7 Exposure Protection Sprinkler Systems <\/td>\n<\/tr>\n
1057<\/td>\n23.8 In-Rack Sprinklers <\/td>\n<\/tr>\n
1058<\/td>\n23.9 Hose Allowance <\/td>\n<\/tr>\n
1060<\/td>\n24 Water Supplies
24.1 General <\/td>\n<\/tr>\n
1066<\/td>\n24.2 Types <\/td>\n<\/tr>\n
1076<\/td>\n25 Systems Acceptance
25.1 Approval of Sprinkler Systems and Private Fire Service Mains <\/td>\n<\/tr>\n
1080<\/td>\n25.2 Acceptance Requirements <\/td>\n<\/tr>\n
1088<\/td>\n25.3 Circulating Closed Loop Systems <\/td>\n<\/tr>\n
1089<\/td>\n25.4 Instructions
25.5 Hydraulic Design Information Sign <\/td>\n<\/tr>\n
1090<\/td>\n25.6 General Information Sign <\/td>\n<\/tr>\n
1094<\/td>\n26 Marine Systems
26.1 General <\/td>\n<\/tr>\n
1099<\/td>\n26.2 System Components, Hardware, and Use <\/td>\n<\/tr>\n
1104<\/td>\n26.3 System Requirements <\/td>\n<\/tr>\n
1105<\/td>\n26.4 Installation Requirements <\/td>\n<\/tr>\n
1110<\/td>\n26.5 Design Approaches
26.6 Plans and Calculations <\/td>\n<\/tr>\n
1111<\/td>\n26.7 Water Supplies <\/td>\n<\/tr>\n
1117<\/td>\n26.8 System Acceptance
26.9 System Instructions and Maintenance <\/td>\n<\/tr>\n
1120<\/td>\n27 System Inspection, Testing, and Maintenance
27.1 General <\/td>\n<\/tr>\n
1121<\/td>\n27.2 Inactive Sprinkler Systems Abandoned in Place <\/td>\n<\/tr>\n
1124<\/td>\nAnnexes
A Explanatory Material <\/td>\n<\/tr>\n
1125<\/td>\nB Miscellaneous Topics <\/td>\n<\/tr>\n
1129<\/td>\nC Explanation of Test Data and Procedures for Rack Storage <\/td>\n<\/tr>\n
1130<\/td>\nD Sprinkler System Information from the 2012 Edition of the Life Safety Code <\/td>\n<\/tr>\n
1140<\/td>\nE Development of the Design Approach to Conform with SEI\/ASCE 7 <\/td>\n<\/tr>\n
1146<\/td>\nF Informational References <\/td>\n<\/tr>\n
1152<\/td>\nPART TWO – Supplements <\/td>\n<\/tr>\n
1154<\/td>\n1. Evolution of Storage Sprinkler Standards <\/td>\n<\/tr>\n
1164<\/td>\n2. Step-by-Step Hydraulic Calculations for a Fire Sprinkler System <\/td>\n<\/tr>\n
1190<\/td>\n3. Technical\/Substantive Changes from the 2010 to 2013 Editions of NFPA 13 <\/td>\n<\/tr>\n
1226<\/td>\nNFPA 13 Index <\/td>\n<\/tr>\n
1247<\/td>\nImportant Notices and Legal Disclaimers <\/td>\n<\/tr>\n
1248<\/td>\nTIA 13-3 <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

NFPA 13: Automatic Sprinkler Systems Handbook<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
NFPA<\/b><\/a><\/td>\n2013<\/td>\n1248<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":112998,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2638],"product_tag":[],"class_list":{"0":"post-112997","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-nfpa","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/112997","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/112998"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=112997"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=112997"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=112997"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}