{"id":118225,"date":"2024-10-19T03:52:46","date_gmt":"2024-10-19T03:52:46","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-a807-2008-2\/"},"modified":"2024-10-24T22:39:21","modified_gmt":"2024-10-24T22:39:21","slug":"astm-a807-2008-2","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-a807-2008-2\/","title":{"rendered":"ASTM-A807 2008"},"content":{"rendered":"<\/p>\n
1.1 This practice covers procedures, soils, and soil placement for the proper installation of corrugated steel structural plate pipe, pipe-arches, arches, and underpasses produced to Specification A 761 \/A 761M , in either trench or embankment installations. A typical trench installation and a typical embankment (projection) installation are shown in Figs. 1 and 2, respectively. Structural plate structures as described herein are those structures factory fabricated in plate form and bolted together on site to provide the required shape, size, and length of structure. This practice applies to structures designed in accordance with Practice A 796\/A 796M .<\/p>\n
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.<\/span><\/p>\n 1.3 The values stated in either inch-pound units or SI units shall be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system must be used independently of the other, without combining values in any way. SI units are shown in brackets in the text for clarity, but they are the applicable values when the installation is to be performed using SI units.<\/p>\n FIG. 1 Typical Trench Installation<\/span><\/p>\n FIG. 2 Typical Embankment (Projection) Installation<\/span><\/p>\n A807\/A807M-02(2008) Standard Practice for Installing Corrugated Steel Structural Plate Pipe for Sewers and Other Applications<\/b><\/p>\nPDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 1<\/td>\n Scope
Referenced Documents
Terminology <\/td>\n<\/tr>\n\n 2<\/td>\n Significance and Use
Trench Excavation
FIG. 1
FIG. 2 <\/td>\n<\/tr>\n\n 3<\/td>\n Foundation
Bedding
FIG. 3 <\/td>\n<\/tr>\n\n 4<\/td>\n Assembly
FIG. 4
FIG. 5 <\/td>\n<\/tr>\n\n 5<\/td>\n Structural Backfill Material
Shape Control
TABLE 1 <\/td>\n<\/tr>\n\n 6<\/td>\n General Placement of Structural Backfill
Regular Backfill <\/td>\n<\/tr>\n\n 7<\/td>\n Multiple Structures
Keywords <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n ASTM<\/b><\/a><\/td>\n 2008<\/td>\n 7<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":118226,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[348,2637],"product_tag":[],"class_list":{"0":"post-118225","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-23-040-15","7":"product_cat-astm","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/118225","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/118226"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=118225"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=118225"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=118225"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}