{"id":120160,"date":"2024-10-19T04:14:49","date_gmt":"2024-10-19T04:14:49","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/icc-international-fire-code-ifc-2003\/"},"modified":"2024-10-24T22:48:52","modified_gmt":"2024-10-24T22:48:52","slug":"icc-international-fire-code-ifc-2003","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/icc\/icc-international-fire-code-ifc-2003\/","title":{"rendered":"ICC International Fire Code (IFC) 2003"},"content":{"rendered":"
Topics addressed include fire department access, fire hydrants, automatic sprinkler systems, fire alarm systems, hazardous materials storage and use, and fire-safety requirements for new and existing buildings and premises.<\/p>\n
<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
2<\/td>\n | Copyright <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | Preface <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | Ordinance <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | Table Of Contents <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | Chapter 1 – Administration Section 101 – General Section 102 – Applicability <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | Section 103 – Department Of Fire Prevention Section 104 – General Authority And Responsibilities <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | Section 105 – Permits <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | Table 105.6.9 – Permit Amounts For Compressed Gases Table 105.6.11 – Permit Amounts For Cryogenic Fluids <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | Table 105.6.21 – Permit Amounts For Hazardous Materials <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | Table 105.6.21 – Continued <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | Section 106 – Inspections <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | Section 107 – Maintenance Section 108 – Board Of Appeals Section 109 – Violations <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | Section 110 – Unsafe Buildings Section 111 – Stop Work Order <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | Chapter 2 – Definitions Section 201 – General Section 202 – General Defintions <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | Chapter 3 – General Precautions Against Fire Section 301 – General Section 302 – Definitions Section 303 – Asphalt Kettles Section 304 – Combustible Waste Material <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | Section 305 – Ignition Sources Section 306 – Motion Picture And Film Screens Section 307 – Open Burning And Recreational Fires <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | Section 308 – Open Flames <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | Section 309 – Powered Industrial Trucks Section 310 – Smoking Section 311 – Vacant Premises <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | Section 312 – Vehicle Impact Protection Section 313 – Fueled Equipment Section 314 – Indoor Displays Section 315 – Miscellaneous Combustible Materials Storage <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | Chapter 4 – Emergency Planning And Preparedness Section 401 – General Section 402 – Definitions Section 403 – Public Assemblage And Events Section 404 – Fire Safety And Evacuation Plans <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | Section 405 – Emergency Evacuation Drills Table 405.2 – Fire And Evacuation Drill Frequency And Participation <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | Section 406 – Employee Training And Response Procedures Section 407 – Hazard Communication <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | Section 408 – Use And Occupancy-Related Requirements <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | Chapter 5 – Fire Service Features Section 501 – General Section 502 – Definitions Section 503 – Fire Apparatus Access Roads <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | Section 504 – Access To Building Openings And Roofs Section 505 – Premises Identification Section 506 – Key Boxes <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | Section 507 – Hazards To Fire Fighters Section 508 – Fire Protection Water Supplies <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | Section 509 – Fire Command Center Section 510 – Fire Department Access To Equipment <\/td>\n<\/tr>\n | ||||||
57<\/td>\n | Chapter 6 – Building Services And Systems Section 601 – General Section 602 – Definitions Section 603 – Fuel-Fired Appliances <\/td>\n<\/tr>\n | ||||||
59<\/td>\n | Section 604 – Emergency And Standby Power Systems <\/td>\n<\/tr>\n | ||||||
61<\/td>\n | Section 605 – Electrical Equipment, Wiring And Hazards <\/td>\n<\/tr>\n | ||||||
62<\/td>\n | Section 606 – Mechanical Refrigeration <\/td>\n<\/tr>\n | ||||||
64<\/td>\n | Section 607 – Elevator Recall And Maintenance Section 608 – Stationary Lead-Acid Battery Systems Section 609 – Valve-Regualated Lead-Acid (VRLA) Battery Systems <\/td>\n<\/tr>\n | ||||||
65<\/td>\n | Section 610 – Commercial Kitchen Hoods <\/td>\n<\/tr>\n | ||||||
67<\/td>\n | Chapter 7 – Fire-Resistance-Rated Construction Section 701 – General Section 702 – Definitions Section 703 – Fire-Resistance-Rated Construction Section 704 – Floor Openings And Shafts <\/td>\n<\/tr>\n | ||||||
68<\/td>\n | Table 704.1 – Vertical Opening Protection Required <\/td>\n<\/tr>\n | ||||||
69<\/td>\n | Chapter 8 – Interior Finish, Decorative Materials And Furnishings Section 801 – General Section 802 – Definitions Section 803 – Furnishings <\/td>\n<\/tr>\n | ||||||
71<\/td>\n | Section 804 – Decorative Vegetation Section 805 – Decorations And Trim <\/td>\n<\/tr>\n | ||||||
72<\/td>\n | Section 806 – Interior Finish And Decorative Materials <\/td>\n<\/tr>\n | ||||||
74<\/td>\n | Table 806.3 – Interior Wall And Ceiling Finish Requirements By Occupancies <\/td>\n<\/tr>\n | ||||||
75<\/td>\n | Chapter 9 – Fire Protection Systems Section 901 – General Table 901.6.1 – Fire Protection System Maintenance Standards <\/td>\n<\/tr>\n | ||||||
76<\/td>\n | Section 902 – Definitions <\/td>\n<\/tr>\n | ||||||
78<\/td>\n | Section 903 – Automatic Sprinkler Systems <\/td>\n<\/tr>\n | ||||||
79<\/td>\n | Table 903.2.4.2 – Group H-5 Sprinkler Design Criteria <\/td>\n<\/tr>\n | ||||||
81<\/td>\n | Table 903.2.13 – Additional Required Fire-Extinguishing Systems Table 903.2.13 – Continued <\/td>\n<\/tr>\n | ||||||
83<\/td>\n | Section 904 – Alternative Automatic Fire-Extinguishing Systems <\/td>\n<\/tr>\n | ||||||
86<\/td>\n | Section 905 – Standpipe Systems <\/td>\n<\/tr>\n | ||||||
88<\/td>\n | Section 906 – Portable Fire Extinguishers Table 906.1 – Additional Required Portable Fire Extinguishers <\/td>\n<\/tr>\n | ||||||
89<\/td>\n | Table 906.3(1) – Fire Extinguishers For Class A Fire Hazards Table 906.3(2) – Flammable Or Combustible Liquids With Depths Of Less Than Or Equal To 0.25-Inch Section 907 – Fire Alarm And Detection Systems <\/td>\n<\/tr>\n | ||||||
97<\/td>\n | Table 907.10.1.3 – Visable And Audible Alarms <\/td>\n<\/tr>\n | ||||||
99<\/td>\n | Section 908 – Emergency Alarm Systems Section 909 – Smoke Control Systems <\/td>\n<\/tr>\n | ||||||
100<\/td>\n | (Equation 9-1) (Equation 9-2) <\/td>\n<\/tr>\n | ||||||
101<\/td>\n | (Equation 9-3) (Equation 9-4) (Equation 9-5) (Equation 9-6) (Equation 9-7) <\/td>\n<\/tr>\n | ||||||
102<\/td>\n | (Equation 9-8) (Equation 9-9) <\/td>\n<\/tr>\n | ||||||
105<\/td>\n | Section 910 – Smoke And Heat Vents <\/td>\n<\/tr>\n | ||||||
106<\/td>\n | Table 910.3 – Requirements For Draft Curtains And Smoke And Heat Vents <\/td>\n<\/tr>\n | ||||||
107<\/td>\n | Section 911 – Explosion Control <\/td>\n<\/tr>\n | ||||||
108<\/td>\n | Table 911.1 – Explosion Control Requirements <\/td>\n<\/tr>\n | ||||||
109<\/td>\n | Section 912 – Fire Department Connections Section 913 – Fire Pumps <\/td>\n<\/tr>\n | ||||||
111<\/td>\n | Chapter 10 – Means Of Egress Section 1001 – General [B] Section 1002 – Definitions <\/td>\n<\/tr>\n | ||||||
112<\/td>\n | [B] Section 1003 – General Means Of Egress <\/td>\n<\/tr>\n | ||||||
113<\/td>\n | [B] Section 1004 – Occupant Load Table 1004.1.2 – Maximum Floor Area Allowances Per Occupant <\/td>\n<\/tr>\n | ||||||
114<\/td>\n | Table 1004.1.2 – Continued [B] Section 1005 – Egress Width Table 1005.1 – Egress Width Per Occupant Served <\/td>\n<\/tr>\n | ||||||
115<\/td>\n | [B] Section 1006 – Means Of Egress Illuminatiion [B] Section 1007 – Accessible Means Of Egress <\/td>\n<\/tr>\n | ||||||
117<\/td>\n | [B] Section 1008 – Doors, Gates And Turnstiles <\/td>\n<\/tr>\n | ||||||
118<\/td>\n | Table 1008.1.3.1 – Revolving Door Speeds <\/td>\n<\/tr>\n | ||||||
122<\/td>\n | [B] 1009 – Stairways And Handrails <\/td>\n<\/tr>\n | ||||||
124<\/td>\n | [B] Section 1010 – Ramps <\/td>\n<\/tr>\n | ||||||
125<\/td>\n | [B] Section 1011 – Exit Signs <\/td>\n<\/tr>\n | ||||||
126<\/td>\n | [B] Section 1012 – Gaurds <\/td>\n<\/tr>\n | ||||||
127<\/td>\n | [B] Section 1013 – Exit Access <\/td>\n<\/tr>\n | ||||||
128<\/td>\n | [B] Section 1014 – Exit And Exit Access Doorways <\/td>\n<\/tr>\n | ||||||
129<\/td>\n | Table 1014.1 – Spaces With One Means OF Egress <\/td>\n<\/tr>\n | ||||||
130<\/td>\n | [B] Section 1015 – Exit Access Travel Distance Table 1015.1 – Exit Access Travel Distance [B] Section 1016 – Corridors <\/td>\n<\/tr>\n | ||||||
131<\/td>\n | Table 1016.1 – Corridor Fire-Resistance Rating [B] Section 1017 – Exits <\/td>\n<\/tr>\n | ||||||
132<\/td>\n | [B] Section 1018 – Number Of Exits And Continuity Table 1018.1 – Minimum Number Of Exits For Occupant Load Table 1018.2 – Buildings With One Exit [B] Section 1019 – Vertical Exit Enclosures <\/td>\n<\/tr>\n | ||||||
134<\/td>\n | [B] Section 1020 – Exit Passageways [B] Section 1021 – Horizontal Exits <\/td>\n<\/tr>\n | ||||||
135<\/td>\n | [B] Section 1022 – Exterior Exit Ramps And Stairways <\/td>\n<\/tr>\n | ||||||
136<\/td>\n | [B] Section 1023 – Exit Discharge <\/td>\n<\/tr>\n | ||||||
137<\/td>\n | [B] Section 1024 – Assembly <\/td>\n<\/tr>\n | ||||||
138<\/td>\n | Table 1024.6.2 – Width Of Aisles For Smoke-Protected Assembly <\/td>\n<\/tr>\n | ||||||
140<\/td>\n | Table 1024.10.1 – Smoke-Protected Assembly Aisle Accessways <\/td>\n<\/tr>\n | ||||||
141<\/td>\n | [B] Section 1025 – Emergency Escape And Rescue <\/td>\n<\/tr>\n | ||||||
142<\/td>\n | Section 1026 – Means Of Egress For Existing Buildings <\/td>\n<\/tr>\n | ||||||
144<\/td>\n | Table 1026.9 – Revolving Door Speeds <\/td>\n<\/tr>\n | ||||||
146<\/td>\n | Table 1026.17.2 – Common Path, Dead-End And Travel Distance Limits (by occupancy) <\/td>\n<\/tr>\n | ||||||
147<\/td>\n | Section 1027 – Maintenance Of The Means Of Egress <\/td>\n<\/tr>\n | ||||||
149<\/td>\n | Chapter 11 – Aviation Facilities Section 1101 – General Section 1102 – Definitions Section 1103 – General Precautions Section 1104 – Aircraft Maintenance <\/td>\n<\/tr>\n | ||||||
150<\/td>\n | Section 1105 – Portable Fire Extinguishers Section 1106 – Aircraft Fueling <\/td>\n<\/tr>\n | ||||||
155<\/td>\n | Section 1107 – Helistops And Heliports <\/td>\n<\/tr>\n | ||||||
157<\/td>\n | Chapter 12 – Dry Cleaning Section 1201 – General Section 1202 – Definitions Section 1203 – Classifications Section 1204 – General Requirements <\/td>\n<\/tr>\n | ||||||
158<\/td>\n | Section 1205 – Operating Requirements (Equation 12-1) Section 1206 – Spotting And Pretreating <\/td>\n<\/tr>\n | ||||||
159<\/td>\n | Section 1207 — Dry Cleaning Systems Section 1208 – Fire Protection <\/td>\n<\/tr>\n | ||||||
161<\/td>\n | Chapter 13 – Combustible Dust-Producing Operations Section 1301 – General Section 1302 – Definitions Section 1303 – Precautions Section 1304 – Explosion Protection Table 1304.1 – Explosion Protection Standards <\/td>\n<\/tr>\n | ||||||
163<\/td>\n | Chapter 14 – Fire Safety During Construction And Demolition Section 1401 – General Section 1402 – Definitions Section 1403 – Temporary Heating Equipment Section 1404 – Precautions Against Fire Section 1405 – Flammable And Combustible Liquids <\/td>\n<\/tr>\n | ||||||
164<\/td>\n | Section 1406 – Flammable Gases Section 1407 – Explosive Materials Section 1408 – Owner’s Responsibility For Fire Protection Section 1409 – Fire Alarm Reporting Section 1410 – Access For Fire Fighting Section 1411 – Means Of Egress Section 1412 – Water Supply For Fire Protection Section 1413 – Standpipes <\/td>\n<\/tr>\n | ||||||
165<\/td>\n | Section 1414 – Automatic Sprinkler System Section 1415 – Portable Fire Extinguishers Section 1416 – Motoized Equipment Section 1417 – Safegaurding Roofing Operations <\/td>\n<\/tr>\n | ||||||
167<\/td>\n | Chapter 15 – Flammable Finishes Section 1501 – General Section 1502 – Definitions Section 1503 – Protection Of Operations <\/td>\n<\/tr>\n | ||||||
169<\/td>\n | Section 1504 – Spray Finishing <\/td>\n<\/tr>\n | ||||||
172<\/td>\n | Section 1505 – Dipping Operations <\/td>\n<\/tr>\n | ||||||
173<\/td>\n | Section 1506 – Electrostatic Apparatus <\/td>\n<\/tr>\n | ||||||
174<\/td>\n | Section 1507 – Powder Coating <\/td>\n<\/tr>\n | ||||||
175<\/td>\n | Section 1508 – Automobile Undercoating Section 1509 – Organic Peroxides And Dual-Component Coatings Section 1510 – Floor Surfacing And Finishing Operations Section 1511 – Indoor Manufacturing Of Reinforced Plastics <\/td>\n<\/tr>\n | ||||||
177<\/td>\n | Chapter 16 – Fruit And Crop Ripening Section 1601 – General Section 1602 – Definitions Section 1603 – Ethylene Gas Section 1604 – Sources Of Ignition Section 1605 – Combustible Waste Section 1606 – Ethylene Generators Section 1607 – Warning Signs <\/td>\n<\/tr>\n | ||||||
179<\/td>\n | Chapter 17 – Fumigation And Thermal Insecticidal Fogging Section 1701 – General Section 1702 – Definitions Section 1703 – Fire Safety Requirements <\/td>\n<\/tr>\n | ||||||
181<\/td>\n | Chapter 18 – Semiconductor Fabrication Facilities Section 1801 – General Section 1802 – Definitions Section 1803 – General Safety Provisions <\/td>\n<\/tr>\n | ||||||
185<\/td>\n | Section 1804 – Storage Section 1805 – Use And Handling <\/td>\n<\/tr>\n | ||||||
186<\/td>\n | Table 1804.2.1 – Quantity Limits For Hazardous Materials In A Single Fabrication Area In Group H-6 <\/td>\n<\/tr>\n | ||||||
187<\/td>\n | Table 1804.2.1 – Continued Table 1805.2.1 – Maximum Quantities Of HPM At A Workstation <\/td>\n<\/tr>\n | ||||||
189<\/td>\n | Chapter 19 – Lumber Yards And Woodworking Facilities Section 1901 – General Section 1902 – Definitions Section 1903 – General Requirements <\/td>\n<\/tr>\n | ||||||
190<\/td>\n | Section 1904 – Fire Protection Section 1905 – Plywood, Veneer And Composite Board Mills Section 1906 – Log Storage Areas Section 1907 – Storage Of Wood Chips And Hogged Material Associated With Timber And Lumber Production Facilities Section 1908 – Storage And Processing Of Wood Chips, Hogged Material, Fines, Compost And Raw Product Associated With Yard Waste And Recycling Facilities <\/td>\n<\/tr>\n | ||||||
191<\/td>\n | Section 1909 – Exterior Storage Of Finished Lumber Products <\/td>\n<\/tr>\n | ||||||
193<\/td>\n | Chapter 20 – Manufacture Of Organic Coatings Section 2001 – General Section 2002 – Definitions Section 2003 – General Precautions Section 2004 – Electrical Equipment And Protection <\/td>\n<\/tr>\n | ||||||
194<\/td>\n | Section 2005 – Process Structures Section 2006 – Process MIlls And Kettles Section 2007 – Process Piping <\/td>\n<\/tr>\n | ||||||
195<\/td>\n | Section 2008 – Raw Materials In Process Areas Section 2009 – Raw Materials And Finished Products <\/td>\n<\/tr>\n | ||||||
197<\/td>\n | Chapter 21 – Industrial Ovens Section 2101 – General Section 2102 – Definitions Section 2103 – Location Section 2104 – Fuel Piping Section 2105 – Interlocks <\/td>\n<\/tr>\n | ||||||
198<\/td>\n | Section 2106 – Fire Protection Section 2107 – Operation And Maintenance <\/td>\n<\/tr>\n | ||||||
199<\/td>\n | Chapter 22 – Motor Fuel-Dispensing Facilities And Repair Garages Section 2201 – General Section 2202 – Definitions Section 2203 – Location Of Dispensing Devices <\/td>\n<\/tr>\n | ||||||
200<\/td>\n | Section 2204 – Dispensing Operations <\/td>\n<\/tr>\n | ||||||
201<\/td>\n | Section 2205 – Operational Requirements Section 2206 – Flammable And Combustible Liquid Motor Fuel-Dispensing Facilities <\/td>\n<\/tr>\n | ||||||
202<\/td>\n | Table 2206.2.3 – Minimum Separation Requirements For Above-Ground Tanks <\/td>\n<\/tr>\n | ||||||
205<\/td>\n | Section 2207 – Liquefied Petroleum Gas Motor Fuel-Dispensing Facilities <\/td>\n<\/tr>\n | ||||||
206<\/td>\n | Section 2208 – Compressed Natural Gas Motor Fuel-Dispensing Facilities <\/td>\n<\/tr>\n | ||||||
207<\/td>\n | Table 2208.8.1.2.3 – Separation Distance For Atmospheric Venting Of CNG Section 2209 – Hydrogen Motor Fuel-Dispensing And Generation Facilities <\/td>\n<\/tr>\n | ||||||
208<\/td>\n | Table 2209.3.1 – Outdoor Maximum Separation For Gaseous Hydrogen Dispensers, Compressors, Generators And Storage Vessels <\/td>\n<\/tr>\n | ||||||
210<\/td>\n | Table 2209.5.4.2 – Vent Pipe Height And Separation Distance Versus Hydrogen Flow Rate And Vent Pipe Diameter Figure 2209.5.4.2 – Hydrogen Vent Pipe (H) Versus Distance (D) Requirements Section 2210 – Marine Motor Fuel-Dispensing Facilities <\/td>\n<\/tr>\n | ||||||
212<\/td>\n | Section 2211 – Repair Garages <\/td>\n<\/tr>\n | ||||||
215<\/td>\n | Chapter 23 – High-Piled Combustible Storage Section 2301 – General Section 2302 – Definitions <\/td>\n<\/tr>\n | ||||||
216<\/td>\n | Section 2303 – Commodity Classification <\/td>\n<\/tr>\n | ||||||
218<\/td>\n | Section 2304 – Designation Of High-Piled Storage Area Section 2305 – Housekeeping And Maintenance Section 2306 – General Fire Protection And Life Safety Features <\/td>\n<\/tr>\n | ||||||
219<\/td>\n | Figure 2303.7.4 – Mixed Commodities <\/td>\n<\/tr>\n | ||||||
220<\/td>\n | Table 2306.2 – General Fire Protection And Life Safety Requirements <\/td>\n<\/tr>\n | ||||||
222<\/td>\n | Section 2307 – Solid-Piled And Shelf Storage Section 2308 – Rack Storage Table 2308.3 – Required Flue Spaces For Rack Storage <\/td>\n<\/tr>\n | ||||||
223<\/td>\n | Section 2309 – Automated Storage Section 2310 – Specialty Storage <\/td>\n<\/tr>\n | ||||||
225<\/td>\n | Chapter 24 – Tents, Canopies And Other Membrane Structures Section 2401 – General Section 2402 – Definitions Section 2403 – Temporary Tents, Canopies And Membrane Structures <\/td>\n<\/tr>\n | ||||||
226<\/td>\n | Table 2403.12.2 – Minimum Number Of Means Of Egress And Means Of Egress Wisths From Temporary Membrane Structures, Tents And Canopies <\/td>\n<\/tr>\n | ||||||
227<\/td>\n | Section 2404 – Temporary And Permanent Tents, Canopies And Membrane Structuresz <\/td>\n<\/tr>\n | ||||||
231<\/td>\n | Chapter 25 – Tire Rebuilding And Tire Storage Section 2501 – General Section 2502 – Definitions Section 2503 – Tire Rebuilding Section 2504 – Precautions Against Fire Section 2505 – Outdoor Storage <\/td>\n<\/tr>\n | ||||||
232<\/td>\n | Section 2506 – Fire Department Access Section 2507 – Fencing Section 2508 – Fire Protection Section 2509 – Indoor Storage Arrangement <\/td>\n<\/tr>\n | ||||||
233<\/td>\n | Chapter 26 – Welding And Other Hot Work Section 2601 – General Section 2602 – Definitions Section 2603 – General Requirements <\/td>\n<\/tr>\n | ||||||
234<\/td>\n | Section 2604 – Fire Safety Requirements <\/td>\n<\/tr>\n | ||||||
235<\/td>\n | Section 2605 – Gas Welding And Cutting Section 2606 – Electric Arc Hot Work Section 2607 – Calcium Carbide Systems Section 2608 – Acetylene Generators Section 2609 – Piping Manifolds And Hose Systems For Fuel Gases And Oxygen <\/td>\n<\/tr>\n | ||||||
237<\/td>\n | Chapter 27 – Hazardous Materials – General Provisions Section 2701 – General <\/td>\n<\/tr>\n | ||||||
239<\/td>\n | Section 2702 – Definitions <\/td>\n<\/tr>\n | ||||||
241<\/td>\n | Section 2703 – General Requirements <\/td>\n<\/tr>\n | ||||||
242<\/td>\n | Table 2703.1.1(1) – Maximum Allowable Quantity Per Control Area Of Hazardous Materials Posing A Physical Hazard <\/td>\n<\/tr>\n | ||||||
243<\/td>\n | Table 2703.1.1(1) – Maximum Allowable Quantity Per Control Area Of Hazardous Materials Posing A Physical Hazard – Continued <\/td>\n<\/tr>\n | ||||||
244<\/td>\n | Table 2703.1.1(2) – Maximum Allowable Quantity Per Control Area Of Hazardous Materials Posing A Health Hazard <\/td>\n<\/tr>\n | ||||||
245<\/td>\n | Table 2703.1.1(3) – Maximum Allowable Quantity Per Control Area Of Hazardous Materials Posing A Physical Hazard In An Outdoor Control Area <\/td>\n<\/tr>\n | ||||||
246<\/td>\n | Table 2703.1.1(4) – Maximum Allowable Quantity Per Control Area Of Hazardous Materials Posing A Health Hazard In An Outdoor Control Area <\/td>\n<\/tr>\n | ||||||
249<\/td>\n | Table 2703.8.2 – Required Detached Storage <\/td>\n<\/tr>\n | ||||||
250<\/td>\n | Table 2703.8.3.2 – Design And Number Of Control Areas <\/td>\n<\/tr>\n | ||||||
253<\/td>\n | Table 2703.11.1 – Maximum Allowable Quantity Per Indoor And Outdoor Control Area Group M And S Occupancies Nonflammable Solids, Nonflammable And Noncombustible Liquids Section 2704 – Storage <\/td>\n<\/tr>\n | ||||||
255<\/td>\n | Table 2704.2.2 – Required Secondary Containment – Hazardous Material Solids And Liquids Storage <\/td>\n<\/tr>\n | ||||||
257<\/td>\n | Section 2705 – Use, Dispensing And Handling <\/td>\n<\/tr>\n | ||||||
259<\/td>\n | Table 2705.2.1.4 – Required Secondary Containment – Hazardous Material Solids And Liquids Use <\/td>\n<\/tr>\n | ||||||
261<\/td>\n | Chapter 28 – Aerosols Section 2801 – General Section 2802 – Definitions Section 2803 – Classification Of Aerosol Products Table 2803.1 – Classification Of Aerosol Products Section 2804 – Inside Storage Of Aerosol Products <\/td>\n<\/tr>\n | ||||||
262<\/td>\n | Table 2804.3.1 – Nonsegregated Storage Of Level 2 And 3 Aerosol Products In General Purpose Warehouses Table 2804.3.2 – Segregated Storage Of Level 2 And 3 Aerosol Products In General Purpose Warehouses Table 2804.3.2.2 – Segregated Storage Aisle Widths And Distance To Aisles In General Purpose Warehouses <\/td>\n<\/tr>\n | ||||||
263<\/td>\n | Table 2804.7 – Maximum Quantities Of Level 2 And 3 Aerosol Products In Retail Storage Areas Section 2805 – Outside Storage Table 2805.1 – Distance To Exposures For Outside Storage Of Level 2 And 3 Aerosol Products <\/td>\n<\/tr>\n | ||||||
264<\/td>\n | Section 2806 – Retail Display Table 2806.2 – Maximum Quantities Of Level 2 And 3 Aerosol Products In Retail Display Areaas Table 2806.3 – Maximum Storage Quantities For Storage Areas Adjacent To Retail Display Of Level 2 And Level 3 Aerosols Section 2807 – Manufacturing Facilities <\/td>\n<\/tr>\n | ||||||
265<\/td>\n | Chapter 29 – Combustible Fibers Section 2901 – General Section 2902 – Definitions Section 2903 – General Precautions Section 2904 – Loose Fiber Storage Section 2905 – Baled Storage <\/td>\n<\/tr>\n | ||||||
267<\/td>\n | Chapter 30 – Compressed Gases Section 3001 – General Section 3002 – Definitions Section 3003 – General Requirements <\/td>\n<\/tr>\n | ||||||
269<\/td>\n | Section 3004 – Storage Of Compressed Gases Section 3005 – Use And Handling Of Compressed Gases <\/td>\n<\/tr>\n | ||||||
270<\/td>\n | Section 3006 – Medical Gas Systems Section 3007 – Compressed Gases Not Otherwise Regulated <\/td>\n<\/tr>\n | ||||||
271<\/td>\n | Chapter 31 – Corrosive Materials Section 3101 – General Section 3102 – Definitions Section 3103 – General Requirements Section 3104 – Storage Section 3105 – Use <\/td>\n<\/tr>\n | ||||||
273<\/td>\n | Chapter 32 – Cryogenic fluids Section 3201 – General Section 3202 – Definitions Section 3203 – General Requirements <\/td>\n<\/tr>\n | ||||||
275<\/td>\n | Table 3203.6.1 – Separation Of Stationary Containers From Exposure Hazards Table 3203.6.2 – Separation Of Portable Containers From Exposure Hazards <\/td>\n<\/tr>\n | ||||||
276<\/td>\n | Section 3204 – Storage Section 3205 – Use And Handling <\/td>\n<\/tr>\n | ||||||
279<\/td>\n | Chapter 33 – Explosives And Fireworks Section 3301 – General <\/td>\n<\/tr>\n | ||||||
281<\/td>\n | Section 3302 – Definitions <\/td>\n<\/tr>\n | ||||||
283<\/td>\n | Section 3303 – Record Keeping And Reporting <\/td>\n<\/tr>\n | ||||||
284<\/td>\n | Section 3304 – Explosive Materials Storage And Handling Table 3304.3 – Storage Amounts And Magazine Requirements For Explosives, Explosive Materials And Fireworks, 1.3 G Maximum Allowable Quantity Per Control Area <\/td>\n<\/tr>\n | ||||||
285<\/td>\n | Table 3304.5.2(1) – Application Of Separation Distance Table <\/td>\n<\/tr>\n | ||||||
286<\/td>\n | Table 3304.5.2(2) – American Table Of Distances For Storage Of Explosives As Approved By The Institute Of Makers Of Explosives And Revised June 1991 <\/td>\n<\/tr>\n | ||||||
287<\/td>\n | Table 3304.5.2(2) – Continued <\/td>\n<\/tr>\n | ||||||
288<\/td>\n | Table 3304.5.2(2) – Continued Table 3304.5.2(3) – Table Of Distances For Buildings Containing Explosives – Division 1.3 – Mass-Fire Hazard <\/td>\n<\/tr>\n | ||||||
289<\/td>\n | Table 3304.5.2(4) – Table Of Distances For Buildings Containing Explosives – Division 1.4 <\/td>\n<\/tr>\n | ||||||
290<\/td>\n | Section 3305 – Manufacture, Assembly And Testing Of Explosives, Explosive Materials And Fireworks <\/td>\n<\/tr>\n | ||||||
291<\/td>\n | Table 3305.3 – Minimum Intraplant Separation Distances Between Barricaded Operating Buildings Containing Explosives – Division 1.1, 1.2 Or 1.5 – Mass Explosion Hazzard <\/td>\n<\/tr>\n | ||||||
293<\/td>\n | Section 3306 – Small Arms Ammunition <\/td>\n<\/tr>\n | ||||||
294<\/td>\n | Section 3307 – Blasting <\/td>\n<\/tr>\n | ||||||
295<\/td>\n | Section 3308 – Fireworks Display <\/td>\n<\/tr>\n | ||||||
297<\/td>\n | Chapter 34 – Flammable And Combustible Liquids Section 3401 – General Section 3402 – Definitions <\/td>\n<\/tr>\n | ||||||
298<\/td>\n | Section 3403 – General Requirements <\/td>\n<\/tr>\n | ||||||
299<\/td>\n | Table 3403.1.1 – Class I Electrical Equipment Locations <\/td>\n<\/tr>\n | ||||||
300<\/td>\n | Table 3403.1.1 – Continued <\/td>\n<\/tr>\n | ||||||
302<\/td>\n | Section 3404 – Storage <\/td>\n<\/tr>\n | ||||||
312<\/td>\n | Table 3404.3.4.1 – Maximum Allowable Quantity Of Flammable And Combustible Liquids In Wholesale And Retail Sales Uses Per Control Area <\/td>\n<\/tr>\n | ||||||
313<\/td>\n | Table 3404.3.6.3(1) – Maximum Storage Height In Control Area <\/td>\n<\/tr>\n | ||||||
314<\/td>\n | Table 3404.3.6.3(2) – Storage Arrangements For Palletized Or Solid-Pile Storage In Liquid Storage Rooms And Warehouses Table 3404.3.6.3.(3) – Storage Arrangements For Rack Storage In Liquid Storage Rooms And Warehouses <\/td>\n<\/tr>\n | ||||||
315<\/td>\n | Table 3404.3.6.3(4) – Automatic Sprinkler Protection For Solid-Pile And Paletized Storage Of Liquids In Containers And Portable Tanks <\/td>\n<\/tr>\n | ||||||
316<\/td>\n | Table 3404.3.6.3(5) – Automatic Sprinkler Protection Requirements For Rack Storage Of Liquids In Containers Of 5-Gallon Capacity Or Less With Or Without Cartons On Conventional Wood Pallets <\/td>\n<\/tr>\n | ||||||
317<\/td>\n | Table 3404.3.6.3(6) – Automatic Sprinkler Protection Requirements For Rack Storage Of Liquids In Containers Greater Than 5-Gallon Capacity <\/td>\n<\/tr>\n | ||||||
318<\/td>\n | Table 3404.3.6.3(7) – Automatic AFFF Water Protection Requirements For Rack Storage Of Liquids In Containers Greater Than 5-Gallon Capacity Table 3404.3.6.3(8) – Automatic Sprinkler Protection Requirements For Class I Liquid Storage Of 1-Gallon Capacity Or Less With Incartoned Or Case-Cut Shelf Display Up To 6.5 Feet, And Palletized Storage Above In A Double-Row Rack Array <\/td>\n<\/tr>\n | ||||||
319<\/td>\n | Table 3404.3.7.5.1 – Automatic AFFF-Water Protection Requirements For Solid-Pile And Palletized Storage Of Liquids In Metal Contaners Of 5-Gallon Capacity Or Less <\/td>\n<\/tr>\n | ||||||
320<\/td>\n | Table 3404.4.2 – Outdoor Liquid Storage Container And Portable Tanks <\/td>\n<\/tr>\n | ||||||
321<\/td>\n | Section 3405 – Dispensing, Use, Mixing And Handling <\/td>\n<\/tr>\n | ||||||
322<\/td>\n | Table 3405.3.4(1) – Separation Of Processing Vessels From Lot Lines Table 3405.3.4(2) – Reference Table For Use With Table 3405.3.4(1) <\/td>\n<\/tr>\n | ||||||
325<\/td>\n | Table 3405.3.8.2 – Maximum Allowable Quantities For Dispensing Of Flammable And Combustible Liquids In Outdoor Control Areas <\/td>\n<\/tr>\n | ||||||
326<\/td>\n | Section 3406 – Special Operations <\/td>\n<\/tr>\n | ||||||
337<\/td>\n | Chapter 35 – Flammable Gases Section 3501 – General Section 3502 – Definitions Section 3503 – General Requirements <\/td>\n<\/tr>\n | ||||||
338<\/td>\n | Section 3504 – Storage Table 3504.2.1 – Flammable Gases Distance From Outdoor Storage Areas To Exposures Section 3505 – Use <\/td>\n<\/tr>\n | ||||||
339<\/td>\n | Chapter 36 – Flammable Solids Section 3601 – General Section 3602 – Definitions Section 3603 – General Requirements Section 3604 – Storage Section 3605 – Use Section 3606 – Magnesium <\/td>\n<\/tr>\n | ||||||
343<\/td>\n | Chapter 37 – Highly Toxic And Toxic Materials Section 3701 – General Section 3702 – Definitions <\/td>\n<\/tr>\n | ||||||
344<\/td>\n | Section 3703 – Highly Toxic And Toxic Solids And Liquids <\/td>\n<\/tr>\n | ||||||
345<\/td>\n | Section 3704 – Highly Toxic And Toxic Compressed Gases <\/td>\n<\/tr>\n | ||||||
347<\/td>\n | Table 3704.2.2.7.5 – Rate Of Release For Cylinders And Portable Tanks <\/td>\n<\/tr>\n | ||||||
349<\/td>\n | Section 3705 – Ozone Gas Generators <\/td>\n<\/tr>\n | ||||||
351<\/td>\n | Chapter 38 – Liquefied Petroleum Gases Section 3801 – General Section 3802 – Definitions Section 3803 – Installation Of Equipment <\/td>\n<\/tr>\n | ||||||
352<\/td>\n | Section 3804 – Location Of Containers Table 3804.3 – Location Of LP-Gas Containers <\/td>\n<\/tr>\n | ||||||
353<\/td>\n | Section 3805 – Prohibited Use Of LP-Gas Section 3806 – Dispensing And Overfilling Section 3807 – Safety Precautions And Devices Section 3808 – Fire Protection Section 3809 – Storage Of Portable LP-Gas Containers Awaiting Use Or Resale <\/td>\n<\/tr>\n | ||||||
354<\/td>\n | Table 3809.12 – Location Of Containers Awaiting Use Or Resale Stored Outside Of Buildings Section 3810 – Containers Not In Service <\/td>\n<\/tr>\n | ||||||
355<\/td>\n | Section 3811 – Parking And Garaging <\/td>\n<\/tr>\n | ||||||
357<\/td>\n | Chapter 39 – Organic Peroxides Section 3901 – General Section 3902 – Definitions Section 3903 – General Requirements Section 3904 – Storage <\/td>\n<\/tr>\n | ||||||
358<\/td>\n | Table 3904.1.2 – Organic Peroxides – Distance To Exposures From Detached Buildings Or Outdoor Storage Areas <\/td>\n<\/tr>\n | ||||||
359<\/td>\n | Table 3904..2.4 – Storage Of Organic Peroxides Section 3905 – Use <\/td>\n<\/tr>\n | ||||||
361<\/td>\n | Chapter 40 – Oxidizers Section 4001 – General Section 4002 – Definitions Section 4003 – General Requirements <\/td>\n<\/tr>\n | ||||||
362<\/td>\n | Section 4004 – Storage Table 4004.1.2 – Oxidizer Liquids And Solids – Distance From Detached Buildings And Outdoor Storage Areas To Exposures Table 4004.1.7(1) – Storage Of Class 1 Oxidizer Liquids And Solids In Combustible Containers <\/td>\n<\/tr>\n | ||||||
363<\/td>\n | Table 4004.1.7(2) – Storage Of Class 2 Oxidizer Liquids And Solids Table 4004.1.7(3) – Storage Of Class 3 Oxidizer Liquids And Solids Table 4004.2.2 – Oxidizer Gases – Distance From Storage To Exposures Section 4005 – Use <\/td>\n<\/tr>\n | ||||||
365<\/td>\n | Chapter 41 – Pyrophoric Materials Section 4101 – General Section 4102 – Definitions Section 4103 – General Requirements Section 4104 – Storage Section 4105 – Use <\/td>\n<\/tr>\n | ||||||
366<\/td>\n | Table 4104.2.1 – Pyprphoric Gases – Distance From Storage To Exposures Section 4106 – Silane Gas <\/td>\n<\/tr>\n | ||||||
369<\/td>\n | Chapter 42 – Pyroxylin (Cellulose Nitrate) Plastics Section 4201 – General Section 4202 – Definitions Section 4203 – General Requirements Section 4204 – Storage And Handling <\/td>\n<\/tr>\n | ||||||
371<\/td>\n | Chapter 43 – Unstable (Reactive) Materials Section 4301 – General Section 4302 – Definitions Section 4303 – General Requirements <\/td>\n<\/tr>\n | ||||||
372<\/td>\n | Section 4304 – Storage Section 4305 – Use <\/td>\n<\/tr>\n | ||||||
373<\/td>\n | Chapter 44 – Water-Reactive Solids And Liquids Section 4401 – General Section 4402 – Definitions Section 4403 – General Requirements Section 4404 – Storage <\/td>\n<\/tr>\n | ||||||
374<\/td>\n | Section 4405 – Use <\/td>\n<\/tr>\n | ||||||
375<\/td>\n | Chapter 45 – Referenced Standards <\/td>\n<\/tr>\n | ||||||
383<\/td>\n | Appendix A – Board Of Appeals Section A101 – General <\/td>\n<\/tr>\n | ||||||
385<\/td>\n | Appendix B – Fire-Flow Requirements For Buildings Section B101 – General Section B102 – Definitions Section B103 – Modifications Section B104 – Fire-Flow Calculation Area Section B105 – Fire-Flow Requirements For Buildings Section B106 – Referenced Standards <\/td>\n<\/tr>\n | ||||||
386<\/td>\n | Table B105.1 – Minimum Required Fire Flow And Flow Duration For Buildings <\/td>\n<\/tr>\n | ||||||
387<\/td>\n | Appendix C – Fire Hydrant Locations And Distribution Section C101 – General Section C102 – Location Section C103 – Number Of Hydrants Section C104 – Consideration Of Existing Fire Hydrants Section C105 – Distribution Of Fire Hydrants Table C105.1 – Number And Distribution Of Fire Hydrants <\/td>\n<\/tr>\n | ||||||
389<\/td>\n | Appendix D – Fire Apparatus Access Roads Section D101 – General Section D102 – Required Facilities Section D103 – Minimum Specifications Table D103.4 – Requirements For Dead-End Fire Apparatus Access Roads Figure D103.1 – Dead-End Fire Apparatus Access Road Turnaround <\/td>\n<\/tr>\n | ||||||
390<\/td>\n | Figure D103.6 – Fire Lane Signs Section D104 – Commercial And Industrial Developments Section D105 – Aerial Fire Apparatus Access Roads Section D106 – Multiple-Family Residential Developments Section D107 – One- Or Two-Family Residential Developments <\/td>\n<\/tr>\n | ||||||
393<\/td>\n | Appendix E – Hazard Categories Section E101 – General Section E102 – Hazard Categories <\/td>\n<\/tr>\n | ||||||
396<\/td>\n | Section E103 – Evaluation Of Hazards <\/td>\n<\/tr>\n | ||||||
397<\/td>\n | (Equation E-1) (Equation E-2) <\/td>\n<\/tr>\n | ||||||
398<\/td>\n | Table E103.1.3.1 – Normalization Factor <\/td>\n<\/tr>\n | ||||||
399<\/td>\n | Appendix F – Hazard Ranking Section F101 – General Section F102 – Referenced Standards <\/td>\n<\/tr>\n | ||||||
400<\/td>\n | Table F101.2 – Fire Fighter Warning Placard Designations Based On Hazard Classification Categories <\/td>\n<\/tr>\n | ||||||
401<\/td>\n | Appendix G – Cryogenic Fluids – Weight And Volume Equivalents Section G101 – General <\/td>\n<\/tr>\n | ||||||
402<\/td>\n | Table G101.2 – Weight And Volume Equivalents For Common Cryogenic Fluids <\/td>\n<\/tr>\n | ||||||
403<\/td>\n | Index <\/td>\n<\/tr>\n | ||||||
423<\/td>\n | Editorial Changes – Second Printing <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" International Fire Code<\/b><\/p>\n |