{"id":129001,"date":"2024-10-19T06:23:39","date_gmt":"2024-10-19T06:23:39","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/nfpa-86-2015\/"},"modified":"2024-10-24T23:34:08","modified_gmt":"2024-10-24T23:34:08","slug":"nfpa-86-2015","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/nfpa\/nfpa-86-2015\/","title":{"rendered":"NFPA 86 2015"},"content":{"rendered":"
Protect people and property using the latest safeguards in the 2015 NFPA 86: Standard for Ovens and Furnaces. Minimize the fire and explosion hazards that can endanger the furnace, the building, or personnel. The 2015 edition of NFPA 86: Standard for Ovens and Furnaces provides the latest comprehensive requirements for the safe design; installation; operation; and inspection, testing, and maintenance of Class A, B, C, and D ovens, dryers, and furnaces; thermal oxidizers; and any other heated enclosure used for processing of materials and related equipment. Protect industrial facilities and employees with requirements for: General approvals, plans, specifications, and safety labeling Location and construction Furnace heating systems Commissioning, operations, maintenance, inspection, and testing Safety equipment and application Major changes bring the 2015 NFPA 86 up-to-date with industry needs: Added definitions for burner management system (BMS), combustion safeguard, flame detector, flame failure response time, hardwired, and pressure regulators Added procedures for placing equipment into service based on purging practices in the 2015 NFPA 54: National Fuel Gas Code and the 2014 NFPA 56: Fire and Explosion Prevention During Cleaning and Purging of Flammable Gas Piping Systems New requirements prohibiting the manifolding of vent lines from different pressure levels Modified requirements for Class A and Class C ovens and furnaces — including the development of new requirements on fire protection and safety ventilation for Class A ovens. NFPA 86 gives industrial facility owners and operators, designers, and installers confidence in fire safety and fire protection for ovens, furnaces, dryers, thermal oxidizers, or other heated enclosure for processing of materials.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
2<\/td>\n | Important Notices and Disclaimers <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | Additional Notices and Disclaimers <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | 2.1 General 2.2 NFPA Publications <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | Chapter 1 Administration 1.1 Scope 1.2 Purpose 1.3 Application 1.4 Retroactivity <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 1.5 Equivalency 1.6 Units and Formulas Chapter 2 Referenced Publications 2.3 Other Publications 2.4 References for Extracts in Mandatory Sections <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | Chapter 3 Definitions 3.1 General 3.2 NFPA Official Definitions 3.3 General Definitions <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | Chapter 4 General 4.1 Approvals, Plans, and Specifications 4.2 Safety Labeling 4.3 Pressure Vessels Chapter 5 Location and Construction 5.1 Location <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 5.2 Furnace Design 5.3 Explosion Relief <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 5.4 Ventilation and Exhaust System 5.5 Mountings and Auxiliary Equipment <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | Chapter 6 Furnace Heating Systems 6.1 General 6.2 Fuel Gas\u2013Fired Units <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 6.3 Oil-Fired Units <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 6.4 Oxygen-Enhanced Fuel-Fired Units 6.5 Flue Product Venting 6.6 Electrically Heated Units <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 6.7 Fluid Heating Systems Chapter 7 Commissioning, Operations, Maintenance, Inspection, and Testing 7.1 Commissioning <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 7.2 Training 7.3 Operations 7.4 Inspection, Testing, and Maintenance <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | 7.5 Record Retention 7.6 Procedures Chapter 8 Safety Equipment and Application 8.1 General 8.2 Safety Device Requirements 8.3 Burner Management System Logic 8.4 Programmable Logic Controller Systems <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 8.5 Safety Control Application for Fuel-Fired Heating Systems <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 8.6 Ventilation Safety Devices 8.7 Combustion Air Safety Devices 8.8 Safety Shutoff Valves (Fuel Gas or Oil) <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | 8.9 Fuel Pressure Switches (Gas or Oil) 8.10 Flame Supervision <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | 8.11 Fuel Oil Atomization (Other Than Mechanical Atomization) 8.12 Fuel Oil Temperature Limit Devices 8.13 Multiple-Fuel Systems 8.14 Air\u2013Fuel Gas Mixing Machines 8.15 Oxygen Safety Devices <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | 8.16 Excess Temperature Limit Interlock 8.17 1400\u00b0F (760\u00b0C) Bypass Interlock 8.18 Electrical Heating Systems <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | 8.19 Fluid-Heated Systems \u2014 Excess Temperature Limit Interlock Chapter 9 Fire Protection 9.1 General 9.2 Types of Fire Protection Systems 9.3 Special Considerations 9.4 Drawings and Calculations 9.5 Means of Access 9.6 Inspection, Testing, and Maintenance of Fire Protection Equipment <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | Chapter 10 Thermal Oxidizer 10.1 General 10.2 Location and Construction 10.3 Heating Systems. (Reserved) 10.4 Commissioning, Operations, Maintenance, Inspection, and Testing. (Reserved) 10.5 Fire Protection. (Reserved) 10.6 Safety Equipment and Application <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | Chapter 11 Class A Ovens and Furnaces 11.1 General. (Reserved) 11.2 Location and Construction. (Reserved) 11.3 Heating Systems. (Reserved) 11.4 Commissioning, Operations, Maintenance, Inspection, and Testing 11.5 Fire Protection 11.6 Safety Ventilation for Class A Ovens <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | 11.7 Low-Oxygen Atmosphere Class A Ovens with Solvent Recovery <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | Chapter 12 Class B Ovens and Furnaces 12.1 General. (Reserved) 12.2 Location and Construction. (Reserved) 12.3 Heating Systems. (Reserved) 12.4 Commissioning, Operations, Maintenance, Inspection, and Testing. (Reserved) 12.5 Safety Equipment 12.6 Fire Protection. (Reserved) Chapter 13 Special Atmospheres for Class C Ovens and Furnaces 13.1 General. (Reserved) 13.2 Location and Construction. (Reserved) 13.3 Heating Systems. (Reserved) 13.4 Commissioning, Operations, Maintenance, Inspection, and Testing. (Reserved) 13.5 Safety Equipment <\/td>\n<\/tr>\n | ||||||
57<\/td>\n | 13.6 Fire Protection. (Reserved) Chapter 14 Class D Furnaces 14.1 General. (Reserved) 14.2 Location and Construction <\/td>\n<\/tr>\n | ||||||
58<\/td>\n | 14.3 Heating Systems. (Reserved) <\/td>\n<\/tr>\n | ||||||
59<\/td>\n | 14.4 Commissioning, Operations, Maintenance, Inspection, and Testing. (Reserved) 14.5 Safety Equipment <\/td>\n<\/tr>\n | ||||||
62<\/td>\n | Annex A Explanatory Material <\/td>\n<\/tr>\n | ||||||
122<\/td>\n | Annex B Example of Class A Furnace Operational and Maintenance Checklist <\/td>\n<\/tr>\n | ||||||
123<\/td>\n | Annex C Example of Class A or Class B Furnace Operational and Maintenance Checklist Annex D The Lower Limit of Flammability and the Autogenous Ignition Temperature of Certain Common Solvent Vapors Encountered in Ovens <\/td>\n<\/tr>\n | ||||||
124<\/td>\n | Annex E Continuous Solvent Vapor Concentration Indicator and Controller <\/td>\n<\/tr>\n | ||||||
125<\/td>\n | Annex F Steam Extinguishing Systems <\/td>\n<\/tr>\n | ||||||
126<\/td>\n | Annex G Example of Class C Furnace Operational and Maintenance Checklist <\/td>\n<\/tr>\n | ||||||
127<\/td>\n | Annex H Vacuum Furnace Maintenance Checklist <\/td>\n<\/tr>\n | ||||||
129<\/td>\n | Annex I Pump Data <\/td>\n<\/tr>\n | ||||||
130<\/td>\n | Annex J Engineering Data <\/td>\n<\/tr>\n | ||||||
134<\/td>\n | Annex K Vacuum Symbols <\/td>\n<\/tr>\n | ||||||
137<\/td>\n | Annex L Design Standard References Annex M Informational References <\/td>\n<\/tr>\n | ||||||
139<\/td>\n | Index <\/td>\n<\/tr>\n | ||||||
145<\/td>\n | Formal Interpretation <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" NFPA 86: Standard for Ovens and Furnaces<\/b><\/p>\n |