{"id":129627,"date":"2024-10-19T06:33:57","date_gmt":"2024-10-19T06:33:57","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ashrae-standard-140-2014\/"},"modified":"2024-10-24T23:36:11","modified_gmt":"2024-10-24T23:36:11","slug":"ashrae-standard-140-2014","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ashrae\/ashrae-standard-140-2014\/","title":{"rendered":"ASHRAE Standard 140 2014"},"content":{"rendered":"

Standard 140 specifies a standard method of test for evaluating the technical capabilities and applicability of software used in calculating the thermal performance of buildings and their HVAC systems. These test procedures can be used to identify and diagnose predictive differences from whole-building energy simulation software that may be caused by algorithmic differences, modeling limitations, input differences, coding errors, or documentation errors. The current set of tests focuses on building thermal envelope and fabric loads and HVAC equipment performance and includes comparative tests, in which a program’s results may be compared to a different version of itself or to the results of other programs, and analytical verification tests, in which a program’s results may be compared to analytical, quasi-analytical, or verified numerical model solutions. This procedure tests software over a broad range of parametric interactions and for a number of different output types, thus minimizing the concealment of algorithmic differences by compensating errors. Different building energy simulation programs, representing different degrees of modeling complexity, can be tested. However, some of the tests may be incompatible with some building energy simulation programs. The revised 2014 edition of Standard 140 includes all the test cases of Standard 140-2011 and adds a set of analytical verification test cases for evaluating models of ground-coupled heat transfer related to slab-on-grade floor construction. The 2014 edition also includes online access to electronic supporting files. The following software may be required to view some files: Microsoft Windows\u00c2\u00ae ? Microsoft Word\u00c2\u00ae ? Microsoft Excel\u00c2\u00ae ? Microsoft Notepad\u00c2\u00ae ? Adobe Reader\u00c2\u00ae Keywords: Building Energy Analysis; Method of Test; Test; Computer Programs<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nANSI\/ASHRAE Standard 140-2014 <\/td>\n<\/tr>\n
3<\/td>\nCONTENTS <\/td>\n<\/tr>\n
6<\/td>\nFOREWORD <\/td>\n<\/tr>\n
8<\/td>\nSUPPORTING FILES <\/td>\n<\/tr>\n
9<\/td>\n1. PURPOSE
2. SCOPE
3. DEFINITIONS, ABBREVIATIONS, AND ACRONYMS <\/td>\n<\/tr>\n
15<\/td>\n4. METHODS OF TESTING <\/td>\n<\/tr>\n
19<\/td>\n5. CLASS I TEST PROCEDURES <\/td>\n<\/tr>\n
87<\/td>\n6. CLASS I OUTPUT REQUIREMENTS <\/td>\n<\/tr>\n
93<\/td>\n7. CLASS II TEST PROCEDURES <\/td>\n<\/tr>\n
168<\/td>\n8. CLASS II OUTPUT REQUIREMENTS <\/td>\n<\/tr>\n
170<\/td>\nNORMATIVE ANNEX A1\u2014WEATHER DATA <\/td>\n<\/tr>\n
188<\/td>\nNORMATIVE ANNEX A2\u2014STANDARD OUTPUT REPORTS <\/td>\n<\/tr>\n
196<\/td>\nINFORMATIVE ANNEX B1\u2014TABULAR SUMMARY OF TEST CASES <\/td>\n<\/tr>\n
206<\/td>\nINFORMATIVE ANNEX B2\u2014ABOUT TYPICAL METEOROLOGICAL YEAR (TMY) WEATHER DATA <\/td>\n<\/tr>\n
207<\/td>\nINFORMATIVE ANNEX B3\u2014INFILTRATION AND FAN ADJUSTMENTS FOR ALTITUDE <\/td>\n<\/tr>\n
209<\/td>\nINFORMATIVE ANNEX B4\u2014EXTERIOR COMBINED RADIATIVE AND CONVECTIVE SURFACE COEFFICIENTS <\/td>\n<\/tr>\n
210<\/td>\nINFORMATIVE ANNEX B5\u2014INFRARED PORTION OF FILM COEFFICIENTS <\/td>\n<\/tr>\n
212<\/td>\nINFORMATIVE ANNEX B6\u2014INCIDENT ANGLE-DEPENDENT WINDOW OPTICAL PROPERTY CALCULATIONS <\/td>\n<\/tr>\n
215<\/td>\nINFORMATIVE ANNEX B7\u2014DETAILED CALCULATION OF SOLAR FRACTIONS <\/td>\n<\/tr>\n
220<\/td>\nINFORMATIVE ANNEX B8\u2014EXAMPLE RESULTS FOR BUILDING THERMAL ENVELOPE AND FABRIC LOAD AND GROUND-COUPLED SLAB-ON-GRADE TESTS OF SECTION 5.2 <\/td>\n<\/tr>\n
228<\/td>\nINFORMATIVE ANNEX B9\u2014DIAGNOSING THE RESULTS USING THE FLOW DIAGRAMS <\/td>\n<\/tr>\n
238<\/td>\nINFORMATIVE ANNEX B10\u2014INSTRUCTIONS FOR WORKING WITH RESULTS SPREADSHEETS PROVIDED WITH THE STANDARD <\/td>\n<\/tr>\n
244<\/td>\nINFORMATIVE ANNEX B11\u2014PRODUCTION OF EXAMPLE RESULTS FOR BUILDING THERMAL ENVELOPE AND FABRIC LOAD AND GROUND-COUPLED SLAB-ON-GRADE TESTS OF SECTION 5.2 <\/td>\n<\/tr>\n
249<\/td>\nINFORMATIVE ANNEX B12\u2014TEMPERATURE BIN CONVERSION PROGRAM <\/td>\n<\/tr>\n
250<\/td>\nINFORMATIVE ANNEX B13\u2014COP DEGRADATION FACTOR (CDF) AS A FUNCTION OF PART-LOAD RATIO (PLR) <\/td>\n<\/tr>\n
253<\/td>\nINFORMATIVE ANNEX B14\u2014COOLING-COIL BYPASS FACTOR <\/td>\n<\/tr>\n
256<\/td>\nINFORMATIVE ANNEX B15\u2014INDOOR FAN DATA EQUIVALENCE <\/td>\n<\/tr>\n
257<\/td>\nINFORMATIVE ANNEX B16\u2014ANALYTICAL AND QUASI-ANALYTICAL SOLUTION RESULTS AND EXAMPLE SIMULATION RESULTS FOR HVAC EQUIPMENT PERFORMANCE TESTS OF SECTIONS 5.3 AND 5.4 <\/td>\n<\/tr>\n
265<\/td>\nINFORMATIVE ANNEX B17\u2014PRODUCTION OF ANALYTICAL SOLUTION RESULTS AND EXAMPLE SIMULATION RESULTS FOR HVAC EQUIPMENT PERFORMANCE TESTS OF SECTIONS 5.3 AND 5.4 <\/td>\n<\/tr>\n
277<\/td>\nINFORMATIVE ANNEX B18\u2014ALTERNATIVE SECTION 7 GROUND COUPLING ANALYSIS CASE DESCRIPTIONS FOR DEVELOPING ADDITIONAL EXAMPLE RESULTS FOR CASES L302B, L304B, AND L324B <\/td>\n<\/tr>\n
281<\/td>\nINFORMATIVE ANNEX B19\u2014DISTRIBUTION OF SOLAR RADIATION IN THE SECTION 7 PASSIVE SOLAR BASE CASE (P100A) <\/td>\n<\/tr>\n
283<\/td>\nINFORMATIVE ANNEX B20\u2014EXAMPLE RESULTS FOR SECTION 7 TEST PROCEDURES <\/td>\n<\/tr>\n
287<\/td>\nINFORMATIVE ANNEX B21\u2014PRODUCTION OF EXAMPLE RESULTS FOR SECTION 7 TEST PROCEDURES <\/td>\n<\/tr>\n
288<\/td>\nINFORMATIVE ANNEX B22\u2014EXAMPLE PROCEDURES FOR DEVELOPING ACCEPTANCE-RANGE CRITERIA FOR SECTION 7 TEST CASES <\/td>\n<\/tr>\n
291<\/td>\nINFORMATIVE ANNEX B23\u2014VALIDATION METHODOLOGIES AND OTHER RESEARCH RELEVANT TO STANDARD 140 <\/td>\n<\/tr>\n
298<\/td>\nINFORMATIVE ANNEX B24\u2014INFORMATIVE REFERENCES <\/td>\n<\/tr>\n
302<\/td>\nINFORMATIVE ANNEX C\u2014ADDENDA DESCRIPTION INFORMATION <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

ASHRAE Standard 140-2014 – Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs (ANSI Approved)<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ASHRAE<\/b><\/a><\/td>\n2014<\/td>\n306<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":129628,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2719],"product_tag":[],"class_list":{"0":"post-129627","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ashrae","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/129627","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/129628"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=129627"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=129627"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=129627"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}