{"id":136096,"date":"2024-10-19T07:51:00","date_gmt":"2024-10-19T07:51:00","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/va-fire-code-2012-2ndedition\/"},"modified":"2024-10-25T00:01:12","modified_gmt":"2024-10-25T00:01:12","slug":"va-fire-code-2012-2ndedition","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/va\/va-fire-code-2012-2ndedition\/","title":{"rendered":"VA Fire Code 2012 2ndEdition"},"content":{"rendered":"

This is a fully integrated code based on the 2012 International Fire Code.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\n2012 VIRGINIA STATEWIDE FIRE PREVENTION CODE <\/td>\n<\/tr>\n
2<\/td>\n2012 VIRGINIA STATEWIDE FIRE PREVENTION CODE TITLE PAGE <\/td>\n<\/tr>\n
3<\/td>\nCOPYRIGHT <\/td>\n<\/tr>\n
4<\/td>\nPREFACE <\/td>\n<\/tr>\n
6<\/td>\nTABLE OF CONTENTS <\/td>\n<\/tr>\n
14<\/td>\nPART I\u2014ADMINISTRATIVE
CHAPTER 1 ADMINISTRATION
SECTION 101 SCOPE
SECTION 102 APPLICABILITY <\/td>\n<\/tr>\n
15<\/td>\nSECTION 103 INCORPORATION BY REFERENCE
SECTION 104 ENFORCEMENT <\/td>\n<\/tr>\n
16<\/td>\nSECTION 105 ENFORCING AGENCY <\/td>\n<\/tr>\n
17<\/td>\nSECTION 106 DUTIES AND POWERS OF THE FIRE OFFICIAL
SECTION 107 PERMITS AND FEES <\/td>\n<\/tr>\n
18<\/td>\nTABLE 107.2 OPERATIONAL PERMIT REQUIREMENTS (to be filled in by local jurisdiction) <\/td>\n<\/tr>\n
19<\/td>\nTABLE 107.2\u2014continued OPERATIONAL PERMIT REQUIREMENTS (to be filled in by local jurisdiction) <\/td>\n<\/tr>\n
20<\/td>\nTABLE 107.2\u2014continued OPERATIONAL PERMIT REQUIREMENTS (to be filled in by local jurisdiction) <\/td>\n<\/tr>\n
21<\/td>\nTABLE 107.2\u2014continued OPERATIONAL PERMIT REQUIREMENTS (to be filled in by local jurisdiction) <\/td>\n<\/tr>\n
22<\/td>\nTABLE 107.2\u2014continued OPERATIONAL PERMIT REQUIREMENTS (to be filled in by local jurisdiction) <\/td>\n<\/tr>\n
24<\/td>\nSECTION 108 OPERATIONAL PERMITS <\/td>\n<\/tr>\n
26<\/td>\nSECTION 109 INSPECTION
SECTION 110 UNSAFE CONDITIONS <\/td>\n<\/tr>\n
27<\/td>\nSECTION 111 VIOLATIONS
SECTION 112 APPEALS <\/td>\n<\/tr>\n
30<\/td>\nCHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 GENERAL DEFINITIONS <\/td>\n<\/tr>\n
62<\/td>\nPART II\u2014GENERAL SAFETY PROVISIONS
CHAPTER 3 GENERAL REQUIREMENTS
SECTION 301 GENERAL
SECTION 302 DEFINITIONS
SECTION 303 ASPHALT KETTLES
SECTION 304 COMBUSTIBLE WASTE MATERIAL <\/td>\n<\/tr>\n
63<\/td>\nSECTION 305 IGNITION SOURCES
SECTION 306 MOTION PICTURE PROJECTION ROOMS AND FILM <\/td>\n<\/tr>\n
64<\/td>\nSECTION 307 OPEN BURNING, RECREATIONAL FIRES AND PORTABLE OUTDOOR FIREPLACES
SECTION 308 OPEN FLAMES <\/td>\n<\/tr>\n
66<\/td>\nSECTION 309 POWERED INDUSTRIAL TRUCKS AND EQUIPMENT
SECTION 310 SMOKING <\/td>\n<\/tr>\n
67<\/td>\nSECTION 311 VACANT PREMISES <\/td>\n<\/tr>\n
68<\/td>\nSECTION 312 VEHICLE IMPACT PROTECTION
SECTION 313 FUELED EQUIPMENT
SECTION 314 INDOOR DISPLAYS <\/td>\n<\/tr>\n
69<\/td>\nSECTION 315 GENERAL STORAGE
SECTION 316 HAZARDS TO FIRE FIGHTERS <\/td>\n<\/tr>\n
70<\/td>\nSECTION 317 ROOFTOP GARDENS AND LANDSCAPED ROOFS
SECTION 318 LAUNDRY CARTS <\/td>\n<\/tr>\n
72<\/td>\nCHAPTER 4 EMERGENCY PLANNING AND PREPAREDNESS
SECTION 401 GENERAL
SECTION 402 DEFINITIONS
SECTION 403 EMERGENCY PREPAREDNESS REQUIREMENTS <\/td>\n<\/tr>\n
76<\/td>\nSECTION 404 FIRE SAFETY, EVACUATION AND LOCKDOWN PLANS <\/td>\n<\/tr>\n
77<\/td>\nSECTION 405 EMERGENCY EVACUATION DRILLS <\/td>\n<\/tr>\n
78<\/td>\nTABLE 405.2 FIRE AND EVACUATION DRILL FREQUENCY AND PARTICIPATION
SECTION 406 EMPLOYEE TRAINING AND RESPONSE PROCEDURES <\/td>\n<\/tr>\n
79<\/td>\nSECTION 407 HAZARD COMMUNICATION
SECTION 408 USE AND OCCUPANCY-RELATED REQUIREMENTS <\/td>\n<\/tr>\n
80<\/td>\nPART III\u2014BUILDING AND EQUIPMENT DESIGN FEATURES
CHAPTER 5 FIRE SERVICE FEATURES
SECTION 501 GENERAL
SECTION 502 DEFINITIONS
SECTION 503 FIRE APPARATUS ACCESS ROADS <\/td>\n<\/tr>\n
81<\/td>\nSECTION 504 ACCESS TO BUILDING OPENINGS AND ROOFS <\/td>\n<\/tr>\n
82<\/td>\nSECTION 505 PREMISES IDENTIFICATION
SECTION 506 KEY BOXES
SECTION 507 FIRE PROTECTION WATER SUPPLIES <\/td>\n<\/tr>\n
83<\/td>\nSECTION 508 FIRE COMMAND CENTER <\/td>\n<\/tr>\n
84<\/td>\nSECTION 509 FIRE PROTECTION AND UTILITY EQUIPMENT IDENTIFICATION AND ACCESS
SECTION 510 MAINTENANCE OF IN-BUILDING EMERGENCY COMMUNICATION EQUIPMENT <\/td>\n<\/tr>\n
86<\/td>\nCHAPTER 6 BUILDING SERVICES AND SYSTEMS
SECTION 601 GENERAL
SECTION 602 DEFINITIONS
SECTION 603 FUEL-FIRED APPLIANCES <\/td>\n<\/tr>\n
89<\/td>\nSECTION 604 EMERGENCY AND STANDBY POWER SYSTEMS <\/td>\n<\/tr>\n
91<\/td>\nSECTION 605 ELECTRICAL EQUIPMENT, WIRING AND HAZARDS <\/td>\n<\/tr>\n
94<\/td>\nSECTION 606 MECHANICAL REFRIGERATION <\/td>\n<\/tr>\n
96<\/td>\nSECTION 607 ELEVATOR OPERATION, MAINTENANCE AND FIRE SERVICE KEYS
SECTION 608 STATIONARY STORAGE BATTERY SYSTEMS <\/td>\n<\/tr>\n
97<\/td>\nTABLE 608.1 BATTERY REQUIREMENTS <\/td>\n<\/tr>\n
98<\/td>\nSECTION 609 COMMERCIAL KITCHEN HOODS
TABLE 609.3.3.1 COMMERCIAL COOKING SYSTEM INSPECTION FREQUENCY <\/td>\n<\/tr>\n
99<\/td>\nSECTION 610 COMMERCIAL KITCHEN COOKING OIL STORAGE <\/td>\n<\/tr>\n
100<\/td>\nCHAPTER 7 FIRE-RESISTANCE-RATED CONSTRUCTION
SECTION 701 GENERAL
SECTION 702 DEFINITIONS
SECTION 703 FIRE-RESISTANCE-RATED CONSTRUCTION <\/td>\n<\/tr>\n
101<\/td>\nSECTION 704 FLOOR OPENINGS AND SHAFTS <\/td>\n<\/tr>\n
102<\/td>\nCHAPTER 8 INTERIOR FINISH, DECORATIVE MATERIALS AND FURNISHINGS
SECTION 801 GENERAL
SECTION 802 DEFINITIONS
SECTION 803 INTERIOR WALL AND CEILING FINISH AND TRIM IN EXISTING BUILDINGS <\/td>\n<\/tr>\n
103<\/td>\nTABLE 803.3 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCYk <\/td>\n<\/tr>\n
104<\/td>\nSECTION 804 INTERIOR WALL AND CEILING TRIM AND INTERIOR FLOOR FINISH IN NEW AND EXISTING BUILDINGS <\/td>\n<\/tr>\n
105<\/td>\nSECTION 805 UPHOLSTERED FURNITURE AND MATTRESSES IN NEW AND EXISTING BUILDINGS <\/td>\n<\/tr>\n
108<\/td>\nSECTION 806 DECORATIVE VEGETATION IN NEW AND EXISTING BUILDINGS
SECTION 807 DECORATIVE MATERIALS OTHER THAN DECORATIVE VEGETATION IN NEW AND EXISTING BUILDINGS <\/td>\n<\/tr>\n
109<\/td>\nSECTION 808 FURNISHINGS OTHER THAN UPHOLSTERED FURNITURE AND MATTRESSES OR DECORATIVE MATERIALS IN NEW AND EXISTING BUILDINGS <\/td>\n<\/tr>\n
112<\/td>\nCHAPTER 9 FIRE PROTECTION SYSTEMS
SECTION 901 GENERAL <\/td>\n<\/tr>\n
113<\/td>\nTABLE 901.6.1 FIRE PROTECTION SYSTEM MAINTENANCE STANDARDS <\/td>\n<\/tr>\n
114<\/td>\nSECTION 902 DEFINITIONS <\/td>\n<\/tr>\n
115<\/td>\nSECTION 903 AUTOMATIC SPRINKLER SYSTEMS <\/td>\n<\/tr>\n
116<\/td>\nTABLE 903.2.5.2 GROUP H-5 SPRINKLER DESIGN CRITERIA <\/td>\n<\/tr>\n
118<\/td>\nTABLE 903.2.11.6 ADDITIONAL REQUIRED FIRE SUPPRESSION SYSTEMS <\/td>\n<\/tr>\n
119<\/td>\nTABLE 903.2.11.6\u2014continued ADDITIONAL REQUIRED FIRE SUPPRESSION SYSTEMS <\/td>\n<\/tr>\n
121<\/td>\nSECTION 904 ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS <\/td>\n<\/tr>\n
123<\/td>\nSECTION 905 STANDPIPE SYSTEMS <\/td>\n<\/tr>\n
126<\/td>\nSECTION 906 PORTABLE FIRE EXTINGUISHERS
TABLE 906.1 ADDITIONAL REQUIRED PORTABLE FIRE EXTINGUISHERS <\/td>\n<\/tr>\n
127<\/td>\nTABLE 906.3(1) FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS
TABLE 906.3(2) FLAMMABLE OR COMBUSTIBLE LIQUIDS WITH DEPTHS OF LESS THAN OR EQUAL TO 0.25-INCHa <\/td>\n<\/tr>\n
128<\/td>\nSECTION 907 FIRE ALARM AND DETECTION SYSTEMS <\/td>\n<\/tr>\n
137<\/td>\nTABLE 907.5.2.3.3 VISIBLE ALARMS <\/td>\n<\/tr>\n
138<\/td>\nSECTION 908 EMERGENCY ALARM SYSTEMS <\/td>\n<\/tr>\n
139<\/td>\nSECTION 909 SMOKE CONTROL SYSTEMS <\/td>\n<\/tr>\n
140<\/td>\nEQUATION 9-1
EQUATION 9-2 <\/td>\n<\/tr>\n
141<\/td>\nEQUATION 9-3 <\/td>\n<\/tr>\n
144<\/td>\nSECTION 910 SMOKE AND HEAT REMOVAL <\/td>\n<\/tr>\n
145<\/td>\nTABLE 910.3 REQUIREMENTS FOR DRAFT CURTAINS AND SMOKE AND HEAT VENTSa <\/td>\n<\/tr>\n
146<\/td>\nEQUATION 9-4
SECTION 911 EXPLOSION CONTROL <\/td>\n<\/tr>\n
147<\/td>\nTABLE 911.1 EXPLOSION CONTROL REQUIREMENTS <\/td>\n<\/tr>\n
148<\/td>\nSECTION 912 FIRE DEPARTMENT CONNECTIONS
SECTION 913 FIRE PUMPS <\/td>\n<\/tr>\n
149<\/td>\nSECTION 914 FIRE PROTECTION BASED ON SPECIAL DETAILED REQUIREMENTS OF USE AND OCCUPANCY <\/td>\n<\/tr>\n
151<\/td>\nTABLE 914.8.2 HANGAR FIRE SUPPRESSION REQUIREMENTSa,b,c <\/td>\n<\/tr>\n
154<\/td>\nCHAPTER 10 MEANS OF EGRESS
SECTION 1001 ADMINISTRATION
SECTION 1002 DEFINITIONS
SECTION 1003 GENERAL MEANS OF EGRESS <\/td>\n<\/tr>\n
156<\/td>\nSECTION 1004 OCCUPANT LOAD
TABLE 1004.1.2 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT <\/td>\n<\/tr>\n
157<\/td>\nSECTION 1005 MEANS OF EGRESS SIZING <\/td>\n<\/tr>\n
158<\/td>\nSECTION 1006 MEANS OF EGRESS ILLUMINATION
SECTION 1007 ACCESSIBLE MEANS OF EGRESS <\/td>\n<\/tr>\n
161<\/td>\nSECTION 1008 DOORS, GATES AND TURNSTILES <\/td>\n<\/tr>\n
162<\/td>\nTABLE 1008.1.4.1 REVOLVING DOOR SPEEDS <\/td>\n<\/tr>\n
167<\/td>\nSECTION 1009 STAIRWAYS <\/td>\n<\/tr>\n
171<\/td>\nSECTION 1010 RAMPS <\/td>\n<\/tr>\n
173<\/td>\nSECTION 1011 EXIT SIGNS <\/td>\n<\/tr>\n
174<\/td>\nSECTION 1012 HANDRAILS <\/td>\n<\/tr>\n
175<\/td>\nSECTION 1013 GUARDS <\/td>\n<\/tr>\n
176<\/td>\nSECTION 1014 EXIT ACCESS <\/td>\n<\/tr>\n
177<\/td>\n[B] TABLE 1014.3 COMMON PATH OF EGRESS TRAVEL
SECTION 1015 EXIT AND EXIT ACCESS DOORWAYS <\/td>\n<\/tr>\n
178<\/td>\n[B] TABLE 1015.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY
SECTION 1016 EXIT ACCESS TRAVEL DISTANCE <\/td>\n<\/tr>\n
179<\/td>\n[B] TABLE 1016.2 EXIT ACCESS TRAVEL DISTANCEa
SECTION 1017 AISLES <\/td>\n<\/tr>\n
180<\/td>\nSECTION 1018 CORRIDORS
[B] TABLE 1018.1 CORRIDOR FIRE-RESISTANCE RATING
[B] TABLE 1018.2 MINIMUM CORRIDOR WIDTH <\/td>\n<\/tr>\n
181<\/td>\nSECTION 1019 EGRESS BALCONIES
SECTION 1020 EXITS
SECTION 1021 NUMBER OF EXITS AND EXIT CONFIGURATION <\/td>\n<\/tr>\n
182<\/td>\n[B] TABLE 1021.2(1) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR R-2 OCCUPANCIES
[B] TABLE 1021.2(2) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR OTHER OCCUPANCIES <\/td>\n<\/tr>\n
183<\/td>\nSECTION 1022 INTERIOR EXIT STAIRWAYS AND RAMPS <\/td>\n<\/tr>\n
185<\/td>\nSECTION 1023 EXIT PASSAGEWAYS <\/td>\n<\/tr>\n
186<\/td>\nSECTION 1024 LUMINOUS EGRESS PATH MARKINGS <\/td>\n<\/tr>\n
187<\/td>\nSECTION 1025 HORIZONTAL EXITS <\/td>\n<\/tr>\n
188<\/td>\nSECTION 1026 EXTERIOR EXIT STAIRWAYS AND RAMPS
SECTION 1027 EXIT DISCHARGE <\/td>\n<\/tr>\n
189<\/td>\nSECTION 1028 ASSEMBLY <\/td>\n<\/tr>\n
190<\/td>\n[B] TABLE 1028.6.2 WIDTH OF AISLES FOR SMOKE-PROTECTED ASSEMBLY <\/td>\n<\/tr>\n
193<\/td>\n[B] TABLE 1028.10.2.1 SMOKE-PROTECTED ASSEMBLY AISLE ACCESSWAYS <\/td>\n<\/tr>\n
194<\/td>\nSECTION 1029 EMERGENCY ESCAPE AND RESCUE <\/td>\n<\/tr>\n
195<\/td>\nSECTION 1030 MAINTENANCE OF THE MEANS OF EGRESS <\/td>\n<\/tr>\n
196<\/td>\nCHAPTER 11 CONSTRUCTION REQUIREMENTS FOR EXISTING BUILDINGS <\/td>\n<\/tr>\n
198<\/td>\nCHAPTERS 12 through 19 RESERVED <\/td>\n<\/tr>\n
200<\/td>\nPART IV\u2014SPECIAL OCCUPANCIES AND OPERATIONS
CHAPTER 20 AVIATION FACILITIES
SECTION 2001 GENERAL
SECTION 2002 DEFINITIONS
SECTION 2003 GENERAL PRECAUTIONS
SECTION 2004 AIRCRAFT MAINTENANCE <\/td>\n<\/tr>\n
201<\/td>\nSECTION 2005 PORTABLE FIRE EXTINGUISHERS
SECTION 2006 AIRCRAFT FUELING <\/td>\n<\/tr>\n
206<\/td>\nSECTION 2007 HELISTOPS AND HELIPORTS <\/td>\n<\/tr>\n
208<\/td>\nCHAPTER 21 DRY CLEANING
SECTION 2101 GENERAL
SECTION 2102 DEFINITIONS
SECTION 2103 CLASSIFICATIONS
SECTION 2104 GENERAL REQUIREMENTS
SECTION 2105 OPERATING REQUIREMENTS <\/td>\n<\/tr>\n
209<\/td>\nEQUATION 21-1
SECTION 2106 SPOTTING AND PRETREATING <\/td>\n<\/tr>\n
210<\/td>\nSECTION 2107 DRY CLEANING SYSTEMS
SECTION 2108 FIRE PROTECTION <\/td>\n<\/tr>\n
212<\/td>\nCHAPTER 22 COMBUSTIBLE DUST-PRODUCING OPERATIONS
SECTION 2201 GENERAL
SECTION 2202 DEFINITION
SECTION 2203 PRECAUTIONS
SECTION 2204 EXPLOSION PROTECTION
TABLE 2204.1 EXPLOSION PROTECTION STANDARDS <\/td>\n<\/tr>\n
214<\/td>\nCHAPTER 23 MOTOR FUEL-DISPENSING FACILITIES AND REPAIR GARAGES
SECTION 2301 GENERAL
SECTION 2302 DEFINITIONS
SECTION 2303 LOCATION OF DISPENSING DEVICES
SECTION 2304 DISPENSING OPERATIONS <\/td>\n<\/tr>\n
215<\/td>\nSECTION 2305 OPERATIONAL REQUIREMENTS <\/td>\n<\/tr>\n
216<\/td>\nSECTION 2306 FLAMMABLE AND COMBUSTIBLE LIQUID MOTOR FUEL-DISPENSING FACILITIES <\/td>\n<\/tr>\n
217<\/td>\nTABLE 2306.2.3 MINIMUM SEPARATION REQUIREMENTS FOR ABOVE-GROUND TANKS <\/td>\n<\/tr>\n
221<\/td>\nSECTION 2307 LIQUEFIED PETROLEUM GAS MOTOR FUEL-DISPENSING FACILITIES <\/td>\n<\/tr>\n
222<\/td>\nSECTION 2308 COMPRESSED NATURAL GAS MOTOR FUEL-DISPENSING FACILITIES <\/td>\n<\/tr>\n
223<\/td>\nTABLE 2308.8.1.2.3 SEPARATION DISTANCE FOR ATMOSPHERIC VENTING OF CNG
SECTION 2309 HYDROGEN MOTOR FUEL-DISPENSING AND GENERATION FACILITIES <\/td>\n<\/tr>\n
225<\/td>\nSECTION 2310 MARINE MOTOR FUEL-DISPENSING FACILITIES <\/td>\n<\/tr>\n
226<\/td>\nSECTION 2311 REPAIR GARAGES <\/td>\n<\/tr>\n
230<\/td>\nCHAPTER 24 FLAMMABLE FINISHES
SECTION 2401 GENERAL
SECTION 2402 DEFINITIONS
SECTION 2403 PROTECTION OF OPERATIONS <\/td>\n<\/tr>\n
232<\/td>\nSECTION 2404 SPRAY FINISHING <\/td>\n<\/tr>\n
235<\/td>\nSECTION 2405 DIPPING OPERATIONS <\/td>\n<\/tr>\n
237<\/td>\nSECTION 2406 POWDER COATING
SECTION 2407 ELECTROSTATIC APPARATUS <\/td>\n<\/tr>\n
238<\/td>\nSECTION 2408 ORGANIC PEROXIDES AND DUAL-COMPONENT COATINGS <\/td>\n<\/tr>\n
239<\/td>\nSECTION 2409 INDOOR MANUFACTURING OF REINFORCED PLASTICS
SECTION 2410 FLOOR SURFACING AND FINISHING OPERATIONS <\/td>\n<\/tr>\n
240<\/td>\nCHAPTER 25 FRUIT AND CROP RIPENING
SECTION 2501 GENERAL
SECTION 2502 DEFINITIONS
SECTION 2503 ETHYLENE GAS
SECTION 2504 SOURCES OF IGNITION
SECTION 2505 COMBUSTIBLE WASTE
SECTION 2506 ETHYLENE GENERATORS
SECTION 2507 WARNING SIGNS <\/td>\n<\/tr>\n
242<\/td>\nCHAPTER 26 FUMIGATION AND INSECTICIDAL FOGGING
SECTION 2601 GENERAL
SECTION 2602 DEFINITIONS
SECTION 2603 FIRE SAFETY REQUIREMENTS <\/td>\n<\/tr>\n
244<\/td>\nCHAPTER 27 SEMICONDUCTOR FABRICATION FACILITIES
SECTION 2701 GENERAL
SECTION 2702 DEFINITIONS
SECTION 2703 GENERAL SAFETY PROVISIONS <\/td>\n<\/tr>\n
248<\/td>\nSECTION 2704 STORAGE <\/td>\n<\/tr>\n
249<\/td>\nTABLE 2704.2.2.1 QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5a <\/td>\n<\/tr>\n
250<\/td>\nTABLE 2704.2.2.1\u2014continued QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5
SECTION 2705 USE AND HANDLING <\/td>\n<\/tr>\n
251<\/td>\nTABLE 2705.2.2 MAXIMUM QUANTITIES OF HPM AT A WORKSTATIONd <\/td>\n<\/tr>\n
254<\/td>\nCHAPTER 28 LUMBER YARDS AND WOODWORKING FACILITIES
SECTION 2801 GENERAL
SECTION 2802 DEFINITIONS
SECTION 2803 GENERAL REQUIREMENTS
SECTION 2804 FIRE PROTECTION <\/td>\n<\/tr>\n
255<\/td>\nSECTION 2805 PLYWOOD, VENEER AND COMPOSITE BOARD MILLS
SECTION 2806 LOG STORAGE AREAS
SECTION 2807 STORAGE OF WOOD CHIPS AND HOGGED MATERIAL ASSOCIATED WITH TIMBER AND LUMBER PRODUCTION FACILITIES
SECTION 2808 STORAGE AND PROCESSING OF WOOD CHIPS, HOGGED MATERIAL, FINES, COMPOST AND RAW PRODUCT ASSOCIATED WITH YARD WASTE AND RECYCLING FACILITIES <\/td>\n<\/tr>\n
256<\/td>\nSECTION 2809 EXTERIOR STORAGE OF FINISHED LUMBER PRODUCTS <\/td>\n<\/tr>\n
258<\/td>\nCHAPTER 29 MANUFACTURE OF ORGANIC COATINGS
SECTION 2901 GENERAL
SECTION 2902 DEFINITION
SECTION 2903 GENERAL PRECAUTIONS
SECTION 2904 ELECTRICAL EQUIPMENT AND PROTECTION <\/td>\n<\/tr>\n
259<\/td>\nSECTION 2905 PROCESS STRUCTURES
SECTION 2906 PROCESS MILLS AND KETTLES
SECTION 2907 PROCESS PIPING
SECTION 2908 RAW MATERIALS IN PROCESS AREAS <\/td>\n<\/tr>\n
260<\/td>\nSECTION 2909 RAW MATERIALS AND FINISHED PRODUCTS <\/td>\n<\/tr>\n
262<\/td>\nCHAPTER 30 INDUSTRIAL OVENS
SECTION 3001 GENERAL
SECTION 3002 DEFINITIONS
SECTION 3003 LOCATION
SECTION 3004 FUEL PIPING
SECTION 3005 INTERLOCKS
SECTION 3006 FIRE PROTECTION
SECTION 3007 OPERATION AND MAINTENANCE <\/td>\n<\/tr>\n
264<\/td>\nCHAPTER 31 TENTS AND OTHER MEMBRANE STRUCTURES
SECTION 3101 GENERAL
SECTION 3102 DEFINITIONS
SECTION 3103 TEMPORARY TENTS AND MEMBRANE STRUCTURES <\/td>\n<\/tr>\n
265<\/td>\nTABLE 3103.12.2 MINIMUM NUMBER OF MEANS OF EGRESS AND MEANS OF EGRESS WIDTHS FROM TEMPORARY MEMBRANE STRUCTURES AND TENTS <\/td>\n<\/tr>\n
266<\/td>\nSECTION 3104 TEMPORARY AND PERMANENT TENTS AND MEMBRANE STRUCTURES <\/td>\n<\/tr>\n
270<\/td>\nCHAPTER 32 HIGH-PILED COMBUSTIBLE STORAGE
SECTION 3201 GENERAL
SECTION 3202 DEFINITIONS
SECTION 3203 COMMODITY CLASSIFICATION <\/td>\n<\/tr>\n
272<\/td>\nSECTION 3204 DESIGNATION OF HIGH-PILED STORAGE AREAS <\/td>\n<\/tr>\n
273<\/td>\nFIGURE 3203.7.4 MIXED COMMODITIESa, b <\/td>\n<\/tr>\n
274<\/td>\nSECTION 3205 HOUSEKEEPING AND MAINTENANCE
SECTION 3206 GENERAL FIRE PROTECTION AND LIFE SAFETY FEATURES <\/td>\n<\/tr>\n
275<\/td>\nTABLE 3206.2 GENERAL FIRE PROTECTION AND LIFE SAFETY REQUIREMENTS <\/td>\n<\/tr>\n
276<\/td>\nSECTION 3207 SOLID-PILED AND SHELF STORAGE
SECTION 3208 RACK STORAGE <\/td>\n<\/tr>\n
277<\/td>\nTABLE 3208.3 REQUIRED FLUE SPACES FOR RACK STORAGE
SECTION 3209 AUTOMATED STORAGE <\/td>\n<\/tr>\n
278<\/td>\nSECTION 3210 SPECIALTY STORAGE <\/td>\n<\/tr>\n
280<\/td>\nCHAPTER 33 FIRE SAFETY DURING CONSTRUCTION AND DEMOLITION
SECTION 3301 GENERAL
SECTION 3302 DEFINITIONS
SECTION 3303 TEMPORARY HEATING EQUIPMENT
SECTION 3304 PRECAUTIONS AGAINST FIRE
SECTION 3305 FLAMMABLE AND COMBUSTIBLE LIQUIDS <\/td>\n<\/tr>\n
281<\/td>\nSECTION 3306 FLAMMABLE GASES
SECTION 3307 EXPLOSIVE MATERIALS
SECTION 3308 OWNER\u2019S RESPONSIBILITY FOR FIRE PROTECTION
SECTION 3309 FIRE REPORTING
SECTION 3310 ACCESS FOR FIRE FIGHTING
SECTION 3311 MEANS OF EGRESS
SECTION 3312 WATER SUPPLY FOR FIRE PROTECTION <\/td>\n<\/tr>\n
282<\/td>\nSECTION 3313 STANDPIPES
SECTION 3314 AUTOMATIC SPRINKLER SYSTEM
SECTION 3315 PORTABLE FIRE EXTINGUISHERS
SECTION 3316 MOTORIZED CONSTRUCTION EQUIPMENT
SECTION 3317 SAFEGUARDING ROOFING OPERATIONS <\/td>\n<\/tr>\n
284<\/td>\nCHAPTER 34 TIRE REBUILDING AND TIRE STORAGE
SECTION 3401 GENERAL
SECTION 3402 DEFINITIONS
SECTION 3403 TIRE REBUILDING
SECTION 3404 PRECAUTIONS AGAINST FIRE
SECTION 3405 OUTDOOR STORAGE <\/td>\n<\/tr>\n
285<\/td>\nSECTION 3406 FIRE DEPARTMENT ACCESS
SECTION 3407 FENCING
SECTION 3408 FIRE PROTECTION
SECTION 3409 INDOOR STORAGE ARRANGEMENT <\/td>\n<\/tr>\n
286<\/td>\nCHAPTER 35 WELDING AND OTHER HOT WORK
SECTION 3501 GENERAL
SECTION 3502 DEFINITIONS
SECTION 3503 GENERAL REQUIREMENTS
SECTION 3504 FIRE SAFETY REQUIREMENTS <\/td>\n<\/tr>\n
287<\/td>\nSECTION 3505 GAS WELDING AND CUTTING <\/td>\n<\/tr>\n
288<\/td>\nSECTION 3506 ELECTRIC ARC HOT WORK
SECTION 3507 CALCIUM CARBIDE SYSTEMS
SECTION 3508 ACETYLENE GENERATORS
SECTION 3509 PIPING MANIFOLDS AND HOSE SYSTEMS FOR FUEL GASES AND OXYGEN <\/td>\n<\/tr>\n
290<\/td>\nCHAPTER 36 MARINAS
SECTION 3601 SCOPE
SECTION 3602 DEFINITIONS
SECTION 3603 GENERAL PRECAUTIONS
SECTION 3604 FIRE PROTECTION EQUIPMENT
SECTION 3605 MARINE MOTOR FUEL-DISPENSING FACILITIES <\/td>\n<\/tr>\n
292<\/td>\nCHAPTERS 37 through 49 RESERVED <\/td>\n<\/tr>\n
294<\/td>\nPART V\u2014HAZARDOUS MATERIALS
CHAPTER 50 HAZARDOUS MATERIALS\u2014GENERAL PROVISIONS
SECTION 5001 GENERAL <\/td>\n<\/tr>\n
296<\/td>\nSECTION 5002 DEFINITIONS <\/td>\n<\/tr>\n
297<\/td>\nSECTION 5003 GENERAL REQUIREMENTS <\/td>\n<\/tr>\n
299<\/td>\nTABLE 5003.1.1(1) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARDa, j, m, n, p <\/td>\n<\/tr>\n
300<\/td>\nTABLE 5003.1.1(1)\u2014continued MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARDa, j, m, n, p <\/td>\n<\/tr>\n
301<\/td>\nTABLE 5003.1.1(1)\u2014continued MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARDa, j, m, n, p <\/td>\n<\/tr>\n
302<\/td>\nTABLE 5003.1.1(2)M AXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIAL POSING A HEALTH HAZARDa, b, c, h, i <\/td>\n<\/tr>\n
303<\/td>\nTABLE 5003.1.1(3) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD IN AN OUTDOOR CONTROL AREAa, b, c, d <\/td>\n<\/tr>\n
304<\/td>\nTABLE 5003.1.1(4) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A HEALTH HAZARD IN AN OUTDOOR CONTROL AREAa, b, c, f <\/td>\n<\/tr>\n
306<\/td>\nTABLE 5003.8.2 DETACHED BUILDING REQUIRED <\/td>\n<\/tr>\n
307<\/td>\nTABLE 5003.8.3.2 DESIGN AND NUMBER OF CONTROL AREAS <\/td>\n<\/tr>\n
310<\/td>\nTABLE 5003.11.1 MAXIMUM ALLOWABLE QUANTITY PER INDOOR AND OUTDOOR CONTROL AREA IN GROUP M AND S OCCUPANCIES\u2014NONFLAMMABLE SOLIDS, NONFLAMMABLE AND NONCOMBUSTIBLE LIQUIDSd, e, f <\/td>\n<\/tr>\n
311<\/td>\nSECTION 5004 STORAGE <\/td>\n<\/tr>\n
312<\/td>\nTABLE 5004.2.2 REQUIRED SECONDARY CONTAINMENT\u2014HAZARDOUS MATERIAL SOLIDS AND LIQUIDS STORAGE <\/td>\n<\/tr>\n
314<\/td>\nSECTION 5005 USE, DISPENSING AND HANDLING <\/td>\n<\/tr>\n
316<\/td>\nTABLE 5005.2.1.4 REQUIRED SECONDARY CONTAINMENT\u2014HAZARDOUS MATERIAL LIQUIDS USE <\/td>\n<\/tr>\n
318<\/td>\nCHAPTER 51 AEROSOLS
SECTION 5101 GENERAL
SECTION 5102 DEFINITIONS
SECTION 5103 CLASSIFICATION OF AEROSOL PRODUCTS
TABLE 5103.1 CLASSIFICATION OF AEROSOL PRODUCTS
SECTION 5104 INSIDE STORAGE OF AEROSOL PRODUCTS
TABLE 5104.3.1 NONSEGREGATED STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN GENERAL PURPOSE WAREHOUSESb <\/td>\n<\/tr>\n
319<\/td>\nTABLE 5104.3.2 SEGREGATED STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN GENERAL PURPOSE WAREHOUSES
TABLE 5104.3.2.2 SEGREGATED STORAGE AISLE WIDTHS AND DISTANCE TO AISLES IN GENERAL PURPOSE WAREHOUSES <\/td>\n<\/tr>\n
320<\/td>\nTABLE 5104.7 MAXIMUM QUANTITIES OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN RETAIL STORAGE AREAS
SECTION 5105 OUTSIDE STORAGE
TABLE 5105.1 DISTANCE TO EXPOSURES FOR OUTSIDE STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS
SECTION 5106 RETAIL DISPLAY <\/td>\n<\/tr>\n
321<\/td>\nTABLE 5106.2.1 MAXIMUM QUANTITIES OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN RETAIL DISPLAY AREAS <\/td>\n<\/tr>\n
322<\/td>\nTABLE 5106.4 MAXIMUM STORAGE QUANTITIES FOR STORAGE AREAS ADJACENT TO RETAIL DISPLAY OF LEVEL 2 AND 3 AEROSOLS
SECTION 5107 MANUFACTURING FACILITIES <\/td>\n<\/tr>\n
324<\/td>\nCHAPTER 52 COMBUSTIBLE FIBERS
SECTION 5201 GENERAL
SECTION 5202 DEFINITIONS
SECTION 5203 GENERAL PRECAUTIONS
SECTION 5204 LOOSE FIBER STORAGE <\/td>\n<\/tr>\n
325<\/td>\nSECTION 5205 BALED STORAGE <\/td>\n<\/tr>\n
326<\/td>\nCHAPTER 53 COMPRESSED GASES
SECTION 5301 GENERAL
SECTION 5302 DEFINITIONS
SECTION 5303 GENERAL REQUIREMENTS <\/td>\n<\/tr>\n
329<\/td>\nSECTION 5304 STORAGE OF COMPRESSED GASES <\/td>\n<\/tr>\n
330<\/td>\nSECTION 5305 USE AND HANDLING OF COMPRESSED GASES
SECTION 5306 MEDICAL GAS SYSTEMS <\/td>\n<\/tr>\n
331<\/td>\nSECTION 5307 COMPRESSED GASES NOT OTHERWISE REGULATED <\/td>\n<\/tr>\n
332<\/td>\nCHAPTER 54 CORROSIVE MATERIALS
SECTION 5401 GENERAL
SECTION 5402 DEFINITION
SECTION 5403 GENERAL REQUIREMENTS
SECTION 5404 STORAGE
SECTION 5405 USE <\/td>\n<\/tr>\n
334<\/td>\nCHAPTER 55 CRYOGENIC FLUIDS
SECTION 5501 GENERAL
SECTION 5502 DEFINITIONS
SECTION 5503 GENERAL REQUIREMENTS <\/td>\n<\/tr>\n
336<\/td>\nSECTION 5504 STORAGE
TABLE 5504.3.1.1 SEPARATION OF STATIONARY CONTAINERS FROM EXPOSURE HAZARDS <\/td>\n<\/tr>\n
337<\/td>\nTABLE 5504.3.1.2.1 SEPARATION OF PORTABLE CONTAINERS FROM EXPOSURE HAZARDS
SECTION 5505 USE AND HANDLING <\/td>\n<\/tr>\n
340<\/td>\nCHAPTER 56 EXPLOSIVES AND FIREWORKS
SECTION 5601 GENERAL <\/td>\n<\/tr>\n
344<\/td>\nTABLE 5601.8.1(1) APPLICATION OF SEPARATION DISTANCE (Q-D) TABLES\u2014DIVISION 1.1, 1.2 AND 1.5 EXPLOSIVESa, b, c
TABLE 5601.8.1(2) APPLICATION OF SEPARATION DISTANCE (Q-D) TABLES\u2014DIVISION 1.3 EXPLOSIVESa, b, c
TABLE 5601.8.1(3) APPLICATION OF SEPARATION DISTANCE (Q-D) TABLES\u2014DIVISION 1.4 EXPLOSIVESa, b, c, d <\/td>\n<\/tr>\n
345<\/td>\nSECTION 5602 DEFINITIONS <\/td>\n<\/tr>\n
346<\/td>\nSECTION 5603 RECORD KEEPING AND REPORTING
SECTION 5604 EXPLOSIVE MATERIALS STORAGE AND HANDLING <\/td>\n<\/tr>\n
347<\/td>\nTABLE 5604.3 STORAGE AMOUNTS AND MAGAZINE REQUIREMENTS FOR EXPLOSIVES, EXPLOSIVE MATERIALS AND FIREWORKS, 1.3G MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA <\/td>\n<\/tr>\n
349<\/td>\nTABLE 5604.5.2(1) AMERICAN TABLE OF DISTANCES FOR STORAGE OF EXPLOSIVES AS APPROVED BY THE INSTITUTE OF MAKERS OF EXPLOSIVES AND REVISED JUNE 1991a <\/td>\n<\/tr>\n
350<\/td>\nTABLE 5604.5.2(1)-continued AMERICAN TABLE OF DISTANCES FOR STORAGE OF EXPLOSIVES AS APPROVED BY THE INSTITUTE OF MAKERS OF EXPLOSIVES AND REVISED JUNE 1991a <\/td>\n<\/tr>\n
351<\/td>\nTABLE 5604.5.2(2) TABLE OF DISTANCES (Q-D) FOR BUILDINGS AND MAGAZINES CONTAINING EXPLOSIVES\u2014DIVISION 1.3 MASS-FIRE HAZARDa, b, c
TABLE 5604.5.2(3) TABLE OF DISTANCES (Q-D) FOR BUILDINGS AND MAGAZINES CONTAINING EXPLOSIVES\u2014DIVISION 1.4c <\/td>\n<\/tr>\n
352<\/td>\nSECTION 5605 MANUFACTURE, ASSEMBLY AND TESTING OF EXPLOSIVES, EXPLOSIVE MATERIALS AND FIREWORKS <\/td>\n<\/tr>\n
353<\/td>\nTABLE 5605.3 MINIMUM INTRALINE (INTRAPLANT) SEPARATION DISTANCES (ILD OR IPD) BETWEEN BARRICADED OPERATING BUILDINGS CONTAINING EXPLOSIVES\u2014DIVISION 1.1, 1.2 OR 1.5 MASS-EXPLOSION HAZARDa <\/td>\n<\/tr>\n
355<\/td>\nSECTION 5606 SMALL ARMS AMMUNITION AND SMALL ARMS AMMUNITION COMPONENTS <\/td>\n<\/tr>\n
357<\/td>\nSECTION 5607 BLASTING <\/td>\n<\/tr>\n
358<\/td>\nFORM 5607.16 BLAST (SHOT) RECORD <\/td>\n<\/tr>\n
359<\/td>\nFORM 5607.16\u2014continued BLAST (SHOT) RECORD <\/td>\n<\/tr>\n
360<\/td>\nFORM 5607.16\u2014continued BLAST (SHOT) RECORD <\/td>\n<\/tr>\n
361<\/td>\nSECTION 5608 FIREWORKS DISPLAY
TABLE 5608.4 DISTANCES FOR OUTDOOR FIREWORKS DISPLAY SITES: MINIMUM SEPARATION DISTANCES FROM MORTARS TO SPECTATORS FOR LAND AND WATER DISPLAYS <\/td>\n<\/tr>\n
363<\/td>\nSECTION 5609 TEMPORARY STORAGE OF CONSUMER FIREWORKS <\/td>\n<\/tr>\n
364<\/td>\nCHAPTER 57 FLAMMABLE AND COMBUSTIBLE LIQUIDS
SECTION 5701 GENERAL
SECTION 5702 DEFINITIONS <\/td>\n<\/tr>\n
365<\/td>\nSECTION 5703 GENERAL REQUIREMENTS
TABLE 5703.6.2 PIPING STANDARDS <\/td>\n<\/tr>\n
366<\/td>\nTABLE 5703.1.1 CLASS I ELECTRICAL EQUIPMENT LOCATIONSa <\/td>\n<\/tr>\n
367<\/td>\nTABLE 5703.1.1\u2014continued CLASS I ELECTRICAL EQUIPMENT LOCATIONSa <\/td>\n<\/tr>\n
369<\/td>\nSECTION 5704 STORAGE <\/td>\n<\/tr>\n
380<\/td>\nTABLE 5704.3.4.1 MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN WHOLESALE AND RETAIL SALES OCCUPANCIESa <\/td>\n<\/tr>\n
381<\/td>\nTABLE 5704.3.6.3(1) MAXIMUM STORAGE HEIGHT IN CONTROL AREA <\/td>\n<\/tr>\n
382<\/td>\nTABLE 5704.3.6.3(2) STORAGE ARRANGEMENTS FOR PALLETIZED OR SOLID-PILE STORAGE IN LIQUID STORAGE ROOMS AND WAREHOUSES
TABLE 5704.3.6.3(3) STORAGE ARRANGEMENTS FOR RACK STORAGE IN LIQUID STORAGE ROOMS AND WAREHOUSES <\/td>\n<\/tr>\n
383<\/td>\nTABLE 5704.3.6.3(4) AUTOMATIC SPRINKLER PROTECTION FOR SOLID-PILE AND PALLETIZED STORAGE OF LIQUIDS IN METAL CONTAINERS AND PORTABLE TANKSa <\/td>\n<\/tr>\n
384<\/td>\nTABLE 5704.3.6.3(5) AUTOMATIC SPRINKLER PROTECTION REQUIREMENTS FOR RACK STORAGE OF LIQUIDS IN METAL CONTAINERS OF 5-GALLON CAPACITY OR LESS WITH OR WITHOUT CARTONS ON CONVENTIONAL WOOD PALLETSa <\/td>\n<\/tr>\n
385<\/td>\nTABLE 5704.3.6.3(6) AUTOMATIC SPRINKLER PROTECTION REQUIREMENTS OR RACK STORAGE OF LIQUIDS IN METAL CONTAINERS GREATER THAN 5-GALLON CAPACITYa <\/td>\n<\/tr>\n
386<\/td>\nTABLE 5704.3.6.3(7) AUTOMATIC AFFF WATER PROTECTION REQUIREMENTS FOR RACK STORAGE OF LIQUIDS IN METAL CONTAINERS GREATER THAN 5-GALLON CAPACITYa,b
TABLE 5704.3.6.3(8) AUTOMATIC SPRINKLER PROTECTION REQUIREMENTS FOR CLASS I LIQUID STORAGE IN METAL CONTAINERS OF 1-GALLON CAPACITY OR LESS WITH UNCARTONED OR CASE-CUT SHELF DISPLAY UP TO 6.5 FEET, AND PALLETIZED STORAGE ABOVE IN A DOUBLE-ROW RACK ARRAYa <\/td>\n<\/tr>\n
387<\/td>\nTABLE 5704.3.7.5.1 AUTOMATIC AFFF-WATER PROTECTION REQUIREMENTS FOR SOLID-PILE AND PALLETIZED STORAGE OF LIQUIDS IN METAL CONTAINERS OF 5-GALLON CAPACITY OR LESSa, b <\/td>\n<\/tr>\n
388<\/td>\nTABLE 5704.4.2 OUTDOOR LIQUID STORAGE IN CONTAINERS AND PORTABLE TANKS <\/td>\n<\/tr>\n
389<\/td>\nSECTION 5705 DISPENSING, USE, MIXING AND HANDLING <\/td>\n<\/tr>\n
390<\/td>\nTABLE 5705.3.4(1) SEPARATION OF PROCESSING VESSELS FROM LOT LINES
TABLE 5705.3.4(2) REFERENCE TABLE FOR USE WITH TABLE 5705.3.4(1) <\/td>\n<\/tr>\n
393<\/td>\nTABLE 5705.3.8.2 MAXIMUM ALLOWABLE QUANTITIES FOR DISPENSING OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN OUTDOOR CONTROL AREASa, b <\/td>\n<\/tr>\n
394<\/td>\nSECTION 5706 SPECIAL OPERATIONS <\/td>\n<\/tr>\n
406<\/td>\nCHAPTER 58 FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS
SECTION 5801 GENERAL
SECTION 5802 DEFINITIONS
SECTION 5803 GENERAL REQUIREMENTS <\/td>\n<\/tr>\n
407<\/td>\nSECTION 5804 STORAGE
SECTION 5805 USE
SECTION 5806 FLAMMABLE CRYOGENIC FLUIDS <\/td>\n<\/tr>\n
408<\/td>\nSECTION 5807 METAL HYDRIDE STORAGE SYSTEMS <\/td>\n<\/tr>\n
410<\/td>\nCHAPTER 59 FLAMMABLE SOLIDS
SECTION 5901 GENERAL
SECTION 5902 DEFINITIONS
SECTION 5903 GENERAL REQUIREMENTS
SECTION 5904 STORAGE
SECTION 5905 USE
SECTION 5906 MAGNESIUM <\/td>\n<\/tr>\n
412<\/td>\nCHAPTER 60 HIGHLY TOXIC AND TOXIC MATERIALS
SECTION 6001 GENERAL
SECTION 6002 DEFINITIONS
SECTION 6003 HIGHLY TOXIC AND TOXIC SOLIDS AND LIQUIDS <\/td>\n<\/tr>\n
413<\/td>\nSECTION 6004 HIGHLY TOXIC AND TOXIC COMPRESSED GASES <\/td>\n<\/tr>\n
415<\/td>\nTABLE 6004.2.2.7.5 RATE OF RELEASE FOR CYLINDERS AND PORTABLE TANKS <\/td>\n<\/tr>\n
417<\/td>\nSECTION 6005 OZONE GAS GENERATORS <\/td>\n<\/tr>\n
420<\/td>\nCHAPTER 61 LIQUEFIED PETROLEUM GASES
SECTION 6101 GENERAL
SECTION 6102 DEFINITIONS
SECTION 6103 INSTALLATION OF EQUIPMENT <\/td>\n<\/tr>\n
421<\/td>\nSECTION 6104 LOCATION OF LP-GAS CONTAINERS
TABLE 6104.3 LOCATION OF LP-GAS CONTAINERS <\/td>\n<\/tr>\n
422<\/td>\nSECTION 6105 PROHIBITED USE OF LP-GAS
SECTION 6106 DISPENSING AND OVERFILLING
SECTION 6107 SAFETY PRECAUTIONS AND DEVICES <\/td>\n<\/tr>\n
423<\/td>\nSECTION 6108 FIRE PROTECTION
SECTION 6109 STORAGE OF PORTABLE LP-GAS CONTAINERS AWAITING USE OR RESALE
TABLE 6109.12 SEPARATION FROM EXPOSURES OF LP-GAS CONTAINERS AWAITING USE, RESALE OR EXCHANGE STORED OUTSIDE OF BUILDINGS <\/td>\n<\/tr>\n
424<\/td>\nSECTION 6110 LP-GAS CONTAINERS NOT IN SERVICE
SECTION 6111 PARKING AND GARAGING OF LP-GAS TANK VEHICLES <\/td>\n<\/tr>\n
426<\/td>\nCHAPTER 62 ORGANIC PEROXIDES
SECTION 6201 GENERAL
SECTION 6202 DEFINITION
SECTION 6203 GENERAL REQUIREMENTS
SECTION 6204 STORAGE <\/td>\n<\/tr>\n
427<\/td>\nTABLE 6204.1.2 ORGANIC PEROXIDES\u2014DISTANCE TO EXPOSURES FROM DETACHED STORAGE BUILDINGS OR OUTDOOR STORAGE AREAS
TABLE 6204.1.7 STORAGE OF ORGANIC PEROXIDES <\/td>\n<\/tr>\n
428<\/td>\nSECTION 6205 USE <\/td>\n<\/tr>\n
430<\/td>\nCHAPTER 63 OXIDIZERS, OXIDIZING GASES AND OXIDIZING CRYOGENIC FLUIDS
SECTION 6301 GENERAL
SECTION 6302 DEFINITIONS
SECTION 6303 GENERAL REQUIREMENTS <\/td>\n<\/tr>\n
431<\/td>\nSECTION 6304 STORAGE
TABLE 6304.1.2 OXIDIZER LIQUIDS AND SOLIDS\u2014DISTANCE FROM DETACHED BUILDINGS AND OUTDOOR STORAGE AREAS TO EXPOSURES
TABLE 6304.1.7(1) STORAGE OF CLASS 1 OXIDIZER LIQUIDS AND SOLIDS IN COMBUSTIBLE CONTAINERSa <\/td>\n<\/tr>\n
432<\/td>\nTABLE 6304.1.7(2) STORAGE OF CLASS 2 OXIDIZER LIQUIDS AND SOLIDSa, b
TABLE 6304.1.7(3) STORAGE OF CLASS 3 OXIDIZER LIQUIDS AND SOLIDSa, b
TABLE 6304.1.7(4) STORAGE OF CLASS 4 OXIDIZER LIQUIDS AND SOLIDS
TABLE 6304.2.2 OXIDIZER GASES\u2014DISTANCE FROM STORAGE TO EXPOSURESa <\/td>\n<\/tr>\n
433<\/td>\nSECTION 6305 USE
SECTION 6306 LIQUID OXYGEN IN HOME HEALTH CARE <\/td>\n<\/tr>\n
436<\/td>\nCHAPTER 64 PYROPHORIC MATERIALS
SECTION 6401 GENERAL
SECTION 6402 DEFINITION
SECTION 6403 GENERAL REQUIREMENTS
SECTION 6404 STORAGE <\/td>\n<\/tr>\n
437<\/td>\nTABLE 6404.2.1 PYROPHORIC GASES\u2014DISTANCE FROM STORAGE TO EXPOSURESa
SECTION 6405 USE <\/td>\n<\/tr>\n
438<\/td>\nCHAPTER 65 PYROXYLIN (CELLULOSE NITRATE) PLASTICS
SECTION 6501 GENERAL
SECTION 6502 DEFINITIONS
SECTION 6503 GENERAL REQUIREMENTS
SECTION 6504 STORAGE AND HANDLING <\/td>\n<\/tr>\n
440<\/td>\nCHAPTER 66 UNSTABLE (REACTIVE) MATERIALS
SECTION 6601 GENERAL
SECTION 6602 DEFINITION
SECTION 6603 GENERAL REQUIREMENTS
SECTION 6604 STORAGE <\/td>\n<\/tr>\n
441<\/td>\nSECTION 6605 USE <\/td>\n<\/tr>\n
442<\/td>\nCHAPTER 67 WATER-REACTIVE SOLIDS AND LIQUIDS
SECTION 6701 GENERAL
SECTION 6702 DEFINITION
SECTION 6703 GENERAL REQUIREMENTS
SECTION 6704 STORAGE <\/td>\n<\/tr>\n
443<\/td>\nSECTION 6705 USE <\/td>\n<\/tr>\n
444<\/td>\nCHAPTERS 68 through 79 RESERVED <\/td>\n<\/tr>\n
446<\/td>\nPART VI\u2014REFERENCED STANDARDS
CHAPTER 80 REFERENCED STANDARDS
AASHTO
AFSI
API <\/td>\n<\/tr>\n
447<\/td>\nASME
ASTM <\/td>\n<\/tr>\n
448<\/td>\nBHMA
CA
CGA <\/td>\n<\/tr>\n
449<\/td>\nCGR
CPSC
DOC
DOL
DOTn <\/td>\n<\/tr>\n
450<\/td>\nDOTy
EN
EPA
FCC <\/td>\n<\/tr>\n
451<\/td>\nICC
ISO <\/td>\n<\/tr>\n
452<\/td>\nNEMA
NFPA <\/td>\n<\/tr>\n
454<\/td>\nUL <\/td>\n<\/tr>\n
455<\/td>\nUSC <\/td>\n<\/tr>\n
456<\/td>\nPART VII\u2014APPENDICES
APPENDIX B FIRE-FLOW REQUIREMENTS FOR BUILDINGS
SECTION B101 GENERAL
SECTION B102 DEFINITIONS
SECTION B103 MODIFICATIONS
SECTION B104 FIRE-FLOW CALCULATION AREA
SECTION B105 FIRE-FLOW REQUIREMENTS FOR BUILDINGS
SECTION B106 REFERENCED STANDARDS <\/td>\n<\/tr>\n
457<\/td>\nTABLE B105.1 MINIMUM REQUIRED FIRE-FLOW AND FLOW DURATION FOR BUILDINGS <\/td>\n<\/tr>\n
458<\/td>\nAPPENDIX C FIRE HYDRANT LOCATIONS AND DISTRIBUTION
SECTION C101 GENERAL
SECTION C102 LOCATION
SECTION C103 NUMBER OF FIRE HYDRANTS
SECTION C104 CONSIDERATION OF EXISTING FIRE HYDRANTS
SECTION C105 DISTRIBUTION OF FIRE HYDRANTS
TABLE C105.1 NUMBER AND DISTRIBUTION OF FIRE HYDRANTS <\/td>\n<\/tr>\n
460<\/td>\nAPPENDIX D FIRE APPARATUS ACCESS ROADS
SECTION D101 GENERAL
SECTION D102 REQUIRED ACCESS
SECTION D103 MINIMUM SPECIFICATIONS
TABLE D103.4 REQUIREMENTS FOR DEAD-END FIRE APPARATUS ACCESS ROADS
FIGURE D103.1 DEAD-END FIRE APPARATUS ACCESS ROAD TURNAROUND <\/td>\n<\/tr>\n
461<\/td>\nFIGURE D103.6 FIRE LANE SIGNS
SECTION D104 COMMERCIAL AND INDUSTRIAL DEVELOPMENTS
SECTION D105 AERIAL FIRE APPARATUS ACCESS ROADS <\/td>\n<\/tr>\n
462<\/td>\nSECTION D106 MULTIPLE-FAMILY RESIDENTIAL DEVELOPMENTS
SECTION D107 ONE- OR TWO-FAMILY RESIDENTIAL DEVELOPMENTS
D108 REFERENCED STANDARDS <\/td>\n<\/tr>\n
464<\/td>\nAPPENDIX E HAZARD CATEGORIES
SECTION E101 GENERAL
SECTION E102 HAZARD CATEGORIES <\/td>\n<\/tr>\n
468<\/td>\nSECTION E103 EVALUATION OF HAZARDS <\/td>\n<\/tr>\n
469<\/td>\nE104 REFERENCED STANDARDS <\/td>\n<\/tr>\n
470<\/td>\nAPPENDIX F HAZARD RANKING
SECTION F101 GENERAL
SECTION F102 REFERENCED STANDARDS <\/td>\n<\/tr>\n
471<\/td>\nTABLE F101.2 FIRE FIGHTER WARNING PLACARD DESIGNATIONS BASED ON HAZARD CLASSIFICATION CATEGORIES <\/td>\n<\/tr>\n
472<\/td>\nAPPENDIX G CRYOGENIC FLUIDS\u2014WEIGHT AND VOLUME EQUIVALENTS
SECTION G101 GENERAL <\/td>\n<\/tr>\n
473<\/td>\nTABLE G101.2 WEIGHT AND VOLUME EQUIVALENTS FOR COMMON CRYOGENIC FLUIDS <\/td>\n<\/tr>\n
474<\/td>\nAPPENDIX H HAZARDOUS MATERIALS MANAGEMENT PLAN (HMMP) AND HAZARDOUS MATERIALS INVENTORY STATEMENT (HMIS) INSTRUCTIONS
SECTION H101 HMMP
SECTION H102 HMIS <\/td>\n<\/tr>\n
475<\/td>\nSECTION H103 EMERGENCY PLAN
SECTION H104 REFERENCED STANDARDS <\/td>\n<\/tr>\n
476<\/td>\nFIGURE 1 HAZARDOUS MATERIALS MANAGEMENT PLAN SECTION I: FACILITY DESCRIPTION <\/td>\n<\/tr>\n
477<\/td>\nFIGURE 2 HAZARDOUS MATERIALS MANAGEMENT PLAN SECTION I: FACILITY DESCRIPTION <\/td>\n<\/tr>\n
478<\/td>\nFIGURE 3 HAZARDOUS MATERIALS MANAGEMENT PLAN SECTION I: FACILITY DESCRIPTION PART C\u2014FACILITY MAP <\/td>\n<\/tr>\n
479<\/td>\nFIGURE 4 SECTION II\u2014HAZARDOUS MATERIALS INVENTORY STATEMENT (HMIS) HMIS SUMMARY REPORTa (Storageb Conditions)c <\/td>\n<\/tr>\n
480<\/td>\nFIGURE 5 SECTION II \u2014 HAZARDOUS MATERIALS INVENTORY STATEMENT (HMIS) HMIS INVENTORY REPORT (Sort Products Alphabetically by Location of Product and then Alphabetically by Product Name) <\/td>\n<\/tr>\n
482<\/td>\nAPPENDIX I FIRE PROTECTION SYSTEMS\u2014NONCOMPLIANT CONDITIONS
SECTION I101 NONCOMPLIANT CONDITIONS <\/td>\n<\/tr>\n
483<\/td>\nSECTION I102 REFERENCED STANDARDS <\/td>\n<\/tr>\n
484<\/td>\nAPPENDIX J BUILDING INFORMATION SIGN
SECTION J101 GENERAL
FIGURE J101.1.3 EXAMPLE OF COMPLETED BUILDING INFORMATION SIGN <\/td>\n<\/tr>\n
486<\/td>\nSECTION J102 REFERENCED STANDARDS <\/td>\n<\/tr>\n
488<\/td>\nINDEX <\/td>\n<\/tr>\n
516<\/td>\nNEW TOOLS FOR YOUR FIRE CODE <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Virginia Statewide Fire Prevention Code, 2nd Edition<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
VA<\/b><\/a><\/td>\n2012<\/td>\n517<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":136097,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2718],"product_tag":[],"class_list":{"0":"post-136096","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-va","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/136096","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/136097"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=136096"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=136096"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=136096"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}