{"id":136376,"date":"2024-10-19T07:52:07","date_gmt":"2024-10-19T07:52:07","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-c37-013-1993\/"},"modified":"2024-10-25T00:02:04","modified_gmt":"2024-10-25T00:02:04","slug":"ieee-c37-013-1993","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-c37-013-1993\/","title":{"rendered":"IEEE C37.013 1993"},"content":{"rendered":"
Revision Standard – Inactive – Superseded. Ratings, performance requirements, and compliance test methods are provided for ac high-voltage generator circuit breakers rated on a symmetrical current basis that are installed between the generator and the transformer terminals. Guidance for applying the circuit breakers is given. Pumped storage installations are considered a special application, and their requirements are not completely covered by this standard.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
9<\/td>\n | Scope and references 1.1 scope 1.2 References <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | Definitions <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | Service conditions Usual service conditions <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | Unusual service conditions Impact on environment <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | Ratings and required capabilities Rated maximum voltage 4.2 Normal frequency <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | Rated continuous current <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 4.4 Rated dielectric strength <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | Rated short-circuit duty cycle 4.6 Rated interrupting time 4.7 Rated permissible tripping delay Y 4.8 Rated closing time Short-circuit current rating <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 4.10 Transient recovery voltage (TRV) rating <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 4.1 1 Rated load current switching capability <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 4.12 Capacitance current switching capability 4.13 Out-of-phase current switching capability <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | 4.14 Excitation current switching capability 4.15 Rated control voltage <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 4.16 Rated mechanism fluid operating pressure 4.17 Nameplate markings <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | Tests 5.2 Design tests <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | 5.4 Tests after delivery <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | Application guide 6.1 General General application conditions <\/td>\n<\/tr>\n | ||||||
57<\/td>\n | 6.3 Application considerations <\/td>\n<\/tr>\n | ||||||
80<\/td>\n | Guide to specification <\/td>\n<\/tr>\n | ||||||
81<\/td>\n | 7 Bibliography <\/td>\n<\/tr>\n | ||||||
83<\/td>\n | A.l System characteristics <\/td>\n<\/tr>\n | ||||||
84<\/td>\n | A.2 System source short-circuit current <\/td>\n<\/tr>\n | ||||||
87<\/td>\n | Generator source short-circuit current <\/td>\n<\/tr>\n | ||||||
90<\/td>\n | A.4 Transient recovery voltage Out-of-phase conditions <\/td>\n<\/tr>\n | ||||||
92<\/td>\n | A.6 Continous current application <\/td>\n<\/tr>\n | ||||||
93<\/td>\n | Generator circuit breaker electrical characteristics <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" IEEE Standard for AC High Voltage Generator Circuit Breakers Rated on a Symmetrical Current Basis<\/b><\/p>\n |