{"id":136473,"date":"2024-10-19T07:52:28","date_gmt":"2024-10-19T07:52:28","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-1566-2015\/"},"modified":"2024-10-25T00:02:26","modified_gmt":"2024-10-25T00:02:26","slug":"ieee-1566-2015","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-1566-2015\/","title":{"rendered":"IEEE 1566 2015"},"content":{"rendered":"
Revision Standard – Active. AC adjustable speed drive (ASD) systems rated above 375 kW and above 750 V output voltage as used in petrochemical and similar applications are applicable to this standard. Performance requirements for an ASD system including, but not limited to, input transformer or reactor as required, power electronics, control interfaces, cooling system, switchgear, and motor are covered. Requirements for power quality, engineering analysis, start-up assistance, training, and spare parts are also included. Certain items such as the motor, switchgear, or transformer may be excluded from the scope of vendor supply if specified in the data sheets; any special requirements for the excluded equipment shall be given by the system vendor.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | IEEE Std 1566\u2122-2015 Front Cover <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | Title page <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | Important Notices and Disclaimers Concerning IEEE Standards Documents <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | Participants <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | Contents <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | Important Notice 1. Overview 1.1 Scope 1.2 Purpose <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 1.3 Application <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 2. Normative references <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 3. Definitions, acronyms and abbreviations 3.1 Definitions 3.2 Acronyms and abbreviations <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 4. Safety 4.1 General 4.2 ASD construction requirements <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 5. Unit construction 5.1 ASD structure 5.2 Insulation 5.3 Nameplate <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 5.4 Rectifier 5.5 DC link 5.6 Inverter <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 5.7 Modular system 6. Adjustable speed operation 6.1 Power supply 6.2 Harmonics 6.3 Capacity <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 6.4 Performance 6.5 Grounding <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 6.6 Rating of supply 6.7 Transient over-voltages 6.8 Voltage sags <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 6.9 ASD supply voltage ride through 6.10 Loss of voltage <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | 6.11 Three-phase voltage swells 6.12 Voltage distortion 6.13 Voltage unbalance <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 6.14 Common-mode voltage 6.15 Power-factor correction capacitors\u2014switching transients 6.16 Harmonic distortion <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 6.17 Electromagnetic interference and radio-frequency interference 6.18 Acoustic noise level 7. Control 7.1 General <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | 7.2 Local control 7.3 Remote control (general) <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | 7.4 Bypass operation <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | 8. Input transformer or reactor 8.1 Transformer <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | 8.2 Reactor 9. Motor 9.1 Specification <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | 9.2 Temperatures 9.3 Synchronous motor 9.4 Retrofit <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | 10. Switchgear and starters 10.1 Requirements 10.2 Switchgear supply 11. Cooling system 11.1 Cooling system equipment 11.2 Air cooling <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | 11.3 Liquid cooling <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | 12. System coordination 12.1 Responsibility 12.2 Compatibility 13. Engineering studies 13.1 General 13.2 Studies to determine process or driven equipment requirements 13.3 Power-system analysis to determine system response to ASD 13.4 Studies to determine system mechanical constraints 13.5 Studies to determine heating or cooling constraints 13.6 Reliability analysis <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | 14. Inspection and factory tests 14.1 Records 14.2 Test plan <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | 14.3 Motor tests 14.4 System test <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | 14.5 Testing of synchronous motor applications 15. Shipping, Handling and Storage Requirements <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | 16. Commissioning and startup assistance 16.1 Commissioning plan 16.2 Field service <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | 16.3 Results 16.4 Training 17. Spare parts 18. Data interchange <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | Annex A (normative) MV adjustable-speed drives electrical data sheets for purchasers <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | Annex B (normative) MV adjustable-speed drives electrical data sheets for manufacturers <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | Annex C (informative) Technical data sheet guide C.1 General C.2 Project reference, date C.3 Reference single-line diagram (SLD) <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | C.4 System of units C.5 Supply system voltage C.6 Short-circuit level C.7 Line frequency C.8 ASD auxiliary three-phase power C.9 Control power C.10 ASD continuous rating <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | C.11 Load\/application requirements C.12 Harmonics C.13 System grounding C.14 Ground fault detection provided in upstream switchgear <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | C.15 Design standards C.16 Site environment C.17 ASD to be mounted in a pre-fabricated building C.18 Enclosure C.19 Incoming and load cable details <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | C.20 Finish C.21 Redundancy C.22 Voltage sag ride-through C.23 Flying restart C.24 Noise level C.25 Local control <\/td>\n<\/tr>\n | ||||||
57<\/td>\n | C.26 Motor\/transformer protection relays to be mounted in an ASD enclosure C.27 Discrete I\/O C.28 4-ma to 20-mA isolated analog outputs C.29 Communication options C.30 Remote C.31 Bypass operation <\/td>\n<\/tr>\n | ||||||
58<\/td>\n | C.32 Input transformer\/reactor C.33 Motor C.34 Breakaway torque <\/td>\n<\/tr>\n | ||||||
59<\/td>\n | C.35 Speed regulation C.36 Torque mode C.37 ASD cooling methods C.38 Testing C.39 Shipping, storage, and handling <\/td>\n<\/tr>\n | ||||||
60<\/td>\n | C.40 Services C.41 Nameplate data C.42 Special Applications C.43 Classified locations C.44 Long cable applications C.45 Marine and offshore facilities <\/td>\n<\/tr>\n | ||||||
61<\/td>\n | C.46 Local generation\/limited supply <\/td>\n<\/tr>\n | ||||||
62<\/td>\n | Annex D (informative) Engineering studies: typical requirements (tutorial only) D.1 Process or driven equipment requirements D.2 System response to ASD D.3 Rotational dynamics <\/td>\n<\/tr>\n | ||||||
63<\/td>\n | D.4 Torsional analysis D.5 Information required for a torsional analysis <\/td>\n<\/tr>\n | ||||||
64<\/td>\n | D.6 Studies to determine the heating or cooling requirements <\/td>\n<\/tr>\n | ||||||
65<\/td>\n | Annex E (informative) Specialized applications E.1 Background E.2 Classified locations <\/td>\n<\/tr>\n | ||||||
66<\/td>\n | E.3 Long cable applications <\/td>\n<\/tr>\n | ||||||
67<\/td>\n | E.4 Marine and offshore facilities <\/td>\n<\/tr>\n | ||||||
69<\/td>\n | E.5 Local generation\/limited supply <\/td>\n<\/tr>\n | ||||||
71<\/td>\n | Annex F (informative) Bibliography <\/td>\n<\/tr>\n | ||||||
74<\/td>\n | Back Cover <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" IEEE Standard for Performance of Adjustable-Speed AC Drives Rated 375 kW and Larger<\/b><\/p>\n |