{"id":137674,"date":"2024-10-19T07:57:26","date_gmt":"2024-10-19T07:57:26","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/asme-a17-5-2014\/"},"modified":"2024-10-25T00:08:35","modified_gmt":"2024-10-25T00:08:35","slug":"asme-a17-5-2014","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/asme\/asme-a17-5-2014\/","title":{"rendered":"ASME A17.5 2014"},"content":{"rendered":"

ASME A17.5 applies to the electrical equipment for elevators, escalators, moving walks, dumbwaiters, material lifts, and elevating devices for persons with physical disabilities (platform lifts and stairway chairlifts): \u2022 motor controllers; \u2022 motion controllers; \u2022 operation controllers; \u2022 operating devices; and \u2022 all other electrical equipment not listed\/certified and labeled\/marked according to another product safety standard or code. The equipment specified in this Safety Standard is intended for installation in accordance with the Canadian Electrical Code, Part 1 (CSA C22.1) and the National Electrical Code (NFPA 70), whichever is applicable. Note: Controllers, i.e. motion, motor and operation controllers, are defined in CSA B44 and ASME A17.1. ASME has been defining safety in elevators, escalators and related equipment since 1921. ASME A17.5 is harmonized with CSA B44.1 to provide one comprehensive solution for jurisdictions throughout North America. This Safety Standard is to be used in conjunction with other volumes of ASME\u2019s A17 series of safety standards. Careful application of these A17 safety standards will help users to comply with applicable regulations within their jurisdictions, while achieving the operational and safety benefits to be gained from the many industry best-practices detailed within these volumes. Intended for anyone involved with the safety of elevators, escalators and related conveyances.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
3<\/td>\nERRATA <\/td>\n<\/tr>\n
5<\/td>\nStandards Update Service <\/td>\n<\/tr>\n
9<\/td>\nContents <\/td>\n<\/tr>\n
12<\/td>\nCSA Technical Committee on the Elevator Safety Code <\/td>\n<\/tr>\n
15<\/td>\nASME A17 Elevator and Escalator Standards Committee <\/td>\n<\/tr>\n
17<\/td>\nCSA B44.1\/ASME A17.5 Joint Committee on Elevator and Escalator Electrical Equipment <\/td>\n<\/tr>\n
19<\/td>\nPreface <\/td>\n<\/tr>\n
21<\/td>\n1 Scope <\/td>\n<\/tr>\n
22<\/td>\n2 Reference publications, abbreviations, and definitions
2.1 Reference publications <\/td>\n<\/tr>\n
24<\/td>\n2.2 Abbreviations
2.3 Definitions <\/td>\n<\/tr>\n
27<\/td>\n3 Construction
4 Enclosure construction
4.1 General
4.2 Thickness of cast-metal enclosures for live parts <\/td>\n<\/tr>\n
28<\/td>\n4.3 Thickness of sheet-metal enclosures for live parts
5 Doors and covers <\/td>\n<\/tr>\n
29<\/td>\n6 Polymeric enclosures <\/td>\n<\/tr>\n
31<\/td>\n7 Openings in enclosures
7.1 Requirements for all enclosures <\/td>\n<\/tr>\n
32<\/td>\n7.2 Requirements for equipment enclosures marked in accordance with Clause 20.22
8 Wire-bending space <\/td>\n<\/tr>\n
33<\/td>\n9 Enclosures with environmental ratings
10 Protection against corrosion
11 Insulating material
12 Protective devices
12.1 Overcurrent protection
12.2 Number, arrangement, and ratings or settings of protective devices <\/td>\n<\/tr>\n
34<\/td>\n12.3 Supplementary overcurrent protection
12.4 Disconnecting means <\/td>\n<\/tr>\n
36<\/td>\n12.5 Power from more than one source
13 Protection of control circuits
13.1 Control circuit conductor protection
13.2 Control circuit transformer protection <\/td>\n<\/tr>\n
37<\/td>\n13.3 Use of supplementary protectors in control circuits <\/td>\n<\/tr>\n
38<\/td>\n14 Internal wiring
15 Wiring terminals and leads <\/td>\n<\/tr>\n
40<\/td>\n16 Electrical spacings <\/td>\n<\/tr>\n
44<\/td>\n17 Grounding <\/td>\n<\/tr>\n
45<\/td>\n18 Printed circuit boards
19 Tests
19.1 General <\/td>\n<\/tr>\n
46<\/td>\n19.2 Endurance
19.3 Solid-state ac motor controller tests <\/td>\n<\/tr>\n
48<\/td>\n19.4 Power-conversion equipment <\/td>\n<\/tr>\n
51<\/td>\n19.5 Impact test
19.6 Printed circuit board coatings <\/td>\n<\/tr>\n
52<\/td>\n19.7 Transient-voltage-surge suppression
19.8 Compression
19.9 Deflection <\/td>\n<\/tr>\n
53<\/td>\n19.10 Cord pullout
19.11 Crushing resistance test
20 Marking <\/td>\n<\/tr>\n
59<\/td>\nTables
\n
Table 1 Thickness of sheet metal for enclosures \u2014 Carbon steel or stainless steel <\/td>\n<\/tr>\n
60<\/td>\nTable 2 Thickness of sheet metal for enclosures \u2014 Aluminum, copper, or brass <\/td>\n<\/tr>\n
61<\/td>\nTable 3 Size of bonding conductor
Table 4 Minimum acceptable distance from an opening to a part that can involve a risk of electric shock or injury to persons <\/td>\n<\/tr>\n
62<\/td>\nTable 5 Minimum spacings for live parts <\/td>\n<\/tr>\n
63<\/td>\nTable 6 Wire-bending space at the terminal of enclosed motor controllers
Table 7 Maximum acceptable rating of overcurrent device <\/td>\n<\/tr>\n
64<\/td>\nTable 8 Allowable ampacities of insulated copper conductors inside elevator electrical equipment enclosures (based on a maximum room ambient temperature of 40 \u00b0C)
Table 9 Ampacity correction factors for multiple conductor groupings <\/td>\n<\/tr>\n
65<\/td>\nTable 10 Full-load motor-running currents in amperescorresponding to various ac horsepower ratings <\/td>\n<\/tr>\n
67<\/td>\nTable 11 Full-load motor-running currents in amperes correspondingto various dc horsepower ratings <\/td>\n<\/tr>\n
68<\/td>\nTable 12 Minimum conductor spacings for printed circuit boards* <\/td>\n<\/tr>\n
69<\/td>\nTable 13 Minimum acceptable spacings for equipment for which transient voltages are known and controlled <\/td>\n<\/tr>\n
70<\/td>\nTable 14 Dimensions of bushings
Table 15 Size and number of conductors per grounding termination <\/td>\n<\/tr>\n
71<\/td>\nTable 16 Size of grounding conductors <\/td>\n<\/tr>\n
72<\/td>\nTable 17 Sequence of tests for solid-state ac motor controllers <\/td>\n<\/tr>\n
73<\/td>\nTable 18 Maximum permissible temperature rises <\/td>\n<\/tr>\n
75<\/td>\nTable 19 Sequence of tests for power-conversion equipment <\/td>\n<\/tr>\n
76<\/td>\nTable 20 Rating codes for ac control circuit contacts at 50 and 60 Hz <\/td>\n<\/tr>\n
77<\/td>\nTable 21 Rating codes for dc control circuit contacts <\/td>\n<\/tr>\n
78<\/td>\nFigures
Figure 1 Articulated probe <\/td>\n<\/tr>\n
79<\/td>\nFigure 2 Location of applicators for crushing resistance test <\/td>\n<\/tr>\n
80<\/td>\nAnnex A (informative) <\/td>\n<\/tr>\n
86<\/td>\nAnnex B (informative) <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

ASME A17.5 Elevator and Escalator Electrical Equipment<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ASME<\/b><\/a><\/td>\n2014<\/td>\n89<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":137679,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2643],"product_tag":[],"class_list":{"0":"post-137674","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-asme","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/137674","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/137679"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=137674"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=137674"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=137674"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}