{"id":137853,"date":"2024-10-19T07:58:10","date_gmt":"2024-10-19T07:58:10","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/pa-philadelphiafirecode-2013\/"},"modified":"2024-10-25T00:09:21","modified_gmt":"2024-10-25T00:09:21","slug":"pa-philadelphiafirecode-2013","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/pa\/pa-philadelphiafirecode-2013\/","title":{"rendered":"PA PhiladelphiaFireCode 2013"},"content":{"rendered":"
None<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | THE CITY OF PHILADELPHIA FIRE CODE 2013 <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | THE CITY OF PHILADELPHIA FIRE CODE 2013 TITLE PAGE <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | COPYRIGHT <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | HISTORY OF THE PHILADELPHIA CODE <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | NOTE TO USERS OF THE PHILADELPHIA FIRE CODE <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | TABLE OF CONTENTS <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | CHAPTER 1 ADMINISTRATION SECTION F-101 GENERAL SECTION F-102 APPLICABILITY <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | SECTION F-103 UNSAFE CONDITIONS SECTION F-104 GENERAL AUTHORITY AND RESPONSIBILITIES SECTION F-105 PERMITS <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | TABLE F-105.6.3 PERMIT AMOUNTS FOR COMPRESSED GASES TABLE F-105.6.4 PERMIT AMOUNTS FOR CRYOGENIC FLUIDS <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | TABLE F-105.6.9 PERMIT AMOUNTS FOR HAZARDOUS MATERIALS <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | SECTION F-106 MAINTENANCE SECTION 107 APPEALS OF VIOLATIONS <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | SECTION 108 BOARD OF SAFETY AND FIRE PREVENTION <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | CHAPTER 2 DEFINITIONS SECTION 201 GENERAL SECTION 202 GENERAL DEFINITIONS <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | CHAPTER 3 GENERAL REQUIREMENTS SECTION 301 GENERAL SECTION 302 DEFINITIONS SECTION 303 ASPHALT KETTLES <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | SECTION 304 COMBUSTIBLE WASTE MATERIAL <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | SECTION 305 IGNITION SOURCES SECTION 306 MOTION PICTURE PROJECTION ROOMS AND FILM SECTION 307 OPEN BURNING, RECREATIONAL FIRES AND PORTABLE OUTDOOR FIREPLACES <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | SECTION 308 OPEN FLAMES <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | SECTION 309 POWERED INDUSTRIAL TRUCKS AND EQUIPMENT <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | SECTION 310 SMOKING SECTION 311 VACANT PREMISES <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | SECTION 312 VEHICLE IMPACT PROTECTION <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | SECTION 313 FUELED EQUIPMENT SECTION 314 INDOOR DISPLAYS SECTION 315 MISCELLANEOUS COMBUSTIBLE MATERIALS STORAGE <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | SECTION 316 HAZARDS TO FIGHTERS <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | SECTION 317 LAUNDRY CARTS <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | CHAPTER 4 EMERGENCY PLANNING AND PREPAREDNESS SECTION 401 GENERAL SECTION 402 DEFINITIONS SECTION 403 PUBLIC ASSEMBLAGES AND EVENTS <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | SECTION 404 FIRE SAFETY AND EVACUATION PLANS <\/td>\n<\/tr>\n | ||||||
57<\/td>\n | SECTION 405 EMERGENCY EVACUATION DRILLS TABLE 405.2 FIRE AND EVACUATION DRILL FREQUENCY AND PARTICIPATION <\/td>\n<\/tr>\n | ||||||
58<\/td>\n | SECTION 406 EMPLOYEE TRAINING AND RESPONSE PROCEDURES SECTION 407 HAZARD COMMUNICATION SECTION 408 USE AND OCCUPANCY-RELATED REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
62<\/td>\n | SECTION F-409 HOME CHILD DAY CARE FACILITIES <\/td>\n<\/tr>\n | ||||||
64<\/td>\n | CHAPTER 5 FIRE SERVICE FEATURES SECTION 501 GENERAL SECTION 502 DEFINITIONS SECTION 503 FIRE APPARATUS ACCESS ROADS <\/td>\n<\/tr>\n | ||||||
66<\/td>\n | SECTION 504 ACCESS TO BUILDING OPENINGS AND ROOFS SECTION 505 PREMISES IDENTIFICATION SECTION 506 KEY BOXES SECTION 507 FIRE PROTECTION WATER SUPPLIES <\/td>\n<\/tr>\n | ||||||
68<\/td>\n | SECTION 508 FIRE COMMAND CENTER <\/td>\n<\/tr>\n | ||||||
69<\/td>\n | SECTION 509 FIRE PROTECTION EQUIPMENT IDENTIFICATION AND ACCESS SECTION 510 EMERGENCY RESPONDER RADIO COVERAGE <\/td>\n<\/tr>\n | ||||||
74<\/td>\n | CHAPTER 6 BUILDING SERVICES AND SYSTEMS SECTION 601 GENERAL SECTION 602 DEFINITIONS <\/td>\n<\/tr>\n | ||||||
75<\/td>\n | SECTION 603 FUEL-FIRED APPLIANCES <\/td>\n<\/tr>\n | ||||||
78<\/td>\n | SECTION 604 EMERGENCY AND STANDBY POWER SYSTEMS <\/td>\n<\/tr>\n | ||||||
81<\/td>\n | SECTION 605 ELECTRICAL EQUIPMENT, WIRING AND HAZARDS <\/td>\n<\/tr>\n | ||||||
83<\/td>\n | SECTION 606 MECHANICAL REFRIGERATION <\/td>\n<\/tr>\n | ||||||
85<\/td>\n | SECTION 607 ELEVATORS SECTION 608 STATIONARY STORAGE BATTERY SYSTEMS <\/td>\n<\/tr>\n | ||||||
86<\/td>\n | TABLE 608.1 BATTERY REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
87<\/td>\n | SECTION 609 COMMERCIAL KITCHEN HOODS <\/td>\n<\/tr>\n | ||||||
88<\/td>\n | TABLE 609.3.3.1 COMMERCIAL COOKING SYSTEM INSPECTION FREQUENCY <\/td>\n<\/tr>\n | ||||||
90<\/td>\n | CHAPTER 7 FIRE-RESISTANCE-RATED CONSTRUCTION SECTION 701 GENERAL SECTION 702 DEFINITIONS SECTION 703 FIRE-RESISTANCE-RATED CONSTRUCTION <\/td>\n<\/tr>\n | ||||||
91<\/td>\n | SECTION 704 FLOOR OPENINGS AND SHAFTS <\/td>\n<\/tr>\n | ||||||
94<\/td>\n | CHAPTER 8 INTERIOR FINISH, DECORATIVE MATERIALS AND FURNISHINGS SECTION 801 GENERAL SECTION 802 DEFINITIONS SECTION 803 INTERIOR WALL AND CEILING FINISH AND TRIM IN EXISTING BUILDINGS <\/td>\n<\/tr>\n | ||||||
95<\/td>\n | TABLE 803.3 INTERIOR WALL AND CEILING REQUIREMENTS BY OCCUPANCYk <\/td>\n<\/tr>\n | ||||||
97<\/td>\n | SECTION 804 INTERIOR WALL AND CEILING TRIM IN NEW AND EXISTING BUILDINGS SECTION 805 UPHOLSTERED FURNITURE AND MATTRESSES IN NEW AND EXISTING BUILDINGS <\/td>\n<\/tr>\n | ||||||
100<\/td>\n | SECTION 806 DECORATIVE VEGETATION IN NEW AND EXISTING BUILDINGS <\/td>\n<\/tr>\n | ||||||
101<\/td>\n | SECTION 807 DECORATIVE MATERIALS OTHER THAN DECORATIVE VEGETATION IN NEW AND EXISTING BUILDINGS <\/td>\n<\/tr>\n | ||||||
102<\/td>\n | SECTION 808 FURNISHINGS OTHER THAN UPHOLSTERED FURNITURE AND MATTRESSES OR DECORATIVE MATERIALS IN NEW AND EXISTING BUILDINGS <\/td>\n<\/tr>\n | ||||||
104<\/td>\n | CHAPTER 9 FlRE PROTECTION SYSTEMS SECTION 901 GENERAL <\/td>\n<\/tr>\n | ||||||
105<\/td>\n | TABLE 901.6.1 FlRE PROTECTION SYSTEM MAINTENANCE STANDARDS <\/td>\n<\/tr>\n | ||||||
107<\/td>\n | SECTION 902 DEFINITIONS <\/td>\n<\/tr>\n | ||||||
110<\/td>\n | SECTION 903 AUTOMATIC SPRINKLER SYSTEMS <\/td>\n<\/tr>\n | ||||||
111<\/td>\n | SECTION 904 ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS <\/td>\n<\/tr>\n | ||||||
114<\/td>\n | SECTION 905 STANDPIPE SYSTEMS <\/td>\n<\/tr>\n | ||||||
115<\/td>\n | SECTION 906 PORTABLE FIRE EXTINGUISHERS TABLE 906.1 ADDITIONAL REQUIRED PORTABLE FIRE EXTINGUISHERS <\/td>\n<\/tr>\n | ||||||
116<\/td>\n | TABLE 906.3(1) FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS TABLE 906.3(2) FLAMMABLE OR COMBUSTIBLE LIQUIDS WITH DEPTHS OF LESS THAN OR EQUAL TO 0.25-INCH <\/td>\n<\/tr>\n | ||||||
117<\/td>\n | SECTION 907 FIRE ALARM AND DETECTION SYSTEMS <\/td>\n<\/tr>\n | ||||||
122<\/td>\n | SECTION 908 EMERGENCY ALARM SYSTEMS <\/td>\n<\/tr>\n | ||||||
123<\/td>\n | SECTION 909 SMOKE CONTROL SYSTEMS <\/td>\n<\/tr>\n | ||||||
124<\/td>\n | SECTION 910 SMOKE AND HEAT VENTS SECTION 911 EXPLOSION CONTROL <\/td>\n<\/tr>\n | ||||||
125<\/td>\n | TABLE 911.1 EXPLOSION CONTROL REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
126<\/td>\n | SECTION 912 FIRE DEPARTMENT CONNECTIONS <\/td>\n<\/tr>\n | ||||||
127<\/td>\n | SECTION 913 FlRE PUMPS SECTION 914 FIRE PROTECTION BASED ON SPECIAL DETAILED REQUIREMENTS OF USE AND OCCUPANCY <\/td>\n<\/tr>\n | ||||||
128<\/td>\n | SECTION 915 PERIODIC TESTING OF FIRE PROTECTION SYSTEMS <\/td>\n<\/tr>\n | ||||||
130<\/td>\n | CHAPTER 10 MEANS OF EGRESS SECTION 1001 GENERAL SECTION 1002 DEFINITIONS <\/td>\n<\/tr>\n | ||||||
132<\/td>\n | SECTION 1003 GENERAL MEANS OF EGRESS TABLE 1003.2 EGRESS WIDTH PER OCCUPANT SERVED SECTION 1004 OCCUPANT LOAD <\/td>\n<\/tr>\n | ||||||
133<\/td>\n | SECTION 1005 CORRIDORS AND AISLES <\/td>\n<\/tr>\n | ||||||
134<\/td>\n | TABLE 1005.1.4 COMMON PATH, DEAD-END AND TRAVEL DISTANCE LIMITS (by occupancy) SECTION 1006 MEANS OF EGRESS ILLUMINATION <\/td>\n<\/tr>\n | ||||||
135<\/td>\n | SECTION 1007 EXIT SIGNS <\/td>\n<\/tr>\n | ||||||
136<\/td>\n | SECTION 1008 DOORS, GATES AND TURNSTILES <\/td>\n<\/tr>\n | ||||||
140<\/td>\n | TABLE 1008.3 REVOLVING DOOR SPEEDS SECTION 1009 STAIRWAYS <\/td>\n<\/tr>\n | ||||||
141<\/td>\n | SECTION 1010 RAMPS SECTION 1011 FIRE ESCAPES SECTION 1012 VERTICAL OPENINGS <\/td>\n<\/tr>\n | ||||||
142<\/td>\n | SECTION 1013 GUARDS <\/td>\n<\/tr>\n | ||||||
143<\/td>\n | SECTION 1014 EXITS AND EXIT ENCLOSURES <\/td>\n<\/tr>\n | ||||||
144<\/td>\n | SECTION 1015 AREAS OF REFUGE SECTION 1016 MAINTENANCE OF MEANS OF EGRESS <\/td>\n<\/tr>\n | ||||||
146<\/td>\n | CHAPTER 11 AVIATION FACILITIES SECTION 1101 GENERAL SECTION 1102 DEFINITIONS SECTION 1103 GENERAL PRECAUTIONS SECTION 1104 AIRCRAFT MAINTENANCE <\/td>\n<\/tr>\n | ||||||
147<\/td>\n | SECTION 1105 PORTABLE FIRE EXTINGUISHERS <\/td>\n<\/tr>\n | ||||||
148<\/td>\n | SECTION 1106 AIRCRAFT FUELING <\/td>\n<\/tr>\n | ||||||
153<\/td>\n | SECTION 1107 HELISTOPS AND HELIPORTS <\/td>\n<\/tr>\n | ||||||
156<\/td>\n | CHAPTER 12 DRY CLEANING SECTION 1201 GENERAL SECTION 1202 DEFINITIONS SECTION 1203 CLASSIFICATIONS <\/td>\n<\/tr>\n | ||||||
157<\/td>\n | SECTION 1204 GENERAL REQUIREMENTS SECTION 1205 OPERATING REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
158<\/td>\n | SECTION 1206 SPOTTING AND PRETREATING SECTION 1207 DRY CLEANING SYSTEMS <\/td>\n<\/tr>\n | ||||||
159<\/td>\n | SECTION 1208 FIRE PROTECTION <\/td>\n<\/tr>\n | ||||||
160<\/td>\n | CHAPTER 13 COMBUSTIBLE DUST-PRODUCING OPERATIONS SECTION 1301 GENERAL SECTION 1302 DEFINITIONS SECTION 1303 PRECAUTIONS SECTION 1304 EXPLOSION PROTECTION TABLE 1304.1 EXPLOSION PROTECTION STANDARDS <\/td>\n<\/tr>\n | ||||||
162<\/td>\n | CHAPTER 14 FIRE SAFETY DURING CONSTRUCTION AND DEMOLITION SECTION 1401 GENERAL SECTION 1402 DEFINITIONS SECTION 1403 TEMPORARY HEATING EQUIPMENT SECTION 1404 PRECAUTIONS AGAINST FIRE SECTION 1405 FLAMMABLE AND COMBUSTIBLE LIQUIDS <\/td>\n<\/tr>\n | ||||||
163<\/td>\n | SECTION 1406 FLAMMABLE GASES SECTION 1407 EXPLOSIVE MATERIALS SECTION 1408 OWNER’S RESPONSIBILITY FOR FIRE PROTECTION SECTION 1409 FIRE REPORTING SECTION 1410 ACCESS FOR FIRE FIGHTING <\/td>\n<\/tr>\n | ||||||
164<\/td>\n | SECTION 1411 MEANS OF EGRESS SECTION 1412 WATER SUPPLY FOR FIRE PROTECTION SECTION 1413 STANDPIPES SECTION 1414 AUTOMATIC SPRINKLER SYSTEM SECTION 1415 PORTABLE FIRE EXTINGUISHERS SECTION 1416 MOTORIZED EQUIPMENT <\/td>\n<\/tr>\n | ||||||
165<\/td>\n | SECTION 1417 SAFEGUARDING ROOFING OPERATIONS SECTION 1418 ASBESTOS ABATEMENT <\/td>\n<\/tr>\n | ||||||
166<\/td>\n | CHAPTER 15 FLAMMABLE FINISHES SECTION 1501 GENERAL SECTION 1502 DEFINITIONS <\/td>\n<\/tr>\n | ||||||
167<\/td>\n | SECTION 1503 PROTECTION OF OPERATIONS <\/td>\n<\/tr>\n | ||||||
169<\/td>\n | SECTION 1504 SPRAY FINISHING <\/td>\n<\/tr>\n | ||||||
173<\/td>\n | SECTION 1505 DIPPING OPERATIONS <\/td>\n<\/tr>\n | ||||||
175<\/td>\n | SECTION 1506 POWDER COATING <\/td>\n<\/tr>\n | ||||||
176<\/td>\n | SECTION 1507 ELECTROSTATIC APPARATUS <\/td>\n<\/tr>\n | ||||||
177<\/td>\n | SECTION 1508 ORGANIC PEROXIDES AND DUAL-COMPONENT COATINGS SECTION 1509 INDOOR MANUFACTURING OF REINFORCED PLASTICS <\/td>\n<\/tr>\n | ||||||
178<\/td>\n | SECTION 1510 FLOOR SURFACING AND FINISHING OPERATIONS <\/td>\n<\/tr>\n | ||||||
180<\/td>\n | CHAPTER 16 FRUIT AND CROP RIPENING SECTION 1601 GENERAL SECTION 1602 DEFINITIONS SECTION 1603 ETHYLENE GAS SECTION 1604 SOURCES OF IGNITION SECTION 1605 COMBUSTIBLE WASTE SECTION 1606 ETHYLENE GENERATORS SECTION 1607 WARNING SIGNS <\/td>\n<\/tr>\n | ||||||
182<\/td>\n | CHAPTER 17 FUMIGATION AND THERMAL INSECTICIDAL FOGGING SECTION 1701 GENERAL SECTION 1702 DEFINITIONS SECTION 1703 FIRE SAFETY REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
184<\/td>\n | CHAPTER 18 SEMICONDUCTOR FABRICATION FACILITIES SECTION 1801 GENERAL SECTION 1802 DEFINITIONS <\/td>\n<\/tr>\n | ||||||
185<\/td>\n | SECTION 1803 GENERAL SAFETY PROVISIONS <\/td>\n<\/tr>\n | ||||||
190<\/td>\n | SECTION 1804 STORAGE SECTION 1805 USE AND HANDLING <\/td>\n<\/tr>\n | ||||||
191<\/td>\n | TABLE 1804.2.2.1 QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5a <\/td>\n<\/tr>\n | ||||||
192<\/td>\n | TABLE 1805.2.2 MAXIMUM QUANTITIES OF HPM AT A WORKSTATIONd <\/td>\n<\/tr>\n | ||||||
194<\/td>\n | CHAPTER 19 LUMBER YARDS AND WOODWORKING FACILITIES SECTION 1901 GENERAL SECTION 1902 DEFINITIONS SECTION 1903 GENERAL REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
195<\/td>\n | SECTION 1904 FIRE PROTECTION SECTION 1905 PLYWOOD, VENEER AND COMPOSITE BOARD MILLS SECTION 1906 LOG STORAGE AREAS SECTION 1907 STORAGE OF WOOD CHIPS AND HOGGED MATERIAL ASSOCIATED WITH TIMBER AND LUMBER PRODUCTION FACILITIES <\/td>\n<\/tr>\n | ||||||
196<\/td>\n | SECTION 1908 STORAGE AND PROCESSING OF WOOD CHIPS, HOGGED MATERIAL, FINES, COMPOST AND RAW PRODUCT ASSOCIATED WITH YARD WASTE AND RECYCLING FACILITIES SECTION 1909 EXTERIOR STORAGE OF FINISHED LUMBER PRODUCTS <\/td>\n<\/tr>\n | ||||||
198<\/td>\n | CHAPTER 20 MANUFACTURE OF ORGANIC COATINGS SECTION 2001 GENERAL SECTION 2002 DEFINITIONS SECTION 2003 GENERAL PRECAUTIONS SECTION 2004 ELECTRICAL EQUIPMENT AND PROTECTION <\/td>\n<\/tr>\n | ||||||
199<\/td>\n | SECTION 2005 PROCESS STRUCTURES SECTION 2006 PROCESS MILLS AND KETTLES <\/td>\n<\/tr>\n | ||||||
200<\/td>\n | SECTION 2007 PROCESS PIPING SECTION 2008 RAW MATERIALS IN PROCESS AREAS SECTION 2009 RAW MATERIALS AND FINISHED PRODUCTS <\/td>\n<\/tr>\n | ||||||
202<\/td>\n | CHAPTER 21 INDUSTRIAL OVENS SECTION 2101 GENERAL SECTION 2102 DEFINITIONS SECTION 2103 LOCATION SECTION 2104 FUEL PIPING <\/td>\n<\/tr>\n | ||||||
203<\/td>\n | SECTION 2105 INTERLOCKS SECTION 2106 FIRE PROTECTION SECTION 2107 OPERATION AND MAINTENANCE <\/td>\n<\/tr>\n | ||||||
204<\/td>\n | CHAPTER 22 MOTOR FUEL-DISPENSING FACILITIES AND REPAIR GARAGES SECTION 2201 GENERAL SECTION 2202 DEFINITIONS <\/td>\n<\/tr>\n | ||||||
205<\/td>\n | SECTION 2203 LOCATION OF DISPENSING DEVICES SECTION 2204 DISPENSING OPERATIONS <\/td>\n<\/tr>\n | ||||||
206<\/td>\n | SECTION 2205 OPERATIONAL REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
207<\/td>\n | SECTION 2206 FLAMMABLE AND COMBUSTIBLE LIQUID MOTOR FUEL-DISPENSING FACILITIES <\/td>\n<\/tr>\n | ||||||
208<\/td>\n | TABLE 2206.2.3 MINIMUM SEPARATION REQUIREMENTS FOR ABOVE-GROUND TANKS <\/td>\n<\/tr>\n | ||||||
212<\/td>\n | SECTION 2207 LIQUEFIED PETROLEUM GAS MOTOR FUEL-DISPENSING FACILITIES <\/td>\n<\/tr>\n | ||||||
213<\/td>\n | SECTION 2208 COMPRESSED NATURAL GAS MOTOR FUEL-DISPENSING FACILITIES <\/td>\n<\/tr>\n | ||||||
215<\/td>\n | TABLE 2208.8.1.2.3 SEPARATION DISTANCE FOR ATMOSPHERIC VENTING OF CNG SECTION 2209 HYDROGEN MOTOR FUEL-DISPENSING AND GENERATION FACILITIES <\/td>\n<\/tr>\n | ||||||
216<\/td>\n | TABLE 2209.3.1 MINIMUM SEPARATION FOR GASEOUS HYDROGEN DISPENSERS, COMPRESSORS ,GENERATORS AND STORAGE VESSELS <\/td>\n<\/tr>\n | ||||||
219<\/td>\n | TABLE 2209.5.4.3.4 VENT PIPE HEIGHT AND SEPARATION DISTANCE VERSUS HYDROGEN FLOW RATE AND VENT PIPE DIAMETER a,b,c,d,e,f FIGURE 2209.5.4.3.4 HYDROGEN VENT PIPE HEIGHT (H) VERSUS DISTANCE (D) REQUIREMENTS TABLE 2209.5.4.3.6(1) MAXIMUM RADIANT HEAT EXPOSURE TABLE 2209.5.4.3.6(2) MAXIMUM HYDROGEN CONCENTRATION EXPOSURE <\/td>\n<\/tr>\n | ||||||
220<\/td>\n | SECTION 2210 MARINE MOTOR FUEL\u00b7DISPENSING FACILITIES <\/td>\n<\/tr>\n | ||||||
222<\/td>\n | SECTION 2211 REPAIR GARAGES <\/td>\n<\/tr>\n | ||||||
226<\/td>\n | CHAPTER 23 HIGH-PILED COMBUSTIBLE STORAGE SECTION 2301 GENERAL SECTION 2302 DEFINITIONS <\/td>\n<\/tr>\n | ||||||
227<\/td>\n | SECTION 2303 COMMODITY CLASSIFICATION <\/td>\n<\/tr>\n | ||||||
229<\/td>\n | SECTION 2304 DESIGNATION OF HIGH-PILED STORAGE AREAS <\/td>\n<\/tr>\n | ||||||
230<\/td>\n | FIGURE 2303.7.4 MIXED COMMODITIESa b <\/td>\n<\/tr>\n | ||||||
231<\/td>\n | SECTION 2305 HOUSEKEEPING AND MAINTENANCE SECTION 2306 GENERAL FIRE PROTECTION AND LIFE SAFETY FEATURES <\/td>\n<\/tr>\n | ||||||
232<\/td>\n | TABLE 2306.2 GENERAL FIRE PROTECTION AND LIFE SAFETY REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
233<\/td>\n | SECTION 2307 SOLID-PILED AND SHELF STORAGE <\/td>\n<\/tr>\n | ||||||
234<\/td>\n | SECTION 2308 RACK STORAGE SECTION 2309 AUTOMATED STORAGE <\/td>\n<\/tr>\n | ||||||
235<\/td>\n | TABLE 2308.3 REQUIRED FLUE SPACES FOR RACK STORAGE SECTION 2310 SPECIALTY STORAGE <\/td>\n<\/tr>\n | ||||||
236<\/td>\n | CHAPTER 24 TENTS AND OTHER MEMBRANE STRUCTURES SECTION 2401 GENERAL SECTION 2402 DEFINITIONS SECTION 2403 TEMPORARY TENTS AND MEMBRANE STRUCTURES <\/td>\n<\/tr>\n | ||||||
238<\/td>\n | TABLE 2403.12.2 MINIMUM NUMBER OF MEANS OF EGRESS AND MEANS OF EGRESS WIDTHS FROM TEMPORARY MEMBRANE STRUCTURES AND TENTS <\/td>\n<\/tr>\n | ||||||
239<\/td>\n | SECTION 2404 TEMPORARY AND PERMANENT TENTS AND MEMBRANE STRUCTURES <\/td>\n<\/tr>\n | ||||||
242<\/td>\n | CHAPTER 25 VEHICLE SALVAGE, TIRE REBUILDING AND TIRE STORAGE SECTION 2501 GENERAL SECTION 2502 DEFINITIONS SECTION 2503 TIRE REBUILDING SECTION 2504 PRECAUTIONS AGAINST FIRE SECTION 2505 OUTDOOR STORAGE <\/td>\n<\/tr>\n | ||||||
243<\/td>\n | SECTION 2506 FIRE DEPARTMENT ACCESS SECTION 2507 FENCING SECTION 2508 FIRE PROTECTION SECTION 2509 INDOOR STORAGE ARRANGEMENT SECTION F-2510 VEHICLE SALVAGE AND WRECKING FACILITIES <\/td>\n<\/tr>\n | ||||||
246<\/td>\n | CHAPTER 26 WELDING AND OTHER HOT WORK SECTION 2601 GENERAL SECTION 2602 DEFINITIONS SECTION 2603 GENERAL REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
247<\/td>\n | SECTION 2604 FIRE SAFETY REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
248<\/td>\n | SECTION 2605 GAS WELDING AND CUTTING <\/td>\n<\/tr>\n | ||||||
249<\/td>\n | SECTION 2606 ELECTRIC ARC HOT WORK SECTION 2607 CALCIUM CARBIDE SYSTEMS SECTION 2608 ACETYLENE GENERATORS SECTION 2609 PIPING MANIFOLDS AND HOSE SYSTEMS FOR FUEL GASES AND OXYGEN <\/td>\n<\/tr>\n | ||||||
252<\/td>\n | CHAPTER 27 HAZARDOUS MATERIALS-GENERAL PROVISIONS SECTION 2701 GENERAL <\/td>\n<\/tr>\n | ||||||
259<\/td>\n | SECTION 2702 DEFINITIONS <\/td>\n<\/tr>\n | ||||||
262<\/td>\n | SECTION 2703 GENERAL REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
264<\/td>\n | TABLE F-2703.1.1(1) MAXIMUM ALLOWABLE QUANTITY PER INDOOR CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD <\/td>\n<\/tr>\n | ||||||
265<\/td>\n | TABLE F-2703.1.1(1)-continued MAXIMUM ALLOWABLE QUANTITY PER INDOOR CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD <\/td>\n<\/tr>\n | ||||||
266<\/td>\n | TABLE F-2703.1.1(1)-continued MAXIMUM ALLOWABLE QUANTITY PER INDOOR CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD <\/td>\n<\/tr>\n | ||||||
267<\/td>\n | TABLE F-2703.1.1(2) MAXIMUM ALLOWABLE QUANTITY PER INDOOR CONTROL AREA OF HAZARDOUS MATERIAL POSING A HEALTH HAZARD <\/td>\n<\/tr>\n | ||||||
268<\/td>\n | TABLE 2703.1.1(3) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD IN AN OUTDOOR CONTROL AREA <\/td>\n<\/tr>\n | ||||||
269<\/td>\n | TABLE 2703.1.1(4) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A HEALTH HAZARD IN AN OUTDOOR CONTROL AREA <\/td>\n<\/tr>\n | ||||||
273<\/td>\n | TABLE 2703.8.2 DETACHED BUILDING REQUIRED TABLE 2703.8.3.2 DESIGN AND NUMBER OF CONTROL AREAS <\/td>\n<\/tr>\n | ||||||
277<\/td>\n | TABLE 2703.11.1 MAXIMUM ALLOWABLE QUANTITY PER INDOOR AND OUTDOOR CONTROL AREA IN GROUP M AND S OCCUPANCIES NONFLAMMABLE SOLIDS, NONFLAMMABLE AND NONCOMBUSTIBLE LIQUIDS d,e,f <\/td>\n<\/tr>\n | ||||||
278<\/td>\n | SECTION 2704 STORAGE <\/td>\n<\/tr>\n | ||||||
279<\/td>\n | TABLE 2704.2.2 REQUIRED SECONDARY CONTAINMENT-HAZARDOUS MATERIAL SOLIDS AND LIQUIDS STORAGE <\/td>\n<\/tr>\n | ||||||
282<\/td>\n | SECTION 2705 USE, DISPENSING AND HANDLING <\/td>\n<\/tr>\n | ||||||
284<\/td>\n | TABLE 2705.2.1.4 REQUIRED SECONDARY CONTAINMENT-HAZARDOUS MATERIAL LIQUIDS USE <\/td>\n<\/tr>\n | ||||||
288<\/td>\n | CHAPTER 28 AEROSOLS SECTION 2801 GENERAL SECTION 2802 DEFINITIONS SECTION 2803 CLASSIFICATION OF AEROSOL PRODUCTS TABLE 2803.1 CLASSIFICATION OF AEROSOL PRODUCTS SECTION 2804 INSIDE STORAGE OF AEROSOL PRODUCTS <\/td>\n<\/tr>\n | ||||||
289<\/td>\n | TABLE 2804.3.1 NONSEGREGATED STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN GENERAL PURPOSE WAREHOUSESb <\/td>\n<\/tr>\n | ||||||
290<\/td>\n | TABLE 2804.3.2 SEGREGATED STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN GENERAL PURPOSE WAREHOUSES TABLE 2804.3.2.2 SEGREGATED STORAGE AISLE WIDTHS AND DISTANCE TO AISLES IN GENERAL PURPOSE WAREHOUSES <\/td>\n<\/tr>\n | ||||||
291<\/td>\n | TABLE 2804.7 MAXIMUM QUANTITIES OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN RETAIL STORAGE AREAS SECTION 2805 OUTSIDE STORAGE TABLE 2805.1 DISTANCE TO EXPOSURES FOR OUTSIDE STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS SECTION 2806 RETAIL DISPLAY TABLE 2806.2.1 MAXIMUM QUANTITIES OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN RETAIL DISPLAY AREAS <\/td>\n<\/tr>\n | ||||||
293<\/td>\n | TABLE 2806.4 MAXIMUM STORAGE QUANTITIES FOR STORAGE AREAS ADJACENT TO RETAIL DISPLAY OF LEVEL 2 AND 3 AEROSOLS SECTION 2807 MANUFACTURING FACILITIES <\/td>\n<\/tr>\n | ||||||
294<\/td>\n | CHAPTER 29 COMBUSTIBLE FIBERS SECTION 2901 GENERAL SECTION 2902 DEFINITIONS SECTION 2903 GENERAL PRECAUTIONS SECTION 2904 LOOSE FIBER STORAGE <\/td>\n<\/tr>\n | ||||||
295<\/td>\n | SECTION 2905 BALED STORAGE <\/td>\n<\/tr>\n | ||||||
296<\/td>\n | CHAPTER 30 COMPRESSED GASES SECTION 3001 GENERAL SECTION 3002 DEFINITIONS <\/td>\n<\/tr>\n | ||||||
297<\/td>\n | SECTION 3003 GENERAL REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
301<\/td>\n | SECTION 3004 STORAGE OF COMPRESSED GASES SECTION 3005 USE AND HANDLING OF COMPRESSED GASES <\/td>\n<\/tr>\n | ||||||
302<\/td>\n | SECTION 3006 MEDICAL GAS SYSTEMS <\/td>\n<\/tr>\n | ||||||
303<\/td>\n | SECTION 3007 COMPRESSED GASES NOT OTHERWISE REGULATED <\/td>\n<\/tr>\n | ||||||
304<\/td>\n | CHAPTER 31 CORROSIVE MATERIALS SECTION 3101 GENERAL SECTION 3102 DEFINITIONS SECTION 3103 GENERAL REQUIREMENTS SECTION 3104 STORAGE SECTION 3105 USE <\/td>\n<\/tr>\n | ||||||
306<\/td>\n | CHAPTER 32 CRYOGENIC FLUIDS SECTION 3201 GENERAL SECTION 3202 DEFINITIONS SECTION 3203 GENERAL REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
308<\/td>\n | SECTION 3204 STORAGE <\/td>\n<\/tr>\n | ||||||
309<\/td>\n | TABLE 3204.3.1.1 SEPARATION OF STATIONARY CONTAINERS FROM EXPOSURE HAZARDS TABLE 3204.3.1.2.1 SEPARATION OF PORTABLE CONTAINERS FROM EXPOSURE HAZARDS <\/td>\n<\/tr>\n | ||||||
310<\/td>\n | SECTION 3205 USE AND HANDLING <\/td>\n<\/tr>\n | ||||||
312<\/td>\n | CHAPTER 33 EXPLOSIVES AND FIREWORKS SECTION 3301 GENERAL <\/td>\n<\/tr>\n | ||||||
315<\/td>\n | TABLE 3301.8.1(1) APPLICATION OF SEPARATION DISTANCE (Q-D) TABLES – DIVISION 1.1, 1.2 AND 1.5 EXPLOSIVES a,b,c <\/td>\n<\/tr>\n | ||||||
316<\/td>\n | TABLE 3301.8.1(2) APPLICATION OF SEPARATION DISTANCE (Q-D) TABLES – DIVISION 1.3 EXPLOSIVES a,b,c TABLE 3301.8.1 (3) APPLICATION OF SEPARATION DISTANCE (Q-D) TABLES-DIVISION 1.4 EXPLOSIVES a,b,c,d SECTION 3302 DEFINITIONS <\/td>\n<\/tr>\n | ||||||
320<\/td>\n | SECTION 3303 RECORD KEEPING AND REPORTING SECTION 3304 EXPLOSIVE MATERIALS STORAGE AND HANDLING <\/td>\n<\/tr>\n | ||||||
321<\/td>\n | TABLE 3304.3 STORAGE AMOUNTS AND MAGAZINE REQUIREMENTS FOR EXPLOSIVES, EXPLOSIVE MATERIALS AND FIREWORKS, 1.3G MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA <\/td>\n<\/tr>\n | ||||||
323<\/td>\n | TABLE 3304.5.2(1) (Referenced in Section 3301.8.1.1) AMERICAN TABLE OF DISTANCES FOR STORAGE OF EXPLOSIVES AS APPROVED BY THE INSTITUTE OF MAKERS OF EXPLOSIVES AND REVISED JUNE 1991 a <\/td>\n<\/tr>\n | ||||||
324<\/td>\n | TABLE 3304.5.2(1)-continued AMERICAN TABLE OF DISTANCES FOR STORAGE OF EXPLOSIVES AS APPROVED BY THE INSTITUTE OF MAKERS OF EXPLOSIVES AND REVISED JUNE 1991\u00b7a <\/td>\n<\/tr>\n | ||||||
325<\/td>\n | TABLE 3304.5.2(2) TABLE OF DISTANCES (Q-D) FOR BUILDINGS CONTAINING EXPLOSIVES – DIVISION 1.3 MASS-FIRE HAZARDa.b,c TABLE 3304.5.2(3) TABLE OF DISTANCES (Q-D) FOR BUILDINGS CONTAINING EXPLOSIVES -DIVISION 1.4c <\/td>\n<\/tr>\n | ||||||
327<\/td>\n | SECTION 3305 MANUFACTURE, ASSEMBLY AND TESTING OF EXPLOSIVES, EXPLOSIVE MATERIALS AND FIREWORKS <\/td>\n<\/tr>\n | ||||||
328<\/td>\n | TABLE 3305.3 MINIMUM INTRALINE (INTRAPLANT) SEPARATION DISTANCES (ILD OR IPD) BETWEEN BARRICADED OPERATING BUILDINGS CONTAINING EXPLOSIVES – DIVISION 1.1, 1.2 OR 1.5 – MASS EXPLOSION HAZARDa <\/td>\n<\/tr>\n | ||||||
330<\/td>\n | SECTION 3306 SMALL ARMS AMMUNITION <\/td>\n<\/tr>\n | ||||||
332<\/td>\n | SECTION 3307 BLASTING <\/td>\n<\/tr>\n | ||||||
333<\/td>\n | SECTION 3308 FIREWORKS DISPLAY <\/td>\n<\/tr>\n | ||||||
335<\/td>\n | SECTION 3309 TEMPORARY STORAGE OF CONSUMER FIREWORKS <\/td>\n<\/tr>\n | ||||||
336<\/td>\n | CHAPTER 34 FLAMMABLE AND COMBUSTIBLE LIQUIDS SECTION 3401 GENERAL SECTION 3402 DEFINITIONS <\/td>\n<\/tr>\n | ||||||
337<\/td>\n | SECTION 3403 GENERAL REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
338<\/td>\n | TABLE 3403.1.1 CLASS I ELECTRICAL EQUIPMENT LOCATIONS <\/td>\n<\/tr>\n | ||||||
339<\/td>\n | TABLE 3403.1.1-continued CLASS I ELECTRICAL EQUIPMENT LOCATIONS <\/td>\n<\/tr>\n | ||||||
340<\/td>\n | TABLE 3403.6.2 PIPING STANDARDS <\/td>\n<\/tr>\n | ||||||
341<\/td>\n | SECTION 3404 STORAGE <\/td>\n<\/tr>\n | ||||||
355<\/td>\n | TABLE 3404.3.4.1 MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN WHOLESALE AND RETAIL SALES OCCUPANCIES a <\/td>\n<\/tr>\n | ||||||
357<\/td>\n | TABLE 3404.3.6.3(1) MAXIMUM STORAGE HEIGHT IN CONTROL AREA TABLE 3404.3.6.3(2) STORAGE ARRANGEMENTS FOR PALLETIZED OR SOLID-PILE STORAGE IN LIQUID STORAGE ROOMS AND WAREHOUSES <\/td>\n<\/tr>\n | ||||||
358<\/td>\n | TABLE 3404.3.6.3(3) STORAGE ARRANGEMENTS FOR RACK STORAGE IN LIQUID STORAGE ROOMS AND WAREHOUSES TABLE 3404.3.6.3(4) AUTOMATIC SPRINKLER PROTECTION FOR SOLID-PILE AND PALLETIZED STORAGE OF LIQUIDS IN METAL CONTAINERS AND PORTABLE TANKS\u00b7a <\/td>\n<\/tr>\n | ||||||
359<\/td>\n | TABLE 3404.3.6.3(5) AUTOMATIC SPRINKLER PROTECTION REQUIREMENTS FOR RACK STORAGE OF LIQUIDS IN METAL CONTAINERS OF 5-GALLON CAPACITY OR LESS WITH OR WITHOUT CARTONS ON CONVENTIONAL WOOD PALLETS <\/td>\n<\/tr>\n | ||||||
360<\/td>\n | TABLE 3404.3.6.3(6) AUTOMATIC SPRINKLER PROTECTION REQUIREMENTS FOR RACK STORAGE OF LIQUIDS IN METAL CONTAINERS GREATER THAN 5-GALLON CAPACITY <\/td>\n<\/tr>\n | ||||||
361<\/td>\n | TABLE 3404.3.6.3(7) AUTOMATIC AFFF WATER PROTECTION REQUIREMENTS FOR RACK STORAGE OF LIQUIDS IN METAL CONTAINERS GREATER THAN 5-GALLON CAPACITY TABLE 3404.3.6.3(8) AUTOMATIC SPRINKLER PROTECTION REQUIREMENTS FOR CLASS I LIQUIDS STORAGE IN METAL CONTAINERS OF 1-GALLON CAPACITY OR LESS WITH UNCARTONED OR CASE-CUT SHELF DISPLAY UP TO 6.5 FEET AND PALLETIZED STORAGE ABOVE IN A DOUBLE-ROW RACK ARRAY <\/td>\n<\/tr>\n | ||||||
363<\/td>\n | TABLE 3404.3.7.5.1 AUTOMATIC AFFF-WATER PROTECTION REQUIREMENTS FOR SOLID-PILE AND PALLETIZED STORAGE OF LIQUIDS IN METAL CONTAINERS OF 5-GALLON CAPACITY OR LESS\u00b7\u00b7b <\/td>\n<\/tr>\n | ||||||
364<\/td>\n | TABLE 3404.4.2 OUTDOOR LIQUID STORAGE IN CONTAINERS AND PORTABLE TANKS <\/td>\n<\/tr>\n | ||||||
365<\/td>\n | SECTION 3405 DISPENSING, USE, MIXING AND HANDLING <\/td>\n<\/tr>\n | ||||||
367<\/td>\n | TABLE 3405.3.4(1) SEPARATION OF PROCESSING VESSELS FROM LOT LINES TABLE 3405.3.4(2) REFERENCE TABLE FOR USE WITH TABLE 3405.3.4(1) <\/td>\n<\/tr>\n | ||||||
370<\/td>\n | TABLE 3405.3.8.2 MAXIMUM ALLOWABLE QUANTITIES FOR DISPENSING OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN OUTDOOR CONTROL AREAS a,b <\/td>\n<\/tr>\n | ||||||
371<\/td>\n | SECTION 3406 SPECIAL OPERATIONS <\/td>\n<\/tr>\n | ||||||
384<\/td>\n | CHAPTER 35 FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS SECTION 3501 GENERAL SECTION 3502 DEFINITIONS SECTION 3503 GENERAL REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
385<\/td>\n | SECTION 3504 STORAGE <\/td>\n<\/tr>\n | ||||||
386<\/td>\n | TABLE 3504.2.1 FLAMMABLE GASES-DISTANCE FROM STORAGE TO EXPOSURES SECTION 3505 USE SECTION 3506 FLAMMABLE CRYOGENIC FLUIDS <\/td>\n<\/tr>\n | ||||||
387<\/td>\n | SECTION 3507 METAL HYDRIDE STORAGE SYSTEMS <\/td>\n<\/tr>\n | ||||||
390<\/td>\n | CHAPTER 36 FLAMMABLE SOLIDS SECTION 3601 GENERAL SECTION 3602 DEFINITIONS SECTION 3603 GENERAL REQUIREMENTS SECTION 3604 STORAGE SECTION 3605 USE <\/td>\n<\/tr>\n | ||||||
391<\/td>\n | SECTION 3606 MAGNESIUM <\/td>\n<\/tr>\n | ||||||
394<\/td>\n | CHAPTER 37 HIGHLY TOXIC AND TOXIC MATERIALS SECTION 3701 GENERAL SECTION 3702 DEFINITIONS <\/td>\n<\/tr>\n | ||||||
395<\/td>\n | SECTION 3703 HIGHLY TOXIC AND TOXIC SOLIDS AND LIQUIDS <\/td>\n<\/tr>\n | ||||||
396<\/td>\n | SECTION 3704 HIGHLY TOXIC AND TOXIC COMPRESSED GASES <\/td>\n<\/tr>\n | ||||||
399<\/td>\n | TABLE 3704.2.2.7.5 RATE OF RELEASE FOR CYLINDERS AND PORTABLE TANKS <\/td>\n<\/tr>\n | ||||||
401<\/td>\n | SECTION 3705 OZONE GAS GENERATORS <\/td>\n<\/tr>\n | ||||||
404<\/td>\n | CHAPTER 38 LIQUEFIED PETROLEUM GASES SECTION 3801 GENERAL SECTION 3802 DEFINITIONS SECTION 3803 INSTALLATION OF EQUIPMENT <\/td>\n<\/tr>\n | ||||||
405<\/td>\n | SECTION 3804 LOCATION OF LP-GAS CONTAINERS SECTION 3805 PROHIBITED USE OF LP-GAS <\/td>\n<\/tr>\n | ||||||
406<\/td>\n | TABLE 3804.3 LOCATION OF LP-GAS CONTAINERS SECTION 3806 DISPENSING AND OVERFILLING SECTION 3807 SAFETY PRECAUTIONS AND DEVICES <\/td>\n<\/tr>\n | ||||||
407<\/td>\n | SECTION 3808 FIRE PROTECTION SECTION 3809 STORAGE OF PORTABLE LP-GAS CONTAINERS AWAITING USE OR RESALE <\/td>\n<\/tr>\n | ||||||
408<\/td>\n | TABLE 3809.12 SEPARATION FROM EXPOSURES OF LP-GAS CONTAINERS AWAITING USE, RESALE OR EXCHANGE STORED OUTSIDE OF BUILDINGS SECTION 3810 LP-GAS CONTAINERS NOT IN SERVICE <\/td>\n<\/tr>\n | ||||||
409<\/td>\n | SECTION 3811 PARKING AND GARAGING <\/td>\n<\/tr>\n | ||||||
410<\/td>\n | CHAPTER 39 ORGANIC PEROXIDES SECTION 3901 GENERAL SECTION 3902 DEFINITIONS SECTION 3903 GENERAL REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
411<\/td>\n | SECTION 3904 STORAGE <\/td>\n<\/tr>\n | ||||||
412<\/td>\n | TABLE 3904.1.2 ORGANIC PEROXIDES-DISTANCE TO EXPOSURES FROM DETACHED STORAGE BUILDINGS OR OUTDOOR STORAGE AREAS TABLE 3904.1.7 STORAGE OF ORGANIC PEROXIDES SECTION 3905 USE <\/td>\n<\/tr>\n | ||||||
414<\/td>\n | CHAPTER 40 OXIDIZERS, OXIDIZING GASES AND OXIDIZING CRYOGENIC FLUIDS SECTION 4001 GENERAL SECTION 4002 DEFINITIONS SECTION 4003 GENERAL REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
415<\/td>\n | SECTION 4004 STORAGE <\/td>\n<\/tr>\n | ||||||
416<\/td>\n | TABLE 4004.1.2 OXIDIZER LIQUIDS AND SOLIDS-DISTANCE FROM DETACHED BUILDINGS AND OUTDOOR STORAGE AREAS TO EXPOSURES TABLE 4004.1.7(1) STORAGE OF CLASS 1 OXIDIZER LIQUIDS AND SOLIDS IN COMBUSTIBLE CONTAINERSa TABLE 4004.1.7(2) STORAGE OF CLASS 2 OXIDIZER LIQUIDS AND SOLlDSa,b <\/td>\n<\/tr>\n | ||||||
417<\/td>\n | TABLE 4004.1.7(3) STORAGE OF CLASS 3 OXIDIZER LIQUIDS AND SOLlDSa,b TABLE 4004.1.7(4) STORAGE OF CLASS 4 OXIDIZER LIQUIDS AND SOLIDS SECTION 4005 USE SECTION 4006 LIQUID OXYGEN IN HOME HEALTH CARE <\/td>\n<\/tr>\n | ||||||
418<\/td>\n | TABLE 4004.2.2 OXIDIZER GASES-DISTANCE FROM STORAGE TO EXPOSURES\u00b7 <\/td>\n<\/tr>\n | ||||||
420<\/td>\n | CHAPTER 41 PYROPHORIC MATERIALS SECTION 4101 GENERAL SECTION 4102 DEFINITIONS SECTION 4103 GENERAL REQUIREMENTS SECTION 4104 STORAGE <\/td>\n<\/tr>\n | ||||||
421<\/td>\n | TABLE 4104.2.1 PYROPHORIC GASES-DISTANCE FROM STORAGE TO EXPOSURES\u00b7 SECTION 4105 USE <\/td>\n<\/tr>\n | ||||||
422<\/td>\n | CHAPTER 42 PYROXYLIN (CELLULOSE NITRATE) PLASTICS SECTION 4201 GENERAL SECTION 4202 DEFINITIONS SECTION 4203 GENERAL REQUIREMENTS SECTION 4204 STORAGE AND HANDLING <\/td>\n<\/tr>\n | ||||||
424<\/td>\n | CHAPTER 43 UNSTABLE (REACTIVE) MATERIALS SECTION 4301 GENERAL SECTION 4302 DEFINITIONS SECTION 4303 GENERAL REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
425<\/td>\n | SECTION 4304 STORAGE SECTION 4305 USE <\/td>\n<\/tr>\n | ||||||
426<\/td>\n | CHAPTER 44 WATER-REACTIVE SOLIDS AND LIQUIDS SECTION 4401 GENERAL SECTION 4402 DEFINITIONS SECTION 4403 GENERAL REQUIREMENTS SECTION 4404 STORAGE <\/td>\n<\/tr>\n | ||||||
427<\/td>\n | SECTION 4405 USE <\/td>\n<\/tr>\n | ||||||
428<\/td>\n | CHAPTER 45 MARINAS SECTION 4501 GENERAL SECTION 4502 DEFINITIONS SECTION 4503 GENERAL PRECAUTIONS SECTION 4504 FIRE PROTECTION EQUIPMENT <\/td>\n<\/tr>\n | ||||||
429<\/td>\n | SECTION 4505 MARINE MOTOR FUEL-DISPENSING FACILITIES <\/td>\n<\/tr>\n | ||||||
430<\/td>\n | CHAPTER 46 RESERVED <\/td>\n<\/tr>\n | ||||||
432<\/td>\n | CHAPTER 47 REFERENCED STANDARDS AASHTO AFSI API <\/td>\n<\/tr>\n | ||||||
433<\/td>\n | ASME ASTM <\/td>\n<\/tr>\n | ||||||
434<\/td>\n | BHMA CA CGA <\/td>\n<\/tr>\n | ||||||
435<\/td>\n | CGR CPSC DOC DOL <\/td>\n<\/tr>\n | ||||||
436<\/td>\n | DOTn DOTy EN <\/td>\n<\/tr>\n | ||||||
437<\/td>\n | EPA FCC ICC <\/td>\n<\/tr>\n | ||||||
438<\/td>\n | ISO NEMA <\/td>\n<\/tr>\n | ||||||
439<\/td>\n | NFPA <\/td>\n<\/tr>\n | ||||||
441<\/td>\n | UL <\/td>\n<\/tr>\n | ||||||
442<\/td>\n | USC <\/td>\n<\/tr>\n | ||||||
444<\/td>\n | APPENDIX A BOARD OF APPEALS SECTION A101 GENERAL <\/td>\n<\/tr>\n | ||||||
446<\/td>\n | APPENDIX B FIRE-FLOW REQUIREMENTS FOR BUILDINGS SECTION B101 GENERAL SECTION B102 DEFINITIONS SECTION B103 MODIFICATIONS SECTION B104 FIRE-FLOW CALCULATION AREA SECTION B105 FIRE-FLOW REQUIREMENTS FOR BUILDINGS <\/td>\n<\/tr>\n | ||||||
447<\/td>\n | TABLE B105.1 MINIMUM REQUIRED FIRE-FLOW AND FLOW DURATION FOR BUILDINGS SECTION B106 REFERENCED STANDARDS <\/td>\n<\/tr>\n | ||||||
448<\/td>\n | APPENDIX C FIRE HYDRANT LOCATIONS AND DISTRIBUTION SECTION C101 GENERAL SECTION C102 LOCATION SECTION C103 NUMBER OF FIRE HYDRANTS SECTION C104 CONSIDERATION OF EXISTING FIRE HYDRANTS SECTION C105 DISTRIBUTION OF FIRE HYDRANTS TABLE C105.1 NUMBER AND DISTRIBUTION OF FIRE HYDRANTS <\/td>\n<\/tr>\n | ||||||
450<\/td>\n | APPENDIX D FIRE APPARATUS ACCESS ROADS SECTION D101 GENERAL SECTION D102 REQUIRED ACCESS SECTION D103 MINIMUM SPECIFICATIONS TABLE D103.4 REQUIREMENTS FOR DEAD-END FIRE APPARATUS ACCESS ROADS FIGURE D103.1 DEAD-END FIRE APPARATUS ACCESS ROAD TURNAROUND <\/td>\n<\/tr>\n | ||||||
451<\/td>\n | FIGURE D103.6 FIRE LANE SIGNS SECTION D104 COMMERCIAL AND INDUSTRIAL DEVELOPMENTS SECTION D105 AERIAL FIRE APPARATUS ACCESS ROADS <\/td>\n<\/tr>\n | ||||||
452<\/td>\n | SECTION D106 MULTIPLE-FAMILY RESIDENTIAL DEVELOPMENTS SECTION D107 ONE- OR TWO-FAMILY RESIDENTIAL DEVELOPMENTS SECTION D108 REFERENCED STANDARDS <\/td>\n<\/tr>\n | ||||||
454<\/td>\n | APPENDIX E HAZARD CATEGORIES SECTION E101 GENERAL SECTION E102 HAZARD CATEGORIES <\/td>\n<\/tr>\n | ||||||
459<\/td>\n | SECTION E103 EVALUATION OF HAZARDS <\/td>\n<\/tr>\n | ||||||
460<\/td>\n | E104 REFERENCED STANDARDS <\/td>\n<\/tr>\n | ||||||
462<\/td>\n | APPENDIX F HAZARD RANKING SECTION F101 GENERAL SECTION F102 REFERENCED STANDARDS <\/td>\n<\/tr>\n | ||||||
463<\/td>\n | TABLE F101.2 FIRE FIGHTER WARNING PLACARD DESIGNATIONS BASED ON HAZARD CLASSIFICATION CATEGORIES <\/td>\n<\/tr>\n | ||||||
464<\/td>\n | APPENDIX G CRYOGENIC FLUIDS – WEIGHT AND VOLUME EQUIVALENTS SECTION G101 GENERAL <\/td>\n<\/tr>\n | ||||||
465<\/td>\n | TABLE G101.2 WEIGHT AND VOLUME EQUIVALENTS FOR COMMON CRYOGENIC FLUIDS <\/td>\n<\/tr>\n | ||||||
466<\/td>\n | APPENDIX H HAZARDOUS MATERIALS MANAGEMENT PLAN (HMMP) AND HAZARDOUS MATERIALS INVENTORY STATEMENT (HMIS) INSTRUCTIONS SECTION H101 HMMP SECTION H102 HMIS <\/td>\n<\/tr>\n | ||||||
467<\/td>\n | SECTION H103 EMERGENCY PLAN SECTION H104 REFERENCED STANDARDS <\/td>\n<\/tr>\n | ||||||
468<\/td>\n | FIGURE 1 HAZARDOUS MATERIALS MANAGEMENT PLAN SECTION I: FACILITY DESCRIPTION <\/td>\n<\/tr>\n | ||||||
469<\/td>\n | FIGURE 2 HAZARDOUS MATERIALS MANAGEMENT PLAN SECTION I: FACILITY DESCRIPTION <\/td>\n<\/tr>\n | ||||||
470<\/td>\n | FIGURE 3 HAZARDOUS MATERIALS MANAGEMENT PLAN <\/td>\n<\/tr>\n | ||||||
471<\/td>\n | FIGURE 4 SECTION II – HAZARDOUS MATERIALS INVENTORY STATEMENT (HMIS) HMIS SUMMARY REPORT <\/td>\n<\/tr>\n | ||||||
472<\/td>\n | FIGURE 5 SECTION II – HAZARDOUS MATERIALS INVENTORY STATEMENT (HMIS) HMIS INVENTORY REPORT <\/td>\n<\/tr>\n | ||||||
473<\/td>\n | FIGURE 6 HAZARDOUS MATERIALS MANAGEMENT PLAN SECTION III: EMERGENCY PLAN <\/td>\n<\/tr>\n | ||||||
474<\/td>\n | APPENDIX I FIRE PROTECTION SYSTEMS-NONCOMPLIANT CONDITIONS SECTION I101 NONCOMPLIANT CONDITIONS <\/td>\n<\/tr>\n | ||||||
475<\/td>\n | SECTION I102 REFERENCED STANDARDS <\/td>\n<\/tr>\n | ||||||
476<\/td>\n | APPENDIX J RESERVED <\/td>\n<\/tr>\n | ||||||
478<\/td>\n | APPENDIX K ELEVATOR CALL STATION PICTOGRAPH FIGURE ELEVATOR CALL STATION PICTOGRAPH FIGURE HIGH-RISE BUILDING ELEVATOR CALL STATION FLOOR DIAGRAM <\/td>\n<\/tr>\n | ||||||
480<\/td>\n | INDEX <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" The City of Philadelphia Fire Code<\/b><\/p>\n |