{"id":161757,"date":"2024-10-19T09:43:21","date_gmt":"2024-10-19T09:43:21","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/asme-a17-1-2016\/"},"modified":"2024-10-25T02:01:18","modified_gmt":"2024-10-25T02:01:18","slug":"asme-a17-1-2016","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/asme\/asme-a17-1-2016\/","title":{"rendered":"ASME A17.1 2016"},"content":{"rendered":"

ASME A17.1-2016\/CSA B44-16?one of ASME\u2019s most requested safety standards?addresses elevators, escalators, dumbwaiters, moving walks and material lifts. It provides requirements applying to the design, construction, installation, operation, testing, inspection, maintenance, alteration and repair of these conveyances. This living landmark has been defining safety in elevators, escalators and related equipment since 1921. A17.1 has been harmonized with CSA B44 to provide one comprehensive solution for jurisdictions throughout North America. Major changes and updates for the 2016 edition include: \u2022 seismic requirements for escalators; \u2022 special purpose personnel elevators; \u2022 rack and pinion elevators; \u2022 residence elevators; \u2022 material lifts with obscured transfer devices; and \u2022 addition of elastomeric buffer requirements. Intended for anyone engaged in the safety of elevators, escalators and related conveyances, including those responsible for: design, engineering and manufacture; installation, operation, testing, maintenance, alteration and repair; inspection; plans, contracts, administration, insurance and liability; property, facilities and plant management; and emergency response.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
4<\/td>\nCONTENTS <\/td>\n<\/tr>\n
6<\/td>\nFigures <\/td>\n<\/tr>\n
7<\/td>\nTables <\/td>\n<\/tr>\n
9<\/td>\nASME FOREWORD <\/td>\n<\/tr>\n
14<\/td>\nASME A17 COMMITTEE ROSTER
STANDARDS COMMITTEE
Honorary Members
Regulatory Advisory Council <\/td>\n<\/tr>\n
15<\/td>\n NATIONAL INTEREST REVIEW GROUP
B44.1\/A17.5 ELEVATOR AND ESCALATOR ELECTRICAL EQUIPMENT COMMITTEE
CODE COORDINATION COMMITTEE
DUMBWAITER AND ATD COMMITTEE
EARTHQUAKE SAFETY COMMITTEE
EDITORIAL COMMITTEE
ELECTRICAL COMMITTEE
ELEVATORS USED FOR CONSTRUCTION COMMITTEE <\/td>\n<\/tr>\n
16<\/td>\n EMERGENCY OPERATIONS COMMITTEE
EMERGENCY PERSONNEL COMMITTEE
ESCALATOR AND MOVING WALK COMMITTEE
EXISTING INSTALLATIONS COMMITTEE
HAND AND SIDEWALK ELEVATOR COMMITTEE <\/td>\n<\/tr>\n
17<\/td>\n HOISTWAY COMMITTEE
HYDRAULIC COMMITTEE
INCLINED ELEVATOR COMMITTEE
INSPECTIONS COMMITTEE
INTERNATIONAL STANDARDS COMMITTEE <\/td>\n<\/tr>\n
18<\/td>\n LIMITED-USE\/LIMITED-APPLICATION ELEVATOR COMMITTEE
MAINTENANCE, REPAIR, AND REPLACEMENT COMMITTEE
MARINE ELEVATOR COMMITTEE
MECHANICAL DESIGN COMMITTEE
MINE ELEVATOR COMMITTEE
NEW TECHNOLOGY COMMITTEE <\/td>\n<\/tr>\n
19<\/td>\n OUTSIDE EMERGENCY ELEVATOR COMMITTEE
QUALIFICATION OF ELEVATOR INSPECTORS QEI COMMITTEE
RACK-AND-PINION AND SPECIAL PURPOSE PERSONNEL ELEVATOR COMMITTEE
RESIDENCE ELEVATOR COMMITTEE
WIND TURBINE ELEVATOR COMMITTEE <\/td>\n<\/tr>\n
20<\/td>\nCSA B44 COMMITTEE ON THE ELEVATOR SAFETY CODE
TECHNICAL COMMITTEE
Associate Members
CSA B44.1\/ASME A17.5 JOINT COMMITTEE ON ELEVATOR AND ESCALATOR ELECTRICAL EQUIPMENT <\/td>\n<\/tr>\n
22<\/td>\nASME PREFACE
GENERAL
APPLICATION OF REQUIREMENTS TO NEW TECHNOLOGY
FORM AND ARRANGEMENT
METRIC SI UNITS
ASME ELEVATOR PUBLICATIONS <\/td>\n<\/tr>\n
23<\/td>\n CORRESPONDENCE WITH A17 COMMITTEE <\/td>\n<\/tr>\n
25<\/td>\nCSA PREFACE <\/td>\n<\/tr>\n
26<\/td>\nSUMMARY OF CHANGES <\/td>\n<\/tr>\n
36<\/td>\nSAFETY CODE FOR ELEVATORS AND ESCALATORS
Part 1 General
SECTION 1.1 SCOPE <\/td>\n<\/tr>\n
37<\/td>\nSECTION 1.2 PURPOSE AND EXCEPTIONS
SECTION 1.3 DEFINITIONS <\/td>\n<\/tr>\n
54<\/td>\nPart 2 Electric Elevators
SCOPE
SECTION 2.1 CONSTRUCTION OF HOISTWAYS AND HOISTWAY ENCLOSURES <\/td>\n<\/tr>\n
56<\/td>\nSECTION 2.2 PITS <\/td>\n<\/tr>\n
58<\/td>\nSECTION 2.3 LOCATION AND GUARDING OF COUNTERWElGHTS <\/td>\n<\/tr>\n
59<\/td>\nSECTION 2.4 VERTICAL CLEARANCES AND RUNBYS FOR CARS AND COUNTERWEIGHTS <\/td>\n<\/tr>\n
60<\/td>\nTable 2.4.2.2 Minimum Bottom Run by for Counterweight Elevators With Spring Buffers, Elastomeric Buffers, or Solid Bumpers and Rheostatic Control or Single-Speed AC Control <\/td>\n<\/tr>\n
61<\/td>\nSECTION 2.5 HORIZONTAL CAR AND COUNTERWEIGHT CLEARANCES <\/td>\n<\/tr>\n
62<\/td>\nSECTION 2.6 PROTECTION OF SPACE BELOW HOlSTWAYS
SECTION 2.7 MACHINERY SPACES, MACHINE ROOMS, CONTROL SPACES, AND CONTROL ROOMS <\/td>\n<\/tr>\n
70<\/td>\nSECTION 2.8 EQUIPMENT IN HOISTWAYS, MACHINERY SPACES, MACHINE ROOMS, CONTROL SPACES, AND CONTROL ROOMS <\/td>\n<\/tr>\n
72<\/td>\nSECTION 2.9 MACHINERY AND SHEAVE BEAMS, SUPPORTS, AND FOUNDATIONS <\/td>\n<\/tr>\n
74<\/td>\nSECTION 2.10 GUARDING OF EQUIPMENT AND STANDARD RAILING
SECTION 2.11 PROTECTION OF HOISTWAY OPENINGS <\/td>\n<\/tr>\n
82<\/td>\nSECTION 2.12 HOISTWAY DOOR LOCKING DEVICES AND ELECTRIC CONTACTS, AND HOISTWAY ACCESS SWITCHES <\/td>\n<\/tr>\n
87<\/td>\nSECTION 2.13 POWER OPERATION OF HOISTWAY DOORS AND CAR DOORS <\/td>\n<\/tr>\n
92<\/td>\nSECTION 2.14 CAR ENCLOSURES, CAR DOORS AND GATES, AND CAR ILLUMINATION <\/td>\n<\/tr>\n
102<\/td>\nSECTION 2.15 CAR FRAMES AND PLATFORMS <\/td>\n<\/tr>\n
105<\/td>\nSECTION 2.16 CAPACITY AND LOADING
Table 2.15.10.1 Maximum Allowable Stresses in Car Frame and Platform Members and Connections, for Steels Specified in 2.15.6.2.1 and 2.15.6.2.2 <\/td>\n<\/tr>\n
106<\/td>\nFig. 2.16.1.1 Inside Net Platform Areas for Passenger Elevators
Table 2.16.1.1 Maximum Inside Net Platform Areas for the Various Rated Loads <\/td>\n<\/tr>\n
110<\/td>\nSECTION 2.17 CAR AND COUNTERWEIGHT SAFETIES <\/td>\n<\/tr>\n
111<\/td>\nTable 2.17.3 Maximum and Minimum Stopping Distances for Type B Car Safeties With Rated Load and Type B Counterweight Safeties <\/td>\n<\/tr>\n
113<\/td>\nSECTION 2.18 SPEED GOVERNORS <\/td>\n<\/tr>\n
114<\/td>\nTable 2.18.2.1 Maximum Car Speeds at Which Speed Governor Trips and Governor Overspeed Switch Operates <\/td>\n<\/tr>\n
116<\/td>\nSECTION 2.19 ASCENDING CAR OVERSPEED AND UNINTENDED CAR MOVEMENT PROTECTION
Table 2.18.7.4 Multiplier for Determining Governor Sheave Pitch Diameter <\/td>\n<\/tr>\n
118<\/td>\nSECTION 2.20 SUSPENSION MEANS AND THEIR CONNECTIONS <\/td>\n<\/tr>\n
119<\/td>\nTable 2.20.3 Minimum Factors of Safety for Suspension Members <\/td>\n<\/tr>\n
123<\/td>\nFig. 2.20.9.4 Tapered Rope Sockets
Fig. 2.20.9.5 Wedge Rope Sockets
Table 2.20.9.4.5 Relation of Rope Diameter to Diameter of the Small Socket Hole <\/td>\n<\/tr>\n
127<\/td>\nSECTION 2.21 COUNTERWEIGHTS <\/td>\n<\/tr>\n
128<\/td>\nSECTION 2.22 BUFFERS AND BUMPERS
Table 2.22.3.1 Minimum Spring Buffer Strokes <\/td>\n<\/tr>\n
130<\/td>\nTable 2.22.4.1 Minimum Oil Buffer Strokes <\/td>\n<\/tr>\n
131<\/td>\nSECTION 2.23 CAR AND COUNTERWEIGHT GUIDE RAILS, GUIDE\u00c3RAIL SUPPORTS, AND FASTENINGS <\/td>\n<\/tr>\n
132<\/td>\nFig. 2.23.3 Elevator Guide Rails
Table 2.23.3 T-Section Guide-Rail Dimensions <\/td>\n<\/tr>\n
134<\/td>\nFig. 2.23.4.1-1 Maximum Weight of a Car With Rated Load or of Counterweight With Safety Device for a Pair of Guide Rails as Specified in 2.23.4.1 <\/td>\n<\/tr>\n
135<\/td>\nFig. 2.23.4.1-2 Minimum Moment of Inertia About x-x Axis for a Single Guide Rail With Its Reinforcement <\/td>\n<\/tr>\n
139<\/td>\nTable 2.23.4.3.1 Guide Rails for Counterweight Without Safeties
Table 2.23.4.3.3 Intermediate Tie Brackets <\/td>\n<\/tr>\n
140<\/td>\nSECTION 2.24 DRIVING MACHINES AND SHEAVES
Table 2.23.7.2.1 Minimum Thickness of Fishplates and Minimum Diameter of Fastening Bolts
Table 2.23.10.2 Minimum Size of Rail-Fastening Bolts <\/td>\n<\/tr>\n
143<\/td>\nSECTION 2.25 TERMINAL STOPPING DEVICES <\/td>\n<\/tr>\n
147<\/td>\nSECTION 2.26 OPERATING DEVICES AND CONTROL EQUIPMENT <\/td>\n<\/tr>\n
154<\/td>\nTable 2.26.4.3.2 SIL for Electrical Protective Devices and Other Electrical Safety Functions <\/td>\n<\/tr>\n
158<\/td>\nSECTION 2.27 EMERGENCY OPERATION AND SIGNALING DEVICES <\/td>\n<\/tr>\n
159<\/td>\nTable 2.26.12.1 Symbol Identification <\/td>\n<\/tr>\n
164<\/td>\nFig. 2.27.3.1.6(h) Visual Signal <\/td>\n<\/tr>\n
167<\/td>\nFig. 2.27.3.3.7 Panel Layout <\/td>\n<\/tr>\n
170<\/td>\nFig. 2.27.7.1 Phase I Emergency Recall Operation Instructions <\/td>\n<\/tr>\n
171<\/td>\nFig. 2.27.7.2 Phase II Emergency In-Car Operation <\/td>\n<\/tr>\n
172<\/td>\nFig. 2.27.8 FEO-K1 Key <\/td>\n<\/tr>\n
173<\/td>\nFig. 2.27.9 Elevator Corridor Call Station Pictograph <\/td>\n<\/tr>\n
175<\/td>\nSECTION 2.28 LAYOUT DRAWINGS
SECTION 2.29 IDENTIFICATION <\/td>\n<\/tr>\n
176<\/td>\nSECTION 2.30 SWAY CONTROL GUIDES <\/td>\n<\/tr>\n
177<\/td>\nPart 3 Hydraulic Elevators
SCOPE
SECTION 3.1 CONSTRUCTION OF HOISTWAYS AND HOISTWAY ENCLOSURES
SECTION 3.2 PITS
SECTION 3.3 LOCATION AND GUARDING OF COUNTERWEIGHTS
SECTION 3.4 BOTTOM AND TOP CLEARANCES AND RUNBYS FOR CARS AND COUNTERWEIGHTS <\/td>\n<\/tr>\n
178<\/td>\nSECTION 3.5 HORIZONTAL CAR AND COUNTERWEIGHT CLEARANCES
SECTION 3.6 PROTECTION OF SPACES BELOW HOISTWAY <\/td>\n<\/tr>\n
179<\/td>\nSECTION 3.7 MACHINERY SPACES, MACHINE ROOMS, CONTROL SPACES, AND CONTROL ROOMS
SECTION 3.8 ELECTRICAL EQUIPMENT, WIRING, PIPES, AND DUCTS IN HOISTWAY, MACHINERY SPACES, MACHINE ROOMS, CONTROL SPACES, AND CONTROL ROOMS
SECTION 3.9 MACHINERY AND SHEAVE BEAMS, SUPPORTS, AND FOUNDATIONS <\/td>\n<\/tr>\n
180<\/td>\nSECTION 3.10 GUARDING OF EXPOSED AUXILIARY EQUIPMENT
SECTION 3.11 PROTECTION OF HOISTWAY LANDING OPENINGS
SECTION 3.12 HOISTWAY DOOR LOCKING DEVICES, ELECTRIC CONTACTS, AND HOISTWAY ACCESS SWITCHES
SECTION 3.13 POWER OPERATION, POWER OPENING, AND POWER CLOSING OF HOISTWAY DOORS AND CAR DOORS OR GATES
SECTION 3.14 CAR ENCLOSURES, CAR DOORS AND GATES, AND CAR ILLUMINATION
SECTION 3.15 CAR FRAMES AND PLATFORMS <\/td>\n<\/tr>\n
181<\/td>\nSECTION 3.16 CAPACITY AND LOADING
SECTION 3.17 CAR SAFETIES, COUNTERWEIGHT SAFETIES, PLUNGER GRIPPER, AND GOVERNORS <\/td>\n<\/tr>\n
183<\/td>\nSECTION 3.18 HYDRAULIC JACKS <\/td>\n<\/tr>\n
185<\/td>\nSECTION 3.19 VALVES, PRESSURE PIPING, AND FITTINGS <\/td>\n<\/tr>\n
188<\/td>\nSECTION 3.20 ROPES AND ROPE CONNECTIONS
SECTION 3.21 COUNTERWEIGHTS
SECTION 3.22 BUFFERS AND BUMPERS <\/td>\n<\/tr>\n
189<\/td>\nSECTION 3.23 GUIDE RAILS, GUIDE-RAIL SUPPORTS, AND FASTENINGS
SECTION 3.24 HYDRAULIC MACHINES AND TANKS
SECTION 3.25 TERMINAL STOPPING DEVICES <\/td>\n<\/tr>\n
191<\/td>\nSECTION 3.26 OPERATING DEVICES AND CONTROL EQUIPMENT <\/td>\n<\/tr>\n
193<\/td>\nSECTION 3.27 EMERGENCY OPERATION AND SIGNALING DEVICES <\/td>\n<\/tr>\n
194<\/td>\nSECTION 3.28 LAYOUT DATA
SECTION 3.29 IDENTIFICATION <\/td>\n<\/tr>\n
195<\/td>\nPart 4 Elevators With Other Types of Driving Machines
SCOPE
SECTION 4.1 RACK-AND-PINION ELEVATORS <\/td>\n<\/tr>\n
199<\/td>\nTable 4.1.18.1 Maximum and Minimum Stopping Distances for Rack-and-Pinion Safeties With Rated Load <\/td>\n<\/tr>\n
202<\/td>\nSECTION 4.2 SCREW-COLUMN ELEVATORS <\/td>\n<\/tr>\n
205<\/td>\nSECTION 4.3 HAND ELEVATORS <\/td>\n<\/tr>\n
209<\/td>\nPart 5 Special Application Elevators
SCOPE
SECTION 5.1 INCLINED ELEVATORS <\/td>\n<\/tr>\n
213<\/td>\nTable 5.1.14.2 Minimum and Maximum Stopping Distances at Given Angles From Horizontal
Table 5.1.17.2 Spring Buffer Stroke <\/td>\n<\/tr>\n
214<\/td>\nFig. 5.1.17.3 Vertical and Horizontal Components of Velocity
Table 5.1.17.4.4 Minimum Oil Buffer Strokes at Given Angle From Horizontal <\/td>\n<\/tr>\n
215<\/td>\nSECTION 5.2 LIMITED-USE\/LIMITED-APPLICATION ELEVATORS <\/td>\n<\/tr>\n
229<\/td>\nSECTION 5.4 PRIVATE RESIDENCE INCLINED ELEVATORS <\/td>\n<\/tr>\n
232<\/td>\nSECTION 5.5 POWER SIDEWALK ELEVATORS <\/td>\n<\/tr>\n
236<\/td>\nSECTION 5.6 ROOFTOP ELEVATORS <\/td>\n<\/tr>\n
239<\/td>\nSECTION 5.7 SPECIAL PURPOSE PERSONNEL ELEVATORS <\/td>\n<\/tr>\n
247<\/td>\nSECTION 5.9 MINE ELEVATORS <\/td>\n<\/tr>\n
251<\/td>\nSECTION 5.10 ELEVATORS USED FOR CONSTRUCTION <\/td>\n<\/tr>\n
255<\/td>\nSECTION 5.11 WIND TURBINE TOWER ELEVATORS
SECTION 5.12 OUTSIDE EMERGENCY ELEVATORS <\/td>\n<\/tr>\n
257<\/td>\nPart 6 Escalators and Moving Walks
SCOPE
SECTION 6.1 ESCALATORS <\/td>\n<\/tr>\n
259<\/td>\nFig. 6.1.3.3.10 Dimensions <\/td>\n<\/tr>\n
268<\/td>\nFig. 6.1.6.9.1 Caution Sign <\/td>\n<\/tr>\n
270<\/td>\nSECTION 6.2 MOVING WALKS <\/td>\n<\/tr>\n
273<\/td>\nTable 6.2.3.7 Treadway Width <\/td>\n<\/tr>\n
275<\/td>\nTable 6.2.4 Treadway Speed <\/td>\n<\/tr>\n
281<\/td>\nPart 7 Dumbwaiters and Material Lifts
SCOPE
SECTION 7.1 POWER AND HAND DUMBWAITERS WITHOUT AUTOMATIC TRANSFER DEVICES <\/td>\n<\/tr>\n
286<\/td>\nSECTION 7.2 ELECTRIC AND HAND DUMBWAITERS WITHOUT AUTOMATIC TRANSFER DEVICES <\/td>\n<\/tr>\n
289<\/td>\nTable 7.2.6.4 Factors of Safety for Wire Rope andChains
Table 7.2.8.1 Minimum Spring Buffer Strokes <\/td>\n<\/tr>\n
290<\/td>\nTable 7.2.8.2 Minimum Oil Buffer Strokes <\/td>\n<\/tr>\n
292<\/td>\nSECTION 7.3 HYDRAULIC DUMBWAITERS WITHOUT AUTOMATIC TRANSFER DEVICES <\/td>\n<\/tr>\n
293<\/td>\nSECTION 7.4 MATERIAL LIFTS WITHOUT AUTOMATIC TRANSFER DEVICES <\/td>\n<\/tr>\n
294<\/td>\nTable 7.4.3 Type B Material Lifts <\/td>\n<\/tr>\n
297<\/td>\nSECTION 7.5 ELECTRIC MATERIAL LIFTS WITHOUT AUTOMATIC TRANSFER DEVICES <\/td>\n<\/tr>\n
303<\/td>\nSECTION 7.6 HYDRAULIC MATERIAL LIFTS WITHOUT AUTOMATIC TRANSFER DEVICES <\/td>\n<\/tr>\n
304<\/td>\nSECTION 7.7 AUTOMATIC TRANSFER DEVICES <\/td>\n<\/tr>\n
305<\/td>\nSECTION 7.8 POWER DUMBWAITERS WITH AUTOMATIC TRANSFER DEVICES
SECTION 7.9 ELECTRIC MATERIAL LIFTS WITH AUTOMATIC TRANSFER DEVICES <\/td>\n<\/tr>\n
306<\/td>\nTable 7.9.2.14 Minimum Spring Buffer Strokes <\/td>\n<\/tr>\n
307<\/td>\nSECTION 7.10 HYDRAULIC MATERIAL LIFTS WITH AUTOMATIC TRANSFER DEVICES
Table 7.9.2.15 Minimum Oil Buffer Strokes <\/td>\n<\/tr>\n
308<\/td>\nPart 8 General Requirements
SCOPE
SECTION 8.1 SECURITY <\/td>\n<\/tr>\n
309<\/td>\nSECTION 8.2 DESIGN DATA AND FORMULAS <\/td>\n<\/tr>\n
310<\/td>\nFig. 8.2.1.2 Minimum Rated Load for Passenger Elevators <\/td>\n<\/tr>\n
313<\/td>\nFig. 8.2.2.5.1 Turning Moment Based on Class of Loading <\/td>\n<\/tr>\n
315<\/td>\nFig. 8.2.4 Gravity Stopping Distances <\/td>\n<\/tr>\n
316<\/td>\nFig. 8.2.5 Maximum Governor Tripping Speeds <\/td>\n<\/tr>\n
318<\/td>\nFig. 8.2.6 Stopping Distances for Type B Car and Counterweight Safeties <\/td>\n<\/tr>\n
321<\/td>\nFig. 8.2.7 Minimum Factors of Safety of Suspension Members of Power Passenger and Freight Elevators <\/td>\n<\/tr>\n
323<\/td>\nFig. 8.2.8.1.1 Allowable Gross Loads <\/td>\n<\/tr>\n
327<\/td>\nFig. 8.2.9.1.3 Load Distribution <\/td>\n<\/tr>\n
328<\/td>\nSECTION 8.3 ENGINEERING TESTS, TYPE TESTS, AND CERTIFICATION <\/td>\n<\/tr>\n
339<\/td>\nSECTION 8.4 ELEVATOR SEISMIC REQUIREMENTS <\/td>\n<\/tr>\n
340<\/td>\nFig. 8.4.3.1.3 Arc of Contact <\/td>\n<\/tr>\n
343<\/td>\nFig. 8.4.8.2-1 12 kg\/m (8 lb\/ft) Guide-Rail Bracket Spacing <\/td>\n<\/tr>\n
344<\/td>\nFig. 8.4.8.2-2 16.5 kg\/m (11 lb\/ft) Guide-Rail Bracket Spacing <\/td>\n<\/tr>\n
345<\/td>\nFig. 8.4.8.2-3 18 kg\/m (12 lb\/ft) Guide-Rail Bracket Spacing <\/td>\n<\/tr>\n
346<\/td>\nFig. 8.4.8.2-4 22.5 kg\/m (15 lb\/ft) Guide-Rail Bracket Spacing <\/td>\n<\/tr>\n
347<\/td>\nFig. 8.4.8.2-5 27.5 kg\/m (18.5 lb\/ft) Guide-Rail Bracket Spacing <\/td>\n<\/tr>\n
348<\/td>\nFig. 8.4.8.2-6 33.5 kg\/m (22.5 lb\/ft) Guide-Rail Bracket Spacing <\/td>\n<\/tr>\n
349<\/td>\nFig. 8.4.8.2-7 44.5 kg\/m (30 lb\/ft) Guide-Rail Bracket Spacing <\/td>\n<\/tr>\n
350<\/td>\nFig. 8.4.8.2-8 Car and Counterweight Load Factor <\/td>\n<\/tr>\n
352<\/td>\nTable 8.4.8.7 Stresses and Deflections of Guide-Rail Brackets and Supports <\/td>\n<\/tr>\n
354<\/td>\nFig. 8.4.8.9 Guide-Rail Axes <\/td>\n<\/tr>\n
355<\/td>\nFig. 8.4.10.1.1 Earthquake Elevator Equipment Requirements Diagrammatic Representation <\/td>\n<\/tr>\n
356<\/td>\nTable 8.4.10.1.1 Visual Indication Matrix <\/td>\n<\/tr>\n
357<\/td>\nFig. 8.4.10.1.3 Earthquake Emergency Operation Diagrammatic Representation <\/td>\n<\/tr>\n
360<\/td>\nTable 8.4.11.13 Pipe Support Spacing <\/td>\n<\/tr>\n
364<\/td>\nTable 8.4.12.2.2 Maximum Allowable Deflection <\/td>\n<\/tr>\n
365<\/td>\nSECTION 8.5 ESCALATOR AND MOVING WALK SEISMIC REQUIREMENTS <\/td>\n<\/tr>\n
367<\/td>\nFig. 8.5.1 Balustrade Handrail Force <\/td>\n<\/tr>\n
368<\/td>\nSECTION 8.6 MAINTENANCE, REPAIR, REPLACEMENT, AND TESTING
Table 8.5.5 Component-Based Allowable Design Stresses <\/td>\n<\/tr>\n
380<\/td>\nTable 8.6.4.20.4 Brake Test Loads <\/td>\n<\/tr>\n
388<\/td>\nFig. 8.6.8.15.19(e) <\/td>\n<\/tr>\n
392<\/td>\nSECTION 8.7 ALTERATIONS <\/td>\n<\/tr>\n
411<\/td>\nSECTION 8.8 WELDING <\/td>\n<\/tr>\n
412<\/td>\nSECTION 8.9 CODE DATA PLATE
SECTION 8.10 ACCEPTANCE INSPECTIONS AND TESTS <\/td>\n<\/tr>\n
429<\/td>\nSECTION 8.11 PERIODIC INSPECTIONS AND WITNESSING OF TESTS <\/td>\n<\/tr>\n
436<\/td>\nSECTION 8.12 FLOOD RESISTANCES <\/td>\n<\/tr>\n
437<\/td>\nPart 9 Reference Codes, Standards, and Specifications <\/td>\n<\/tr>\n
448<\/td>\nNONMANDATORY APPENDICES
NONMANDATORY APPENDIX A CONTROL SYSTEM <\/td>\n<\/tr>\n
449<\/td>\nFig. A-1 <\/td>\n<\/tr>\n
450<\/td>\nFig. B-1 Unlocking Zone
NONMANDATORY APPENDIX B UNLOCKING ZONE <\/td>\n<\/tr>\n
451<\/td>\nFig. C-1 Parallelepiped Volume Orientations
NONMANDATORY APPENDIX C LOCATION OF TOP EMERGENCY EXIT <\/td>\n<\/tr>\n
452<\/td>\nN0NMANDATORY APPENDIX D RATED LOAD AND CAPACITY PLATES FOR PASSENGER ELEVATORS <\/td>\n<\/tr>\n
453<\/td>\nNONMANDATORY APPENDIX E ELEVATOR REQUIREMENTS FOR PERSONS WITH PHYSICAL DISABILITIES IN JURISDICTIONS ENFORCING NBCC
INTRODUCTION
E-1 Scope
E-2 Definitions
E-3 Leveling
E-4 Door Operation
E-5 Door Size
E-6 Door Protective and Reopening Device
E-6.1
E-6.2
E-7 Door Timing for Hall and Car Calls
E-7.1
E-7.2
E-7.3
E-8 Inside Dimensions of Elevator Cars
E-8.1 <\/td>\n<\/tr>\n
454<\/td>\nTable E-1 Minimum Dimensions of Elevator Cars
E-8.2
E-9 Car Controls
E-9.1 Features.
E-9.2 Height.
E-9.3 Buttons
E-9.3.1 Button Dimensions.
E-9.3.2 Button Arrangement.
E-9.3.2.1
E-9.3.3 Button Characteristics
E-9.3.3.1
E-9.3.3.2
E-9.3.4 Control Button.
E-9.3.5 Visible Indicators.
E-9.3.6 Elevator Car Call Sequential Step Scanning. <\/td>\n<\/tr>\n
455<\/td>\nE-9.4 Telephone-Style Keypads.
E-10 Car Position Indicators
E-10.1 General.
E-10.2 Visible Indicators.
E-10.2.1 Floor Arrival.
E-10.3 Audible Indicators
E-10.3.1
E-10.3.2
E-11 Emergency Communications
E-11.1 General.
E-11.2 Instructions.
E-12 Floor Surfaces
E-13 Handrails
E-14 Illumination Levels
E-15 Hall Buttons
E-15.1
E-15.2
E-15.3
E-15.4
E-15.5
E-15.6 Keypads.
E-16 Hall or In\u00c3Car Signals
E-16.1 General.
E-16.2 Audible Signals. <\/td>\n<\/tr>\n
456<\/td>\nE-16.3 Visible Signals
E-16.3.1 Height.
E-16.3.2 Size.
E-16.3.3 Visibility.
E-17 Floor\/Car Designations
E-18 Destination\u00c3Oriented Elevators
E-18.1 General.
E-18.2 Call Buttons.
E-18.3 Hall Signals
E-18.3.1 General.
E-18.3.2 Visible Signals
E-18.3.2.1 Height.
E-18.3.2.2 Size.
E-18.3.2.3 Visibility.
E-18.4 Car Controls.
E-18.5 Car Position Indicators
E-18.5.1 General.
E-18.5.2 Visible Indicators.
E-18.5.3 Audible Indicators. <\/td>\n<\/tr>\n
457<\/td>\nE-18.6 Elevator Car Identification.
E-18.7 Destination-Oriented Elevators.
E-19 Limited\u00c3Use\/Limited\u00c3Application Elevators
E-19.1 Elevator Door Requirements.
E-19.1.1 Sliding Doors.
E-19.1.2 Swinging Doors.
E-19.1.2.1 Power Operation.
E-19.1.2.2 Duration.
E-19.1.3 Door Location and Width.
E-19.1.3.1 Cars With Single Door or Doors on Opposite Ends.
E-19.1.3.2 Cars With Doors on Adjacent Sides
E-19.1.3.2.1
E-19.1.3.2.2
E-19.2 Elevator Car Requirements.
E-19.2.1 Inside Dimensions.
E-19.3 Elevator Car Controls,
E-20 Signs
E-20.1
E-20.2 Visual Characters
E-20.2.1 General
E-20.2.1.1
E-20.2.1.2
E-20.2.2 Case.
E-20.2.3 Style.
E-20.2.4 Character Height.
E-20.2.5 Character Width.
E-20.2.6 Stroke Width. <\/td>\n<\/tr>\n
458<\/td>\nE-20.2.7 Character Spacing.
E-20.2.8 Line Spacing.
E-20.2.9 Finish and Contrast.
E-20.3 Raised Characters
E-20.3.1 General.
E-20.3.2 Depth.
E-20.3.3 Case.
E-20.3.4 Style.
E-20.3.5 Character Height
E-20.3.5.1
E-20.3.5.2
E-20.3.6 Character Width.
E-20.3.7 Stroke Width.
E-20.3.7.1 Maximum.
E-20.3.7.2 Minimum.
E-20.3.8 Character Spacing.
E-20.3.9 Line Spacing.
E-20.3.10 Location.
E-20.3.11 Finish and Contrast
E-20.3.11.1
E-20.3.11.2
E-20.4 Braille
E-20.4.1 General.
E-20.4.2 Uppercase Letters.
E-20.4.3 Dimensions. <\/td>\n<\/tr>\n
459<\/td>\nFig. E-20.4 Braille Measurements
Table E-20.4 Measurement Range for Standard Sign Braille
E-20.4.4 Position.
E-20.5 Pictograms
E-20.5.1 General.
E-20.5.2 Pictogram Field.
E-20.5.3 Finish and Contrast.
E-20.6 Symbols of Accessibility
E-20.6.1 General. <\/td>\n<\/tr>\n
460<\/td>\nFig. E-20.6.3 International Symbol of Accessibility
E-20.6.2 Finish and Contrast.
E-20.6.3 International Symbol of Accessibility.
E-20.7 Variable Message Signs
E-20.7.1 General.
E-20.7.2 Protective Covering.
E-20.7.3 Rate of Change. <\/td>\n<\/tr>\n
461<\/td>\nNONMANDATORY APPENDIX F ASCENDING CAR OVERSPEED AND UNINTENDED CAR MOVEMENT PROTECTION <\/td>\n<\/tr>\n
462<\/td>\nTable F-1 Traction Elevator Brake Type, Function, and Performance <\/td>\n<\/tr>\n
463<\/td>\nFig. F-1 Ascending Car Overspeed Protection (2.19.1) <\/td>\n<\/tr>\n
464<\/td>\nFig. F-2 Unintended Car Movement Protection (2.19.2) <\/td>\n<\/tr>\n
465<\/td>\nFig. G-1 Top-of-Car Clearance Requirements
Fig. G-2 Additional Top-of-Car Clearance Requirements
NONMANDATORY APPENDIX G TOP-OF-CAR CLEARANCE <\/td>\n<\/tr>\n
466<\/td>\nFig. G-3 Top-of-Car Marking Requirements <\/td>\n<\/tr>\n
467<\/td>\nFig. G-4 Additional Top-of-Car Marking Requirements <\/td>\n<\/tr>\n
468<\/td>\nFig. G-5 Additional Top-of-Car Clearance Requirements <\/td>\n<\/tr>\n
469<\/td>\nFig. G-6 Additional Top-of-Car Clearance <\/td>\n<\/tr>\n
470<\/td>\nFig. H-1
NONMANDATORY APPENDIX H PRIVATE RESIDENCE ELEVATOR GUARDING 5.3.1.6.2 <\/td>\n<\/tr>\n
471<\/td>\nFig. I-1 Relationship of Escalator Parts
Fig. I-2 Handrail
NONMANDATORY APPENDIX I ESCALATOR AND MOVING WALK DIAGRAMS <\/td>\n<\/tr>\n
472<\/td>\nFig. I-3 Escalator Nomenclature <\/td>\n<\/tr>\n
473<\/td>\nFig. I-4 Skirt or Dynamic Skirt Panel: Step Nose
Fig. I-5 Ceiling or Soffit Guard <\/td>\n<\/tr>\n
474<\/td>\nFig. I-7 Escalator Step Tread
Fig. I-8 Cleated Riser <\/td>\n<\/tr>\n
475<\/td>\nFig. I-9 Moving Walk Geometry <\/td>\n<\/tr>\n
476<\/td>\nFig. I-10 Moving Walk Treadway Slots
Fig. I-11 Stopping Distances Corresponding to a Deceleration Rate of 0.91 m\/s2 <\/td>\n<\/tr>\n
477<\/td>\nFig. I-12 Clearance Between Escalator Steps <\/td>\n<\/tr>\n
478<\/td>\nFig. J-1
NONMANDATORY APPENDIX J RELATIONSHIP OF PIT LADDER TO HOISTWAY DOOR UNLOCKING MEANS <\/td>\n<\/tr>\n
479<\/td>\nFig. K-1
NONMANDATORY APPENDIX K BEVELING AND CLEARANCE REQUIREMENTS 7.4.7.4 <\/td>\n<\/tr>\n
480<\/td>\nNONMANDATORY APPENDIX L INDEX OF ALTERATION REQUIREMENTS FOR ELECTRIC ELEVATORS, HYDRAULIC ELEVATORS, ESCALATORS, AND MOVING WALKS <\/td>\n<\/tr>\n
485<\/td>\nFig. M-1
NONMANDATORY APPENDIX M INERTIA APPLICATION FOR TYPE A SAFETY DEVICE LOCATION OF TEST WEIGHT 8.10.2.2.2ii2 <\/td>\n<\/tr>\n
486<\/td>\nNONMANDATORY APPENDIX N RECOMMENDED INSPECTION AND TEST INTERVALS IN “MONTHS” <\/td>\n<\/tr>\n
487<\/td>\nTable N-1 Recommended Inspection and Test Intervals in \u201cMonths\u201d <\/td>\n<\/tr>\n
488<\/td>\nTable N-2 Guidelines on Use of Monitoring to Provide Inspection Data
INTRODUCTION TO MONITORING TABLE N\u00c32INTRODUCTION TO MONITORING TABLE N\u00c32INTRODUCTION TO MONITORING TABLE N\u00c32
INTRODUCTION TO MONITORING TABLE N\u00c32INTRODUCTION TO MONITORING TABLE N\u00c32INTRODUCTION TO MONITORING TABLE N\u00c32 <\/td>\n<\/tr>\n
494<\/td>\nTable P-1 Plunger Gripper Stopping Distances
NONMANDATORY APPENDIX P PLUNGER GRIPPER STOPPING DISTANCES <\/td>\n<\/tr>\n
495<\/td>\nTable Q-1
NONMANDATORY APPENDIX Q EXPLANATORY FIGURES FOR THE DEFINITIONS OF ELEVATOR MACHINERY SPACE, MACHINE ROOM, CONTROL SPACE, CONTROL ROOM, REMOTE MACHINE ROOM, OR REMOTE CONTROL ROOM <\/td>\n<\/tr>\n
496<\/td>\nFig. Q-1
Fig. Q-2
Fig. Q-3
Fig. Q-4 <\/td>\n<\/tr>\n
497<\/td>\nFig. Q-5
Fig. Q-6 <\/td>\n<\/tr>\n
498<\/td>\nNONMANDATORY APPENDIX R INSPECTION OPERATION AND HOISTWAY ACCESS SWITCH OPERATION HIERARCHY <\/td>\n<\/tr>\n
499<\/td>\nTable R-1 Inspection Operation and Hoistway Access Switch Operation Hierarchy <\/td>\n<\/tr>\n
500<\/td>\nNONMANDATORY APPENDIX S VERTICALLY SLIDING DOORS — ILLUSTRATIONS OF DETECTION ZONES 2.13.3.4 <\/td>\n<\/tr>\n
501<\/td>\nFig. S-1 <\/td>\n<\/tr>\n
502<\/td>\nFig. S-2 <\/td>\n<\/tr>\n
503<\/td>\nFig. S-3 <\/td>\n<\/tr>\n
504<\/td>\nFig. S-4 <\/td>\n<\/tr>\n
505<\/td>\nFig. S-5 <\/td>\n<\/tr>\n
506<\/td>\nFig. S-6 <\/td>\n<\/tr>\n
507<\/td>\nFig. S-7 <\/td>\n<\/tr>\n
508<\/td>\nFig. S-8 <\/td>\n<\/tr>\n
509<\/td>\nFig. S-9 <\/td>\n<\/tr>\n
510<\/td>\nFig. S-10 <\/td>\n<\/tr>\n
511<\/td>\nFig. S-11 <\/td>\n<\/tr>\n
512<\/td>\nFig. S-12 <\/td>\n<\/tr>\n
513<\/td>\nNONMANDATORY APPENDIX T <\/td>\n<\/tr>\n
514<\/td>\nTable U-1 Design Requirements \u2014 Traction Elevator Suspension System
NONMANDATORY APPENDIX U DESIGN REQUIREMENTS — TRACTION ELEVATOR SUSPENSION SYSTEM <\/td>\n<\/tr>\n
515<\/td>\nNONMANDATORY APPENDIX V BUILDING FEATURES FOR OCCUPANT EVACUATION OPERATION
V-1 Human Factors Considerations
V-1.1 Occupant Evacuation Operation. <\/td>\n<\/tr>\n
517<\/td>\nNONMANDATORY APPENDIX W <\/td>\n<\/tr>\n
518<\/td>\nTable X-1 Acceptance Test for Electric Elevators Acceptance Test: Electric Elevators
NONMANDATORY APPENDIX X ACCEPTANCE TESTS <\/td>\n<\/tr>\n
519<\/td>\nTable X-2 Acceptance Test for Hydraulic Elevators Acceptance Test: Hydraulic Elevators <\/td>\n<\/tr>\n
520<\/td>\nTable X-3 Acceptance Test for Escalators Acceptance Test: Escalators <\/td>\n<\/tr>\n
521<\/td>\nTable X-4 Acceptance Test for Moving Walks Acceptance Test: Moving Walks <\/td>\n<\/tr>\n
522<\/td>\nNONMANDATORY APPENDIX Y MAINTENANCE CONTROL PROGRAM RECORDS <\/td>\n<\/tr>\n
523<\/td>\nTable Y-1 Maintenance Control Program Records <\/td>\n<\/tr>\n
525<\/td>\nTable Z-1 Mass and Closing Time of Horizontally Sliding Elevator Doors
NONMANDATORY APPENDIX Z MASS AND CLOSING TIME OF HORIZONTALLY SLIDING ELEVATOR DOORS <\/td>\n<\/tr>\n
526<\/td>\nINDEX <\/td>\n<\/tr>\n
553<\/td>\nINTERPRETATIONS NO. 33
INTRODUCTION
APPLICABILITY OF INTERPRETATIONS
FORM AND ARRANGEMENT <\/td>\n<\/tr>\n
555<\/td>\nInquiry: 11-2010
Inquiry: 11-2153
Inquiry: 11-2155 <\/td>\n<\/tr>\n
556<\/td>\nInquiry: 11-2156 <\/td>\n<\/tr>\n
557<\/td>\nInquiry: 11-2229 <\/td>\n<\/tr>\n
558<\/td>\nInquiry: 11-2229 Reconsideration <\/td>\n<\/tr>\n
559<\/td>\nInquiry: 12-990 <\/td>\n<\/tr>\n
560<\/td>\nInquiry: 12-990 Reconsideration <\/td>\n<\/tr>\n
561<\/td>\nInquiry: 12-991
Inquiry: 12-1012 <\/td>\n<\/tr>\n
562<\/td>\nInquiry: 12-1552
Inquiry: 12-1618 <\/td>\n<\/tr>\n
563<\/td>\nInquiry: 12-1620
Inquiry: 12-1745
Inquiry: 12-1746 <\/td>\n<\/tr>\n
564<\/td>\nInquiry: 12-1747
Inquiry: 12-1748
Inquiry: 12-1749 <\/td>\n<\/tr>\n
565<\/td>\nInquiry: 12-1751
Inquiry: 12-1752
Inquiry: 12-2274 <\/td>\n<\/tr>\n
566<\/td>\nInquiry: 13-5 <\/td>\n<\/tr>\n
567<\/td>\nInquiry: 13-273 <\/td>\n<\/tr>\n
568<\/td>\nInquiry: 13-319
Inquiry: 13-343 <\/td>\n<\/tr>\n
569<\/td>\nInquiry: 13-445 <\/td>\n<\/tr>\n
571<\/td>\nInquiry: 13-496
Inquiry: 13-702
Inquiry: 13-719 <\/td>\n<\/tr>\n
572<\/td>\nInquiry: 13-742
Inquiry: 13-787
Inquiry: 13-934 <\/td>\n<\/tr>\n
573<\/td>\nInquiry: 13-1022 <\/td>\n<\/tr>\n
574<\/td>\nInquiry: 13-1050
Inquiry: 13-1460
Inquiry: 13-1462 <\/td>\n<\/tr>\n
575<\/td>\nInquiry: 13-1463
Inquiry: 13-1471
Inquiry: 13-1496 <\/td>\n<\/tr>\n
576<\/td>\nInquiry: 13-1509
Inquiry: 13-1543
Inquiry: 13-1544 <\/td>\n<\/tr>\n
577<\/td>\nInquiry: 13-1753
Inquiry: 13-1790
Inquiry: 13-2001 <\/td>\n<\/tr>\n
578<\/td>\nInquiry: 13-2177
Inquiry: 13-2197
Inquiry: 14-61 <\/td>\n<\/tr>\n
579<\/td>\nInquiry: 14-62
Inquiry: 14-85
Inquiry: 14-95 <\/td>\n<\/tr>\n
580<\/td>\nInquiry: 14-96
Inquiry: 14-227 <\/td>\n<\/tr>\n
581<\/td>\nInquiry: 14-324
Inquiry: 14-411
Inquiry: 14-503 <\/td>\n<\/tr>\n
582<\/td>\nInquiry: 14-665
Inquiry: 14-702 <\/td>\n<\/tr>\n
583<\/td>\nInquiry: 14-971
Inquiry: 14-999
Inquiry: 14-1000 <\/td>\n<\/tr>\n
584<\/td>\nInquiry: 14-1023
Inquiry: 14-1025 <\/td>\n<\/tr>\n
585<\/td>\nInquiry: 14-1026
Inquiry: 14-1104 <\/td>\n<\/tr>\n
586<\/td>\nInquiry: 14-1426
Inquiry: 14-1503 <\/td>\n<\/tr>\n
587<\/td>\nInquiry: 14-1637
Inquiry: 14-1834
Inquiry: 14-1883 <\/td>\n<\/tr>\n
588<\/td>\nInquiry: 14-1885
Inquiry: 15-39
Inquiry: 15-136 <\/td>\n<\/tr>\n
589<\/td>\nInquiry: 15-142
Inquiry: 15-319 <\/td>\n<\/tr>\n
590<\/td>\nInquiry: 15-476
Inquiry: 15-501 <\/td>\n<\/tr>\n
591<\/td>\nInquiry: 15-614 <\/td>\n<\/tr>\n
592<\/td>\nInquiry: 15-716
Inquiry: 15-883 <\/td>\n<\/tr>\n
593<\/td>\nInquiry: 15-886
Inquiry: 15-1139
Inquiry: 15-1446 <\/td>\n<\/tr>\n
594<\/td>\nInquiry: 15-1447
Inquiry: 15-1671
Inquiry: 15-1697
Inquiry: 15-1755 <\/td>\n<\/tr>\n
595<\/td>\nInquiry: 15-2003
Inquiry: 15-2004 <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

ASME A17.1 Safety Code for Elevators and Escalators<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ASME<\/b><\/a><\/td>\n2016<\/td>\n598<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":161762,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2643],"product_tag":[],"class_list":{"0":"post-161757","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-asme","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/161757","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/161762"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=161757"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=161757"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=161757"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}