{"id":191101,"date":"2024-10-19T12:04:30","date_gmt":"2024-10-19T12:04:30","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ca-firecode-2016-5\/"},"modified":"2024-10-25T04:32:46","modified_gmt":"2024-10-25T04:32:46","slug":"ca-firecode-2016-5","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ca\/ca-firecode-2016-5\/","title":{"rendered":"CA FireCode 2016"},"content":{"rendered":"
The California Fire Code (CFC) contains regulations consistent with nationally recognized and accepted practices for safeguarding life and property from the hazards of: Fire and explosion. Dangerous conditions arising from the storage, handling, and use of hazardous materials and devices. Hazardous conditions in the use or occupancy of buildings or premises. The CFC also contains provisions to assist emergency response personnel. These fire-safety-related building standards are referenced in other parts of Title 24. It’s a fully integrated code based on the 2015 International Fire Code\u00ae. Effective Date: January 1, 2017.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
2<\/td>\n | Cover <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | Copyright <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | SUPPLEMENT, July 1, 2018 <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | ERRATA, September 1, 2017 <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | ERRATA, January 1, 2017 <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | PREFACE ACKNOWLEDGEMENTS <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | California Agency Information Contact List <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | How to Distinguish Between Model Code Language and California Amendments <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | California Matrix Adoption Tables <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | Code Development Committee Responsibilities <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | EFFECTIVE USE OF THE INTERNATIONAL FIRE CODE <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | LEGISLATION <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | TABLE OF CONTENTS <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | CHAPTER 1 SCOPE AND ADMINISTRATION <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | DIVISION I\u2014CALIFORNIA ADMINISTRATION Section \n 1.1 General <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | 1.11 Office of the State Fire Marshal <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | DIVISION II\u2014ADMINISTRATION PART 1\u2014GENERAL PROVISIONS Section \n 101 Scope and General Requirements 102 Applicability <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | PART 2\u2014ADMINISTRATIVE PROVISIONS 103 Department of Fire Prevention 104 General Authority and Responsibilities <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | 105 Permits <\/td>\n<\/tr>\n | ||||||
64<\/td>\n | 106 Inspections 107 Maintenance <\/td>\n<\/tr>\n | ||||||
65<\/td>\n | 108 Board of Appeals 109 Violations <\/td>\n<\/tr>\n | ||||||
66<\/td>\n | 110 Unsafe Buildings 111 Stop Work Order 112 Service Utilities 113 Fees <\/td>\n<\/tr>\n | ||||||
68<\/td>\n | CHAPTER 2 DEFINITIONS <\/td>\n<\/tr>\n | ||||||
70<\/td>\n | Section \n 201 General 202 General Definitions <\/td>\n<\/tr>\n | ||||||
108<\/td>\n | Part II\u2014General Safety Provisions CHAPTER 3 GENERAL REQUIREMENTS Section \n 301 General <\/td>\n<\/tr>\n | ||||||
109<\/td>\n | 302 Definitions 303 Asphalt Kettles <\/td>\n<\/tr>\n | ||||||
110<\/td>\n | 304 Combustible Waste Material <\/td>\n<\/tr>\n | ||||||
111<\/td>\n | 305 Ignition Sources 306 Motion Picture Projection Rooms and Film <\/td>\n<\/tr>\n | ||||||
112<\/td>\n | 307 Open Burning, Recreational Fires and \n Portable Outdoor Fireplaces 308 Open Flames <\/td>\n<\/tr>\n | ||||||
114<\/td>\n | 309 Powered Industrial Trucks and Equipment <\/td>\n<\/tr>\n | ||||||
115<\/td>\n | 310 Smoking 311 Vacant Premises <\/td>\n<\/tr>\n | ||||||
116<\/td>\n | 312 Vehicle Impact Protection <\/td>\n<\/tr>\n | ||||||
117<\/td>\n | 313 Fueled Equipment 314 Indoor Displays 315 General Storage <\/td>\n<\/tr>\n | ||||||
118<\/td>\n | 316 Hazards to Fire Fighters <\/td>\n<\/tr>\n | ||||||
119<\/td>\n | 317 Rooftop Gardens and Landscaped Roofs 318 Laundry Carts 319 Road Tunnels, Bridges, and \n Other Limited Access Highways [SFM <\/td>\n<\/tr>\n | ||||||
120<\/td>\n | CHAPTER 4 EMERGENCY PLANNING \n AND PREPAREDNESS Section \n 401 General <\/td>\n<\/tr>\n | ||||||
121<\/td>\n | 402 Definitions 403 Emergency Preparedness Requirements <\/td>\n<\/tr>\n | ||||||
127<\/td>\n | 404 Fire Safety, Evacuation and Lockdown Plans <\/td>\n<\/tr>\n | ||||||
130<\/td>\n | 405 Emergency Evacuation Drills <\/td>\n<\/tr>\n | ||||||
131<\/td>\n | 406 Employee Training and Response Procedures 407 Hazard Communication <\/td>\n<\/tr>\n | ||||||
134<\/td>\n | Part III\u2014Building and Equipment Design Features CHAPTER 5 FIRE SERVICE FEATURES Section \n 501 General 502 Definitions <\/td>\n<\/tr>\n | ||||||
135<\/td>\n | 503 Fire Apparatus Access Roads <\/td>\n<\/tr>\n | ||||||
136<\/td>\n | 504 Access to Building Openings and Roofs <\/td>\n<\/tr>\n | ||||||
137<\/td>\n | 505 Premises Identification 506 Key Boxes 507 Fire Protection Water Supplies <\/td>\n<\/tr>\n | ||||||
138<\/td>\n | 508 Fire Command Center <\/td>\n<\/tr>\n | ||||||
139<\/td>\n | 509 Fire Protection and Utility Equipment \n Identification and Access <\/td>\n<\/tr>\n | ||||||
140<\/td>\n | 510 Emergency Responder Radio Coverage <\/td>\n<\/tr>\n | ||||||
142<\/td>\n | CHAPTER 6 BUILDING SERVICES \n AND SYSTEMS Section \n 601 General 602 Definitions 603 Fuel-fired Appliances <\/td>\n<\/tr>\n | ||||||
145<\/td>\n | 604 Emergency and Standby Power Systems <\/td>\n<\/tr>\n | ||||||
147<\/td>\n | 605 Electrical Equipment, Wiring and Hazards <\/td>\n<\/tr>\n | ||||||
150<\/td>\n | 606 Mechanical Refrigeration <\/td>\n<\/tr>\n | ||||||
153<\/td>\n | 607 Elevator Operation, Maintenance and \n Fire Service Keys <\/td>\n<\/tr>\n | ||||||
154<\/td>\n | 608 Stationary Storage Battery Systems <\/td>\n<\/tr>\n | ||||||
158<\/td>\n | 609 COMMERCIAL KITCHEN HOODS <\/td>\n<\/tr>\n | ||||||
159<\/td>\n | 610 COMMERCIAL KITCHEN COOKING OIL STORAGE <\/td>\n<\/tr>\n | ||||||
160<\/td>\n | 611 HYPERBARIC FACILITIES <\/td>\n<\/tr>\n | ||||||
162<\/td>\n | CHAPTER 7 FIRE AND SMOKE \n PROTECTION FEATURES Section \n 701 General 702 Definitions 703 Fire-resistance-rated Construction <\/td>\n<\/tr>\n | ||||||
163<\/td>\n | 704 Floor Openings and Shafts 705 Exterior Walls <\/td>\n<\/tr>\n | ||||||
164<\/td>\n | CHAPTER 8 INTERIOR FINISH, \n DECORATIVE MATERIALS \n AND FURNISHINGS <\/td>\n<\/tr>\n | ||||||
166<\/td>\n | Section \n 801 General 802 Definitions 803 Interior Wall and Ceiling Finish and \n Trim in Existing Buildings <\/td>\n<\/tr>\n | ||||||
169<\/td>\n | 804 Interior Wall and Ceiling Trim and \n Interior Floor Finish in New and \n Existing Buildings <\/td>\n<\/tr>\n | ||||||
170<\/td>\n | 805 Upholstered Furniture and Mattresses in \n New and Exisiting Buildings <\/td>\n<\/tr>\n | ||||||
173<\/td>\n | 806 Decorative Vegetation in New and \n Existing Buildings 807 Decorative Materials Other than Decorative \n Vegetation in New and Existing Buildings <\/td>\n<\/tr>\n | ||||||
177<\/td>\n | 808 Furnishings Other than Upholstered \n Furniture and Mattresses or Decorative \n Materials in New and Existing Buildings <\/td>\n<\/tr>\n | ||||||
184<\/td>\n | CHAPTER 9 FIRE PROTECTION SYSTEMS Section \n 901 General <\/td>\n<\/tr>\n | ||||||
188<\/td>\n | 902 Definitions <\/td>\n<\/tr>\n | ||||||
189<\/td>\n | 903 Automatic Sprinkler Systems <\/td>\n<\/tr>\n | ||||||
198<\/td>\n | 904 Alternative Automatic Fire-extinguishing \n Systems <\/td>\n<\/tr>\n | ||||||
202<\/td>\n | 905 Standpipe Systems <\/td>\n<\/tr>\n | ||||||
204<\/td>\n | 906 Portable Fire Extinguishers <\/td>\n<\/tr>\n | ||||||
212<\/td>\n | 907 Fire Alarm and Detection Systems <\/td>\n<\/tr>\n | ||||||
230<\/td>\n | 908 Emergency Alarm Systems <\/td>\n<\/tr>\n | ||||||
231<\/td>\n | 909 Smoke Control Systems <\/td>\n<\/tr>\n | ||||||
238<\/td>\n | 910 Smoke and Heat Removal <\/td>\n<\/tr>\n | ||||||
240<\/td>\n | 911 Explosion Control <\/td>\n<\/tr>\n | ||||||
241<\/td>\n | 912 Fire Department Connections <\/td>\n<\/tr>\n | ||||||
242<\/td>\n | 913 Fire Pumps 914 Fire Protection Based on Special Detailed \n Requirements of Use and Occupancy <\/td>\n<\/tr>\n | ||||||
246<\/td>\n | 915 Carbon Monoxide Detection <\/td>\n<\/tr>\n | ||||||
248<\/td>\n | 916 Gas Detection Systems <\/td>\n<\/tr>\n | ||||||
250<\/td>\n | CHAPTER 10 MEANS OF EGRESS <\/td>\n<\/tr>\n | ||||||
254<\/td>\n | Section \n 1001 Administration 1002 Definitions <\/td>\n<\/tr>\n | ||||||
255<\/td>\n | 1003 General Means of Egress <\/td>\n<\/tr>\n | ||||||
256<\/td>\n | 1004 Occupant Load <\/td>\n<\/tr>\n | ||||||
258<\/td>\n | 1005 Means of Egress Sizing <\/td>\n<\/tr>\n | ||||||
259<\/td>\n | 1006 Numbers of Exits and Exit Access Doorways <\/td>\n<\/tr>\n | ||||||
261<\/td>\n | 1007 Exit and Exit Access Doorway Configuration <\/td>\n<\/tr>\n | ||||||
262<\/td>\n | 1008 Means of Egress Illumination <\/td>\n<\/tr>\n | ||||||
263<\/td>\n | 1009 Accessible Means of Egress <\/td>\n<\/tr>\n | ||||||
266<\/td>\n | 1010 Doors, Gates and Turnstiles <\/td>\n<\/tr>\n | ||||||
274<\/td>\n | 1011 Stairways <\/td>\n<\/tr>\n | ||||||
278<\/td>\n | 1012 Ramps <\/td>\n<\/tr>\n | ||||||
279<\/td>\n | 1013 Exit Signs <\/td>\n<\/tr>\n | ||||||
281<\/td>\n | 1014 Handrails <\/td>\n<\/tr>\n | ||||||
282<\/td>\n | 1015 Guards <\/td>\n<\/tr>\n | ||||||
284<\/td>\n | 1016 Exit Access 1017 Exit Access Travel Distance <\/td>\n<\/tr>\n | ||||||
285<\/td>\n | 1018 Aisles <\/td>\n<\/tr>\n | ||||||
286<\/td>\n | 1019 Exit Access Stairways and Ramps <\/td>\n<\/tr>\n | ||||||
287<\/td>\n | 1020 Corridors <\/td>\n<\/tr>\n | ||||||
288<\/td>\n | 1021 Egress Balconies <\/td>\n<\/tr>\n | ||||||
289<\/td>\n | 1022 Exits 1023 Interior Exit Stairways and Ramps <\/td>\n<\/tr>\n | ||||||
291<\/td>\n | 1024 Exit Passageways <\/td>\n<\/tr>\n | ||||||
292<\/td>\n | 1025 Luminous Egress Path Markings <\/td>\n<\/tr>\n | ||||||
293<\/td>\n | 1026 Horizontal Exits <\/td>\n<\/tr>\n | ||||||
294<\/td>\n | 1027 Exterior Exit Stairways and Ramps <\/td>\n<\/tr>\n | ||||||
295<\/td>\n | 1028 Exit Discharge <\/td>\n<\/tr>\n | ||||||
296<\/td>\n | 1029 Assembly <\/td>\n<\/tr>\n | ||||||
303<\/td>\n | 1030 Emergency Escape and Rescue <\/td>\n<\/tr>\n | ||||||
304<\/td>\n | 1031 Maintenance of the Means of Egress <\/td>\n<\/tr>\n | ||||||
306<\/td>\n | CHAPTER 11 CONSTRUCTION \n REQUIREMENTS FOR \n EXISTING BUILDINGS Section \n 1101 General 1102 Definitions <\/td>\n<\/tr>\n | ||||||
307<\/td>\n | 1103 Fire Safety Requirements for \n Existing Buildings <\/td>\n<\/tr>\n | ||||||
316<\/td>\n | 1104 Means of Egress for Existing Buildings <\/td>\n<\/tr>\n | ||||||
321<\/td>\n | 1105 Construction Requirements for \n Existing Group I-2 <\/td>\n<\/tr>\n | ||||||
325<\/td>\n | 1106 Requirements for Outdoor Operations 1107 Group A Public Address System 1113 Existing Group R-1 and \n Group R-2 Occupancies [SFM <\/td>\n<\/tr>\n | ||||||
328<\/td>\n | 1114 Existing High-rise Buildings [SFM <\/td>\n<\/tr>\n | ||||||
330<\/td>\n | 1115 Existing Group I Occupancies [SFM <\/td>\n<\/tr>\n | ||||||
331<\/td>\n | 1116 Existing Group L Occupancies [SFM <\/td>\n<\/tr>\n | ||||||
334<\/td>\n | CHAPTERS 12 through 19 RESERVED <\/td>\n<\/tr>\n | ||||||
336<\/td>\n | Part IV\u2014Special Occupancies and Operations CHAPTER 20 AVIATION FACILITIES Section \n 2001 General 2002 Definitions 2003 General Precautions <\/td>\n<\/tr>\n | ||||||
337<\/td>\n | 2004 Aircraft Maintenance 2005 Portable Fire Extinguishers <\/td>\n<\/tr>\n | ||||||
338<\/td>\n | 2006 Aircraft Fueling <\/td>\n<\/tr>\n | ||||||
342<\/td>\n | 2007 Helistops and Heliports <\/td>\n<\/tr>\n | ||||||
344<\/td>\n | CHAPTER 21 DRY CLEANING Section \n 2101 General 2102 Definitions 2103 Classifications <\/td>\n<\/tr>\n | ||||||
345<\/td>\n | 2104 General Requirements 2105 Operating Requirements <\/td>\n<\/tr>\n | ||||||
346<\/td>\n | 2106 Spotting and Pretreating 2107 Dry Cleaning Systems <\/td>\n<\/tr>\n | ||||||
347<\/td>\n | 2108 Fire Protection <\/td>\n<\/tr>\n | ||||||
348<\/td>\n | CHAPTER 22 COMBUSTIBLE DUSTPRODUCING \n OPERATIONS Section \n 2201 General 2202 Definition 2203 Precautions 2204 Explosion Protection <\/td>\n<\/tr>\n | ||||||
350<\/td>\n | CHAPTER 23 MOTOR FUEL-DISPENSING \n FACILITIES AND REPAIR \n GARAGES Section \n 2301 General 2302 Definitions 2303 Location of Dispensing Devices <\/td>\n<\/tr>\n | ||||||
351<\/td>\n | 2304 Dispensing Operations <\/td>\n<\/tr>\n | ||||||
352<\/td>\n | 2305 Operational Requirements <\/td>\n<\/tr>\n | ||||||
353<\/td>\n | 2306 Flammable and Combustible Liquid Motor \n Fuel-dispensing Facilities <\/td>\n<\/tr>\n | ||||||
357<\/td>\n | 2307 Liquefied Petroleum Gas Motor \n Fuel-dispensing Facilities <\/td>\n<\/tr>\n | ||||||
358<\/td>\n | 2308 Compressed Natural Gas Motor \n Fuel-dispensing Facilities <\/td>\n<\/tr>\n | ||||||
360<\/td>\n | 2309 Hydrogen Motor Fuel-dispensing \n and Generation Facilities <\/td>\n<\/tr>\n | ||||||
362<\/td>\n | 2310 Marine Motor Fuel-dispensing Facilities <\/td>\n<\/tr>\n | ||||||
364<\/td>\n | 2311 Repair Garages <\/td>\n<\/tr>\n | ||||||
366<\/td>\n | CHAPTER 24 FLAMMABLE FINISHES Section \n 2401 General 2402 Definitions 2403 Protection of Operations <\/td>\n<\/tr>\n | ||||||
368<\/td>\n | 2404 Spray Finishing <\/td>\n<\/tr>\n | ||||||
372<\/td>\n | 2405 Dipping Operations <\/td>\n<\/tr>\n | ||||||
373<\/td>\n | 2406 Powder Coating <\/td>\n<\/tr>\n | ||||||
374<\/td>\n | 2407 Electrostatic Apparatus <\/td>\n<\/tr>\n | ||||||
375<\/td>\n | 2408 Organic Peroxides and \n Dual-component Coatings <\/td>\n<\/tr>\n | ||||||
376<\/td>\n | 2409 Indoor Manufacturing of \n Reinforced Plastics 2410 Floor Surfacing and Finishing Operations <\/td>\n<\/tr>\n | ||||||
378<\/td>\n | CHAPTER 25 FRUIT AND CROP RIPENING Section \n 2501 General 2502 Definitions 2503 Ethylene Gas 2504 Sources of Ignition <\/td>\n<\/tr>\n | ||||||
379<\/td>\n | 2505 Combustible Waste 2506 Ethylene Generators 2507 Warning Signs <\/td>\n<\/tr>\n | ||||||
380<\/td>\n | CHAPTER 26 FUMIGATION AND \n INSECTICIDAL FOGGING Section \n 2601 General 2602 Definitions 2603 Fire Safety Requirements <\/td>\n<\/tr>\n | ||||||
382<\/td>\n | CHAPTER 27 SEMICONDUCTOR \n FABRICATION FACILITIES Section \n 2701 General 2702 Definitions 2703 General Safety Provisions <\/td>\n<\/tr>\n | ||||||
386<\/td>\n | 2704 Storage <\/td>\n<\/tr>\n | ||||||
388<\/td>\n | 2705 Use and Handling <\/td>\n<\/tr>\n | ||||||
392<\/td>\n | CHAPTER 28 LUMBER YARDS AND \n AGRO-INDUSTRIAL, \n SOLID BIOMASS AND \n WOODWORKING FACILITIES Section \n 2801 General 2802 Definitions 2803 General Requirements <\/td>\n<\/tr>\n | ||||||
393<\/td>\n | 2804 Fire Protection 2805 Plywood, Veneer and Composite \n Board Mills 2806 Log Storage Areas 2807 Storage of Wood Chips and Hogged Material \n Associated with Timber and Lumber \n Production Facilities <\/td>\n<\/tr>\n | ||||||
394<\/td>\n | 2808 Storage and Processing of Wood Chips, \n Hogged Material, Fines, Compost, \n Solid Biomass Feedstock and Raw Product \n Associated with Yard Waste, \n Agro-industrial and Recycling Facilities 2809 Exterior Storage of Finished \n Lumber and Solid Biofuel Products <\/td>\n<\/tr>\n | ||||||
396<\/td>\n | CHAPTER 29 MANUFACTURE OF \n ORGANIC COATINGS Section \n 2901 General 2902 Definition 2903 General Precautions <\/td>\n<\/tr>\n | ||||||
397<\/td>\n | 2904 Electrical Equipment and Protection 2905 Process Structures 2906 Process Mills and Kettles <\/td>\n<\/tr>\n | ||||||
398<\/td>\n | 2907 Process Piping 2908 Raw Materials in Process Areas 2909 Raw Materials and Finished Products <\/td>\n<\/tr>\n | ||||||
400<\/td>\n | CHAPTER 30 INDUSTRIAL OVENS Section \n 3001 General 3002 Definitions 3003 Location 3004 Fuel Piping <\/td>\n<\/tr>\n | ||||||
401<\/td>\n | 3005 Interlocks 3006 Fire Protection 3007 Operation and Maintenance <\/td>\n<\/tr>\n | ||||||
402<\/td>\n | CHAPTER 31 TENTS AND OTHER \n MEMBRANE STRUCTURES <\/td>\n<\/tr>\n | ||||||
404<\/td>\n | Section \n 3101 General 3102 Definitions 3103 Temporary Tents and Membrane \n Structures <\/td>\n<\/tr>\n | ||||||
407<\/td>\n | 3104 Temporary and Permanent Tents \n and Membrane Structures <\/td>\n<\/tr>\n | ||||||
411<\/td>\n | 3105 Temporary Stage Canopies <\/td>\n<\/tr>\n | ||||||
414<\/td>\n | CHAPTER 32 HIGH-PILED \n COMBUSTIBLE STORAGE Section \n 3201 General <\/td>\n<\/tr>\n | ||||||
415<\/td>\n | 3202 Definitions 3203 Commodity Classification <\/td>\n<\/tr>\n | ||||||
418<\/td>\n | 3204 Designation of High-piled Storage Areas 3205 Housekeeping and Maintenance 3206 General Fire Protection and \n Life Safety Features <\/td>\n<\/tr>\n | ||||||
421<\/td>\n | 3207 Solid-piled and Shelf Storage 3208 Rack Storage <\/td>\n<\/tr>\n | ||||||
422<\/td>\n | 3209 Automated Storage 3210 Specialty Storage <\/td>\n<\/tr>\n | ||||||
424<\/td>\n | CHAPTER 33 FIRE SAFETY DURING \n CONSTRUCTION AND \n DEMOLITION Section \n 3301 General 3302 Definitions 3303 Temporary Heating Equipment 3304 Precautions against Fire <\/td>\n<\/tr>\n | ||||||
425<\/td>\n | 3305 Flammable and Combustible Liquids 3306 Flammable Gases 3307 Explosive Materials 3308 Owner\u2019s Responsibility for Fire Protection <\/td>\n<\/tr>\n | ||||||
426<\/td>\n | 3309 Fire Reporting 3310 Access for Fire Fighting 3311 Means of Egress 3312 Water Supply for Fire Protection 3313 Standpipes 3314 Automatic Sprinkler System <\/td>\n<\/tr>\n | ||||||
427<\/td>\n | 3315 Portable Fire Extinguishers 3316 Motorized Construction Equipment 3317 Safeguarding Roofing Operations <\/td>\n<\/tr>\n | ||||||
428<\/td>\n | CHAPTER 34 TIRE REBUILDING \n AND TIRE STORAGE Section \n 3401 General 3402 Definitions 3403 Tire Rebuilding <\/td>\n<\/tr>\n | ||||||
429<\/td>\n | 3404 Precautions against Fire 3405 Outdoor Storage <\/td>\n<\/tr>\n | ||||||
430<\/td>\n | 3406 Fire Department Access 3407 Fencing 3408 Fire Protection 3409 Indoor Storage Arrangement <\/td>\n<\/tr>\n | ||||||
432<\/td>\n | CHAPTER 35 WELDING AND \n OTHER HOT WORK Section \n 3501 General 3502 Definitions 3503 General Requirements <\/td>\n<\/tr>\n | ||||||
433<\/td>\n | 3504 Fire Safety Requirements <\/td>\n<\/tr>\n | ||||||
434<\/td>\n | 3505 Gas Welding and Cutting 3506 Electric Arc Hot Work 3507 Calcium Carbide Systems <\/td>\n<\/tr>\n | ||||||
435<\/td>\n | 3508 Acetylene Generators 3509 Piping Manifolds and Hose Systems for \n Fuel Gases and Oxygen 3510 Hot Work on Flammable and \n Combustible Liquid Storage Tanks <\/td>\n<\/tr>\n | ||||||
436<\/td>\n | CHAPTER 36 MARINAS Section \n 3601 Scope 3602 Definitions 3603 General Precautions 3604 Fire Protection Equipment <\/td>\n<\/tr>\n | ||||||
437<\/td>\n | 3605 Marine Motor Fuel-dispensing Facilities <\/td>\n<\/tr>\n | ||||||
438<\/td>\n | CHAPTER 37 COMBUSTIBLE FIBERS Section \n 3701 General 3702 Definitions 3703 General Precautions <\/td>\n<\/tr>\n | ||||||
439<\/td>\n | 3704 Loose Fiber Storage 3705 Baled Storage <\/td>\n<\/tr>\n | ||||||
440<\/td>\n | CHAPTER 38 PLANT PROCESSING AND EXTRACTION FACILITIES 3801 GENERAL 3802 DEFINITIONS 3803 PROCESSING AND EXTRACTION <\/td>\n<\/tr>\n | ||||||
441<\/td>\n | 3804 SYSTEMS AND EQUIPMENT 3805 SAFETY SYSTEMS <\/td>\n<\/tr>\n | ||||||
444<\/td>\n | CHAPTERS 39 through 47 RESERVED <\/td>\n<\/tr>\n | ||||||
446<\/td>\n | CHAPTER 48 MOTION PICTURE AND \n TELEVISION PRODUCTION \n STUDIO SOUND STAGES, \n APPROVED PRODUCTION \n FACILITIES AND \n PRODUCTION LOCATIONS Section \n 4801 General 4802 Occupancy Classification 4803 Required Permits <\/td>\n<\/tr>\n | ||||||
447<\/td>\n | 4804 General Requirements 4805 Fire-extinguishing Systems 4806 Fire Detection Equipment 4807 Fire Safety Officers 4808 Electrical Requirements <\/td>\n<\/tr>\n | ||||||
448<\/td>\n | 4809 Mechanical Equipment 4810 Design Requirements 4811 Production Locations <\/td>\n<\/tr>\n | ||||||
450<\/td>\n | CHAPTER 49 REQUIREMENTS FOR \n WILDLAND-URBAN \n INTERFACE FIRE AREAS Section \n 4901 General 4902 Definitions <\/td>\n<\/tr>\n | ||||||
451<\/td>\n | 4903 Reserved 4904 Fire Hazard Severity Zones 4905 Wildfire Protection Building Construction 4906 Hazardous Vegetation and Fuel Management 4907 Defensible Space <\/td>\n<\/tr>\n | ||||||
452<\/td>\n | Part V\u2014Hazardous Materials CHAPTER 50 HAZARDOUS MATERIALS\u2014 \n GENERAL PROVISIONS Section \n 5001 General <\/td>\n<\/tr>\n | ||||||
455<\/td>\n | 5002 Definitions 5003 General Requirements <\/td>\n<\/tr>\n | ||||||
470<\/td>\n | 5004 Storage <\/td>\n<\/tr>\n | ||||||
473<\/td>\n | 5005 Use, Dispensing and Handling <\/td>\n<\/tr>\n | ||||||
478<\/td>\n | CHAPTER 51 AEROSOLS Section \n 5101 General 5102 Definitions 5103 Classification of Aerosol Products 5104 Inside Storage of Aerosol Products <\/td>\n<\/tr>\n | ||||||
481<\/td>\n | 5105 Outside Storage 5106 Retail Display <\/td>\n<\/tr>\n | ||||||
483<\/td>\n | 5107 Manufacturing Facilities <\/td>\n<\/tr>\n | ||||||
484<\/td>\n | CHAPTER 52 RESERVED <\/td>\n<\/tr>\n | ||||||
486<\/td>\n | CHAPTER 53 COMPRESSED GASES Section \n 5301 General <\/td>\n<\/tr>\n | ||||||
487<\/td>\n | 5302 Definitions 5303 General Requirements <\/td>\n<\/tr>\n | ||||||
490<\/td>\n | 5304 Storage of Compressed Gases 5305 Use and Handling of Compressed Gases <\/td>\n<\/tr>\n | ||||||
491<\/td>\n | 5306 Medical Gas Systems <\/td>\n<\/tr>\n | ||||||
492<\/td>\n | 5307 Compressed Gases Not Otherwise Regulated <\/td>\n<\/tr>\n | ||||||
494<\/td>\n | CHAPTER 54 CORROSIVE MATERIALS Section \n 5401 General 5402 Definition 5403 General Requirements 5404 Storage <\/td>\n<\/tr>\n | ||||||
495<\/td>\n | 5405 Use <\/td>\n<\/tr>\n | ||||||
496<\/td>\n | CHAPTER 55 CRYOGENIC FLUIDS Section \n 5501 General 5502 Definitions 5503 General Requirements <\/td>\n<\/tr>\n | ||||||
498<\/td>\n | 5504 Storage <\/td>\n<\/tr>\n | ||||||
499<\/td>\n | 5505 Use and Handling <\/td>\n<\/tr>\n | ||||||
502<\/td>\n | CHAPTER 56 EXPLOSIVES \n AND FIREWORKS <\/td>\n<\/tr>\n | ||||||
503<\/td>\n | Section \n 5601 General <\/td>\n<\/tr>\n | ||||||
507<\/td>\n | 5602 Definitions <\/td>\n<\/tr>\n | ||||||
508<\/td>\n | 5603 Record Keeping and Reporting 5604 Explosive Materials Storage and Handling <\/td>\n<\/tr>\n | ||||||
515<\/td>\n | 5605 Manufacture, Assembly and Testing of \n Explosives, Explosive Materials and \n Fireworks <\/td>\n<\/tr>\n | ||||||
519<\/td>\n | 5606 Small Arms Ammunition and Small \n Arms Ammunition Components <\/td>\n<\/tr>\n | ||||||
520<\/td>\n | 5607 Blasting <\/td>\n<\/tr>\n | ||||||
521<\/td>\n | 5608 Fireworks Display <\/td>\n<\/tr>\n | ||||||
533<\/td>\n | 5609 Temporary Storage of Consumer Fireworks 5610 Experimental Rockets\/Unlimited <\/td>\n<\/tr>\n | ||||||
534<\/td>\n | 5611 Model Rockets <\/td>\n<\/tr>\n | ||||||
535<\/td>\n | 5612 Experimental High Power Rockets and Motors <\/td>\n<\/tr>\n | ||||||
537<\/td>\n | 5613 Emergency Signaling Devices <\/td>\n<\/tr>\n | ||||||
538<\/td>\n | CHAPTER 57 FLAMMABLE AND \n COMBUSTIBLE LIQUIDS Section \n 5701 General <\/td>\n<\/tr>\n | ||||||
539<\/td>\n | 5702 Definitions 5703 General Requirements <\/td>\n<\/tr>\n | ||||||
543<\/td>\n | 5704 Storage <\/td>\n<\/tr>\n | ||||||
559<\/td>\n | 5705 Dispensing, Use, Mixing and Handling <\/td>\n<\/tr>\n | ||||||
569<\/td>\n | 5706 Special Operations <\/td>\n<\/tr>\n | ||||||
579<\/td>\n | 5707 On-demand Mobile Fueling Operations <\/td>\n<\/tr>\n | ||||||
582<\/td>\n | CHAPTER 58 FLAMMABLE GASES \n AND FLAMMABLE \n CRYOGENIC FLUIDS Section \n 5801 General 5802 Definitions 5803 General Requirements <\/td>\n<\/tr>\n | ||||||
583<\/td>\n | 5804 Storage 5805 Use 5806 Flammable Cryogenic Fluids <\/td>\n<\/tr>\n | ||||||
584<\/td>\n | 5807 Metal Hydride Storage Systems <\/td>\n<\/tr>\n | ||||||
585<\/td>\n | 5308 Hydrogen Fuel Gas Rooms <\/td>\n<\/tr>\n | ||||||
588<\/td>\n | CHAPTER 59 FLAMMABLE SOLIDS Section \n 5901 General 5902 Definitions 5903 General Requirements 5904 Storage <\/td>\n<\/tr>\n | ||||||
589<\/td>\n | 5905 Use 5906 Magnesium <\/td>\n<\/tr>\n | ||||||
592<\/td>\n | CHAPTER 60 HIGHLY TOXIC AND \n TOXIC MATERIALS Section \n 6001 General 6002 Definitions 6003 Highly Toxic and Toxic Solids and Liquids <\/td>\n<\/tr>\n | ||||||
593<\/td>\n | 6004 Highly Toxic and Toxic Compressed Gases <\/td>\n<\/tr>\n | ||||||
598<\/td>\n | 6005 Ozone Gas Generators <\/td>\n<\/tr>\n | ||||||
600<\/td>\n | CHAPTER 61 LIQUEFIED \n PETROLEUM GASES Section \n 6101 General 6102 Definitions 6103 Installation of Equipment <\/td>\n<\/tr>\n | ||||||
601<\/td>\n | 6104 Location of LP-gas Containers <\/td>\n<\/tr>\n | ||||||
602<\/td>\n | 6105 Prohibited Use of LP-gas 6106 Dispensing and Overfilling <\/td>\n<\/tr>\n | ||||||
603<\/td>\n | 6107 Safety Precautions and Devices 6108 Fire Protection 6109 Storage of Portable LP-gas Containers \n Awaiting Use or Resale <\/td>\n<\/tr>\n | ||||||
605<\/td>\n | 6110 LP-gas Containers Not in Service 6111 Parking and Garaging of \n LP-gas Tank Vehicles <\/td>\n<\/tr>\n | ||||||
606<\/td>\n | CHAPTER 62 ORGANIC PEROXIDES Section \n 6201 General 6202 Definition 6203 General Requirements <\/td>\n<\/tr>\n | ||||||
607<\/td>\n | 6204 Storage <\/td>\n<\/tr>\n | ||||||
608<\/td>\n | 6205 Use <\/td>\n<\/tr>\n | ||||||
610<\/td>\n | CHAPTER 63 OXIDIZERS, OXIDIZING \n GASES AND OXIDIZING \n CRYOGENIC FLUIDS Section \n 6301 General 6302 Definitions 6303 General Requirements <\/td>\n<\/tr>\n | ||||||
611<\/td>\n | 6304 Storage <\/td>\n<\/tr>\n | ||||||
612<\/td>\n | 6305 Use <\/td>\n<\/tr>\n | ||||||
613<\/td>\n | 6306 Liquid Oxygen in Home Health Care <\/td>\n<\/tr>\n | ||||||
616<\/td>\n | CHAPTER 64 PYROPHORIC MATERIALS Section \n 6401 General 6402 Definition 6403 General Requirements 6404 Storage <\/td>\n<\/tr>\n | ||||||
617<\/td>\n | 6405 Use <\/td>\n<\/tr>\n | ||||||
618<\/td>\n | CHAPTER 65 PYROXYLIN (CELLULOSE \n NITRATE) PLASTICS Section \n 6501 General 6502 Definitions 6503 General Requirements 6504 Storage and Handling <\/td>\n<\/tr>\n | ||||||
620<\/td>\n | CHAPTER 66 UNSTABLE \n (REACTIVE) MATERIALS Section \n 6601 General 6602 Definition 6603 General Requirements <\/td>\n<\/tr>\n | ||||||
621<\/td>\n | 6604 Storage 6605 Use <\/td>\n<\/tr>\n | ||||||
622<\/td>\n | CHAPTER 67 WATER-REACTIVE \n SOLIDS AND LIQUIDS Section \n 6701 General 6702 Definition 6703 General Requirements 6704 Storage <\/td>\n<\/tr>\n | ||||||
623<\/td>\n | 6705 Use <\/td>\n<\/tr>\n | ||||||
624<\/td>\n | CHAPTERS 68 through 79 RESERVED <\/td>\n<\/tr>\n | ||||||
628<\/td>\n | Part VI\u2014Referenced Standards <\/td>\n<\/tr>\n | ||||||
629<\/td>\n | CHAPTER 80 REFERENCED STANDARDS <\/td>\n<\/tr>\n | ||||||
650<\/td>\n | APPENDIX CHAPTER 4 SPECIAL DETAILED \n REQUIREMENTS BASED \n ON USE AND \n OCCUPANCY Section \n 435 Special Provisions for Licensed 24-hour Care \n Facilities in a Group R-2.1, R-3.1, R-4 [SFM <\/td>\n<\/tr>\n | ||||||
653<\/td>\n | 436 Group I-4 [SFM <\/td>\n<\/tr>\n | ||||||
654<\/td>\n | 437 Special Provisions for Licensed \n 24-Hour Care Facilities in \n Groups R-3.1 and R-4 452 School Facilities for Kindergarten \n through 12th Grade and Group E \n Day Care <\/td>\n<\/tr>\n | ||||||
655<\/td>\n | 455 Large Family \n Day-Care Homes [SFM <\/td>\n<\/tr>\n | ||||||
658<\/td>\n | Part VII\u2014Appendices APPENDIX A BOARD OF APPEALS Section \n A101 General <\/td>\n<\/tr>\n | ||||||
660<\/td>\n | APPENDIX B FIRE-FLOW REQUIREMENTS \n FOR BUILDINGS Section \n B101 General B102 Definitions B103 Modifications B104 Fire-flow Calculation Area B105 Fire-flow Requirements for Buildings <\/td>\n<\/tr>\n | ||||||
662<\/td>\n | B106 Referenced Standards <\/td>\n<\/tr>\n | ||||||
664<\/td>\n | APPENDIX BB FIRE-FLOW REQUIREMENTS \n FOR BUILDINGS Section \n BB101 Scope BB102 Definitions BB103 Modifications BB104 Fire Area BB105 Fire-flow Requirements for Buildings <\/td>\n<\/tr>\n | ||||||
666<\/td>\n | APPENDIX C FIRE HYDRANT LOCATIONS \n AND DISTRIBUTION Section \n C101 General C102 Number of Fire Hydrants C103 Fire Hydrant Spacing C104 Consideration of Existing Fire Hydrants C105 Referenced Standards <\/td>\n<\/tr>\n | ||||||
668<\/td>\n | APPENDIX CC FIRE HYDRANT LOCATIONS \n AND DISTRIBUTION Section \n CC101 Scope CC102 Location CC103 Number of Fire Hydrants CC104 Consideration of Existing Fire Hydrants CC105 Distribution of Fire Hydrants <\/td>\n<\/tr>\n | ||||||
670<\/td>\n | APPENDIX D FIRE APPARATUS \n ACCESS ROADS Section \n D101 General D102 Required Access D103 Minimum Specifications <\/td>\n<\/tr>\n | ||||||
671<\/td>\n | D104 Commercial and Industrial Developments <\/td>\n<\/tr>\n | ||||||
672<\/td>\n | D105 Aerial Fire Apparatus Access Roads D106 Multiple-family Residential Developments D107 One- or Two-family Residential \n Developments D108 Referenced Standards <\/td>\n<\/tr>\n | ||||||
674<\/td>\n | APPENDIX E HAZARD CATEGORIES Section \n E101 General E102 Hazard Categories <\/td>\n<\/tr>\n | ||||||
678<\/td>\n | E103 Evaluation of Hazards <\/td>\n<\/tr>\n | ||||||
679<\/td>\n | E104 Referenced Standards <\/td>\n<\/tr>\n | ||||||
680<\/td>\n | APPENDIX F HAZARD RANKING Section \n F101 General F102 Referenced Standards <\/td>\n<\/tr>\n | ||||||
682<\/td>\n | APPENDIX G CRYOGENIC FLUIDS\u2014 \n WEIGHT AND VOLUME \n EQUIVALENTS Section \n G101 General <\/td>\n<\/tr>\n | ||||||
684<\/td>\n | APPENDIX H HAZARDOUS MATERIALS \n MANAGEMENT PLANS \n AND HAZARDOUS MATERIALS \n INVENTORY STATEMENTS Section \n H1 Scope H2 Hazardous Materials \n Inventory Statements (HMIS H3 Hazardous Materials \n Management Plan (HMMP <\/td>\n<\/tr>\n | ||||||
685<\/td>\n | H4 Maintenance of Records <\/td>\n<\/tr>\n | ||||||
696<\/td>\n | APPENDIX I FIRE PROTECTION \n SYSTEMS\u2014NONCOMPLIANT \n CONDITIONS Section \n I101 Noncompliant Conditions <\/td>\n<\/tr>\n | ||||||
697<\/td>\n | I102 Referenced Standards <\/td>\n<\/tr>\n | ||||||
698<\/td>\n | APPENDIX J BUILDING INFORMATION \n SIGN Section \n J101 General <\/td>\n<\/tr>\n | ||||||
700<\/td>\n | J102 Referenced Standards <\/td>\n<\/tr>\n | ||||||
702<\/td>\n | APPENDIX K CONSTRUCTION \n REQUIREMENTS FOR \n EXISTING AMBULATORY \n CARE FACILITIES Section \n K101 General K102 Fire Safety Requirements for Existing \n Ambulatory Care Facilities <\/td>\n<\/tr>\n | ||||||
703<\/td>\n | K103 Incidental Uses in Existing \n Ambulatory Care Facilities <\/td>\n<\/tr>\n | ||||||
704<\/td>\n | K104 Means of Egress Requirements for Existing \n Ambulatory Care Facilities K105 Referenced Standards <\/td>\n<\/tr>\n | ||||||
706<\/td>\n | APPENDIX L REQUIREMENTS FOR \n FIRE FIGHTER AIR \n REPLENISHMENT SYSTEMS Section \n L101 General L102 Definitions L103 Permits L104 Design and Installation <\/td>\n<\/tr>\n | ||||||
708<\/td>\n | L105 Acceptance Tests L106 Inspection, Testing and Maintenance L107 Referenced Standards <\/td>\n<\/tr>\n | ||||||
710<\/td>\n | APPENDIX M HIGH-RISE BUILDINGS\u2014 \n RETORACTIVE AUTOMATIC \n SPRINKLER \n REQUIREMENT Section \n M101 Scope M102 Where Required M103 Compliance M104 Referenced Standards <\/td>\n<\/tr>\n | ||||||
712<\/td>\n | APPENDIX N TEMPORARY HAUNTED HOUSES, \n GHOST WALKS AND SIMILAR \n AMUSEMENT USES Section \n N101 General <\/td>\n<\/tr>\n | ||||||
713<\/td>\n | N102 Definitions N103 General Requirements <\/td>\n<\/tr>\n | ||||||
716<\/td>\n | HISTORY NOTE APPENDIX <\/td>\n<\/tr>\n | ||||||
718<\/td>\n | INDEX <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" California Fire Code, Title 24, Part 9 (W\/ ERRATA & SUPPLEMENT)<\/b><\/p>\n |