{"id":191321,"date":"2024-10-19T12:05:34","date_gmt":"2024-10-19T12:05:34","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/asme-bpvc-iii-1-nb-2019\/"},"modified":"2024-10-25T04:33:32","modified_gmt":"2024-10-25T04:33:32","slug":"asme-bpvc-iii-1-nb-2019","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/asme\/asme-bpvc-iii-1-nb-2019\/","title":{"rendered":"ASME BPVC III 1 NB 2019"},"content":{"rendered":"
This Subsection contains requirements for the material, design, fabrication, examination, testing and overpressure protection of items which are intended to conform to the requirements for Class 1 construction. The rules of Subsection NB cover the requirements for assuring the structural integrity of items. Careful application of this Section will help users to comply with applicable regulations within their jurisdictions, while achieving the operational, cost and safety benefits to be gained from the many industry best-practices detailed within these volumes.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
53<\/td>\n | NB-1132.2-1 Attachments in the Component Support Load Path That Do Not Perform a Pressure\u2011Retaining Function <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | NB-1132.2-2 Attachments That Do Not Perform a Pressure\u2011Retaining Function and Are Not in the Component Support Load Path (Nonstructural Attachments) <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | NB-1132.2-3 Attachments That Perform a Pressure\u2011Retaining Function <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | NB-1132.2-4 Attachments Within the Reactor Pressure Vessel (Core Support Structures) That Do Not Perform a Pressure\u2011Retaining Function <\/td>\n<\/tr>\n | ||||||
64<\/td>\n | NB-2332(a)-1 Required Cv Values for Piping, Pumps, and Valves <\/td>\n<\/tr>\n | ||||||
65<\/td>\n | NB-2333-1 Required Cv Values for Bolting Material <\/td>\n<\/tr>\n | ||||||
68<\/td>\n | NB-2432.1-1 Sampling of Welding Materials for Chemical Analysis <\/td>\n<\/tr>\n | ||||||
69<\/td>\n | NB-2432.2(a)-1 Chemical Analysis for Reactor Vessel Welding Material NB-2432.2(a)-2 Chemical Analysis for Welding Material for Other Than Reactor Vessel Welds <\/td>\n<\/tr>\n | ||||||
70<\/td>\n | NB-2433.1-1 Weld Metal Delta Ferrite Content <\/td>\n<\/tr>\n | ||||||
75<\/td>\n | NB-2552-1 Axial Propagation of Sound in Tube Wall <\/td>\n<\/tr>\n | ||||||
78<\/td>\n | NB-2571-1 Required Examinations <\/td>\n<\/tr>\n | ||||||
82<\/td>\n | NB-2575.2-1 Typical Pressure\u2011Retaining Parts of Pumps and Valves <\/td>\n<\/tr>\n | ||||||
93<\/td>\n | NB-3332.2-1 Chart for Determining Value of F <\/td>\n<\/tr>\n | ||||||
95<\/td>\n | NB-3338.2(a)-1 Direction of Stress Components <\/td>\n<\/tr>\n | ||||||
96<\/td>\n | NB-3338.2(a)-2 Nozzle Dimensions <\/td>\n<\/tr>\n | ||||||
97<\/td>\n | NB-3338.2(c)-1 Stress Indices for Nozzles <\/td>\n<\/tr>\n | ||||||
98<\/td>\n | NB-3339.1(b)-1 Examples of Acceptable Transition Details NB-3339.3-1 Required Minimum Reinforcing Area, Ar <\/td>\n<\/tr>\n | ||||||
99<\/td>\n | NB-3339.4-1 Limits of Reinforcing Zone NB-3339.7(c)-1 Stress Indices for Internal Pressure Loading <\/td>\n<\/tr>\n | ||||||
100<\/td>\n | NB-3351-1 Welded Joint Locations Typical of Categories A, B, C, and D <\/td>\n<\/tr>\n | ||||||
101<\/td>\n | NB-3352-1 Typical Butt Joints <\/td>\n<\/tr>\n | ||||||
103<\/td>\n | NB-3361-1 Category A and B Joints Between Sections of Unequal Thickness <\/td>\n<\/tr>\n | ||||||
104<\/td>\n | NB-3423-1 Typical Single Volute Casing <\/td>\n<\/tr>\n | ||||||
105<\/td>\n | NB-3423-2 Typical Double Volute Casing NB-3433.4-1 Minimum Tangential Inlet and Outlet Wall Thickness <\/td>\n<\/tr>\n | ||||||
106<\/td>\n | NB-3441.1-1 Type A Pump NB-3441.1-2 Type A Pump NB-3441.2-1 Type B Pump <\/td>\n<\/tr>\n | ||||||
107<\/td>\n | NB-3441.3-1 Type C Pump NB-3441.3-2 Type C Pump <\/td>\n<\/tr>\n | ||||||
108<\/td>\n | NB-3441.4(a)-1 Type D Pump NB-3441.5-1 Type E Pump NB-3441.6(a)-1 Type F Pump <\/td>\n<\/tr>\n | ||||||
114<\/td>\n | NB-3544.1(a)-1 Fillets and Corners NB-3544.1(c)-1 Ring Grooves <\/td>\n<\/tr>\n | ||||||
115<\/td>\n | NB-3544.3-1 Lugs and Protuberances <\/td>\n<\/tr>\n | ||||||
116<\/td>\n | NB-3544.7-1 Flat Wall Limitation <\/td>\n<\/tr>\n | ||||||
117<\/td>\n | NB-3545.1(a)-1 Pressure Area Method <\/td>\n<\/tr>\n | ||||||
120<\/td>\n | NB-3545.2(a)-1 Critical Sections of Valve Bodies <\/td>\n<\/tr>\n | ||||||
122<\/td>\n | NB-3545.2(c)-1 Model for Determining Secondary Stress in Valve Crotch Region <\/td>\n<\/tr>\n | ||||||
123<\/td>\n | NB-3545.2(c)-3 Thermal Stress Index Versus Thickness Continuity Run or Branch <\/td>\n<\/tr>\n | ||||||
124<\/td>\n | NB-3545.2(c)-4 Secondary Stress Index Versus Thickness Discontinuity Run or Branch <\/td>\n<\/tr>\n | ||||||
125<\/td>\n | NB-3545.2(c)-5 C4 Versus Te1\/te NB-3545.2(c)-6 Stress Index for Thermal Fatigue <\/td>\n<\/tr>\n | ||||||
129<\/td>\n | NB-3591.1-1 Typical Pressure Relief Devices <\/td>\n<\/tr>\n | ||||||
130<\/td>\n | NB-3591.1-2 Typical Pressure Relief and Safety Relief Devices <\/td>\n<\/tr>\n | ||||||
132<\/td>\n | NB-3594.3-1 Valve Nozzle <\/td>\n<\/tr>\n | ||||||
134<\/td>\n | NB-3622-1 Examples of Reversing and Nonreversing Dynamic Loads <\/td>\n<\/tr>\n | ||||||
136<\/td>\n | NB-3641.1(a)-1 Values of A <\/td>\n<\/tr>\n | ||||||
139<\/td>\n | NB-3643.3(a)-1 Branch Connection Nomenclature <\/td>\n<\/tr>\n | ||||||
140<\/td>\n | NB-3643.3(a)-2 Typical Reinforcement of Openings <\/td>\n<\/tr>\n | ||||||
141<\/td>\n | NB-3643.3(a)-3 Typical Reinforced Extruded Outlet <\/td>\n<\/tr>\n | ||||||
143<\/td>\n | NB-3644(b)-1 Miter Joint Geometry <\/td>\n<\/tr>\n | ||||||
144<\/td>\n | NB-3647.2-1 Types of Permanent Blanks <\/td>\n<\/tr>\n | ||||||
147<\/td>\n | NB-3653.2(b)-1 Decomposition of Temperature Distribution Range <\/td>\n<\/tr>\n | ||||||
154<\/td>\n | NB-3681(a)-1 Stress Indices for Use With Equations in NB-3650 <\/td>\n<\/tr>\n | ||||||
156<\/td>\n | NB-3683.1(c)-1 <\/td>\n<\/tr>\n | ||||||
157<\/td>\n | NB-3683.1(d)-1 <\/td>\n<\/tr>\n | ||||||
160<\/td>\n | NB-3683.6-1 <\/td>\n<\/tr>\n | ||||||
162<\/td>\n | NB-3684-1 Direction of Stress Components <\/td>\n<\/tr>\n | ||||||
163<\/td>\n | NB-3685.1-1 Curved Pipe or Welding End Elbows, Internal Pressure <\/td>\n<\/tr>\n | ||||||
164<\/td>\n | NB-3685.1-2 Curved Pipe or Welding End Elbows, Moment Loading (\u03bb \u2265 0.2) <\/td>\n<\/tr>\n | ||||||
165<\/td>\n | NB-3685.2-1 Elbow Nomenclature <\/td>\n<\/tr>\n | ||||||
166<\/td>\n | NB-3686.1-1 <\/td>\n<\/tr>\n | ||||||
167<\/td>\n | NB-3686.2-1 NB-3686.5-1 Branch Connections in Straight Pipe NB-3686.6-1 Reducers <\/td>\n<\/tr>\n | ||||||
172<\/td>\n | NB-4221.1-1 Maximum Difference in Cross\u2011Sectional Diameters <\/td>\n<\/tr>\n | ||||||
173<\/td>\n | NB-4221.2(a)-1 Maximum Permissible Deviation e From a True Circular Form <\/td>\n<\/tr>\n | ||||||
174<\/td>\n | NB-4221.2(a)-2 Maximum Arc Length for Determining Plus or Minus Deviation NB-4232-1 Maximum Allowable Offset in Final Welded Joints <\/td>\n<\/tr>\n | ||||||
176<\/td>\n | NB-4233(a)-1 Butt Weld Alignment and Mismatch Tolerances for Unequal I.D. and O.D. When Components Are Welded From One Side and Fairing Is Not Performed <\/td>\n<\/tr>\n | ||||||
177<\/td>\n | NB-4243-1 Acceptable Full Penetration Weld Details for Category C Joints (NB-3352.3) <\/td>\n<\/tr>\n | ||||||
178<\/td>\n | NB-4244(a)-1 Nozzles Joined by Full Penetration Butt Welds <\/td>\n<\/tr>\n | ||||||
179<\/td>\n | NB-4244(b)-1 Nozzles Joined by Full Penetration Corner Welds <\/td>\n<\/tr>\n | ||||||
180<\/td>\n | NB-4244(c)-1 Deposited Weld Metal Used as Reinforcement of Openings for Nozzles <\/td>\n<\/tr>\n | ||||||
181<\/td>\n | NB-4244(d)-1 Partial Penetration Nozzles <\/td>\n<\/tr>\n | ||||||
182<\/td>\n | NB-4244(d)-2 Partial Penetration Nozzle for Coaxial Cylinders <\/td>\n<\/tr>\n | ||||||
183<\/td>\n | NB-4244(e)-1 Oblique Connections <\/td>\n<\/tr>\n | ||||||
184<\/td>\n | NB-4246(a)-1 Typical Piping Branch Connections Joined by Full Penetration Welds <\/td>\n<\/tr>\n | ||||||
185<\/td>\n | NB-4246(b)-1 Typical Piping Branch Connections Joined by a Fillet Weld or a Partial Penetration Weld <\/td>\n<\/tr>\n | ||||||
187<\/td>\n | NB-4250-1 Welding End Transitions \u2014 Maximum Envelope <\/td>\n<\/tr>\n | ||||||
188<\/td>\n | NB-4250-2 Component to Pipe Weld NB-4250-3 Pipe to Pipe Weld <\/td>\n<\/tr>\n | ||||||
195<\/td>\n | NB-4424.2-1 Preservice Examination Marking for Piping <\/td>\n<\/tr>\n | ||||||
196<\/td>\n | NB-4427-1 Fillet and Socket Weld Details and Dimensions <\/td>\n<\/tr>\n | ||||||
198<\/td>\n | NB-4433-1 Types of Attachment Welds <\/td>\n<\/tr>\n | ||||||
199<\/td>\n | NB-4440-1 Appurtenance Weld Joint Details, NPS 2 (DN 50) and Smaller <\/td>\n<\/tr>\n | ||||||
201<\/td>\n | NB-4511-1 Brazed Connections for Appurtenances and Piping, NPS 1 (DN 25) and Smaller NB-4524-1 Maximum Design Temperatures for Brazing Filler Metal <\/td>\n<\/tr>\n | ||||||
203<\/td>\n | NB-4622.1-1 Mandatory Requirements for Postweld Heat Treatment of Welds <\/td>\n<\/tr>\n | ||||||
204<\/td>\n | NB-4622.4(c)-1 Alternative Holding Temperatures and Times <\/td>\n<\/tr>\n | ||||||
205<\/td>\n | NB-4622.7(b)-1 Exemptions to Mandatory PWHT <\/td>\n<\/tr>\n | ||||||
209<\/td>\n | NB-4622.9(d)(1)-1 Dissimilar Metal Repair Cavity Measurement <\/td>\n<\/tr>\n | ||||||
212<\/td>\n | NB-5111-1 Thickness, IQI Designations, Essential Holes, and Wire Diameters <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" ASME BPVC – III – 1 – NB -2019 BPVC Section III, Rules for Construction of Nuclear Facility Components, Division 1, Subsection NB, Class 1 Components<\/b><\/p>\n |