{"id":194919,"date":"2024-10-19T12:22:06","date_gmt":"2024-10-19T12:22:06","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-1657-2018\/"},"modified":"2024-10-25T04:53:03","modified_gmt":"2024-10-25T04:53:03","slug":"ieee-1657-2018","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-1657-2018\/","title":{"rendered":"IEEE 1657 2018"},"content":{"rendered":"

Revision Standard – Active. The areas of recommended knowledge for installers and maintainers of stationary batteries and related systems, to the extent that they affect the battery, are defined in this recommended practice. Design of the dc system and sizing of the dc battery charger(s) are beyond the scope of this document. Only lead-acid and nickel-cadmium battery technologies are covered in this recommended practice. An outline (not necessarily in training order) of the items that should be covered by training programs for stationary battery installation and maintenance personnel is provided. Certifying trained personnel and providing its own battery technician training programs will not be performed by IEEE.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nIEEE Std 1657\u2122-2018 Front cover <\/td>\n<\/tr>\n
2<\/td>\nTitle page <\/td>\n<\/tr>\n
4<\/td>\nImportant Notices and Disclaimers Concerning IEEE Standards Documents <\/td>\n<\/tr>\n
7<\/td>\nParticipants <\/td>\n<\/tr>\n
9<\/td>\nIntroduction <\/td>\n<\/tr>\n
10<\/td>\nContents <\/td>\n<\/tr>\n
12<\/td>\n1.\u2002Overview
1.1\u2002Scope
1.2\u2002Purpose
1.3\u2002How to use this document <\/td>\n<\/tr>\n
13<\/td>\n2.\u2002Normative references
3.\u2002Definitions, acronyms, and abbreviations
3.1\u2002Definitions
3.2\u2002Acronyms and abbreviations <\/td>\n<\/tr>\n
15<\/td>\n4.\u2002Skill levels
4.1\u2002General <\/td>\n<\/tr>\n
16<\/td>\n4.2\u2002Technician skill levels
4.3\u2002Instructor knowledge and skills <\/td>\n<\/tr>\n
17<\/td>\n4.4\u2002Accreditation
5.\u2002Safety
5.1\u2002Work environment
5.2\u2002Personal protective equipment (PPE) <\/td>\n<\/tr>\n
19<\/td>\n5.3\u2002Electrical shock hazards <\/td>\n<\/tr>\n
20<\/td>\n5.4\u2002Insulation <\/td>\n<\/tr>\n
21<\/td>\n5.5\u2002Ladder safety <\/td>\n<\/tr>\n
22<\/td>\n5.6\u2002Lockout\/tagout <\/td>\n<\/tr>\n
23<\/td>\n5.7\u2002Electrostatic discharge (ESD) precautions
5.8\u2002Ventilation
5.9\u2002Working clearances, egress paths, and task lighting
5.10\u2002Battery weight concerns <\/td>\n<\/tr>\n
24<\/td>\n5.11\u2002Battery fire safety concerns
5.12\u2002Safety signs
5.13\u2002First aid <\/td>\n<\/tr>\n
25<\/td>\n5.14\u2002Spill containment and cleanup
6.\u2002Basic dc theory
6.1\u2002Terminology <\/td>\n<\/tr>\n
27<\/td>\n6.2\u2002Basic electrical components <\/td>\n<\/tr>\n
29<\/td>\n6.3\u2002Basic mathematics
6.4\u2002Basics of electrical circuits <\/td>\n<\/tr>\n
30<\/td>\n6.5\u2002Basics of rectification <\/td>\n<\/tr>\n
32<\/td>\n6.6\u2002Basics of inverters
6.7\u2002Disconnects and overcurrent protection <\/td>\n<\/tr>\n
33<\/td>\n6.8\u2002Grounded and ungrounded systems <\/td>\n<\/tr>\n
35<\/td>\n7.\u2002Battery basics
7.1\u2002General
7.2\u2002Stationary battery types <\/td>\n<\/tr>\n
36<\/td>\n7.3\u2002Basic constructions <\/td>\n<\/tr>\n
37<\/td>\n7.4\u2002Failure modes and causes <\/td>\n<\/tr>\n
39<\/td>\n7.5\u2002Charge and discharge characteristics <\/td>\n<\/tr>\n
41<\/td>\n7.6\u2002Voltage and specific gravity <\/td>\n<\/tr>\n
42<\/td>\n8.\u2002Documentation
8.1\u2002Applicable codes and standards <\/td>\n<\/tr>\n
45<\/td>\n8.2\u2002Manufacturer documentation
8.3\u2002Reading electrical and mechanical drawings <\/td>\n<\/tr>\n
47<\/td>\n8.4\u2002Keeping records
8.5\u2002Job-specific documentation <\/td>\n<\/tr>\n
48<\/td>\n9.\u2002Installation and maintenance skills
9.1\u2002General skills <\/td>\n<\/tr>\n
55<\/td>\n9.2\u2002Specific installation skills <\/td>\n<\/tr>\n
63<\/td>\n9.3\u2002Specific maintenance skills <\/td>\n<\/tr>\n
68<\/td>\n10.\u2002Cable management
10.1\u2002Cable ratings <\/td>\n<\/tr>\n
69<\/td>\n10.2\u2002Ampacity and voltage drop
10.3\u2002Cable weight stress <\/td>\n<\/tr>\n
70<\/td>\n10.4\u2002Cable routing and management <\/td>\n<\/tr>\n
71<\/td>\n11.\u2002Recycling
11.1\u2002Lead-acid battery recycling
11.2\u2002Ni-Cd battery recycling <\/td>\n<\/tr>\n
72<\/td>\nAnnex\u00a0A (informative) Analog and digital meters
A.1\u2002Advantages and disadvantages of analog meters
A.2\u2002Advantages and disadvantages of digital meters <\/td>\n<\/tr>\n
73<\/td>\nAnnex\u00a0B (normative) Hands-on training and testing
B.1\u2002Hands-on training <\/td>\n<\/tr>\n
78<\/td>\nB.2\u2002Testing <\/td>\n<\/tr>\n
82<\/td>\nAnnex\u00a0C (informative) Voltage and current effects on the human body
C.1\u2002Current effects <\/td>\n<\/tr>\n
83<\/td>\nC.2\u2002Voltage levels <\/td>\n<\/tr>\n
85<\/td>\nAnnex\u00a0D (informative) Safety implications of a UPS without an isolation transformer <\/td>\n<\/tr>\n
87<\/td>\nAnnex\u00a0E (informative) Common formulas used by battery technicians
E.1\u2002General
E.2\u2002Hydrogen evolution
E.3\u2002Voltage and specific gravity relationships for lead-acid cells <\/td>\n<\/tr>\n
88<\/td>\nE.4\u2002Internal cell resistance and short-circuit currents <\/td>\n<\/tr>\n
90<\/td>\nAnnex\u00a0F (normative) Task-level summary tables
F.1\u2002General
F.2\u2002Summary of training items for laborers (Level 0) technicians
F.3\u2002Summary of training items for Level 1 technicians <\/td>\n<\/tr>\n
93<\/td>\nF.4\u2002Summary of training items for Level 2 technicians <\/td>\n<\/tr>\n
98<\/td>\nF.5\u2002Summary of training items for Level 3 technicians <\/td>\n<\/tr>\n
102<\/td>\nF.6\u2002Summary of training items classified as specialized knowledge <\/td>\n<\/tr>\n
105<\/td>\nAnnex\u00a0G (normative) DC cabling information
G.1\u2002Cable types <\/td>\n<\/tr>\n
106<\/td>\nG.2\u2002Additional cable ampacity considerations <\/td>\n<\/tr>\n
107<\/td>\nG.3\u2002Voltage-drop calculations <\/td>\n<\/tr>\n
109<\/td>\nAnnex\u00a0H (informative) Battery PPE decision flowchart <\/td>\n<\/tr>\n
110<\/td>\nAnnex\u00a0I (informative) Glossary <\/td>\n<\/tr>\n
113<\/td>\nAnnex\u00a0J (informative) Bibliography <\/td>\n<\/tr>\n
117<\/td>\nBack cover <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

IEEE Recommended Practice for Personnel Qualifications for Installation and Maintenance of Stationary Batteries<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
IEEE<\/b><\/a><\/td>\n2018<\/td>\n117<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":194923,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2644],"product_tag":[],"class_list":{"0":"post-194919","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ieee","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/194919","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/194923"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=194919"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=194919"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=194919"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}