{"id":213067,"date":"2024-10-19T13:48:17","date_gmt":"2024-10-19T13:48:17","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-130772018-tc\/"},"modified":"2024-10-25T06:41:21","modified_gmt":"2024-10-25T06:41:21","slug":"bs-en-130772018-tc","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-130772018-tc\/","title":{"rendered":"BS EN 13077:2018 – TC"},"content":{"rendered":"
This European Standard specifies the characteristics and the requirements of air gap with non-circular overflow (unrestricted) Family A, Type B for nominal flow velocity not exceeding 3 m\/s. Air gaps are devices for protection of potable water in water installations from pollution by backflow. This European Standard applies to air gaps in factory-assembled products and to constructed air gaps in situ, and defines requirements and methods to verify and ensure compliance with this European Standard during normal working use.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
25<\/td>\n | National foreword <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | European foreword <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | 4 Designation 5 Symbolization 6 Materials <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | 7 Requirements 7.1 General 7.2 Water inlet device <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | 7.3 Overflow arrangements <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | 7.4 Air gap distance A 7.4.1 Single supply 7.4.2 Multiple supplies <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | 7.4.3 Backflow\/back pressure 7.5 Verification 7.5.1 General 7.5.2 Procedure for verification by test (see 7.4.1 a) or 7.4.2) <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | 7.5.3 Procedures for verification by calculation 8 Marking (not required for products constructed on-site) 9 Technical documents <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | Annex A (informative) Relationship between h and l for air gap Family A, Type B with rectangular overflow <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | Annex B (normative) Alternative overflow arrangements <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | Annex C (normative) Vacuum Test <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Tracked Changes. Devices to prevent pollution by backflow of potable water. Air gap with non-circular overflow (unrestricted). Family A. Type B<\/b><\/p>\n |