{"id":219580,"date":"2024-10-19T14:14:52","date_gmt":"2024-10-19T14:14:52","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-15-30298562-dc\/"},"modified":"2024-10-25T07:36:05","modified_gmt":"2024-10-25T07:36:05","slug":"bsi-15-30298562-dc","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-15-30298562-dc\/","title":{"rendered":"BSI 15\/30298562 DC"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
7<\/td>\n | Foreword <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 1 Scope 1.1 General 1.2 Exclusions 2 Normative references <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 4 Requirements 4.1 General 4.1.1 Classification principle 4.1.2 Compatibility between cooperating parts 4.1.3 Dangerous substances <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 4.1.4 Operation time for locking and unlocking 4.1.5 Product information requirements <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 4.2 Category of use 4.2.1 General 4.2.2 Axial strength of MDF and fixing 4.2.3 Requirement for free play 4.2.4 Free angular movement or misalignment <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 4.2.5 Operating torque 4.2.5.1 General 4.2.5.2 Unsprung and spring assisted lever handles 4.2.5.3 Unsprung knobs 4.2.5.4 Spring loaded lever handles or knobs 4.2.6 Rotational torque strength 4.2.7 Minimum knob or lever torque transfer 4.2.7.1 Minimum lever torque transfer <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 4.2.7.2 Minimum knob torque transfer 4.2.8 Bump requirements 4.2.9 Vibration requirements 4.2.10 Electrostatic discharge requirements 4.2.11 Status indication 4.2.12 Voltage drop protection <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | Table 1 \u2014 Category of use <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 4.3 Durability requirements 4.3.1 Durability of handle and knob function Table 2 \u2014 Durability 4.4 Suitability for use in fire resistance and smoke control doors <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 4.5 Safety 4.5.1 General 4.5.2 Axial strength for safety furniture Table 3 \u2014 Safety <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 4.6 Environmental resistance 4.6.1 Corrosion resistance requirements 4.6.2 Resistance of MDF against water 4.6.3 Dry Heat 4.6.4 Cold 4.6.5 Damp heat cyclic Table 4 \u2014 Environmental resistance MDF <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 4.7 Credential related security 4.7.1 General Table 5 \u2014 Credential related security <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 4.7.2 RFID 4.7.2.1 Effective code variations <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 4.7.2.2 Encryption 4.7.2.3 Copy protection 4.7.3 PIN Code 4.7.3.1 Effective code variations 4.7.3.2 Dead time failed attempts 4.7.3.3 Protected visibility 4.7.4 Magnetic stripe 4.7.4.1 Effective code variations 4.7.4.2 Copy protection <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 4.7.5 Biometrics 4.7.5.1 FAR\u22121 divided by maximum number of authorized templates 4.7.5.2 Alive detection 4.8 Attack resistance requirements 4.8.1 General 4.8.2 Design requirements 4.8.3 Plate strength 4.8.4 Strength of fastening elements <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 4.8.5 Resistance to attack by drilling 4.8.6 Resistance to attack by chisel 4.8.7 Resistance to attack by extraction 4.8.8 Torque resistance on handle 4.8.9 Torque resistance on knob\/thumb turn 4.8.10 Resistance to attack by twisting <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | 4.8.11 Attack by hits 4.8.12 Attack by vibrations 4.8.13 Protection against the effects of cutting cables 4.8.14 Protection against the effects of wire manipulation <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 4.8.15 Resistance to electromagnetic manipulation 4.8.16 Resistance to electrostatic manipulation 4.8.17 Increased voltage 4.8.18 Magnetic field Table 6 \u2014 Attack resistance <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | 4.9 Attack resistance requirements related to EN 1906 5 Test \u2013 general and test apparatus 5.1 General 5.2 Test fixtures <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | 6 Test methods – procedures 6.1 General 6.1.1 Testing principle 6.1.1.1 Re-testing 6.1.1.2 Re-testing of 6.8.11, 6.8.12 and 6.8.18 6.1.2 Compatibility between cooperating parts 6.1.3 Dangerous substances verification <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | 6.1.4 Operation time for locking and unlocking 6.1.5 Product information 6.1.6 Operational test of the MDF 6.2 Category of use 6.2.1 General 6.2.2 Axial strength of MDF and fixing <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | Figure 1 \u2014 Test apparatus for axial strength tests 6.2.3 Requirement for free play <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | Figure 2 \u2014 Measurement of free play 6.2.4 Free angular movement or misalignment <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | Figure 3 \u2014 Check of free angular movement 6.2.5 Operating torque 6.2.5.1 Unsprung and spring assisted lever handles 6.2.5.2 Unsprung knobs <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | 6.2.5.3 Spring loaded lever handles or knobs 6.2.6 Rotational torque strength <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | Figure 4 \u2014 Rotational torque strength test 6.2.7 Minimum knob or lever transmission 6.2.8 Bump requirements <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | 6.2.9 Vibration test Table 7 \u2014 Bump and vibration 6.2.10 Electrostatic discharge requirements 6.2.11 Status indication 6.2.12 Voltage drop protection <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | 6.3 Durability tests 6.3.1 General 6.3.2 Durability of handle and knob function <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | Figure 5 \u2014 Durability of handle and knob function test 6.4 Suitability for use on fire resistance and smoke controlled doors <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | 6.5 Safety 6.5.1 Axial strength for safety furniture 6.6 Environmental resistance tests 6.6.1 Corrosion resistance tests 6.6.2 Resistance of mechatronic door furniture against water <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | 6.6.3 Dry heat test 6.6.3.1 Conditioning of MDF 6.6.4 Cold test 6.6.4.1 Conditioning of mechatronic door furniture 6.6.5 Damp heat test (cyclic) <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | 6.7 Credential related security 6.8 Attack resistance test 6.8.1 General 6.8.2 Design requirements 6.8.3 Plate strength <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | Figure 6 \u2014 Plate strength 6.8.4 Strength of fastening elements <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | Figure 7 \u2014 Strength of fastening elements 6.8.5 Resistance to attack by drilling <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | Figure 8 \u2014 Drill attack 6.8.6 Resistance to attack by chisel <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | Figure 9 \u2014 Chisel attack fixture 6.8.7 Resistance to attack by extraction <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | Figure 10 \u2014 Fixture for attack MDF by extraction 6.8.8 Torque resistance on handle Figure 11 \u2014 Fixture for torque resistance on handle 6.8.9 Torque resistance on knob\/thumb turn <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | Figure 12 \u2014 Fixture for torque resistance on knob\/thumb turn 6.8.10 Resistance to attack by twisting Figure 13 \u2014 Fixture for attack MDF by twist 6.8.11 Attack by hits test <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | 6.8.12 Attack by vibrations test 6.8.13 Protection against the effects of cutting cables 6.8.14 Protection against the effects of wire manipulation <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | 6.8.15 Resistance to electromagnetic manipulation 6.8.16 Resistance to electrostatic manipulation 6.8.17 Increased voltage <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | 6.8.18 Magnetic field 6.9 Security \u2013 Attack resistance related to EN 1906 <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | 7 Classification system 7.1 Classification Table 8 \u2014 Classification system 7.2 Category of use: (1st character) 7.3 Durability (2nd character) 7.4 Door mass (3rd character) 7.5 Suitability for use in fire\/smoke resistant door (4th character) 7.6 Safety (5th character) <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | 7.7 Environmental resistance (6th character) 7.8 Credential related security (7th character) 7.9 Security – Attack resistance (8th character) 7.10 Security – related to EN 1906 (9th character) <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | 7.11 Example of classification Table 9 \u2014 Example of classification of MDF 8 Marking <\/td>\n<\/tr>\n | ||||||
57<\/td>\n | Annex A (normative) Tool sets for attack resistance tests Table A.1 \u2014 Tool set <\/td>\n<\/tr>\n | ||||||
60<\/td>\n | Annex B (informative) Table of test procedures Table B.1 \u2014 Test procedures mechatronic door furniture <\/td>\n<\/tr>\n | ||||||
62<\/td>\n | Annex C (informative) Installation instructions <\/td>\n<\/tr>\n | ||||||
63<\/td>\n | Annex D (informative) Calculation of effective code variations for ICC <\/td>\n<\/tr>\n | ||||||
66<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" BS EN 16867. Building hardware. Mechatronic door furniture. Requirements and test methods<\/b><\/p>\n |