{"id":229056,"date":"2024-10-19T14:53:56","date_gmt":"2024-10-19T14:53:56","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-62827-22017\/"},"modified":"2024-10-25T09:01:26","modified_gmt":"2024-10-25T09:01:26","slug":"bs-en-62827-22017","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-62827-22017\/","title":{"rendered":"BS EN 62827-2:2017"},"content":{"rendered":"
IEC 62827-2:2017(E), IEC 62827 defines a wireless power management protocol for wireless power transfer to multiple devices in a wireless power management system. Various functions of wireless power management systems are justified. The wireless power management frames and messages that work between the management block of a power source and the management block or the coupler block of a device, or the coupler block of a power source, are defined as well to execute various functions. Also, the procedures for each functionality are described based on its frames and messages.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
2<\/td>\n | National foreword <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | CONTENTS <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | INTRODUCTION <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 1 Scope 2 Normative references 3 Terms, definitions and abbreviated terms 3.1 Definitions <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 3.2 Abbreviated terms 4 Overview <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | Figures Figure 1 \u2013 Usage examples of WPMS services <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 5 Functionalities 5.1 General 5.2 Compatibility 5.2.1 General Figure 2 \u2013 WPMS structure <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 5.2.2 Indirect control 5.2.3 Direct control 5.3 Initialization 5.3.1 General 5.3.2 Frequency band scan 5.3.3 Initiation power transfer 5.4 Association 5.4.1 General 5.4.2 Communication connection 5.4.3 WPT eligibility check <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 5.5 General charging management 5.5.1 General 5.5.2 Simultaneous WPT 5.5.3 Sequential WPT 5.5.4 Foaming WPT 5.5.5 Compound WPT 5.6 Abnormal status management 5.6.1 General <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 5.6.2 Source status detection 5.6.3 Device status detection 5.7 Inter\u2013device WPT management <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 5.8 Termination 6 Protocols 6.1 General 6.2 ID structure 6.2.1 Unique coupler ID Figure 3 \u2013 Function of inter\u2013device WPT management Figure 4 \u2013 UCID structure <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 6.2.2 Group ID 6.2.3 Wireless Power management system ID 6.2.4 Device ID 6.3 Frame format 6.3.1 General Tables Table 1 \u2013 Group ID Table 2 \u2013 ID structure <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 6.3.2 Frame header 6.3.3 Frame body Figure 5 \u2013 Frame format <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 6.4 Frame type 6.4.1 General 6.4.2 Data frame 6.4.3 Acknowledgement frame Figure 6 \u2013 Data frame format Figure 7 \u2013 Acknowledgement frame format Table 3 \u2013 Frame type value <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 6.5 Payload format 6.5.1 General 6.5.2 Data frame Figure 8 \u2013 Payload format of data frame <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | 6.6 Data block 6.6.1 General 6.6.2 Request block Table 4 \u2013 Data codes <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | Figure 9 \u2013 Block format of device status request Figure 10 \u2013 Block format of WPT request Figure 11 \u2013 Block format of coil control request Figure 12 \u2013 Block format of Group ID set\u2013up request <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 6.6.3 Response block Figure 13 \u2013 Block format of inter\u2013device WPT request Figure 14 \u2013 Block format of connection response Figure 15 \u2013 Block format of device status response Figure 16 \u2013 Block format of WPT response <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | 6.6.4 Notification block Figure 17 \u2013 Block format of coil control response Figure 18 \u2013 Block format of coil control response Figure 19 \u2013 Block format of inter\u2013device WPT response Figure 20 \u2013 Block format of COM ID notification <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | Figure 21 \u2013 Block format of WPT ID notification Figure 22 \u2013 Block format of WPT mode notification Figure 23 \u2013 Block format of WPT schedule notification Figure 24 \u2013 Block format of WPT termination request Figure 25 \u2013 Block format of full charge notification <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | 7 Procedures 7.1 General 7.2 Association Figure 26 \u2013 Block format of discharge rate variation notification Figure 27 \u2013 Association <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | 7.3 Group ID Set\u2013up 7.4 General WPT management 7.4.1 Simultaneous WPT Figure 28 \u2013 Group ID set\u2013up <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | 7.4.2 Sequential WPT Figure 29 \u2013 Simultaneous WPT <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | 7.4.3 Foaming WPT Figure 30 \u2013 Sequential WPT <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | 7.4.4 Compound WPT Figure 31 \u2013 Foaming WPT <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | 7.5 Abnormal situations management 7.5.1 General 7.5.2 Source status detection Figure 32 \u2013 Compound WPT <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | 7.5.3 Device status detection Figure 33 \u2013 Source status detection <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | 7.6 Inter\u2013device WPT management Figure 34 \u2013 Full charge detection Figure 35 \u2013 Discharge rate variation detection <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | 7.7 Termination Figure 36 \u2013 Inter\u2013device WPT Figure 37 \u2013 Termination <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | Annex\u00a0A (informative)Messages A.1 General A.2 API between application and APP block A.2.1 General A.2.2 ID display A.2.3 Power status display Table A.1 \u2013 Values for ID display <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | A.2.4 WPT mode selection display Table A.2 \u2013 Values for power status display <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | A.2.5 Scheduling information display Table A.3 \u2013 Values for WPT mode selection display Table A.4 \u2013 Values for scheduling information display <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | A.2.6 Abnormal situations display A.3 Interface between MGMT and MGMT A.3.1 General Table A.5 \u2013 Values for abnormal situation display <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | A.3.2 WPMS\u2013D identification A.3.3 WPT authentication Table A.6 \u2013 Values for WPMS\u2013D identification <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | Table A.7 \u2013 Values for WPT authentication Table A.8 \u2013 Values for WPMS\u2013D power status information <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | A.3.4 Zone recognition A.3.5 WPT mode Table A.9 \u2013 Values for zone recognition <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | A.3.6 Scheduling information Table A.10 \u2013 Values for WPT mode Table A.11 \u2013 Values for scheduling information <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | A.3.7 Abnormal situations management A.3.8 WPMS\u2013D full charge notification Table A.12 \u2013 Values for abnormal situations management <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | A.3.9 WPT termination notification A.3.10 Inter\u2013device WPT Table A.13 \u2013 Values for WPMS\u2013D full charge notification Table A.14 \u2013 Values for WPT termination notification <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | A.4 Interface between MGMT block and APP block A.4.1 General A.4.2 Data request Table A.15 \u2013 Values for inter-device WPT <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | A.5 Interface between APP layer and MAC layer A.5.1 General Table A.16 \u2013 Values for data request Table A.17 \u2013 Values of MAC identification <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | A.5.2 MAC identification request A.6 Interface between MGMT block and Coupler Block A.6.1 General A.6.2 Scheduling control Table A.18 \u2013 Mac Type code Table A.19 \u2013 Values for scheduling control <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | A.6.3 Current\/voltage sensing A.6.4 Abnormal situation control Table A.20 \u2013 Values for current\/voltage sensing <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | A.6.5 WPT termination control A.6.6 Full charge Table A.21 \u2013 Values for abnormal situation control Table A.22 \u2013 Values for WPT termination control <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | A.6.7 Inter-device WPT Table A.23 \u2013 Value for full charge notification Table A.24 \u2013 Values for inter-device WPT <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Wireless power transfer. Management – Multiple device control management<\/b><\/p>\n |