{"id":241175,"date":"2024-10-19T15:47:35","date_gmt":"2024-10-19T15:47:35","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-55016-2-32006\/"},"modified":"2024-10-25T10:35:26","modified_gmt":"2024-10-25T10:35:26","slug":"bs-en-55016-2-32006","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-55016-2-32006\/","title":{"rendered":"BS EN 55016-2-3:2006"},"content":{"rendered":"

This part of CISPR 16 is designated a basic standard, which specifies the methods of measurement of radiated disturbance phenomena in the frequency range 9 kHz to 18 GHz.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
8<\/td>\n1 Scope
2 Normative references <\/td>\n<\/tr>\n
9<\/td>\n3 Terms and definitions <\/td>\n<\/tr>\n
12<\/td>\n4 Types of disturbance to be measured
4.1 Types of disturbance
4.2 Detector functions <\/td>\n<\/tr>\n
13<\/td>\n5 Connection of measuring equipment
5.1 Connection of associated equipment
5.2 Connections to RF reference ground
5.3 Connection between the EUT and the artificial mains network <\/td>\n<\/tr>\n
14<\/td>\n6 General measurement requirements and conditions
6.1 Disturbance not produced by the equipment under test
6.1.1 Compliance testing
6.2 Measurement of continuous disturbance
6.2.1 Narrowband continuous disturbance <\/td>\n<\/tr>\n
15<\/td>\n6.2.2 Broadband continuous disturbance
6.2.3 Use of spectrum analyzers and scanning receivers
6.3 Operating conditions of the EUT
6.3.1 Normal load conditions
6.3.2 The time of operation
6.3.3 Running-in time
6.3.4 Supply
6.3.5 Mode of operation <\/td>\n<\/tr>\n
16<\/td>\n6.4 Interpretation of measuring results
6.4.1 Continuous disturbance
6.4.2 Discontinuous disturbance
6.4.3 Measurement of the duration of disturbances
6.5 Measurement times and scan rates for continuous disturbance <\/td>\n<\/tr>\n
17<\/td>\n6.5.1 Minimum measurement times
6.5.2 Scan rates for scanning receivers and spectrum analyzers <\/td>\n<\/tr>\n
18<\/td>\n6.5.3 Scan times for stepping receivers <\/td>\n<\/tr>\n
19<\/td>\n6.5.4 Strategies for obtaining a spectrum overview using the peak detector <\/td>\n<\/tr>\n
22<\/td>\n7 Measurement of radiated disturbances
7.1 Introduction
7.2 Field-strength measurements in the frequency range 9\u00a0kHz to 1\u00a0GHz
7.2.1 Open area test site measurements
7.2.2 General measurement method <\/td>\n<\/tr>\n
23<\/td>\n7.2.3 Measurement distance <\/td>\n<\/tr>\n
24<\/td>\n7.2.4 Antenna height variation
7.2.5 Product specification details
7.2.5.1 Test environment <\/td>\n<\/tr>\n
25<\/td>\n7.2.5.2 Configuration of equipment under test <\/td>\n<\/tr>\n
26<\/td>\n7.2.6 Measurement instrumentation
7.2.7 Field-strength measurements on other out-door sites
7.2.8 Measurements in reverberating chambers
7.2.9 Measurement in absorber-lined shielded enclosures
7.2.9.1 Measurement in absorber-lined shielded enclosures with groundplane (semi-anechoic chambers = SAC or semi-anechoic Room = SAR)
7.2.9.2 Measurement in fully absorber-lined shielded enclosures (fully anechoic chamber = FAC or fully anechoic room = FAR)
7.2.9.2.1 Test set-up <\/td>\n<\/tr>\n
28<\/td>\n7.2.9.2.2 EUT position <\/td>\n<\/tr>\n
31<\/td>\n7.2.9.2.3 Cable layout and termination <\/td>\n<\/tr>\n
32<\/td>\n7.2.9.3 Radiated emissions (30\u00a0MHz to 1\u00a0GHz) and immunity (80\u00a0MHz to 1\u00a0GHz) test method with common test set-up in semi-anechoic chamber
7.2.9.3.1 Applicability
7.2.9.3.2 EUT perimeter definition and antenna-to-EUT separation distance
7.2.9.3.3 Uniform test volume <\/td>\n<\/tr>\n
33<\/td>\n7.2.9.3.4 Specifications for common emissions\/immunity EUT test set-up <\/td>\n<\/tr>\n
41<\/td>\n7.2.10 Measurements in TEM cells <\/td>\n<\/tr>\n
42<\/td>\n7.3 Field-strength measurements in the frequency range 1\u00a0GHz to 18\u00a0GHz
7.3.1 Quantity to measure
7.3.2 Measurement distance
7.3.3 Set-up and operating conditions of the equipment under test (EUT) <\/td>\n<\/tr>\n
43<\/td>\n7.3.4 Measurement site
7.3.5 Measurement instrumentation
7.3.6 Measurement procedure
7.3.6.1 General description of the radiated field measurement method above 1\u00a0GHz <\/td>\n<\/tr>\n
47<\/td>\n7.3.6.2 General measurement procedure
7.3.6.3 Preliminary measurement procedure <\/td>\n<\/tr>\n
48<\/td>\n7.3.6.4 Final measurement procedure <\/td>\n<\/tr>\n
49<\/td>\n7.3.6.5 Procedure for APD measurement <\/td>\n<\/tr>\n
50<\/td>\n7.3.6.5.1 Method 1 \u2013 Measurement of the level of disturbance <\/td>\n<\/tr>\n
51<\/td>\n7.3.6.5.2 Method 2 – Measurement of the probability of time
7.4 Substitution method of measurement in the frequency range of 30\u00a0MHz to 18\u00a0GHz
7.4.1 Test site <\/td>\n<\/tr>\n
52<\/td>\n7.4.2 Test antennas <\/td>\n<\/tr>\n
53<\/td>\n7.4.3 EUT configuration
7.4.4 Test procedure
7.5 Measurements of equipment in situ
7.5.1 Applicability of and preparation for in situ measurements <\/td>\n<\/tr>\n
54<\/td>\n7.5.2 Field-strength measurements in the frequency range 9\u00a0kHz to 30\u00a0MHz
7.5.2.1 Measurement method <\/td>\n<\/tr>\n
55<\/td>\n7.5.2.2 Measurement distances other than the standard distance
7.5.3 Field-strength measurements in the frequency range above 30\u00a0MHz
7.5.3.1 Measurement method
7.5.3.2 Measurement distances other than the standard distance <\/td>\n<\/tr>\n
56<\/td>\n7.5.4 In situ measurement of the effective radiated disturbance power using the substitution method
7.5.4.1 General measurement condition
7.5.4.2 Frequency range 30\u00a0MHz to 1\u00a0000\u00a0MHz
7.5.4.2.1 Measurement distance <\/td>\n<\/tr>\n
57<\/td>\n7.5.4.2.2 Measurement method <\/td>\n<\/tr>\n
59<\/td>\n7.5.4.3 Frequency range 1\u00a0GHz to 18\u00a0GHz
7.5.4.3.1 Measurement distance
7.5.4.3.2 Measurement method <\/td>\n<\/tr>\n
60<\/td>\n7.5.5 Documentation of the measurement results
7.6 Measurement in a loop antenna system
7.6.1 General measurement method <\/td>\n<\/tr>\n
61<\/td>\n7.6.2 Test environment <\/td>\n<\/tr>\n
62<\/td>\n <\/td>\n<\/tr>\n
63<\/td>\n7.6.3 Configuration of the equipment under test
8 Automated measurement of emissions
8.1 Introduction: Precautions for automating measurements <\/td>\n<\/tr>\n
64<\/td>\n8.2 Generic measurement procedure
8.3 Prescan measurements <\/td>\n<\/tr>\n
66<\/td>\n8.4 Data reduction <\/td>\n<\/tr>\n
67<\/td>\n8.5 Emission maximization and final measurement <\/td>\n<\/tr>\n
68<\/td>\n8.6 Post processing and reporting <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Specification for radio disturbance and immunity measuring apparatus and methods – Methods of measurement of disturbances and immunity – Radiated disturbance measurements<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2007<\/td>\n98<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":241181,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[625,2641],"product_tag":[],"class_list":{"0":"post-241175","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-33-100-10","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/241175","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/241181"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=241175"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=241175"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=241175"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}