{"id":241175,"date":"2024-10-19T15:47:35","date_gmt":"2024-10-19T15:47:35","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-55016-2-32006\/"},"modified":"2024-10-25T10:35:26","modified_gmt":"2024-10-25T10:35:26","slug":"bs-en-55016-2-32006","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-55016-2-32006\/","title":{"rendered":"BS EN 55016-2-3:2006"},"content":{"rendered":"
This part of CISPR 16 is designated a basic standard, which specifies the methods of measurement of radiated disturbance phenomena in the frequency range 9 kHz to 18 GHz.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
8<\/td>\n | 1 Scope 2 Normative references <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 4 Types of disturbance to be measured 4.1 Types of disturbance 4.2 Detector functions <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 5 Connection of measuring equipment 5.1 Connection of associated equipment 5.2 Connections to RF reference ground 5.3 Connection between the EUT and the artificial mains network <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 6 General measurement requirements and conditions 6.1 Disturbance not produced by the equipment under test 6.1.1 Compliance testing 6.2 Measurement of continuous disturbance 6.2.1 Narrowband continuous disturbance <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 6.2.2 Broadband continuous disturbance 6.2.3 Use of spectrum analyzers and scanning receivers 6.3 Operating conditions of the EUT 6.3.1 Normal load conditions 6.3.2 The time of operation 6.3.3 Running-in time 6.3.4 Supply 6.3.5 Mode of operation <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 6.4 Interpretation of measuring results 6.4.1 Continuous disturbance 6.4.2 Discontinuous disturbance 6.4.3 Measurement of the duration of disturbances 6.5 Measurement times and scan rates for continuous disturbance <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 6.5.1 Minimum measurement times 6.5.2 Scan rates for scanning receivers and spectrum analyzers <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 6.5.3 Scan times for stepping receivers <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 6.5.4 Strategies for obtaining a spectrum overview using the peak detector <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 7 Measurement of radiated disturbances 7.1 Introduction 7.2 Field-strength measurements in the frequency range 9\u00a0kHz to 1\u00a0GHz 7.2.1 Open area test site measurements 7.2.2 General measurement method <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 7.2.3 Measurement distance <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 7.2.4 Antenna height variation 7.2.5 Product specification details 7.2.5.1 Test environment <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 7.2.5.2 Configuration of equipment under test <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 7.2.6 Measurement instrumentation 7.2.7 Field-strength measurements on other out-door sites 7.2.8 Measurements in reverberating chambers 7.2.9 Measurement in absorber-lined shielded enclosures 7.2.9.1 Measurement in absorber-lined shielded enclosures with groundplane (semi-anechoic chambers = SAC or semi-anechoic Room = SAR) 7.2.9.2 Measurement in fully absorber-lined shielded enclosures (fully anechoic chamber = FAC or fully anechoic room = FAR) 7.2.9.2.1 Test set-up <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 7.2.9.2.2 EUT position <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | 7.2.9.2.3 Cable layout and termination <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | 7.2.9.3 Radiated emissions (30\u00a0MHz to 1\u00a0GHz) and immunity (80\u00a0MHz to 1\u00a0GHz) test method with common test set-up in semi-anechoic chamber 7.2.9.3.1 Applicability 7.2.9.3.2 EUT perimeter definition and antenna-to-EUT separation distance 7.2.9.3.3 Uniform test volume <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | 7.2.9.3.4 Specifications for common emissions\/immunity EUT test set-up <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | 7.2.10 Measurements in TEM cells <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | 7.3 Field-strength measurements in the frequency range 1\u00a0GHz to 18\u00a0GHz 7.3.1 Quantity to measure 7.3.2 Measurement distance 7.3.3 Set-up and operating conditions of the equipment under test (EUT) <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | 7.3.4 Measurement site 7.3.5 Measurement instrumentation 7.3.6 Measurement procedure 7.3.6.1 General description of the radiated field measurement method above 1\u00a0GHz <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | 7.3.6.2 General measurement procedure 7.3.6.3 Preliminary measurement procedure <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | 7.3.6.4 Final measurement procedure <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | 7.3.6.5 Procedure for APD measurement <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | 7.3.6.5.1 Method 1 \u2013 Measurement of the level of disturbance <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | 7.3.6.5.2 Method 2 – Measurement of the probability of time 7.4 Substitution method of measurement in the frequency range of 30\u00a0MHz to 18\u00a0GHz 7.4.1 Test site <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | 7.4.2 Test antennas <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | 7.4.3 EUT configuration 7.4.4 Test procedure 7.5 Measurements of equipment in situ 7.5.1 Applicability of and preparation for in situ measurements <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | 7.5.2 Field-strength measurements in the frequency range 9\u00a0kHz to 30\u00a0MHz 7.5.2.1 Measurement method <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | 7.5.2.2 Measurement distances other than the standard distance 7.5.3 Field-strength measurements in the frequency range above 30\u00a0MHz 7.5.3.1 Measurement method 7.5.3.2 Measurement distances other than the standard distance <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | 7.5.4 In situ measurement of the effective radiated disturbance power using the substitution method 7.5.4.1 General measurement condition 7.5.4.2 Frequency range 30\u00a0MHz to 1\u00a0000\u00a0MHz 7.5.4.2.1 Measurement distance <\/td>\n<\/tr>\n | ||||||
57<\/td>\n | 7.5.4.2.2 Measurement method <\/td>\n<\/tr>\n | ||||||
59<\/td>\n | 7.5.4.3 Frequency range 1\u00a0GHz to 18\u00a0GHz 7.5.4.3.1 Measurement distance 7.5.4.3.2 Measurement method <\/td>\n<\/tr>\n | ||||||
60<\/td>\n | 7.5.5 Documentation of the measurement results 7.6 Measurement in a loop antenna system 7.6.1 General measurement method <\/td>\n<\/tr>\n | ||||||
61<\/td>\n | 7.6.2 Test environment <\/td>\n<\/tr>\n | ||||||
62<\/td>\n | <\/td>\n<\/tr>\n | ||||||
63<\/td>\n | 7.6.3 Configuration of the equipment under test 8 Automated measurement of emissions 8.1 Introduction: Precautions for automating measurements <\/td>\n<\/tr>\n | ||||||
64<\/td>\n | 8.2 Generic measurement procedure 8.3 Prescan measurements <\/td>\n<\/tr>\n | ||||||
66<\/td>\n | 8.4 Data reduction <\/td>\n<\/tr>\n | ||||||
67<\/td>\n | 8.5 Emission maximization and final measurement <\/td>\n<\/tr>\n | ||||||
68<\/td>\n | 8.6 Post processing and reporting <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Specification for radio disturbance and immunity measuring apparatus and methods – Methods of measurement of disturbances and immunity – Radiated disturbance measurements<\/b><\/p>\n |