{"id":247374,"date":"2024-10-19T16:16:51","date_gmt":"2024-10-19T16:16:51","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-60793-1-442011\/"},"modified":"2024-10-25T11:23:36","modified_gmt":"2024-10-25T11:23:36","slug":"bs-en-60793-1-442011","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-60793-1-442011\/","title":{"rendered":"BS EN 60793-1-44:2011"},"content":{"rendered":"
IEC 60793-1-44:2011 establishes uniform requirements for measuring the cut-off wavelength of single-mode optical fibre, thereby assisting in the inspection of fibres and cables for commercial purposes. This standard gives the methods for measuring the cut-off wavelength of fibre and cable. This edition constitutes a technical revision. The main change with respect to the previous edition is the withdrawal of Annex D. This publication is to be read in conjunction with \/2.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
6<\/td>\n | CONTENTS \n <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | 1 Scope 2 Normative references 3 Background <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 4 Overview of methods 5 Mapping functions <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 6 Reference test method 7 Apparatus 7.1 Light source 7.2 Modulation 7.3 Launch optics 7.4 Support and positioning apparatus 7.5 Cladding mode stripper <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 7.6 Deployment mandrel Figures \n Figure 1 \u2013 Deployment configuration for cable cut-off wavelength, method A <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | Figure 2 \u2013 Deployment configuration for cable cut-off wavelength, method B Figure 3 \u2013 Default configuration to measure \nlambdac <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 7.7 Detection optics 7.8 Detector assembly and signal detection electronics 8 Sampling and specimens 8.1 Specimen length Figure 4 \u2013 Deployment configurations for fibre cut-off measurement <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 8.2 Specimen end face 9 Procedure 9.1 Positioning of specimen in apparatus 9.2 Measurement of output power Figure 5 \u2013 Cut-off wavelength using the bend-reference technique <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 10 Calculations 10.1 Bend-reference technique Figure 6 \u2013 Cut-off wavelength using the multimode-reference technique <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 10.2 Multimode-reference technique 10.3 Curve-fitting technique for improved precision (optional) <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 11 Results 11.1 Report the following information with each measurement: 11.2 The following information shall be available upon request: <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 12 Specification information <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | Annex A (normative) Requirements specific to method A \u2013 \nCable cut-off wavelength, lambdacc, using uncabled fibre <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | Annex B (normative) Requirements specific to method B \u2013 Cable cut-off wavelength, lambda \ncc, using cabled fibre <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | Annex C (normative) Requirements specific to method C \u2013 \nFibre cut-off wavelength,lambdac <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Optical fibres – Measurement methods and test procedures. Cut-off wavelength<\/b><\/p>\n |