{"id":247489,"date":"2024-10-19T16:17:24","date_gmt":"2024-10-19T16:17:24","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-61300-3-252013\/"},"modified":"2024-10-25T11:24:30","modified_gmt":"2024-10-25T11:24:30","slug":"bs-en-61300-3-252013","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-61300-3-252013\/","title":{"rendered":"BS EN 61300-3-25:2013"},"content":{"rendered":"

This part of IEC 61300 describes the procedure to determine the concentricity of the axis of the bore in a non-angled ferrule with the axis of the ferrule, or in the case of non-angled ferrules with fibre installed, to determine the concentricity of the axis of the fibre core with the axis of the ferrule.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
6<\/td>\nEnglish
CONTENTS <\/td>\n<\/tr>\n
7<\/td>\n1 Scope
2 Normative references
3 General description
3.1 General <\/td>\n<\/tr>\n
8<\/td>\n3.2 Method A: Ferrule surface reference method (reference test method)
3.3 Method B: Core centre reference method in fibre assembled ferrule
3.4 Method C: Ferrule bore reference method for bare ferrule
4 Apparatus
4.1 Method A
4.2 Method B
Figures
Figure 1 \u2013 Definition of concentricity misalignment <\/td>\n<\/tr>\n
9<\/td>\n4.3 Method C
5 Procedure
5.1 Method A
5.2 Method B
Figure 2 \u2013 Example of set-up for concentricity measurement (method A) <\/td>\n<\/tr>\n
10<\/td>\n5.3 Method C (only applicable to ferrules without fibre installed)
Figure 3 \u2013 Example of set-up for concentricity measurement (method B)
Figure 4 \u2013 Example of set-up for concentricity measurement (method C) <\/td>\n<\/tr>\n
11<\/td>\n6 Details to be specified
6.1 Method A
6.2 Method B
6.3 Method C <\/td>\n<\/tr>\n
12<\/td>\nAnnex A (informative) Method to determine the centre of the ferrule bore (bare ferrule case) using a signal processor <\/td>\n<\/tr>\n
13<\/td>\nAnnex B (informative) Method to determine the fibre core centre using a signal processor <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Fibre optic interconnecting devices and passive components. Basic test and measurement procedures – Examinations and measurements. Concentricity of the non-angled ferrules and non-angled ferrules with fibre installed<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2014<\/td>\n16<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":247494,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[650,2641],"product_tag":[],"class_list":{"0":"post-247489","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-33-180-20","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/247489","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/247494"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=247489"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=247489"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=247489"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}