{"id":252145,"date":"2024-10-19T16:38:34","date_gmt":"2024-10-19T16:38:34","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-618031999a12010\/"},"modified":"2024-10-25T11:57:14","modified_gmt":"2024-10-25T11:57:14","slug":"bs-en-618031999a12010","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-618031999a12010\/","title":{"rendered":"BS EN 61803:1999+A1:2010"},"content":{"rendered":"
Applies mainly to 12-pulse thyristor convertors and presents a set of standard procedures for determining the total losses of an HVDC converter station.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | BRITISH STANDARD <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | National foreword <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | Foreword Contents <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | 1 Scope 2 Normative references 3 Definitions and symbols 3.1 Definitions 3.1.1 auxiliary losses 3.1.2 no-load operation losses 3.1.3 load level <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | 3.1.4 operating losses 3.1.5 rated load 3.1.6 total station losses 3.2 Letter symbols <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 4 General 4.1 Introduction 4.2 Ambient conditions <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 4.3 Operating parameters 5 Determination of equipment losses 5.1 Thyristor valve losses <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 5.2 Converter transformer losses <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 5.3 AC filter losses <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 5.4 Shunt capacitor bank losses 5.5 Shunt reactor losses 5.6 DC smoothing reactor losses <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 5.7 DC filter losses <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 5.8 Auxiliaries and station service losses 5.9 Radio interference\/PLC filter losses <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 5.10 Other equipment losses <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | Figure 1 – Typical high-voltage direct current (HVDC) equipment for one pole (auxiliary equipment is not shown) <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | Figure 2 – Simplified three-phase diagram of an HVDC 12-pulse converter Figure 3 – Simplified equivalent circuit of a typical thyristor valve <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | Figure 4 – Current and voltage waveforms of a valve operating in a 12-pulse converter (commutation overshoot… <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | Figure 5 – Thyristor on-state characteristic Figure 6 – Conduction current and voltage drop <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | Figure 7 – Distribution of commutating inductance between L Figure 8 – Thyristor current during reverse recovery <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | Annex A (normative) Calculation of harmonic currents and voltages A.1 Harmonic currents in converter transformers A.2 Harmonic currents in the a.c. filters <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | A.3 Harmonic voltages on the d.c. side A.4 DC side harmonic currents in the smoothing reactor Annex B (informative) Typical station losses <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | Annex C (informative) Annex C (informative) <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | Annex ZA (normative) Normative references to international publications with their corresponding European … <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Determination of power losses in high-voltage direct current (HVDC) converter stations with line-commutated converters<\/b><\/p>\n |