{"id":254714,"date":"2024-10-19T16:49:56","date_gmt":"2024-10-19T16:49:56","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-62361-22013\/"},"modified":"2024-10-25T12:15:46","modified_gmt":"2024-10-25T12:15:46","slug":"bs-en-62361-22013","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-62361-22013\/","title":{"rendered":"BS EN 62361-2:2013"},"content":{"rendered":"
IEC 62361-2:2013 documents the quality codes used by existing IEC standards related to supervisory control and data acquisition (SCADA) in the field of power systems management. Meter reading quality coding is not considered to be in the scope of this version of the document. It determines and documents mapping between these standards. Eventual loss of quality information that might occur in mapping is documented. A cohesive and common list of quality codes with semantics is defined. The identified standards to be dealt with in this document are: IEC 60870-5, IEC 60870-6 TASE.2, IEC 61850, IEC 61970, DAIS DA, OPC DA and OPC UA.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
6<\/td>\n | English CONTENTS <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | INTRODUCTION <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 1 Scope 2 Normative references <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 3 Terms and definitions 4 Overview of applicable IEC standards Figures Figure 1 \u2013 Overview of IEC power systems information exchange standards <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 5 Quality code flow diagram from substation to control center <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | Figure 2 \u2013 Example of quality code flow diagram from substationto remote control center <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 6 List of quality codes by existing standards 6.1 Comparison of quality codes in existing standards <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | Tables Table 1 \u2013 Overview of quality codes in existing standards <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 6.2 IEC\u00a060870-5-101\/ IEC\u00a060870-5-104 quality codes 6.2.1 Data related quality 6.2.2 Timestamp and related quality <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 6.3 IEC\u00a060870-5-103 quality codes 6.4 IEC\u00a060870-6 (TASE.2) quality codes 6.4.1 Data related quality <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 6.4.2 Timestamp and related quality Table 2 \u2013 Validity attribute values Table 3 \u2013 CurrentSource attribute values Table 4 \u2013 NormalSource attribute values Table 5 \u2013 NormalValue attribute values <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 6.5 IEC\u00a061850 quality codes (from IEC\u00a061850-7-3) 6.5.1 Data related quality Figure 3 \u2013 Quality type definitions <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | Table 6 \u2013 DetailQual relation to invalid or questionable <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 6.5.2 Quality in the client server context <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | Figure 4 \u2013 Quality identifiers in a single client \u2013 server relationship Figure 5 \u2013 Quality identifiers in a multiple client \u2013 server relationship <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 6.5.3 Relation between quality identifiers <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 6.5.4 Timestamp and related quality Figure 6 \u2013 Interaction of substitution and validity <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | Table 7 \u2013 TimeStamp type definition Table 8 \u2013 TimeQuality definition excerpt from IEC\u00a061850-7-2:2010, Table 8 <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 6.6 IEC\u00a061970-301 quality codes 6.6.1 General 6.6.2 MeasurementValueQuality Attributes defined in IEC\u00a061970-301 Table 9 \u2013 TimeAccuracy excerpt from IEC\u00a061850-5:2013, Table 9 <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | 6.6.3 MeasurementValueSource naming conventions Figure 7 \u2013 MeasurementValueQuality attributes inherited from IEC\u00a061850 Table 10 \u2013 Example MeasurementValueSource naming conventions <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 6.7 OPC and OMG quality codes 6.7.1 OPC DA quality codes Table 11 \u2013 Lower 8 bits of OPC DA quality flags Table 12 \u2013 OPC standard quality BitField definition <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | Table 13 \u2013 Substatus for BAD quality Table 14 \u2013 Substatus for UNCERTAIN quality <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | 6.7.2 DAIS Data Access Quality codes Table 15 \u2013 Substatus for GOOD quality Table 16 \u2013 Limit BitField contents <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | Figure 8 \u2013 OMG DAIS quality codes Table 17 \u2013 OPCQuality members Table 18 \u2013 Quality, status and limit bit masks Table 19 \u2013 Main quality enumerations <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | Table 20 \u2013 Detailed quality flags for bad quality Table 21 \u2013 Detailed quality flags for uncertain quality Table 22 \u2013 Definition of limit flags <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | 6.7.3 Timestamp and related quality Table 23 \u2013 DAIS masks Table 24 \u2013 DAIS flags defining source Table 25 \u2013 Timestamp for DAIS quality flags <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | 6.8 OPC UA Data Access Status Codes 6.8.1 Overview 6.8.2 Operation level result codes Table 26 \u2013 Bad operation level result codes Table 27 \u2013 Uncertain operation level result codes <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | 7 Mapping of quality codes between standards 7.1 General 7.2 Mapping from IEC\u00a061850 to IEC\u00a060870-5-101\/ IEC\u00a060870-5-104 Table 28 \u2013 Good operation level result codes <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | Table 29 \u2013 Mapping from IEC\u00a061850 to IEC\u00a060870-5-101\/IEC\u00a060870-5-104 <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | 7.3 Mapping from IEC\u00a060870-5-101\/IEC\u00a060870-5-104 to IEC\u00a061970-301 Table 30 \u2013 Mapping from IEC\u00a060870-5-101\/IEC\u00a060870-5-104 to IEC\u00a061970-301 <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | 7.4 Mapping from IEC\u00a061850 to IEC\u00a061970-301 <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | Table 31 \u2013 Mapping from IEC\u00a061850 to IEC\u00a061970-301 <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | 7.5 Mapping from IEC\u00a060870-6 to IEC\u00a061970-301 Table 32 \u2013 Mapping from IEC\u00a060870-6 to IEC\u00a061970-301 <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | 7.6 Mapping from IEC\u00a061970-301 to IEC\u00a060870-6 <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | Table 33 \u2013 Mapping from IEC\u00a061970-301 to IEC\u00a060870-6 <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | 7.7 Mapping from IEC\u00a061850 to DAIS DA and OPC DA Table 34 \u2013 Mapping from IEC\u00a061850 to DAIS DA and OPC DA <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | 8 Common quality codes across the power systems information exchange standards 8.1 Common quality codes 8.2 Quality code definitions 8.2.1 Validity quality codes <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | 8.2.2 Detailed quality codes Table 35 \u2013 Validity quality codes Table 36 \u2013 Detailed good quality codes <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | Table 37 \u2013 Detailed invalid quality codes <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | Table 38 \u2013 Detailed questionable quality codes <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | 8.2.3 Additional quality codes 8.2.4 Timestamp related quality codes 8.2.5 Source quality codes Table 39 \u2013 Additional quality codes Table 40 \u2013 Timestamp quality codes <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | Table 41 \u2013 Process and substituted quality codes <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Power systems management and associated information exchange. Interoperability in the long term – End to end quality codes for supervisory control and data acquisition (SCADA)<\/b><\/p>\n |