{"id":270895,"date":"2024-10-19T18:09:24","date_gmt":"2024-10-19T18:09:24","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-14-30294501-dc\/"},"modified":"2024-10-25T14:20:53","modified_gmt":"2024-10-25T14:20:53","slug":"bsi-14-30294501-dc","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-14-30294501-dc\/","title":{"rendered":"BSI 14\/30294501 DC"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | 30294501 <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | 41_e_stf <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | Contents Page <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | Foreword <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions 3.1 General definitions <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 3.2 Main types of expansion devices 3.2.1.1 Adjustment switch without check rails (both sides moveable) 3.2.1.2 Adjustment switch without check rails (one side moveable) <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 3.2.1.3 Adjustment switch with check rails (both sides moveable) 3.2.1.4 Adjustment switch with check rails (one side moveable) <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 3.2.2.1 Expansion switch with moveable stock rails 3.2.2.2 Expansion switch with moveable switch rails <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 3.2.2.3 Expansion switch both sides moveable 4 Design 4.1 Design inputs <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 4.2 Design rules 4.2.1 General rules 4.2.1.1 Support panel 4.2.1.2 Low restraint fastenings 4.2.1.3 Slide chairs 4.2.1.4 Total longitudinal resistance 4.2.1.5 Special requirements <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 4.2.2 Wheel\/rail interaction 4.2.3 Specific rules 4.2.3.1 Adjustment switches with interruption of the running edge 4.2.3.2 Expansion switches <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 4.2.3.3 Reference points 4.3 Performance requirements 4.4 Materials 4.5 Design output 4.5.1 Detailed component plans <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 4.5.2 Assembly documents 5 Tolerances and inspection 5.1 General 5.2 Tools and instruments 5.3 Critical dimensions <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 5.4 Adjustment switch (bayonet type) <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 5.5 Expansion switch <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 5.6 Certification 5.7 Methods of examination for structural defects 6 Longitudinal resistance testing 6.1 Test method <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 6.2 Test results 7 Acceptance testing 8 Limits and extent of supply 9 Identification marks <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" BS EN 13232-8. Railway applications. Track. Switches and crossings for Vignole rails. Part 8. Expansion devices<\/b><\/p>\n |