{"id":273740,"date":"2024-10-19T18:23:37","date_gmt":"2024-10-19T18:23:37","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-12098-12017-tc\/"},"modified":"2024-10-25T14:45:15","modified_gmt":"2024-10-25T14:45:15","slug":"bs-en-12098-12017-tc","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-12098-12017-tc\/","title":{"rendered":"BS EN 12098-1:2017 – TC"},"content":{"rendered":"

This European Standard applies to electronic control equipment for heating systems with water as the heating medium and a supply water temperature up to 120 \u00b0C. This control equipment controls the distribution and\/or the generation of heat in relation to the outside temperature and time and other reference variables. This standard covers also controllers that contain an integrated optimum start or an optimum start-stop control function. Safety requirements on heating systems remain unaffected by this standard. The dynamic behaviour of the valves and actuators are not covered in this standard. A multi-distribution and\/or multi-generation system needs a coordinated solution to prevent undesired interaction and is not part of this standard. Table 1 shows the relative position of this standard within the set of EPB standards in the context of the modular structure as set out in prEN ISO 52000 1. NOTE 1 In prCEN ISO\/TR 52000 2 the same table can be found, with, for each module, the numbers of the relevant EPB standards and accompanying technical reports that are published or in preparation. NOTE 2 The modules represent EPB standards, although one EPB standard may cover more than one module and one module may be covered by more than one EPB standard, for instance a simplified and a detailed method respectively.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
52<\/td>\nNational foreword <\/td>\n<\/tr>\n
58<\/td>\n1 Scope <\/td>\n<\/tr>\n
60<\/td>\n2 Normative references
3 Terms and definitions <\/td>\n<\/tr>\n
67<\/td>\n4 Symbols, subscripts and abbreviations
4.1 Symbols
4.2 Subscripts
5 Functionality
5.1 Functional objective
5.2 Control equipment functionality <\/td>\n<\/tr>\n
68<\/td>\n6 Requirements
6.1 Data protection <\/td>\n<\/tr>\n
69<\/td>\n6.2 Characteristic heating curve <\/td>\n<\/tr>\n
70<\/td>\n6.3 Input signal \u2013 Sensors
6.4 Controller operation modes
6.4.1 General
6.4.2 Comfort operation mode
6.4.3 Economy operation mode <\/td>\n<\/tr>\n
71<\/td>\n6.4.4 Building protection operation mode
6.4.5 Automatic operation mode
6.5 Frost protection
6.6 Additional functions
6.6.1 General
6.6.2 Summer\/Winter switch function
6.6.3 Set back function
6.6.4 Optimum start function
6.6.5 Optimum stop function <\/td>\n<\/tr>\n
72<\/td>\n6.7 Switching times
6.8 Manual Operation Mode (MOM) <\/td>\n<\/tr>\n
73<\/td>\n6.9 Parameter settings
6.10 Factory settings\/Default values
6.10.1 Characteristic heating curve
6.10.2 Switching times\/Operating condition
6.11 Switching relays
6.12 Electrical requirements
6.12.1 Electrical connections
6.12.2 Supply voltage
6.12.3 Electrical safety
6.12.4 Electro-magnetic compatibility <\/td>\n<\/tr>\n
74<\/td>\n6.13 Degree of protection
6.14 Environmentally induced stress due to temperature
6.15 Materials
6.16 Use of graphical symbols
7 Test methods
7.1 Data protection
7.2 Controller operation modes
7.3 Controller characteristic heating curve <\/td>\n<\/tr>\n
79<\/td>\n7.4 Frost protection
7.5 Switching times
7.6 Manual Operation Mode
7.7 Optimum start-stop function
7.7.1 General <\/td>\n<\/tr>\n
81<\/td>\n7.7.2 Test conditions
7.7.3 Test run
7.7.4 Test results start optimization <\/td>\n<\/tr>\n
83<\/td>\n7.8 Test results stop optimization <\/td>\n<\/tr>\n
84<\/td>\n7.9 Summer\/Winter-switch
7.10 Set back
7.11 Parameter settings
7.12 Factory settings
7.13 Switching relays
7.14 Electrical test
7.15 Degrees of protection
7.16 Environmental individual stress due to temperature <\/td>\n<\/tr>\n
85<\/td>\n8 Marking
9 Documentation
9.1 Technical documents
9.2 Technical specifications
9.2.1 Controller <\/td>\n<\/tr>\n
86<\/td>\n9.2.2 Output signals
9.2.3 Input signals (Sensors)
9.3 Instruction installation
9.4 User guideline <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Tracked Changes. Energy Performance of Buildings. Controls for heating systems – Control equipment for hot water heating systems. Modules M3-5, 6, 7, 8<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2020<\/td>\n90<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":273743,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[1273,2641],"product_tag":[],"class_list":{"0":"post-273740","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-91-140-10","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/273740","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/273743"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=273740"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=273740"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=273740"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}