{"id":279318,"date":"2024-10-19T18:50:39","date_gmt":"2024-10-19T18:50:39","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-61331-32014\/"},"modified":"2024-10-25T15:24:38","modified_gmt":"2024-10-25T15:24:38","slug":"bs-en-61331-32014","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-61331-32014\/","title":{"rendered":"BS EN 61331-3:2014"},"content":{"rendered":"
IEC 61331-3:2014 applies to protective devices such as protective clothing and eyewear for the protection of persons against X radiation up to 150 kV, during radiological examinations and interventional procedures. This standard deals with general requirements on the accompanying documents, on design and on materials used and with sizing, particular design features, minimum attenuation properties of materials, marking and standardized forms of statements of compliance with this standard. It covers protective clothing mainly for the protection of the operator, such as: – protective aprons; – thyroid collars; – protective gloves; – protective mittens; and – protective eyewear. It also covers protective devices for the protection of the patient, such as: – protective gonad aprons; – scrotum shields; – ovary shields; – shadow shields; and – protective aprons for dental use. The latter group of protective devices is intended to be used during radiological examinations to minimize the effects of irradiation on the reproductive organs particularly with regard to genetic damage. This second edition cancels and replaces the first edition of IEC 61331-3, published in 1998. It constitutes a technical revision. This second edition has been adapted to apply to the present technology. It includes a requirement to use a better method for the determination of attenuation properties over a broader and more clinically relevant range of radiation qualities appropriate to the use of the devices. It also covers three additional protective devices, thyroid collars, protective eyewear and protective aprons for dental use.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
6<\/td>\n | English CONTENTS <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 1 Scope 2 Normative references <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 4 General 4.1 Accompanying documents 4.2 Language of the accompanying documents 4.3 General requirement on marking 4.4 Design 4.4.1 Protective devices for the protection of operators <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 4.4.2 Protective devices for the protection of the patient 4.5 Materials 4.5.1 Materials effecting attenuation 4.5.2 Cleaning 4.5.3 Touchable surfaces 5 Protective aprons and thyroid collars 5.1 General 5.2 Design <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 5.3 Materials 5.4 Dimensions <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 5.5 Marking 5.6 Statement of compliance Tables Table\u00a01 \u2013 Information and examples for marking protective aprons and thyroid collars <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 6 Protective gloves 6.1 General 6.2 Design 6.3 Materials 6.4 Dimensions <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 6.5 Marking Figures Figure\u00a01 \u2013 Inside dimensions of protective gloves Table\u00a02 \u2013 Standard sizes of protective gloves Table\u00a03 \u2013 Information and examples for marking protective gloves <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 6.6 Statement of compliance 7 Protective mittens 7.1 General 7.2 Design 7.3 Materials 7.4 Dimensions <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 7.5 Marking 7.6 Statement of compliance Figure\u00a02 \u2013 Inside minimum dimensions of protective mittens Table\u00a04 \u2013 Information and examples for marking protective mittens <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 8 Protective gonad aprons 8.1 General 8.2 Design 8.3 Materials 8.4 Dimensions 8.5 Marking Table\u00a05 \u2013 Standard sizes of protective gonad aprons <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 8.6 Statement of compliance 9 Scrotum shields 9.1 General 9.2 Design Table\u00a06 \u2013 Information and examples for marking protective gonad aprons <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 9.3 Materials 9.4 Dimensions 9.5 Marking 9.6 Statement of compliance 10 Ovary shields 10.1 General Table\u00a07 \u2013 Information and examples for marking scrotum shields <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 10.2 Design 10.3 Materials 10.4 Dimensions 10.5 Marking 10.6 Statement of compliance Table\u00a08 \u2013 Information and examples for marking ovary shields <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 11 Shadow shields 11.1 General 11.2 Design 11.3 Materials 11.4 Dimensions 11.5 Marking 11.6 Statement of compliance Table\u00a09 \u2013 Information and examples for marking shadow shields <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 12 Protective aprons for dental use 12.1 General 12.2 Design 12.3 Materials 12.4 Dimensions Table\u00a010 \u2013 Standard sizes of protective aprons for dental use <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 12.5 Marking 12.6 Statement of compliance 13 Protective eyewear 13.1 General 13.2 Design Table\u00a011 \u2013 Information and examples for marking protective aprons for dental use <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 13.3 Materials 13.4 Marking 13.5 Statement of compliance Table\u00a012 \u2013 Information and examples for marking protective eyewear <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | Bibliography <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | Index of defined terms used in this standard <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Protective devices against diagnostic medical X-radiation – Protective clothing, eyewear and protective patient shields<\/b><\/p>\n |