{"id":300348,"date":"2024-10-19T20:29:59","date_gmt":"2024-10-19T20:29:59","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ashrae-standard-62-1-2019-spanish\/"},"modified":"2024-10-25T17:56:10","modified_gmt":"2024-10-25T17:56:10","slug":"ashrae-standard-62-1-2019-spanish","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ashrae\/ashrae-standard-62-1-2019-spanish\/","title":{"rendered":"ASHRAE Standard 62.1 2019 Spanish"},"content":{"rendered":"
[This is a Spanish translation of ANSI\/ASHRAE Standard 62.1-2019, Ventilation for Acceptable Indoor Air Quality, completed by Jos\u00e9 Mar\u00eda Ortiz with support of Alberto Garc\u00eda and Andr\u00e9s Sep\u00falveda of the ASHRAE Spain Chapter.]First published in 1973 as Standard 62, Standard 62.1 specifies minimum ventilation rates and other measures for new and existing buildings that are intended to provide indoor air quality that is acceptable to human occupants and that minimizes adverse health effects.The revised 2019 edition of the standard includes significant changes, including:- New informative tables of ventilation rates per unit area for checking new and existing buildings ventilation calculations- Simplified version of the Ventilation Rate Procedure improving calculations for system ventilation efficiency and zone air distribution effectiveness- Modified Natural Ventilation Procedure calculation methodology- Revised scope to specifically identify occupancies previously not coveredAdditionally:- Natural ventilation now requires considering the quality of the outdoor air and interaction of the outdoor air with mechanically cooled spaces.- Humidity control requirements are now expressed as dew point and not as relative humidity.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | Est\u00e1ndar ASHRAE 62.1-2019 <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | \u00cdNDICE <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | PR\u00d3LOGO <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | 1. OBJETIVO 1.1 El objetivo de este est\u00e1ndar es especificar las tasas m\u00ednimas de ventilaci\u00f3n y otras medidas destinadas a suministrar una calidad de aire interior (CAI), que sea adecuada para la ocupaci\u00f3n humana y minimice los efectos negativos sobre la salud. 1.2 Este est\u00e1ndar est\u00e1 elaborado para el cumplimiento de la normativa en edificios nuevos, ampliaciones de edificios existentes y aquellos cambios en \u00e9stos, identificados en el contenido del est\u00e1ndar. 1.3 Este est\u00e1ndar se ha redactado para utilizarse como gu\u00eda para mejorar la calidad de aire interior (CAI) en edificios existentes. 2. ALCANCE 2.1 Este est\u00e1ndar se aplica a espacios destinados a la ocupaci\u00f3n humana dentro de edificios, excepto aquellos con viviendas con ocupaci\u00f3n residencial no transitoria. 2.2 Este est\u00e1ndar define los requisitos de proyecto, montaje, puesta en marcha y commissioning, operaci\u00f3n y mantenimiento de sistemas de ventilaci\u00f3n y de purificaci\u00f3n de aire. 2.3 Adem\u00e1s de la ventilaci\u00f3n, este est\u00e1ndar contiene los requisitos relativos a ciertos contaminantes y fuentes de contaminaci\u00f3n, incluyendo el aire exterior, los procesos de montaje, la humedad, y el crecimiento biol\u00f3gico. 2.4 Este est\u00e1ndar no prescribe requisitos espec\u00edficos de tasas de ventilaci\u00f3n para: 3. DEFINICIONES 3.1 Terminolog\u00eda (v\u00e9ase la Figura 3-1) <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 4. CALIDAD DEL AIRE EXTERIOR 4.1 Calidad del Aire Regional. El nivel de cumplimiento con los est\u00e1ndares nacionales de calidad del aire ambiental debe determinarse para el \u00e1rea geogr\u00e1fica en la que se ubica el edificio. 4.2 Calidad del Aire Local. Debe llevarse a cabo un estudio observacional de la ubicaci\u00f3n del edificio y sus alrededores m\u00e1s pr\u00f3ximos durante las horas en las que se espera que el edificio est\u00e9 normalmente ocupado, para identificar contaminantes … 4.3 Documentaci\u00f3n. La documentaci\u00f3n relativa al an\u00e1lisis de la calidad del aire exterior debe revisarse con la Propiedad del edificio o sus representantes e incluir, como m\u00ednimo, los siguientes apartados: 5. SISTEMAS Y EQUIPOS 5.1 Distribuci\u00f3n del Aire de Ventilaci\u00f3n. Los sistemas de ventilaci\u00f3n deben dise\u00f1arse de acuerdo con los requisitos de los siguientes apartados. <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 5.2 Ubicaci\u00f3n de los Conductos de Extracci\u00f3n 5.3 Controles de Sistemas de Ventilaci\u00f3n. Los sistemas de ventilaci\u00f3n mec\u00e1nica deben incluir controles de acuerdo con los siguientes puntos. 5.4 Superficies Expuestas a Corrientes de Aire. Todas las superficies expuestas a corrientes de aire en equipos y conductos de las instalaciones climatizaci\u00f3n (HVAC), deben proyectarse y montarse de acuerdo con los requisitos de los siguientes apart… 5.5 Tomas de Aire Exterior. Las tomas de aire exterior del sistema de ventilaci\u00f3n deben proyectarse de acuerdo con los siguientes puntos. <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 5.6 Captura Local de Contaminantes. La descarga de equipos de no combusti\u00f3n que captura los contaminantes generados por ellos debe canalizarse directamente al exterior. 5.7 Dispositivos de Generaci\u00f3n de Ozono. La utilizaci\u00f3n de dispositivos de generaci\u00f3n de ozono debe cumplir con las siguientes secciones. 5.8 Aire de Combusti\u00f3n. Los equipos que queman combustible, ventilados o sin ventilar, deben suministrarse con aire para la combusti\u00f3n y la retirada de los productos de la combusti\u00f3n de acuerdo con las instrucciones del fabricante. Los productos d… <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 5.9 Eliminaci\u00f3n de Part\u00edculas. Los filtros de part\u00edculas, o los purificadores de aire que tengan cualquiera de las dos condiciones siguientes, deben suministrarse aguas arriba de todas las bater\u00edas de refrigeraci\u00f3n o de otros dispositivos con su… 5.10 Punto de Roc\u00edo M\u00e1ximo del Aire Interior en Edificios Refrigerados Mec\u00e1nicamente. Los edificios o espacios equipados con o atendidos por equipos de enfriamiento mec\u00e1nico deben estar provistos de componentes de deshumidificaci\u00f3n o controles q… 5.11 Exfiltraci\u00f3n del Edificio. Los sistemas de ventilaci\u00f3n de un edificio equipado o atendido por equipos de refrigeraci\u00f3n mec\u00e1nica deben proyectarse de manera que el aire exterior total que entra al edificio sea igual o exceda la extracci\u00f3n to… <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 5.12 Bandejas de Drenaje. Las bandejas de drenaje, incluyendo sus desag\u00fces y juntas, deben dise\u00f1arse de acuerdo con este punto. 5.13 Bater\u00edas de Tubo Aleteado e Intercambiadores de Calor 5.14 Humidificadores y Sistemas de Pulverizaci\u00f3n de Agua. Los humidificadores de vapor y de evaporaci\u00f3n directa, purificadores de aire, enfriadores por evaporaci\u00f3n directa y cualquier otro sistema de pulverizaci\u00f3n de agua deben dise\u00f1arse de acue… <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 5.15 Accesos para Inspecci\u00f3n, Limpieza y Mantenimiento 5.16 Envolvente del Edificio y Superficies Interiores. La envolvente del edificio y las superficies interiores dentro de la envolvente del edificio deben proyectarse de acuerdo con los siguientes puntos: <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 5.17 Edificios con Garajes Anexos. Con el fin de limitar la entrada de los gases de escape de veh\u00edculos en espacios habitables, los edificios con aparcamientos adyacentes deben dise\u00f1arse para: 5.18 Recirculaci\u00f3n y Clasificaci\u00f3n del Aire. El aire debe clasificarse y su recirculaci\u00f3n debe limitarse de acuerdo a los siguientes puntos. <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 5.19 Requisitos para Edificios con Zonas con Humo de Tabaco Ambiental (ETS) y Zonas Libres de ETS. Los requisitos de esta secci\u00f3n deben cumplirse cuando un edificio tenga zonas ETS y zonas libres de ETS. Esos edificios deben construirse y utilizarse… <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 6. PROCEDIMIENTOS 6.1 Generalidades. Para cumplir con los requisitos de este punto debe emplearse el Procedimiento de Tasa de Ventilaci\u00f3n, el Procedimiento CAI (Calidad de Aire Interior), el Procedimiento de Ventilaci\u00f3n Natural, o una combinaci\u00f3n de los mismos. Adi… <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 6.2 Procedimiento de Tasa de Ventilaci\u00f3n. El caudal de aire exterior de entrada (V0t) de un sistema de ventilaci\u00f3n debe determinarse de acuerdo con el punto 6.1.4 y los puntos 6.2.1 a 6.2.6. <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | 6.3 Procedimiento CAI. El caudal de aire exterior en la zona de respiraci\u00f3n (Vbz) debe determinarse de acuerdo con los puntos de 6.3.1 a 6.3.5. <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | 6.4 Procedimiento de Ventilaci\u00f3n Natural. Los sistemas de ventilaci\u00f3n natural deben cumplir con los requisitos de los puntos 6.4.1 o 6.4.2. Los proyectistas deben incluir barreras de aire, aislamiento o cualquier otro medio para separar los espacio… <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | 6.5 Ventilaci\u00f3n por Extracci\u00f3n. Puede emplearse tanto la V\u00eda Prescriptiva de Cumplimiento como la V\u00eda Prestacional de Cumplimiento para cumplir con los requisitos de este punto. Debe permitirse que el aire de renovaci\u00f3n por extracci\u00f3n sea una c… 6.6 Procedimientos de Documentaci\u00f3n de Dise\u00f1o. Los criterios e hip\u00f3tesis de dise\u00f1o deben documentarse y estar disponibles para facilitar el correcto funcionamiento del sistema despu\u00e9s de la instalaci\u00f3n del mismo. Cons\u00faltense los puntos 4.3, 5…. 7. MONTAJE Y PUESTA EN MARCHA DE SISTEMAS 7.1 Fase de Montaje <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | 7.2 Puesta en Marcha del Sistema <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | 8. OPERACI\u00d3N Y MANTENIMIENTO 8.1 Generalidades 8.2 Manual O&M. Un manual O&M, ya sea en formato impreso o digital, debe elaborarse y guardarse en el edificio o en una ubicaci\u00f3n centralizada accesible durante la vida \u00fatil del equipo correspondiente o componentes del sistema de ventilaci\u00f3n. Este… 8.3 Funcionamiento del Sistema de Ventilaci\u00f3n. Los sistemas de ventilaci\u00f3n natural y mec\u00e1nica deben funcionar de manera coherente con el Manual O&M. Los sistemas deben funcionar de manera que los espacios est\u00e9n ventilados de acuerdo con la Secci… 8.4 Mantenimiento del Sistema de Ventilaci\u00f3n. Los componentes de los sistemas de ventilaci\u00f3n del edificio deben mantenerse de acuerdo al Manual O&M. <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | 9. REFERENCIAS NORMATIVAS <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | ANEXO NORMATIVO A: EFICIENCIA DE VENTILACI\u00d3N EN SISTEMAS MULTIZONA: PROCEDIMIENTO ALTERNATIVO A1. eficiencia del sistema de ventilaci\u00f3n A1.1 Fracci\u00f3n de Aire Exterior Promedio. La fracci\u00f3n de aire exterior promedio (Xs) para el sistema de ventilaci\u00f3n debe determinarse mediante la Ecuaci\u00f3n A-1: A1.2 Eficiencia de Ventilaci\u00f3n de Zona. La eficiencia de ventilaci\u00f3n de zona (Evz) debe determinarse de acuerdo con los puntos A1.2.1 o A1.2.2. <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | A1.3 Eficiencia de Ventilaci\u00f3n del Sistema. La eficiencia de ventilaci\u00f3n del sistema debe ser igual a la eficiencia de ventilaci\u00f3n m\u00e1s baja de zona, entre todas las zonas de ventilaci\u00f3n servidas por la unidad de tratamiento de aire seg\u00fan la Ecu… <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | A2. PROCESO DE DISE\u00d1O A2.1 Selecci\u00f3n de Zonas para el C\u00e1lculo. La eficiencia de ventilaci\u00f3n de zona (Evz) debe calcularse para todas las zonas de ventilaci\u00f3n. A3. S\u00cdmbolOs <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | ANEXO NORMATIVO B: SEPARACI\u00d3N ENTRE LAS SALIDAS DE EXTRACCI\u00d3N Y LAS ENTRADAS DE AIRE EXTERIOR B1. General B1.1 Aplicaci\u00f3n. Las salidas de aire de extracci\u00f3n de campanas extractoras de humos de laboratorio, deben cumplir los Est\u00e1ndares NFPA 45 y ANSI\/AIHA Z9.5. Las salidas de extracci\u00f3n que no sean de laboratorio y las tomas de aire exterior u otras a… B1.2 Tomas de Aire Exterior. La distancia m\u00ednima de separaci\u00f3n entre las salidas de aire de extracci\u00f3n\/ventilaci\u00f3n, seg\u00fan se definen en la Tabla 5-1, y las tomas de aire exterior a sistemas de ventilaci\u00f3n mec\u00e1nica o a ventanas practicables, lu… B1.3 Otras Aberturas del Edificio. La distancia m\u00ednima de separaci\u00f3n entre las salidas de aire de extracci\u00f3n\/ventilaci\u00f3n, seg\u00fan se define en la Tabla 5-1, y las aberturas practicables a los espacios habitables deber ser la mitad de la distancia … B1.4 Limitaciones Adicionales para Aire Nocivo o Peligroso. La distancia m\u00ednima de separaci\u00f3n entre conductos de extracci\u00f3n ubicados a menos de 20 m (65 ft) verticalmente por debajo de las tomas de aire exterior o de las ventanas y puertas practic… B1.5 Pozos de Equipo. Las salidas de aire de extracci\u00f3n que terminen en un pozo de equipo que tambi\u00e9n disponga de una entrada de aire exterior deben cumplir los requisitos de separaci\u00f3n de este punto y, adem\u00e1s, deben B1.6 L\u00edneas de Propiedad. La distancia m\u00ednima de separaci\u00f3n entre las salidas de aire de extracci\u00f3n\/ventilaci\u00f3n y las l\u00edneas de propiedad debe ser la mitad de la distancia (L) determinada seg\u00fan el punto B2. <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | B2. DetermiNACI\u00d3N DE LA DISTANCIA L B2.1 M\u00e9todo Sencillo. Debe utilizarse un valor de L de la Tabla B-1. B2.2 M\u00e9todo de Velocidad. El valor L debe determinarse mediante las Ecuaci\u00f3nes B-1a (I-P) o B-1b (SI): <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | B2.3 M\u00e9todo de Concentraci\u00f3n. Determina la concentraci\u00f3n aceptable para la salud (Chealth) y el olor (Codor) para cada sustancia qu\u00edmica, componente o mezcla emitida. <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | ANEXO NORMATIVO C: EFECTIVIDAD DE LA DISTRIBUCI\u00d3N DE AIRE EN LA ZONA: PROCEDIMIENTOS ALTERNATIVOS C1. EFECTIVIDAD DE DISTRIBUCI\u00d3N DE AIRE EN LA ZONA C1.1 Sistemas de ventilaci\u00f3n personalizados. A los efectos de c\u00e1lculo de la efectividad de la distribuci\u00f3n de aire en la zona en sistemas de ventilaci\u00f3n personalizados, la zona de respiraci\u00f3n debe ser de 0,8 m2 (9 ft2) centrados en cada ocupante… C2. SIMULACI\u00d3N DEL SISTEMA DE DISTRIBUCI\u00d3N DE AIRE C2.1 Simulaci\u00f3n Computacional. La simulaci\u00f3n de los comportamientos fluidodin\u00e1micos (CFD) por ordenador para el c\u00e1lculo de la efectividad de la distribuci\u00f3n de aire de zona debe realizarse seg\u00fan se indica en los puntos siguientes. <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | C2.2 Efectividad de Distribuci\u00f3n de Aire en la Zona. La efectividad de distribuci\u00f3n de aire en la zona (Ez) debe computarse seg\u00fan la Ecuaci\u00f3n C-1 para cada celda computacional en la zona de respiraci\u00f3n. La efectividad de distribuci\u00f3n de aire en… <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | ANEXO INFORMATIVO D: INFORMACI\u00d3N DE EST\u00c1NDARES Y DIRECTRICES NACIONALES PARA PM10, PM25 Y OZONO <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | ANEXO INFORMATIVO E: ECUACIONES ADECUADAS DE BALANCE DE MASA PARA SU APLICACI\u00d3N EN EL PROCEDIMIENTO CAI <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | ANEXO INFORMATIVO F: C\u00c1LCULO SIMPLIFICADO DE LA TASA DE VENTILACI\u00d3N PARA SISTEMAS DE RECIRCULACI\u00d3N MULTIZONA QUE ATIENDEN CATEGOR\u00cdAS DE OCUPACI\u00d3N ESPECIFICADAS EN EDIFICIOS EXISTENTES F1. UTILIZACI\u00d3N DE ESTE ANEXO F2. TOMA DE AIRE EXTERIOR F3. CAUDAL DE AIRE PRIMARIO M\u00cdNIMO DE ZONA <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | ANEXO INFORMATIVO G: APLICACI\u00d3N G1. Aplicaci\u00f3n G1.1 Edificios Nuevos. Deben aplicarse a edificios nuevos, todas las secciones y anexos normativos incluidos dentro del alcance de este est\u00e1ndar. G1.2 Edificios Existentes. El est\u00e1ndar deber\u00eda aplicarse a edificios existentes, al menos en las circunstancias que se describen en los siguientes puntos. <\/td>\n<\/tr>\n | ||||||
58<\/td>\n | ANEXO INFORMATIVO H: DOCUMENTACI\u00d3N H1. CALIDAD DE AIRE EXTERIOR H2. CRITERIOS DE DISE\u00d1O DE VENTILACION DE EDIFICIOS H3. PROCEDIMIENTO DE TASA DE VENTILACION H4. PROCEDIMIENTO CAI <\/td>\n<\/tr>\n | ||||||
61<\/td>\n | ANEXO INFORMATIVO I: JUSTIFICACI\u00d3N DE LA TASA <\/td>\n<\/tr>\n | ||||||
70<\/td>\n | ANEXO INFORMATIVO J: INFORMACI\u00d3N SOBRE VENTILACI\u00d3N NATURAL J1. DATOS SOBRE CALIDAD DEL AIRE EXTERIOR J2. TASA DE VENTILACI\u00d3N NATURAL <\/td>\n<\/tr>\n | ||||||
71<\/td>\n | J3. C\u00c1LCULOS DE LA V\u00cdA A PRESCRIPTIVA J3.1 Intensidad de Ventilaci\u00f3n. Los espacios han sido definidos por la intensidad de la ventilaci\u00f3n, lo que representa la cantidad de caudal necesario seg\u00fan la Ecuaci\u00f3n 6-1, dividida por el \u00e1rea de planta del espacio. Sus unidades son (L\/s)\/m2 d… J3.2 Aberturas \u00danicas. El flujo a trav\u00e9s de una abertura aguda \u00fanica debido al flujo bidireccional impulsado por la flotabilidad (Vbd_sharp) (v\u00e9ase Etheridge and Sandberg [1996] en el Anexo Informativo M) se expresa como sigue: <\/td>\n<\/tr>\n | ||||||
72<\/td>\n | J3.3 Aberturas Espaciadas Verticalmente. El caudal Vvs a trav\u00e9s de \u00e1reas As de aberturas espaciadas verticalmente (la suma menor de las \u00e1reas de las aberturas, aberturas superiores o aberturas inferiores) y Al (la suma mayor de las \u00e1reas de abert… <\/td>\n<\/tr>\n | ||||||
73<\/td>\n | J4. CONTROL Y ACCESIBILIDAD (MODO MIXTO DE VENTILACI\u00d3N) <\/td>\n<\/tr>\n | ||||||
74<\/td>\n | ANEXO INFORMATIVO K: CUMPLIMIENTO K1. SECCI\u00d3N 4 K2. SECCI\u00d3N 5 <\/td>\n<\/tr>\n | ||||||
75<\/td>\n | K3. SECCI\u00d3N 6 PROCECIMIENTO TASA DE VENTILACI\u00d3N (PTV) K3.1 Filtraci\u00f3n K3.2 Tasas de Ventilaci\u00f3n. Debe verificarse el cumplimiento con la tasa de ventilaci\u00f3n con aire exterior en la toma de entrada (Vot) utilizando el proceso siguiente: K4. SECCI\u00d3N 6 PCAI <\/td>\n<\/tr>\n | ||||||
76<\/td>\n | K5. SECCI\u00d3N 6 PROCEDIMIENTO DE VENTILACI\u00d3N NATURAL K6. SECCI\u00d3N 6 EXTRACCI\u00d3N <\/td>\n<\/tr>\n | ||||||
77<\/td>\n | K7. VENTILACI\u00d3N EN EDIFICIOS EXISTENTES K7.1 Filtraci\u00f3n. La filtraci\u00f3n debe cumplir con K7.1.1 y con K7.1.2. K7.2 Caudal de Aire Exterior. El proceso siguiente puede utilizarse para determinar si los caudales de aire exterior cumplen con el est\u00e1ndar, Las \u00e1reas ocupadas pueden determinarse por mediciones, dimensionado de la planta, o a partir de los datos … K7.3 Controles. Se confirma que los controles del sistema de ventilaci\u00f3n cumplen con los requisitos del punto 5.3. <\/td>\n<\/tr>\n | ||||||
78<\/td>\n | ANEXO INFORMATIVO L: TABLA DE COMPROBACI\u00d3N DE LA TASA DE VENTILACI\u00d3N <\/td>\n<\/tr>\n | ||||||
82<\/td>\n | ANEXO INFORMATIVO M: REFERENCIAS INFORMATIVAS <\/td>\n<\/tr>\n | ||||||
83<\/td>\n | ANEXO INFORMATIVO N: PROCEDIMIENTO DE CALIDAD DE AIRE INTERIOR (PCAI) N1. RESUMEN DE DIRECTRICES SELECCIONADAS DE CALIDAD DE AIRE N2. DIRECTRICES PARA LAS TASAS DE EMISI\u00d3N <\/td>\n<\/tr>\n | ||||||
84<\/td>\n | N3. EVALUACI\u00d3N SUBJETIVA N4. BIBLIOGRAF\u00cdA <\/td>\n<\/tr>\n | ||||||
88<\/td>\n | ANEXO INFORMATIVO O: INFORMACI\u00d3N DE DESCRIPCI\u00d3N DE LA ADENDAS <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" ASHRAE Spanish-Standard 62.1-2019 — Ventilation for Acceptable Indoor Air Quality<\/b><\/p>\n |