{"id":304968,"date":"2024-10-19T20:51:49","date_gmt":"2024-10-19T20:51:49","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iso-16014-52012\/"},"modified":"2024-10-25T18:26:09","modified_gmt":"2024-10-25T18:26:09","slug":"bs-en-iso-16014-52012","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iso-16014-52012\/","title":{"rendered":"BS EN ISO 16014-5:2012"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
7<\/td>\n | Foreword <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 1\tScope 2\tNormative references 3\tTerms and definitions <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 4\tSymbols 5\tPrinciple 5.1\tSEC 5.2\tLight-scattering SEC 6\tReagents 6.1\tEluent <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 6.2\tReagent for column evaluation 6.3\tCalibration standards 6.4\tReagent for flow rate marker 6.5\tAdditives 7\tApparatus 7.1\tGeneral <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 7.2\tEluent reservoir 7.3\tPumping system 7.4\tInjector 7.5\tColumns <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 7.6\tDetector 7.7\tTubing 7.8\tTemperature control 7.9\tRecorder and plotter 7.10\tData-processing system 7.11\tOther components 8\tProcedure 8.1\tPreparation of calibration solutions 8.2\tPreparation of a solution for determining the L\u2011point 8.3\tPreparation of sample solutions <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 8.4\tPreparation of solutions for column performance evaluation 8.5\tSetting up the apparatus 8.6\tOperating parameters 8.7\tNumber of determinations 9\tCalibration 9.1\tCalibration of concentration-sensitive detector and light-scattering detector <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 9.2\tDetermination of delay volume 9.3\tNormalization of detector sensitivity 9.4\tDetermination of refractive index increment 10\tData acquisition and processing 10.1\tData acquisition 10.2\tEvaluation of data and correction of chromatograms <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 10.3\tData processing <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 11\tExpression of results 11.1\tCalibration curve <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 11.2\tCalculation of average molecular mass 11.3\tDifferential molecular mass distribution curve 11.4\tCumulative molecular mass distribution curve <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 12\tPrecision 13\tTest report 13.1\tGeneral 13.2\tApparatus and measurement parameters 13.3\tCalibration of the system <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 13.4\tCalibration curve 13.5\tResults <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | Annex\u00a0A \n(informative)<\/p>\n Round-robin test <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | Annex\u00a0B \n(informative)<\/p>\n Information on light scattering <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | Annex\u00a0C \n(informative)<\/p>\n Calibration curve in low molecular mass range <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Plastics. Determination of average molecular mass and molecular mass distribution of polymers using size-exclusion chromatography – Method using light-scattering detection<\/b><\/p>\n |