{"id":319000,"date":"2024-10-19T22:02:24","date_gmt":"2024-10-19T22:02:24","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-iso-13885-22020\/"},"modified":"2024-10-25T20:20:47","modified_gmt":"2024-10-25T20:20:47","slug":"bs-iso-13885-22020","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-iso-13885-22020\/","title":{"rendered":"BS ISO 13885-2:2020"},"content":{"rendered":"

This document specifies the determination of the molar-mass distribution and the average molar mass values M<\/i>n<\/sub> (number average) and M<\/i>w<\/sub> (weight average) of polymers that are soluble in DMAC (N,N-Dimethylacetamide) by gel permeation chromatography (GPC).<\/p>\n

\n
\n NOTE\n <\/div>\n

Also known as size exclusion chromatography (SEC).<\/p>\n<\/div>\n

Even though the chromatograms obtained show good repeatability, it is possible that this method cannot be used with certain polymer types because of specific interactions (e.g. adsorption) within the sample\/eluent\/column system.<\/p>\n

The conditions specified in this document are not applicable to the GPC analysis of polymer samples with M<\/i>w<\/sub> values greater than 106<\/sup> g\/mol and\/or polymers with elution limits outside the calibration range (see 7.6<\/span> and Annex C<\/span>).<\/p>\n

This document includes no correction method (e.g. for the elimination of peak broadening). If absolute molar mass values are required, an absolute method (e.g. membrane osmometry for M<\/i>n<\/sub> or light scattering for M<\/i>w<\/sub>) can be used.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
2<\/td>\nundefined <\/td>\n<\/tr>\n
7<\/td>\nForeword <\/td>\n<\/tr>\n
9<\/td>\n1 Scope
2 Normative references
3 Terms and definitions <\/td>\n<\/tr>\n
10<\/td>\n4 Principle
5 Apparatus <\/td>\n<\/tr>\n
11<\/td>\n5.1 Eluent supply
5.2 Pump
5.3 Injection system
5.4 Separation columns <\/td>\n<\/tr>\n
13<\/td>\n5.5 Column temperature control
5.6 Detector <\/td>\n<\/tr>\n
14<\/td>\n6 Reagents
7 Calibration of the apparatus
7.1 General
7.2 Specification for the calibration standards <\/td>\n<\/tr>\n
15<\/td>\n7.3 Preparation of the calibration solutions for injection
7.4 Conditions for calibration runs
7.5 Measurement of elution volume
7.6 Plotting the calibration curve <\/td>\n<\/tr>\n
16<\/td>\n8 Sampling
9 Preparation for the test
9.1 Preparation of the injection solution <\/td>\n<\/tr>\n
17<\/td>\n9.2 Preparation of the apparatus
10 Analytical parameters <\/td>\n<\/tr>\n
18<\/td>\n11 Data acquisition and evaluation
11.1 General
11.2 Calculation of the net chromatogram from the raw data
11.2.1 Determination of the baseline
11.2.2 Correction of the measured values and of the net chromatogram
11.2.3 \u200bEvaluation limits <\/td>\n<\/tr>\n
19<\/td>\n11.3 Calculation of the average values <\/td>\n<\/tr>\n
20<\/td>\n11.4 Calculation of the distribution curves
12 Precision
12.1 General
12.2 Repeatability <\/td>\n<\/tr>\n
21<\/td>\n12.3 Reproducibility
13 Test report
13.1 General
13.2 General data on the equipment and settings
13.2.1 Data on the equipment used <\/td>\n<\/tr>\n
22<\/td>\n13.2.2 Calibration
13.2.3 \u200bEvaluation <\/td>\n<\/tr>\n
23<\/td>\n13.3 Special data on the sample <\/td>\n<\/tr>\n
24<\/td>\nAnnex A (informative) Conversion of experimental parameters for variant column sizes <\/td>\n<\/tr>\n
25<\/td>\nAnnex B (informative) Example of a data sheet for a polymer standard <\/td>\n<\/tr>\n
27<\/td>\nAnnex C (informative) Explanations <\/td>\n<\/tr>\n
32<\/td>\nBibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Gel permeation chromatography (GPC) – N,N-Dimenthylacetamide (DMAC) as eluent<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2020<\/td>\n34<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":319005,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[1215,2641],"product_tag":[],"class_list":{"0":"post-319000","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-87-060-20","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/319000","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/319005"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=319000"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=319000"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=319000"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}