{"id":361965,"date":"2024-10-20T01:38:28","date_gmt":"2024-10-20T01:38:28","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iec-60603-72020\/"},"modified":"2024-10-26T02:33:39","modified_gmt":"2024-10-26T02:33:39","slug":"bs-en-iec-60603-72020","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iec-60603-72020\/","title":{"rendered":"BS EN IEC 60603-7:2020"},"content":{"rendered":"

IEC 60603-7:2020 is available as IEC 60603-7:2020 RLV<\/span> which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60603-7:2020 covers 8-way, unshielded, free and fixed connectors and is intended to specify the common dimensions (interface dimensions), mechanical, electrical and environmental characteristics and tests for the family of IEC 60603-7-x connectors. These connectors are intermateable (according to IEC 61076-1 level 2) and interoperable with other IEC 60603-7 series connectors. This fourth edition cancels and replaces the third edition, published in 2008, its Amendment 1:2011 and its Amendment 2:2019. It constitutes a technical revision. This edition includes the following significant technical change with respect to the previous edition:- Revised the definitions for intermateability and interoperability; added new definitions. – Corrected dimension line for dimension AZ2 in Figure 5. – Corrected dimension line for dimension F1 in Figure A.1. – Revised the reference to ISO\/IEC 11801 to ISO\/IEC 11801-1. – Added lower limiting temperature and upper limiting temperature definitions. – Revised Table 1 to Table 8 so the column order is Minimum-Nominal-Maximum dimensions (ascending order). – Corrected Table 7: Climatic category and Upper temperature values to 90 \u00b0C (to be consistent with the graph in Figure 10 and Note 1 in Figure 10). – Revised the wording in 8.2, contact resistance, for clarification. – Revised Figure 11 and Figure 12 and the wording in the Key below for clarification. – Removed the sentences under the figure in the Introduction. – Added Annex E.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
2<\/td>\nundefined <\/td>\n<\/tr>\n
5<\/td>\nAnnex ZA(normative)Normative references to international publicationswith their corresponding European publications <\/td>\n<\/tr>\n
9<\/td>\nEnglish
CONTENTS <\/td>\n<\/tr>\n
12<\/td>\nFOREWORD <\/td>\n<\/tr>\n
14<\/td>\nINTRODUCTION
Figures
Figure 1 \u2013 IEC 60603-7 family document diagram <\/td>\n<\/tr>\n
15<\/td>\n1 Scope
2 Normative references <\/td>\n<\/tr>\n
17<\/td>\n3 Terms and definitions <\/td>\n<\/tr>\n
19<\/td>\n4 Common features and typical connector pair
4.1 View showing typical fixed and free connectors (see Figure 2)
Figure 2 \u2013 View showing typical fixed and free connectors <\/td>\n<\/tr>\n
20<\/td>\n4.2 Mating information
4.2.1 General <\/td>\n<\/tr>\n
21<\/td>\n4.2.2 Contacts \u2013 mating conditions
Figure 3 \u2013 Contact interface dimensions with terminated free connector <\/td>\n<\/tr>\n
22<\/td>\nTables
Table 1 \u2013 Dimensions for Figure 3 <\/td>\n<\/tr>\n
23<\/td>\n4.2.3 Fixed connector <\/td>\n<\/tr>\n
24<\/td>\nFigure 4 \u2013 Fixed connector details <\/td>\n<\/tr>\n
25<\/td>\nTable 2 \u2013 Dimensions for Figure 4 <\/td>\n<\/tr>\n
26<\/td>\n4.2.4 Free connector
Figure 5 \u2013 Free connector view <\/td>\n<\/tr>\n
27<\/td>\n5 Cable terminations and internal connections \u2013 Fixed and free connectors
5.1 General
Table 3 \u2013 Dimensions for Figure 5 <\/td>\n<\/tr>\n
28<\/td>\n5.2 Termination types
5.2.1 Solder terminations
5.2.2 Solderless terminations
6 Gauges
6.1 Fixed connectors <\/td>\n<\/tr>\n
29<\/td>\nFigure 6 \u2013 Fixed connector “Go” gauge <\/td>\n<\/tr>\n
30<\/td>\nFigure 7 \u2013 Fixed connector “No-go” gauges <\/td>\n<\/tr>\n
31<\/td>\n6.2 Free connectors
Table 4 \u2013 Dimensions for Figure 6 and Figure 7 <\/td>\n<\/tr>\n
32<\/td>\nFigure 8 \u2013 Free connector “No-go” gauges
Table 5 \u2013 Dimensions for Figure 8 <\/td>\n<\/tr>\n
33<\/td>\nFigure 9 \u2013 Free connector “Go” gauge
Table 6 \u2013 Dimensions for Figure 9 <\/td>\n<\/tr>\n
34<\/td>\n7 Characteristics
7.1 General
7.2 Pin and pair grouping assignment
7.3 Classification into climatic category
Figure 10 \u2013 Fixed connector pin and pair grouping assignment (front view of connector)
Table 7 \u2013 Climatic categories \u2013 selected values <\/td>\n<\/tr>\n
35<\/td>\n7.4 Electrical characteristics
7.4.1 Creepage and clearance distances
7.4.2 Voltage proof
7.4.3 Current-temperature derating
Table 8 \u2013 Creepage and clearance distances <\/td>\n<\/tr>\n
36<\/td>\n7.4.4 Interface contact resistance \u2013 initial only
7.4.5 Input to output DC resistance
7.4.6 Input-to-output DC resistance unbalance
Figure 11 \u2013 Connector de-rating curve <\/td>\n<\/tr>\n
37<\/td>\n7.4.7 Initial insulation resistance
7.4.8 Transfer impedance
7.5 Transmission characteristics
7.6 Mechanical characteristics
7.6.1 Mechanical operation
7.6.2 Effectiveness of connector coupling devices
7.6.3 Insertion and withdrawal forces
8 Tests and test schedule
8.1 General <\/td>\n<\/tr>\n
38<\/td>\n8.2 Arrangement for interface contact resistance test
Figure 12 \u2013 Arrangement for interface contact resistance test <\/td>\n<\/tr>\n
39<\/td>\n8.3 Arrangement for vibration test (test phase CP1)
8.4 Test procedures and measuring methods
Figure 13 \u2013 Arrangement for vibration test <\/td>\n<\/tr>\n
40<\/td>\n8.5 Preconditioning
8.6 Wiring and mounting of specimens
8.6.1 Wiring
8.6.2 Mounting
8.7 Test schedules
8.7.1 General
8.7.2 Basic (minimum) test schedule
8.7.3 Full test schedule <\/td>\n<\/tr>\n
41<\/td>\nTable 9 \u2013 Test group P
Table 10 \u2013 Test group AP <\/td>\n<\/tr>\n
43<\/td>\nTable 11 \u2013 Test group BP <\/td>\n<\/tr>\n
44<\/td>\nTable 12 \u2013 Test group CP <\/td>\n<\/tr>\n
45<\/td>\nTable 13 \u2013 Test group DP <\/td>\n<\/tr>\n
46<\/td>\nTable 14 \u2013 Test group EP
Table 15 \u2013 Test group FP <\/td>\n<\/tr>\n
47<\/td>\nAnnexes
Annex A (normative) Gauging continuity procedure
A.1 Object
A.2 Preparation of the specimens
A.3 Test method
A.4 Final measurements
A.5 Description of the continuity gauge <\/td>\n<\/tr>\n
48<\/td>\nTable A.1 \u2013 Dimensions for Figure A.1 <\/td>\n<\/tr>\n
49<\/td>\nFigure A.1 \u2013 Continuity gauge
Figure A.2 \u2013 Continuity gauge insertion <\/td>\n<\/tr>\n
50<\/td>\nAnnex B (normative) Locking device mechanical operation
B.1 Object
B.2 Preparation of the specimens
B.3 Test method
B.4 Final measurements <\/td>\n<\/tr>\n
51<\/td>\nAnnex C (normative) Gauge requirements
C.1 Fixed connectors
C.2 Free connectors <\/td>\n<\/tr>\n
52<\/td>\nAnnex D (normative) Keystone connector information
D.1 Fixed connector, female contacts Keystone type \u2013 Type A, variant 03 in the previous edition of this standard
Figure D.1 \u2013 Keystone connector
Table D.1 \u2013 Dimensions for Figure D.1 <\/td>\n<\/tr>\n
53<\/td>\nD.2 Mounting dimensions for type A, Keystone type variant 03
Figure D.2 \u2013 Panel drawing
Table D.2 \u2013 Dimensions for Figure D.2 <\/td>\n<\/tr>\n
54<\/td>\nAnnex E (normative) Levels of compatibility
E.1 General <\/td>\n<\/tr>\n
55<\/td>\nE.2 Intermountability
Table E.1 \u2013 Levels of compatibility b) c) and required parameters b) <\/td>\n<\/tr>\n
56<\/td>\nE.3 Intermateability
E.4 Intermountability and intermateability <\/td>\n<\/tr>\n
57<\/td>\nE.5 Interoperability
E.6 Interchangeability
E.7 Backward compatibility <\/td>\n<\/tr>\n
59<\/td>\nBibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Connectors for electronic equipment – Detail specification for 8-way, unshielded, free and fixed connectors<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2020<\/td>\n60<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":361971,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[587,2641],"product_tag":[],"class_list":{"0":"post-361965","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-31-220-10","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/361965","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/361971"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=361965"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=361965"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=361965"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}