{"id":362710,"date":"2024-10-20T01:41:44","date_gmt":"2024-10-20T01:41:44","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iec-62828-22018\/"},"modified":"2024-10-26T02:40:35","modified_gmt":"2024-10-26T02:40:35","slug":"bs-en-iec-62828-22018","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iec-62828-22018\/","title":{"rendered":"BS EN IEC 62828-2:2018"},"content":{"rendered":"
This part of IEC 62828 establishes specific procedures for testing pressure process measurement transmitters (PMT) used in measuring and control systems for industrial processes and for machinery control systems.<\/p>\n
A pressure PMT can feature a remote seal to bring the process variable to the sensing element in the PMT. When the remote seal cannot be separated from the PMT, the complete device is tested.<\/p>\n
For general test procedures, reference is made to IEC 62828-1, which is applicable to all types of process measurement transmitters.<\/p>\n
\nNOTE In industrial and process applications, to indicate the process measurement transmitters, it is common also to use the terms “industrial transmitters”, or “process transmitters”.<\/p>\n<\/blockquote>\n
PDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 2<\/td>\n undefined <\/td>\n<\/tr>\n \n 7<\/td>\n English
CONTENTS <\/td>\n<\/tr>\n\n 9<\/td>\n FOREWORD <\/td>\n<\/tr>\n \n 11<\/td>\n INTRODUCTION <\/td>\n<\/tr>\n \n 12<\/td>\n 1 Scope
2 Normative references
3 Terms and definitions
3.1 General <\/td>\n<\/tr>\n\n 13<\/td>\n Figures
Figure 1 \u2013 Measuring range and associated properties of a pressure PMT <\/td>\n<\/tr>\n\n 14<\/td>\n 3.2 Terms related the process conditions
4 General description of the device and overview
5 Reference test conditions <\/td>\n<\/tr>\n\n 15<\/td>\n 6 Test procedures
6.1 General
6.2 Tests at standard and operating reference test conditions
6.2.1 General
6.2.2 Accuracy test suitable for routine and acceptance tests
Figure 2 \u2013 Schematic example of a test set-up for pressure PMT <\/td>\n<\/tr>\n\n 16<\/td>\n 6.2.3 Overpressure
Figure 3 \u2013 Example of measured error plot
Tables
Table 1 \u2013 Example of measured errors <\/td>\n<\/tr>\n\n 17<\/td>\n Figure 4 \u2013 Procedure for the determination of the unilateral overpressure error <\/td>\n<\/tr>\n \n 18<\/td>\n 6.2.4 Influence of static pressure
Figure 5 \u2013 Schematic example of test set-up for determinethe effect of the static pressure <\/td>\n<\/tr>\n\n 19<\/td>\n Figure 6 \u2013 Procedure for the determination of the zero point error with static pressure <\/td>\n<\/tr>\n \n 20<\/td>\n 6.2.5 Long-term drift
Figure 7 \u2013 Procedure for the determination of the span error for static pressure <\/td>\n<\/tr>\n\n 21<\/td>\n 6.2.6 Leakage test
6.2.7 Additional tests for diaphragm\/remote seals \u2013 Influence of process temperature (long term)
7 Test report and technical documentation
7.1 General <\/td>\n<\/tr>\n\n 22<\/td>\n 7.2 Total probable error <\/td>\n<\/tr>\n \n 23<\/td>\n Annex A (informative)Relationship between the SI unit and other pressure related units
Table A.1 \u2013 Relationship between the SI unit and other pressure related units <\/td>\n<\/tr>\n\n 24<\/td>\n Annex B (informative)Pressure process measurement transmitter (PMT)
B.1 General description of a pressure PMT
B.2 Typical PMTs <\/td>\n<\/tr>\n\n 25<\/td>\n Figure B.1 \u2013 Schematic example of intelligent PMT model <\/td>\n<\/tr>\n \n 26<\/td>\n Annex C (informative)Example of signal current range for a 4 to 20 mA PMT
C.1 Signal current range of a 4 mA to 20 mA transmitter (before adjustment)
C.2 Proportional range
C.3 Normal range
C.4 Underrange
Figure C.1 \u2013 Signal current range of a 4 mA \u2013 20 mA transmitter (before adjustment) <\/td>\n<\/tr>\n\n 27<\/td>\n C.5 Overrange
C.6 Low alarm
C.7 High alarm <\/td>\n<\/tr>\n\n 28<\/td>\n Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Reference conditions and procedures for testing industrial and process measurement transmitters – Specific procedures for pressure transmitters<\/b><\/p>\n
\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2020<\/td>\n 30<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":362721,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2641],"product_tag":[],"class_list":{"0":"post-362710","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-bsi","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/362710","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/362721"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=362710"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=362710"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=362710"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}