{"id":367784,"date":"2024-10-20T02:06:52","date_gmt":"2024-10-20T02:06:52","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-d7179-6\/"},"modified":"2024-10-26T03:32:53","modified_gmt":"2024-10-26T03:32:53","slug":"astm-d7179-6","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-d7179-6\/","title":{"rendered":"ASTM-D7179"},"content":{"rendered":"<\/p>\n
1.1 This test method is used to measure the breaking force of a Geonet.<\/p>\n
1.2 This test is applicable for manufacturing quality control (MQC) and construction quality assurance (CQA) testing and is not recommended as a performance test.<\/p>\n
1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only.<\/p>\n
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | Scope Referenced Documents Terminology Summary of Test Method Significance and Use Apparatus Sampling and Test Specs and Units <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | Conditioning Procedure Calculation Report Precision and Bias Keywords <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" D7179-05 Standard Test Method for Determining Geonet Breaking Force<\/b><\/p>\n |